YORK YP8C Heating and Air Conditioning Installation Guide

June 13, 2024
YORK

TECHNICAL GUIDE
80% MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: YP8C / YPLC
NATURAL GAS
60 – 120 MBH INPUTYORK YP8C Heating and Air
Conditioning

Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at www.ahridirectory.org

WARRANTY

Lifetime limited warranty on heat exchanger to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction.

DESCRIPTION

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in Upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code.

FEATURES

  • Modulating heating operation includes:
    – Modulating gas valve, inducer and circulating blower
    – Modulating operation from 100% input to 50% input in 1% increments

  • Easily applied in Upflow, horizontal left or right, or downflow installation with minimal conversion necessary.

  • Compact, easy to install, ideal height 33″ tall cabinet.

  • ECM variable speed motor for cooling SEER enhancement, blower delay options for comfort, and continuous fan options for IAQ performance.

  • Easy access to controls to connect power/control wiring.

  • Built-in, high level self diagnostics with fault code display.

  • Low unit amp requirement for easy replacement application.

  • All models are convertible to use propane (LP) gas.

  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.

  • 100% shut off main gas valve for extra safety.

  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.

  • Hi-tech tubular aluminized steel primary heat exchanger.

  • Blower door safety switch.

  • Solid removable bottom panel allows easy conversion.

  • Low NOx models have been designed to meet specific code requirements.

  • Airflow leakage less than 1% of nominal airflow for duct blaster conditions.

  • No knockouts to deal with, making installation easier.

  • Movable duct connector flanges for application flexibility.

  • Quiet inducer, burner and blower operation.

  • Inducer rotates for easy conversion of venting options.

  • Fully supported blower assembly for easy access and removal of blower.

  • External air filters used for maximum flexibility in meeting customers IAQ needs.

  • Venting applications – may be installed as a common vent with other gas-fired appliances.

  • Insulated blower compartment for thermal and acoustic performance.

  • 1/4 turn knobs provided for easy door removal.

FOR DISTRIBUTION USE ONLY – NOT TO BE USED AT POINT OF RETAIL SALE
402703-YTG-C-0409

YORK YP8C Heating and Air Conditioning - Fig1

Cabinet and Duct Dimensions

Models| Nominal CFM (m 3/min)| Cabinet Size| Cabinet Dimensions (Inches)| Approximate Operating Weights
---|---|---|---|---
A| B| C| Lbs
YP(8,L)C060A12MP11| 1200| A| 14 1/2| 13 1/4| 10.3| 94
YP(8,L)C080B12MP11| 1200| B| 17 1/2| 16 1/4| 11.8| 103
YP(8,L)C080C16MP11| 1600| C| 21| 19 3/4| 13.6| 114
YP(8,L)C100C16MP11| 1600| C| 21| 19 3/4| 13.6| 118
YP(8,L)C100C20MP11| 2000| C| 21| 19 3/4| 13.6| 122
YP(8,L)C120C20MP11| 2000| C| 21| 19 3/4| 15.8| 129

Ratings & Physical / Electrical Data

Models| Input Max/Min| Output Max/Min| AFUE| Nominal Airflow| Total Unit Amps| Air Temp. Rise Max Input| Air Temp. Rise Min Input
---|---|---|---|---|---|---|---
MBH| MBH| CFM| °F| °F
YP(8,L)C060A12MP11| 60/30| 47/24| 80.0| 1200| 7.0| 30-60| 20-50
YP(8,L)C080B12MP11| 80/40| 62/32| 80.0| 1200| 7.5| 40-70| 20-50
YP(8,L)C080C16MP11| 80/40| 62/32| 80.0| 1600| 10.0| 35-65| 20-50
YP(8,L)C100C16MP11| 100/50| 78/40| 80.0| 1600| 10.0| 35-65| 20-50
YP(8,L)C100C20MP11| 100/50| 78/40| 80.0| 2000| 12.0| 35-65| 20-50
YP(8,L)C120C20MP11| 120/60| 95/48| 80.0| 2000| 12.0| 45-75| 25-55
Models| Max. Outlet Air Temp| Blower| Blower Wheel size| Max Over-Current Protect| Min. wire Size (awl) @ 75 ft one way|
°F| HP| Amps
YP(8,L)C060A12MP11| 160| 1/2| 4.8| 11 x 8| 15| 14
YP(8,L)C080B12MP11| 170| 1/2| 4.8| 11 x 8| 15| 14
YP(8,L)C080C16MP11| 165| 3/4| 7.5| 11 x 10| 15| 14
YP(8,L)C100C16MP11| 165| 3/4| 7.5| 11 x 10| 15| 14
YP(8,L)C100C20MP11| 165| 1| 14.5| 11 x 11| 20| 12
YP(8,L)C120C20MP11| 175| 1| 14.5| 11 x 11| 20| 12

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Performance” table represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
NOTE: Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use of a 20 x 25 filter.
Recommended Filter Sizes

CFM Cabinet Size Side (in) Bottom (in)
1200 A 16 x 25 14 x 25
1200 B 16 x 25 16 x 25
1600 C 16 x 25 20 x 25
2000 C (2) 16 x 25 20 x 25

NOTES:

  1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
  2. Do not exceed 1800 CFM using a single side return and a 16×25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20×25 filter.

Unit Clearances to Combustibles

Application| Top| Front| Rear| Left Side| Right Side| Flue| Floor/ Bottom| Closet| Alcove| Attic| Line Contact
---|---|---|---|---|---|---|---|---|---|---|---
Upflow B-Vent| 1| 3| 0| 0| 0| 1| Combustible| Yes| Yes| Yes| No
Downflow B-Vent| 1| 3| 0| 0| 0| 1| 11| Yes| Yes| Yes| No
Horizontal B-Vent| 1| 3| 0| 0| 0| 1| Combustible| No| Yes| Yes| Yes2

  1. Special floor base or air conditioning coil required for use on combustible floor.
  2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building joists, studs or framing.

ACCESSORIES

PROPANE (LP) CONVERSION KIT –
1NP0680 – All Models
This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation.
SIDE RETURN FILTER RACKS –
1SR0200 – All Models
1SR0302 – All Models
1SF0101 – All Models
BOTTOM RETURN FILTER RACKS –
1BR0514 or 1BR0614 – For 14-1/2” cabinets
1BR0517 or 1BR0617 – For 17-1/2” cabinets
1BR0521 or 1BR0621 – For 21” cabinets
1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet.
COMBUSTIBLE FLOOR BASE KIT –
For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations. These kits are also required in any applications where the furnace in installed in a downflow configuration without an evaporator coil, where the combustible floor base kit provides access for combustible airflow.
1CB0514 – For 14-1/2” cabinets
1CB0517 – For 17-1/2” cabinets
1CB0521 – For 21” cabinets
EAC TRANSITION KITS
For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage.
1TK1001 – For all models using side return
1TK1014 – For 14-1/2” cabinets using bottom return
1TK1017 – For 17-1/2” cabinets using bottom return
1TK1021 – For 21” cabinets using bottom return
1TK1024 – For 24-1/2” cabinets using bottom return
HIGH ALTITUDE – No high altitude kits are required.
ROOM THERMOSTATS – A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1H/1C, manual change-over electronic non-programmable thermostat.
1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.

  • For the most current accessory information, refer to the price book or consult factory.
    Blower Performance CFM – Any Position

High / Low Speed Cooling CFM

060A12| 080B12| Jumper Settings
Hi Cool| Lo Cool| Hi Cool| Lo Cool| COOL Jumper| ADJ Jumper
1340| 900| 1290| 790| H| B
1125| 750| 1065| 660| MH| B
1225| 820| 1165| 720| H| A
1050| 680| 960| 600| MH| A
1100| 740| 1050| 590| H| C
890| 600| 855| 525| ML| B
920| 615| 875| 540| MH| C
675| 450| 640| 395| L| B
815| 545| 775| 495| ML| A
600| 440| 580| 380| L| A
720| 499| 700| 430| ML| C
540| 440| 525| 380| L| C
High / Low Speed Cooling CFM
080C16| 100C16| Jumper Settings
Hi Cool| Lo Cool| Hi Cool| Lo Cool| COOL Jumper| ADJ Jumper
1715| 1165| 1600| 1120| H| B
1520| 1020| 1450| 980| MH| B
1575| 1060| 1500| 1020| H| A
1395| 930| 1345| 900| MH| A
1430| 950| 1315| 930| H| C
1320| 875| 1265| 845| ML| B
1260| 840| 1210| 805| MH| C
1100| 730| 1080| 700| L| B
1200| 795| 1165| 765| ML| A
1000| 665| 980| 635| L| A
1080| 715| 1050| 695| ML| C
900| 600| 885| 585| L| C
High / Low Speed Cooling CFM
100C20| 120C20| Jumper Settings
Hi Cool| Lo Cool| Hi Cool| Lo Cool| COOL Jumper| ADJ Jumper
2110| 1360| 1990| 1290| H| B
1670| 1085| 1760| 1030| MH| B
1900| 1235| 1900| 1210| H| A
1515| 990| 1510| 935| MH| A
1710| 1130| 1800| 1095| H| C
1465| 950| 1540| 900| ML| B
1370| 890| 1440| 845| MH| C
1255| 815| 1320| 790| L| B
1330| 865| 1400| 835| ML| A
1140| 740| 1200| 725| L| A
1195| 780| 1260| 750| ML| C
1025| 665| 1080| 650| L| C

All CFM’s are shown at 0.5” w. c. external static pressure. These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w. c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w. c. external static pressure is not recommended.
NOTE: At some settings, LOW COOL airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.

Subject to change without notice. Published in U.S.A.
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.
402703-YTG-C-0409
Supersedes: 402703-YTG-B-1008
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
Downloaded from www.Manualslib.com manuals search engine

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

YORK User Manuals

Related Manuals