Product Information
The Cardioline ECG100L is a portable 12-lead ECG device designed for use in
medical practices.
It is equipped with advanced features and provides accurate ECG measurements
and interpretation.
Technical Specifications:
- ECG channels: 12-lead
- Patient cable: Yes
- CMRR (Common Mode Rejection Ratio): High
- Input impedance : High
- The sampling rate of the input stage is adjustable
- ECG resolution: High
- Dynamic range: Wide
- Bandwidth : Wide
- Pacemaker detection: Yes
- Filters : Adjustable
- Defibrillation protection: Yes
- Front-end performance: Excellent
- Acquisition mode : Manual and automatic
- Configuration: User-configurable settings
- Lead fail detection: Yes
- ECG measurements: Comprehensive
- ECG interpretation: Advanced algorithms for accurate interpretation
- Export format: SCP, PDF
- PC-ECG Easy App: Yes
Product Usage Instructions
To use the Cardioline ECG100L, please follow these steps:
- Connect the patient cable to the ECG device and attach the leads to the patient’s chest according to the standard 12-lead ECG placement.
- Ensure that the ECG device is powered on and functioning properly.
- Adjust the sampling rate and filters if necessary to optimize the ECG signal quality.
- Select the desired acquisition mode, either manual or automatic.
- If using the automatic acquisition mode, press the appropriate button to start the ECG recording. If using the manual mode, manually trigger the recording when ready.
- During the recording, the device will perform lead fail detection to ensure proper lead connection.
- Once the recording is complete, the device will provide comprehensive ECG measurements and interpretation based on advanced algorithms.
- Choose the desired export format, either SCP or PDF, to save the ECG data.
- If desired, connect a USB key or a USB cable to transfer the ECG data to external devices.
- The PC-ECG Easy App can also be used to export and analyze the ECG data conveniently on a computer or mobile device.
- If needed, you can print the ECG report directly from the device using a compatible printer.
For more information and support, please visit our website at www.cardioline.it.
INSTRUCTION
- The ECG 100L has been designed for total portability and ease of use, without compromising Cardioline’s recognized quality standards.
- Particular attention has been dedicated to device usability, using a brilliant 5-inch color touchscreen display, as well as dedicated keys for fast operation.
- The user is guided through the ECG acquisition procedure step by step, from electrode placement to quality checking, acquisition, printing, and storage.
- Automatic, manual, Stat, or rhythm ECGs can alternatively be acquired at the simple touch of a key.
- The new rhythm ECG function allows for rhythm analysis of 3 minutes of ECG, including HR trending and Variability.
- ECG files can be stored on the device or exported, through a USB connection or memory stick to a specific ECG Management application for PCs, “ECG EasyApp”, designed for easy but complete handling of patient ECGs.
- Glasgow algorithm for ECG interpretation is optionally available for pediatric and adult ECGs.
Technical Specifications
- ECG channels: 12-lead (I, II, III, aVR-L-F, V1-6)
- Patient cable: Standard 15D, 10-wires
- CMRR: >100dB
- Input impedance: 100MΩ
- Sampling rate of the input stage: 32000 samples/second/channel
- ECG resolution: 5μV/LSB; 500 s/s
- Dynamic range: +/- 325 mV
- Bandwidth: Performances equivalent to 0,05-150 Hz
- Pacemaker detection: Hardware detection coupled with convolution digital filtering
- Filters: Linear phase digital diagnostic high-pass filter (acc. to 60601-2-25 2nd ed.) 50/60 Hz AC interference adaptive digital filter Digital low pass filters at 25/40 Hz, for display and printing only
- Defibrillation protection: AAMI/IEC standards
- Front-end performance: ANSI/AAMI IEC 60601-2-25:2011
- Acquisition mode: Automatic (12-leads), Manual (3/6-leads), Stat (12-leads), Rhythm (1/3-leads)
- Configuration: Standard or Cabrera
- Lead fail detection: Independent on all leads
- ECG measurements : All leads, average, QT corrected, Sokolow-Lyon Index
- ECG interpretation: Glasgow Analysis Program for Adults, Pediatric, STEMI
- Export format: SCP-PDF
- PC-ECG “Easy App: Dedicated ECG Management application for PC
OVERVIEW
Documents / Resources
|
CARDIOLINE ECG100L 3/6 Channel New Generation ECG
Device
[pdf] Instruction Manual
ECG100L 3 6 Channel New Generation ECG Device, ECG100L, 3 6 Channel New
Generation ECG Device, New Generation ECG Device, Generation ECG Device, ECG
Device, Device
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>