Anritsu MU100010A Network Master Pro
Product Information
The Network Master Pro MT1000A is a multiplatform device designed for field testing. It consists of various measurement modules that can be configured according to the user’s testing requirements. The main frame controls the test modules and allows for custom configurations.
The MT1000A is compatible with different measurement modules, including
- 10G Multirate Module (MU100010A)
- 100G Multirate Module (MU100011A)
- OTDR Module (MU100020A/MU100021A/MU100022A/MU100023A)
- High Performance GNSS Disciplined Oscillator (MU100090B)
The device is an excellent eco product and comes with standard accessories
such as a high power supply, line cord, softcase, rear panel kit, high power
AC adaptor, li-ion battery, stylus, carrying strap, handle, and utilities ROM.
Optional features include connectivity for WLAN/Bluetooth and AUX I/O.
Product Usage Instructions
To use the Network Master Pro MT1000A, follow these steps
- Choose the appropriate mainframe and mainframe options based on your needs.
- Select your testing requirements, such as comms quality confirmation (OTN, Ethernet, etc.) or optical fiber break and quality checking.
- Select the type of interface you want to measure. For 10G interfaces, use the 10G Multirate Module. For 100G interfaces, use the 100G Multirate Module.
- If measuring PDH/DSn interfaces, Ethernet, and OTN simultaneously, use Port 2. For one-way delay measurement using two MT1000A units, use the 100G module.
- If measuring SyncE wander, use the appropriate module.
Make sure to refer to the module composition for the correct module
combination.
Please note that some options may require retrofitting for already shipped
items. Contact us for assistance in retrofitting.
Network Master Pro MT1000A: Main Frame
The Network Master Pro MT1000A is a multiplatform designed for field testing
that is configured using a combination of transport and optical. The Main
Frame controls the test modules which can be changed freely to any custom
configuration matching the users testing requirements.
Model/Order No. | Name |
---|---|
MT1000A | Network Master Pro |
Standard Accessories
MT1000A-0061| High Power Supply| Installed
| Line Cord2| 1 pc
B0745A| Softcase| 1 pc
B0728A3| Rear Panel kit| 1 pc
G0385A4| High Power AC Adaptor| 1 pc
G0310A| Li-ion Battery| 1 pc
Z1746A| Stylus| 1 pc
Z1747A5| Carrying Strap| 1 pc
Z1748A6| Handle| 1 pc
Z1817A7| Utilities ROM| 1 pc
Options
MT1000A-0038| Connectivity for WLAN/Bluetooth
MT1000A-005*9| AUX I/O
No Measurement Module
- Audio (3.5ø: C TIA Standard)
- AUX (D-SUB 15 pin)
- Clock Input
- USB Mini-B
- USB A
- USB A
- Ethernet Service Interface (For remote control)
- DC Input (18 V DC)
- 9-inch active TFT display and touch screen
- Power switch
- Speaker
*Module Configuration10**
- The presence of the MT1000A-006 option can be recognized at the top right of the front panel. To retrofit to the already shipped item, please contact us.
- One line cord is attached to the area to shipment.
- Composed of B0720A, B0729A, B0730A and B0731A (see pages 15 and 23). Refer to Module Composition for the module combination.
- The MT1000A with MT1000A-006 can be used. Use the AC Adapter G0309A when using the MT1000A without MT1000A-006 installed.
- Shoulder strap for MT1000A.
- Hand strap for MT1000A.
- This DVD includes PDF files and formatting tools of each product’s instruction manual (such as W3933AE, W3810AE, W3736AE, W3946AE).
- WLAN is available for certified countries and regions including USA, Canada, Japan and EU countries. Please visit the Anritsu web site for updated information. Although this product has not been approved by Bluetooth SIG, the supported frequencies are in the range assigned to Bluetooth® communications.
- MT1000A-005 is required for MU100090B. To retrofit to the already shipped item, please contact us.
- Any modular combination as shown in a figure.
- Required if the transport module is not used rear cover.
New Purchase Flowchart
Use this flowchart to select options when purchasing a new MT1000A.
Module Combination Example
New Purchase
Transport Module
10G Multirate Module MU100010A
The 10G Multirate Module MU100010A supports communications network technologies with speeds ranging from 1.5 Mbps to 10 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.
Model | Name |
---|---|
MU100010A | 10G Multirate Module |
Standard Accessories
W3935AE| MT1000A Transport Quick Reference Guide: 1 pc
B0692A*| ESD Box (for optical modules): 1
pc
Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU100010A | Bit Rate | Less than 5G | From 6G to 10G |
---|---|---|---|
Transport Technology | No. of Measurement Ports*1 | 2 (Dual Channel) | 1 (Single |
Channel) | 2 (Dual Channel) |
Ethernet
| IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE,
MPLS,
MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through
| MU100010A-001
Up to 2.7G Dual Channel
| MU100010A-011
Ethernet 10G Single Channel
| MU100010A-012
Ethernet 10G Dual Channel
TCP Throughput Test (RFC 6349, iPerf)| MU100010A-020 TCP Throughput
eCPRI/RoE (IEEE1914.3)
| IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM| MU100010A-001
Up to 2.7G Dual Channel
| MU100010A-011
Ethernet 10G Single Channel
| MU100010A-012
Ethernet 10G Dual Channel
OTN2, 3
| Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
| MU100010A-001
Up to 2.7G Dual Channel
| MU100010A-051
OTN 10G Single Channel
| MU100010A-052
OTN 10G Dual Channel
ODU Multiplexing Addition4| MU100010A-061 ODU Multiplexing
ODU Flex Addition5| —| MU100010A-062 ODU Flex
CPRI/OBSAI
| CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors
Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
|
MU100010A-071
CPRI/OBSAI Up to 5G
Dual Channel
|
MU100010A-072
CPRI/OBSAI 6G to 10G
Single Channel
|
MU100010A-073
CPRI/OBSAI 6G to 10G
Dual Channel
Fibre Channel
| Performance Test, Signal Generation/Monitoring, Latency, BER, Line
Alarm/Error Monitoring| MU100010A-002
FC 1G 2G 4G Dual Channel
| MU100010A-091
FC 8G 10G Single Channel
| MU100010A-092
FC 8G 10G Dual Channel
SDH/SONET, PDH/DSn
| PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan
| MU100010A-001
Up to 2.7G Dual Channel
| MU100010A-081
STM-64 OC-192
Single Channel
| MU100010A-082
STM-64 OC-192
Dual Channel
-
The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software. For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
-
Please see the datasheet for supported OTN mapping.
-
When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the MU100010A-051/052 (for physical port) and the MU100010A-081/082 (for client signal) are required.
-
When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel. -
When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.
2 100G Multirate Module MU100011A
The 100G Multirate Module MU100011A supports communications network technologies with speeds ranging from 10 Mbps to 100 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.
Model | Name |
---|---|
MU100011A* | 100G Multirate Module |
Standard Accessories
W3935AE| MT1000A Transport Quick Reference Guide: 1 pc
B0763A| ESD Box (for optical modules):** 1 pc
- One MT1000A-006 is rCFP4 plus eitherequir up ted foro tw MU100011A.o QSFP28s or up to four SFP/SFP+s can be stored.
Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU100011A | Bit Rate | Up to 10G | Higher than 10G |
---|---|---|---|
Transport Technology | No. of Measurement Ports*1 | 1 |
(Single Channel)
| 2
(Dual Channel)
| 1
(Single Channel)
| 2
(Dual Channel)
Ethernet
| IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM,
SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In- band Control, Auto discovery, Path-through
| MU100011A-001
Up to 10G
Single Channel
| MU100011A-003
Up to 10G
Dual Channel
| MU100011A-017*8
Ethernet 25G Single Channel
| —
MU100011A-013*9
Ethernet 40G Single Channel
| —
MU100011A-015*9
Ethernet 100G Single Channel
| —
TCP Throughput Test (RFC 6349, iPerf)| MU100011A-020 TCP Throughput| —| —
SyncE Wander| MU100011A-02110 SyncE Wander| —
Measurement using 100GBASE-SR| —| —| MU100011A-0238
RS-FEC for 100GBASE-SR4
MU100011A-015*9
Ethernet 100G Single Channel
| —
eCPRI/RoE (IEEE1914.3)
| IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM| MU100011A-001
Up to 10G
Single Channel
| MU100011A-003
Up to 10G
Dual Channel
| MU100011A-017*8
Ethernet 25G Single Channel
| MU100011A-0757, 8
eCPRI/RoE 25G Dual Channel
MU100011A-013*9
Ethernet 40G Single Channel
| —
MU100011A-015*9
Ethernet 100G Single Channel
| —
Measurement using 100GBASE-SR| —| —| MU100011A-023*8
RS-FEC for 100GBASE-SR4
MU100011A-015*9
Ethernet 100G Single Channel
| —
OTN2, 3
| Errors/Alarms, Error Performance/Delay/APS Test, FEC Test,
O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
| MU100011A-001
Up to 10G
Single Channel
| MU100011A-003
Up to 10G
Dual Channel
| MU100011A-053
OTN 40G Single Channel
| —
MU100011A-055
OTN 100G Single Channel
| —
ODU Multiplexing Addition2, 4| MU100011A-063 ODU Multiplexing/Multi Stage
ODU Flex Addition2, 5| MU100011A-062 ODU Flex| —
CPRI/OBSAI
|
- CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER
- CPRI/OBSAI L2 : Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
| MU100011A-071
CPRI/OBSAI
Up to 10G Single Channel
| MU100011A-072
CPRI/OBSAI
Up to 10G Dual Channel
| MU100011A-073
CPRI 12/25G Single Channel
| MU100011A-074
CPRI 12/25G Dual Channel
Fibre Channel
| Performance Test, Signal Generation/Monitoring, Latency, BER, Line
Alarm/Error Monitoring| MU100011A-004
Up to 10G FC
Single Channel
| MU100011A-005
Up to 10G FC
Dual Channel
| MU100011A-091
FC 16G Single Channel
| —
SDH/SONET
| PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan
| MU100011A-001
Up to 10G
Single Channel
| MU100011A-003
Up to 10G
Dual Channel
| MU100011A-083*6
STM-256/OC-768
Client Signal
| —
-
The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software. For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
-
Please see the datasheet for supported OTN mapping.
-
When using the OTN function, the channel can be used as client signal mapped to OTN.
For example, when mapping STM-256/OC-768 to OTU4, both the MU100011A-055 (for physical port) and the MU100011A-083 (for client signal) are required. -
When the ODU Multiplexing/Multistage option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel. -
This mapping function is based on the ODU Flex standard for transmissions over OTN networks and supports client signals of any speed. This one option supports both single channel and dual channel.
-
The MU100011A has no STM-256/OC-768 PHY interface; it can be used for OTN client signals.
-
Option supports eCPRI/RoE protocol tests only.
-
FEC selectable On/Off.
-
FEC is always Off.
-
40G and 100G are not supported.
Table 1 Protocol Configuration Examples
- Pattern 1: When using 2.7 Gbps max. SDH/SONET/OTN/Ethernet interface and 10 GigE single channel
Model | Name | Notes |
---|---|---|
MU100010A-001 | Up to 2.7G Dual Channel | Measures (OTU1, 1 GigE, STM-16/OC-48) |
signals at 2 ports simultaneously at up to 2.7 Gbps max.
MU100010A-012| Ethernet 10G Dual Channel| Measures 1 port of 10 Gbps Ethernet
Interface
- With 1 channel running at 10 GigE on either physical port testing on the other physical port can be completed using the 2.7 Gbps channel option.
- Pattern 2 : When using 10 Gbps max. SDH/SONET/OTN/Ethernet interface, 100 GigE single channel and 10G bps max FC/CPRI/OBSAI single channel.
Model | Name | Notes |
---|---|---|
MU100011A-003 | Up to 10G Dual Channel | Measures (Ethernet, OTN, SDH/SONET) |
signals at 2 ports simultaneously at up to 10 Gbps max.
MU100011A-015| Ethernet 100G Single Channel| Measures 1 port of 100 Gbps
Ethernet Interface
MU100011A-004| Up to 10G FC Single Channel| Measures 1 port of up to 10 Gbps
Fibre Channel Interface
MU100011A-071| CPRI/OBSAI Up to 10G Single Channel| Measures 1 port of up to
10 Gbps CPRI/OBSAI Interface
Performing a mapping test from 10 Gbps OTN physical interface to any 10 Gbps client signal. And the test a 100 Gbps Ethernet interface.
Selecting Optical Transceiver for Transport Module
Optical modules supporting the optical standards can be inserted for testing
using the MU100010A/MU100011A. Select the optical module matching the test
requirements.
Transport Module
Choosing High-Accuracy Oscillator Option
- High Performance GNSS Disciplined Oscillator MU100090B
- The High Performance GNSS Disciplined Oscillator MU100090B supplies GPS/GLONASS/Galileo/Beidou/QZSS-synchronized 1PPS, 10 MHz, and Time of Day (ToD) to the MT1000A as references for measuring the network and equipment time periodic error and SyncE frequency deviation using the MU100010A or MU100011A.
- Adding the MU100011A-021 to the MU100011A supports SyncE Wander. The target measurement signal is the timestamp in the 1PPS or IEEE1588 Ethernet frame. GbE, 10GbE, and 25GbE optical interfaces are supported. In addition, Ethernet one-way delay (OWD) between two distant points can be measured using two MT1000A/MU100011A units and one MU100090B.
Choosing MU100090B Options
The High
Performance GNSS Disciplined Oscillator MU100090B supplies
GPS/GLONASS/Galileo/Beidou/QZSS-synchronized 1PPS, 10 MHz, and Time of Day
(ToD) to the MT1000A as references for measuring the network and equipment
time periodic error and SyncE frequency deviation using the MU100010A or
MU100011A.
Adding the MU100011A-021 to the MU100011A supports SyncE Wander. The target
measurement signal is the timestamp in the 1PPS or IEEE1588 Ethernet frame.
GbE, 10GbE, and 25GbE optical interfaces are supported. In addition, Ethernet
one-way delay (OWD) between two distant points can be measured using two
MT1000A/MU100011A units and one MU100090B.
Model/Order No. | Name |
---|---|
MU100090B*1 | High Performance GNSS Disciplined Oscillator |
MU100090B-001 | High Stability/Multi-Band |
MU100090B-002 | Multi-GNSS |
Standard Accessories
J1705A| AUX Conversion Adaptor
J1886A2| GNSS Antenna
J1710A| BNC Cable (20 cm) × 2
Z2122A| Tripod for GNSS Antenna
Mandatory Main Frame Option
MT1000A-0053| AUX I/O
MU100011A Option
MU100011A-021| SyncE Wander
- Excellent Eco Product non-compliant.
- With 5 m cable, IP67 Ingress protection.
- MT1000A-005 is required for MU100090B.
Choosing MU100090B Options
- High-Stability/Multi-band Option (MU100090B-001)
- Installing this option raises the GNSS reference-timing synchronization accuracy and Holdover performance.
- GNSS reference-timing synchronization accuracy
- Without Option 001: ±45 ns rms*1
- With Option 001: ±10 ns rms*2
- Holdover performance*3
- Without Option 001: within 300 ns/10,000 s
- With Option 001: within 70 ns/3600 s, within 190 ns/10,000 s
- With OSC LED lit continuously for at least 3 hours and using Anritsu antenna under open-sky and GNSS signal synchronized for 30 or more minutes at constant ambient temperature.
- After OSC LED lit, using Anritsu antenna under open-sky and GNSS signal synchronized for 30 or more minutes at constant ambient temperature with multi-band setting and antenna position specified.
- With OSC LED lit continuously for at least 3 hours and using Anritsu antenna under open-sky and GNSS signal synchronized for 30 or more minutes with ambient temperature change within ±3°C during Holdover.
- Multi-GNSS Option (MU100090B-002)
- This option can increase the number of selectable GNSS (Global Navigation Satellite System) satellites. For synchronization measurement, at least four satellites must be in line of sight without multipaths. Since adding this option supplements the number of line of sight satellites, it widens the synchronization measurement range.
- In addition to using the standard U.S. GPS satellites, adding this option supports use of GLONASS (Russia), Galileo (Europe), Beidou (China), and QZSS (Japan) satellites.
Selecting Transport Test Option
These options are used in combination with the MU100010A module. Choose
options matching the customer’s test requirements. Additionally today, these
options cannot be used in combination with the OTDR Module
MU100020A/MU100021A/MU100022A.
Model | Name | Notes |
---|---|---|
G0325A | GPS Receiver | It is required when measuring one-way latency at |
Ethernet tests.
However, it is unnecessary when purchasing MU100090B.
W3933AE| MT1000A Transport Module Operation Manual| Printed manual
W3736AE| MT1000A/MT1100A Remote Scripting Operation Manual| Printed manual
Z1821A| Utilities in USB Stick| USB memory with operation manual, remote
scripts instruction manual, etc.
J1583A| Optical Attenuator 10 dB LC/PC to LC/PC|
J1584A| RJ45 Cable 3 m|
J1585A| RJ48 to Crocodile Clips Cable 3 m| E1 interface cable.
J1586A| RJ48 to Crocodile Clips Cable 20 dB ATT 3 m| E1 interface cable.
J1588A| BNC Cable 2.5 m| E1, E3, E4, DS3, STM-1e, STS-3 interface cable.
Impedance : 75Ω
J1589A| BNC to 1.6/5.6 Cable 2.5 m| E1, E3, E4, DS3, STM-1e, STS-3
interface cable. Impedance: 75Ω
J1591A| RJ48 to Two 3-pin Banana Plug Cable 2.5 m| E1 interface cable.
J1597A| RJ48 Balanced PDH Cable Crossed 3 m| E1 interface cable.
J1598A| Bantam Cable 3 m| DS1 interface cable.
J1710A| BNC Cable 0.2 m| BNC cable for MU100090B and main-frame external clock
input connector.
- Impedance: 50Ω
J0127B| COAXIAL CORD, 2.0 M| BNC cable for MU100090B and main-frame external clock input connector.
- Impedance: 50Ω
OTDR Module 1310/1550 nm SMF MU100020A
The OTDR Module 1310/1550 nm SMF MU100020A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR, FTTA, and OLTS measurements required for checking optical fiber. Select a model with the dynamic range matching the test requirements. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.
Model | Name |
---|---|
MU100020A | OTDR Module 1310/1550 nm SMF |
Standard Accessories
J1693A| Universal Connector 2.5 mm for OPM: 1 pc
J1694A| Universal Connector 1.25 mm for OP M: 1 pc
W3811AE| Quick Reference Guide : 1
pc
Selecting Dynamic Range
The MU100020A is available in three models with different dynamic ranges
matching the test environment. Select the One matching the test requirements.
Wavelength: Dynamic Range | Model | Name |
---|---|---|
1310/1550 nm: 39/37.5 dB | MU100020A-020 | Standard Dynamic Range |
1310/1550 nm: 42/41 dB | MU100020A-021 | Enhanced Dynamic Range |
1 310/1550 nm: 46/46 dB | MU100020A-022 | High-Performance Dynamic Range |
Selecting Polish Type/Connector Adapter
The MU100020A is available in a total of five models (3 UPC and 2 APC) as
listed below. Specify the required connector type at ordering. The specified
connector is provided as a standard accessory. The polish type cannot be
changed after purchase.
Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source.
This option cannot be added after purchase.
Model | Name | Notes |
---|---|---|
MU100020A-002 | Visual Fault Locator | For direct insertion of 2.5 mm (FC, SC, |
DIN) optical fiber with fixed diameter of 2.5 mm
J1335A| MU/LC Connector Adapter| Required conversion adapter for inserting LC (1.25 mm) optical fiber
OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A
The OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A is an OTDR module for single and multimode fiber use. It supports all-in-one OTDR, FTTA, and OLTS measurements required for checking optical fiber. Select a model with the dynamic range matching the test requirements. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.
Model | Name |
---|---|
MU100021A | OTDR Module 1310/1550/850/1300 nm SMF/MMF |
Standard Accessories
J1693A| Universal Connector 2.5 mm for OPM: 1 pc
J1694A| Universal Connector 1.25 mm for OPM: 1 pc
W3811AE| Quick Reference Guide: 1
pc
Selecting Dynamic Range
The MU100021A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range | Model | Name |
---|---|---|
1310/1550/850/1300 nm : 42/41/29/28 dB | MU100021A-021 | Enhanced Dynamic |
Range
Selecting Polish Type/Connector Adapter
The MU100021A is available in a total of five models (3 UPC and 2 APC) as
listed below. Specify the required connector type at ordering. Two specified
connectors (for SMF and MMF ports) are provided as standard accessories. The
polish type cannot be changed after purchase.
- Different connector adapter types cannot be specified for the SMF and MMF ports.
- There is no APC polish type for the MMF port. As a result, this connector adapter polish type is UPC.
Selecting Visible Light Source Option
Breaks in the optical fiber can be detected by eye using this light source.
This option cannot be added by retrofit after purchase.
Model | Name | Notes |
---|---|---|
MU100021A-002 | Visual Fault Locator | For direct insertion of 2.5 mm (FC, SC, |
DIN) optical fiber with fixed diameter of 2.5 mm.
J1335A| MU/LC Connector Adapter| Required conversion adapter for inserting LC (1.25 mm) optical fiber
OTDR Module 1310/1550/1625 nm SMF MU100022A
The OTDR Module 1310/1550/1625 nm SMF MU100022A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR, FTTA, and OLTS measurements required for checking optical fiber. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.
Model | Name |
---|---|
MU100022A | OTDR Module 1310/1550/1625 nm SMF |
Standard Accessories
J1693A| Universal Connector 2.5 mm for OP M: 1 pc
J1694A| Universal Connector 1.25 mm for OPM: 1 pc
W3811AE| Quick Reference Guide: 1
pc
Selecting Dynamic Range
The MU100022A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range | Model | Name |
---|---|---|
1 310/1550/1625 nm: 46/46/44 dB | MU100022A-022 | High-Performance Dynamic |
Range
Selecting Polish Type/Connector Adapter
The MU100022A is available in a total of five models (3 UPC and 2 APC) as
listed below. Specify the required connector type at ordering. The specified
connector is provided as a standard accessory. The polish type cannot be
changed after purchase.
Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source.
This option cannot be added after purchase.
Model | Name | Notes |
---|---|---|
MU100022A-002 | Visual Fault Locator | For direct insertion of 2.5 mm (FC, SC, |
DIN) optical fiber with fixed diameter of 2.5 mm
J1335A| MU/LC Connector Adapter| Required conversion adapter for inserting LC (1.25 mm) optical fiber
OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A
The OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR, FTTA, and OLTS measurements required for checking optical fiber. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.
Model | Name |
---|---|
MU100023A | OTDR Module 1310/1550/1650 nm SMF |
Standard Accessories
J1693A| Universal Connector 2.5 mm for OPM : 1 pc
J1694A| Universal Connector 1.25 mm for OPM : 1 pc
W3811AE| Quick Reference Guide : 1
pc
Selecting Dynamic Range
The MU100023A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range | Model | Name |
---|---|---|
13 10/1550 nm: 4 2/41 dB, 1650 nm: 35 dB | MU100023A-021 | Enhanced Dynamic |
Range
Selecting Polish Type/Connector Adapter
The MU100023A is available in a total of five models (3 UPC and 2 APC) as
listed below. Specify the required connector type at ordering. The specified
connector is provided as a standard accessory. The polish type cannot be
changed after purchase.
- Different types of connector adapters cannot be selected for the SM port (1310/1550 nm) and the SM port (1650 nm).
Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source.
This option cannot be added after purchase.
Model | Name | Notes |
---|---|---|
MU100023A-002 | Visual Fault Locator | For direct insertion of 2.5 mm (FC, SC, |
DIN) optical fiber with fixed diameter of 2.5 mm.
J1335A| MU/LC Connector Adapter| Required conversion adapter for inserting LC (1.25 mm) optical fiber
Selecting MU100020A/MU100021A/MU100022A/MU100023A Options
The OTDR Module connector is available in a total of five types (3 UPC and 2
APC). These connectors can be changed freely by the user. However, connectors
with mismatched polish types cannot be used. In addition, the
MU100010A/MU100011A cannot be used.
OTDR Module Conversion Connector Adapters
Optical Fiber Conversion Adapters
Others
Model | Name | Notes |
---|---|---|
NETWORKS | PC Emulation Software for Data Analysis and Reporting | Supports PC |
running Microsoft Windows 7 and Windows 10 to edit waveform data and create
reports
W3810AE| MT1000A MU100020A Network Master Pro Operation Manual| MT1000A and
MU100020A/MU100021A/MU100022A/MU100023A operation manuals
Common Application Parts, Extended Warranty Services and Remote Software Service
MT1000A Selecting Common Application Parts
Various application parts make the MT1000A more convenient to use.
Softcase B0745A (Standard Accessory)
This bag with shoulder strap can hold the MT1000A with up to three installed
modules.
Hard Case B0691B
This strong plastic case can hold the MT1000A with up to two installed
modules.
462 (W) × 372 (H) × 207 (D) mm
Battery Charger G0324A
This is the charger for the MT1000A G0310A Li-ion battery.
GPIB–USB Converter J1667A
Converter connected to MT1000A USB interface for controlling MT1000A over GPIB
using commands from external PC controller.
AC Adapter G0309A
This AC adapter is used with the MT1000A without MT1000A-006.
It cannot be used with the MT1000A with MT1000A-006 installed.
Car 12 Vdc Adapter J1569B
This adapter supplies power to the MT1000A from an automobile 12-V cigarette
lighter plug.
Use the accessory attachment supplied with the MT1000A main unit with
MT1000A-006 installed.
Video Inspection Probe G0382A/G0306B
- Scratches and dirt on the connector end face are a major cause of degraded communications quality.
- The MT1000A has a built-in VIP function for analyzing the condition of the optical connector end face in the utility menu. When the VIP is connected, scratches and dirt on the optical connector end face are visualized (× 400) and the OK/NG status is evaluated based on the IEC61300-3-35 standard.
- Anritsu supports VIP Series G0382A (USB Autofocus Type) and G0306B (USB Standard Type).
Different tip types are used by the G0382A and G0306B.
Optical Cables
Model | Name | Notes |
---|---|---|
J1571A | Optical cable SM LC/PC to SC/PC 3 m | Single core (no paired cables) |
J1575A | Optical Cable SM LC/PC to FC/PC 3 m | Single core (no paired cables) |
J1579A | Optical Cable SM LC/PC to LC/PC 3 m | Single core (no paired cables) |
J1581A | Optical Cable MM LC/PC to LC/PC 3 m | Single core (no paired cables) |
MT1000A Module Connection Parts
Model | Name | Notes |
---|---|---|
B0720A | Rear Panel | MT1000A Rear Panel |
B0728A | Rear Panel Kit | Rear Panel (B0720A) and Screw kit (B0732A) (Same as |
standard accessory)
B0729A| Screw 1U| 1 unit screw set (Total 4 pcs)
B0730A| Screw 2U| 2 units screw set (Total 4 pcs)
B0731A| Screw 3U| 3 units screw set (Total 4 pcs)
B0732A| Screw Kit| 1U, 2U, 3U screw (Total 12 pcs)
MT1000A Selecting Extended Warranty Services
The standard warranty period is 1 year. An extended warranty can be purchased
for the main frame and the test interface modules as listed below.
Model | Name |
---|
MT1000A
MT1000A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MT1000A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MT1000A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100010A
MU100010A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100010A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100010A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100011A
MU100011A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100011A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100011A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100090B
MU100090B-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100090B-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100090B-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
Model| Name
---|---
MU100020A
MU100020A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100020A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100020A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100021A
MU100021A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100021A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100021A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100022A
MU100022A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100022A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100022A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100023A
MU100023A-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100023A-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100023A-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
Remote Software Service
The following licenses must be purchased to use the MX109020A Site Over Remote
Access.
Mainframe Option License
Model/Order No. | Name |
---|---|
MT1000A-003*1 | WLAN/Bluetooth Connect |
MT1000A-011*2 | Site Over Remote Access Connect |
- WLAN is available for certified countries and regions including USA, Canada, Japan and EU countries. Please visit the Anritsu web site for updated information. Although this product has not been approved by Bluetooth SIG, the supported frequencies are in the range assigned to Bluetooth® communications.
- Validity period is unlimited. An open TCP port may be required to allow the MT1000A to be connected from an in-company LAN to MX109020A, depending on the LAN security policy.
Subscription Option License
Model/Order No. | Name |
---|---|
MX109020A3, 5, 6, 7 | Site Over Remote Access Basic License |
MX109020A-TL0013, 4 | Site Over Remote Access 1 Year License |
MX109020A-001*5 | Site Over Remote Access 8 Units |
MX109020A-002*5 | Site Over Remote Access Unlimited Units |
MX109020A-003*8 | Centralized Data Management |
-
We recommend purchasing a 1-year license in addition to the basic license.
-
When extending the usage period, we recommend purchasing in 1-year license periods
-
Up to two measuring instruments can be remotely controlled simultaneously with the basic license.
This number can be increased to up to 8 units by purchasing the MX109020A-001 option, and up to 100 units by purchasing the MX109020A-002 option. -
You must agree to the service terms before purchasing SORA.
- Refer to the service terms at the following UR L: https://www.anritsu.com/en-AU/test-measurement/support/downloads/manuals/dwl20059
-
This product cannot be used in some regions and countries; please read the service terms for more details.
-
Users must provide their own storage at the upload destination.
Additional Purchases Flowchart
Use this flowchart when adding modules and options to a previously purchased MT1000A.
Additional Purchases
Adding New Options to Previously Purchased MT1000A
Confirm the serial numbers of the MT1000A and MU100010A/MU100011A.
Adding Test Protocols for Transport Module
When adding protocol options later, specify one of the following media types
as well as the option.
Model | Name |
---|---|
Z1849A | DVD-ROM for Retrofit Options |
Z1850A | USB Stick for Retrofit Options |
In addition, when purchasing multiple retrofit options at one time, they are all installed using the same media.
< MU100010A>
To add a new protocol option to a previously purchased MU100010A, choose the
required option from the following list. The MU100010A serial number is
required to make the purchase.
Adding MU100010A Protocol Option | Bit Rate | Less than 5G | From 6G to 10G |
---|---|---|---|
Transport Technology | No. of Measurement Ports*1 | 2 (Dual Channel) | 1 (Single |
Channel) | 2 (Dual Channel) |
Ethernet
| IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE,
MPLS,
MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through
| MU100010A-301
Up to 2.7G Dual Channel Retrofit
| MU100010A-311
Ethernet 10G Single Channel Retrofit
| MU100010A-312
Ethernet 10G Dual Channel Retrofit
TCP Throughput Test (RFC 6349, iPerf)| MU100010A-320 TCP Throughput Retrofit
eCPRI/RoE (IEEE1914.3)
| IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM| MU100010A-301
Up to 2.7G Dual Channel Retrofit
| MU100010A-311
Ethernet 10G Single Channel Retrofit
| MU100010A-312
Ethernet 10G Dual Channel Retrofit
OTN*2,
| Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan|
MU100010A-301
Up to 2.7G Dual Channel Retrofit
| MU100010A-351
OTN 10G Single Channel Retrofit
| MU100010A-352
OTN 10G Dual Channel Retrofit
ODU Multiplexing Addition3| MU100010A-361 ODU Multiplexing Retrofit
ODU Flex Addition4| —| MU100010A-362 ODU Flex Retrofit
CPRI/OBSAI
|
- CPRI/OBSAI L1 : Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER
- CPRI/OBSAI L 2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement,
Monitoring using Passthrough
| MU100010A-371
CPRI/OBSAI Up to 5G
Dual Channel Retrofit
| MU100010A-372
CPRI/OBSAI 6G to 10G
Single Channel Retrofit
| MU100010A-373
CPRI/OBSAI 6G to 10G
Dual Channel Retrofit
Fibre Channel
| Performance Test, Signal Generation/Monitoring, Latency, BER, Line
Alarm/Error Monitoring| MU100010A-302
FC 1G 2G 4G Dual Channel Retrofit
| MU100010A-391
FC 8G 10G Single Channel Retrofit
| MU100010A-392
FC 8G 10G Dual Channel Retrofit
SDH/SONET, PDH/DSn
| PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan
| MU100010A-301
Up to 2.7G Dual Channel Retrofit
| MU100010A-381
STM-64 OC-192
Single Channel Retrofit
| MU100010A-382
STM-64 OC-192
Dual Channel Retrofit
-
The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software. For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
-
When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the MU100010A-351/352 (for physical port) and the MU100010A-381/382 (for client signal) are required.
-
When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel. -
When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.
< MU100011A>
To add a new protocol option to a previously purchased MU100011A, choose the
required option from the following list. The MU100011A serial number is
required to make the purchase.
Adding MU100010A Protocol Option | Bit Rate | Up to 10G | Higher than 10G |
---|---|---|---|
Transport Technology | No. of Measurement Ports*1 | 1 (Single Channel) | 2 (Dual |
Channel) | 1 (Single Channel) | 2 (Dual Channel) |
Ethernet
| IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM,
SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In- band Control, Auto discovery, Path-through
| MU100011A-301
Up to 10G
Single Channel Retrofit
| MU100011A-303
Up to 10G
Dual Channel Retrofit
| MU100011A-317*8
Ethernet 25G
Single Channel Retrofit
| —
MU100011A-313*9
Ethernet 40G
Single Channel Retrofit
| —
MU100011A-315*9
Ethernet 100G
Single Channel Retrofit
| —
TCP Throughput Test (RFC 6349, iPerf)| MU100011A-320 TCP Throughput| —| —
SyncE Wander| MU100011A-02110 SyncE Wander| —
Measurement using 100GBASE-SR| —| —| MU100011A-3238
RS-FEC for 100GBASE-SR4
Retrofit
MU100011A-315*9
Ethernet 100G
Single Channel Retrofit
| —
eCPRI/RoE (IEEE1914.3)
| IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM| MU100011A-301
Up to 10G
Single Channel Retrofit
| MU100011A-303
Up to 10G
Dual Channel Retrofit
| MU100011A-317*8
Ethernet 25G
Single Channel Retrofit
| MU100011A-3757, 8
eCPRI/RoE 25G Dual
Channel Retrofit
MU100011A-313*9
Ethernet 40G
Single Channel Retrofit
| —
MU100011A-315*9
Ethernet 100G
Single Channel Retrofit
| —
Measurement using 100GBASE-SR| —| —| MU100011A-323*8
RS-FEC for 100GBASE-SR4
Retrofit
MU100011A-315*9
Ethernet 100G
Single Channel Retrofit
| —
OTN2, 3
| Errors/Alarms, Error Performance/Delay/APS Test, FEC Test,
O.182 Test, Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
| MU100011A-301
Up to 10G
Single Channel Retrofit
| MU100011A-303
Up to 10G
Dual Channel Retrofit
| MU100011A-353
OTN 40G
Single Channel Retrofit
| —
MU100011A-355
OTN 100G
Single Channel Retrofit
| —
ODU Multiplexing Addition2, 4| MU100011A-363 ODU Multiplexing/Multi Stage
Retrofit
ODU Flex Addition2, 5| MU100011A-362 ODU Flex Retrofit| —
CPRI/OBSAI
|
- CPRI/OBSAI L 1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER
- CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
| MU100011A-371
CPRI/OBSAI Up to 10G
Single Channel Retrofit
| MU100011A-372
CPRI/OBSAI Up to 10G
Dual Channel Retrofit
| MU100011A-373
CPRI 12/25G
Single Channel Retrofit
| MU100011A-374
CPRI 12/25G
Dual Channel Retrofit
Fibre Channel
| Performance Test, Signal Generation/Monitoring, Latency, BER, Line
Alarm/Error Monitoring| MU100011A-304
Up to 10G FC
Single Channel Retrofit
| MU100011A-305
Up to 10G FC
Dual Channel Retrofit
| MU100011A-391
FC 16G
Single Channel Retrofit
| —
SDH/SONET
| PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan
| MU100011A-301
Up to 10G
Single Channel Retrofit
| MU100011A-303
Up to 10G
Dual Channel Retrofit
| MU100011A-383*6
STM-256/OC-768
Client Signal Retrofit
| —
-
The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software. For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
-
Please see the datasheet for supported OTN mapping.
-
When using the OTN function, the channel can be used as client signal mapped to OTN.
For example, when mapping STM-256/OC-768 to OTU4, both the MU100011A-355 (for physical port) and the MU100011A-383 (for client signal) are required. -
When the ODU Multiplexing/Multistage option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel. -
This mapping function is based on the ODUFlex standard for transmissions over OTN networks and supports client signals of any speed.
-
The MU100011A has no STM-256/OC-768 PHY interface; it can be used for OTN client signals.
-
Option supports eCPRI/RoE protocol tests only.
-
FEC can be switched ON/OFF.
-
FEC is always OFF.
-
40G and 100G are not supported.
Adding Main Frame Options for Transport Function
The MT1000A serial number is required at purchase.
Model | Name | Notes |
---|---|---|
MT1000A-303 | Connectivity for WLAN/Bluetooth Retrofit | WLAN/Bluetooth options |
(can be used in approved countries, including N. America, Japan, EU; see Anritsu web site for latest list of countries)
When adding protocol options later, specify one of the following media types as well as the option.
Model | Name |
---|---|
Z1849A | DVD-ROM for Retrofit Options |
Z1850A | USB Stick for Retrofit Options |
MT1000A-311*1 | Site Over Remote Access Connect Retrofit |
- This option enables remote control of the MT1000A using the Site Over Remote Access MX109020A software. We recommend using in conjunction with the WLAN/ Bluetooth option MT1000A-003/303. A WLAN dongle can be used in countries and regions where WLAN is not supported. For a list of supported WLAN dongles, please contact us.
Adding Transport Module
When adding the MU100010A to a previously purchased MT1000A, use the same
procedure as for 10G Multirate Module MU100010A described on pages 6 thru 8,
16 and 17.
Adding Network Time/Phase Synchronization Test
Purchase the following products when adding the Network Time/Phase
synchronization test and measuring using two synchronized MT1000A units.
High Performance GNSS Disciplined Oscillator MU100090B
Model/Order No. | Name |
---|---|
MU100090B | High Performance GNSS Disciplined Oscillator |
MU100090B-001 | High Stability/Multi-Band |
MU100090B-002 | Multi-GNSS |
Standard Accessories
J1705A| AUX Conversion Adaptor
J1886A| GNSS Antenna
J1710A| BNC Cable (20 cm) × 2
Z2122A| Tripod for GNSS Antenna
Mandatory Main Frame Option
MT1000A-005*2| AUX I/O
MU100011A Option
MU100011A-021| SyncE Wander
Model/Order No.| Name
---|---
Extended Warranty Service
MU100090B-ES210| 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100090B-ES310| 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100090B-ES510| 5 Years Extended Warranty Service (standard 1 year + 4 years)
- The MT1000A-005 is mandatory option for use of MU100090B. Confirm if all of MT1000As which you install the MU100090B have MT1000A-005 or not. If they does not have it please contact us.
Adding OTDR Module
When adding the OTDR Module to a previously purchased MT1000A, use the same
procedure as for OTDR Module described on pages 10 thru 17.
Adding MX109020A Option
Requires MX109020A serial number at purchase.
Model | Name | Notes |
---|---|---|
MX109020A-TL001 | Site Over Remote Access 1 Year License | Extends MX109020A |
usage period by 1 year
MX109020A-301| Site Over Remote Access 8 Units| Extends number of instruments
simultaneously controlled by MX109020A to 8 units
MX109020A-302| Site Over Remote Access Unlimited Units| Extends number of
instruments simultaneously controlled by MX109020A to 100 units
MX109020A-303| Centralized Data Management| Supports upload of measurement
report from MT1000A to cloud storage
Configuration Examples
By combining multiple modules, MT1000A can be used as a measuring instrument
suitable for the field. There will introduce a configuration example tailored
to the exam situation.
I &M for Core/Metro Network
Optical fiber check and 100G transport testing
Model | Name |
---|---|
MT1000A | Network Master Pro |
MU100011A | 100G Multirate Module |
MU100011A-015 | Ethernet 100G Single channel |
MU100011A-055 | OTN 100G Single Channel |
G0365A | 100G LR4 Dual Rate 1310 nm QSFP28 |
MU100022A | OTDR Module 1310/1550/1625 nm SMF |
MU100022A-022 | High-Performance Dynamic Range |
MU100022A-010 | UPC Polish |
MU100022A-037 | FC Connector |
MU100022A-002 | Visual Fault Locator |
I &M for Mobile Backhaul
Evaluate SyncE and IEEE 1588 v2 (PTP), and evaluate the time synchronization
accuracy of the network.
Model | Name |
---|---|
MT1000A | Network Master Pro |
MT1000A-005 | AUX I/O |
MU100010A | 10G Multirate Module |
MU100010A-001 | Up to 2.7G Dual Channel |
MU100010A-012 | Ethernet 10G Dual Channel |
G0315A | 10G LR/LW 1310 nm SFP+ |
MU100090B | High Performance GNSS Disciplined Oscillator |
I &M for Data Center
Confirm the data quality inside the station building and the communication
quality with the IX.
Model | Name |
---|---|
MT1000A | Network Master Pro |
MU100011A | 100G Multirate Module |
MU100011A-001 | Up to 10G Dual Channel |
MU100011A-017 | Ethernet 25G Single Channel |
MU100011A-020 | TCP Throughput |
MU100011A-005 | Up to 10G FC Dual Channel |
MU100011A-091 | FC 16G Single Channel |
G0329A | 10G LR 1310 nm SFP+ |
G0356A | 8G FC/10G FC SR 850 nm SFP+ |
G0386A | 16GFC SR 850 nm SFP+ |
G0388A | 25G SR 850 nm QSFP+ |
G0389A | 25G LR 1310 nm QSFP+ |
I &M for Mobile Fronthaul
Evaluate breakage of optical fiber and transmission quality of Ethernet and
CPRI/OBSAI.
Model | Name |
---|---|
MT1000A | Network Master Pro |
MU100010A | 10G Multirate Module |
MU100010A-071 | CPRI/OBSAI Up to 5G Dual Channel |
MU100010A-073 | CPRI/OBSAI 6G to 10G Dual Channel |
G0319A | Up to 2.7G 1310 nm 15 km SFP |
G0329A | 10G LR 1310 nm SFP+ |
MU100021A | OTDR Module 1310/1550 nm SMF |
MU100021A-021 | Standard Dynamic Range |
MU100021A-010 | UPC Polish |
MU100021A-040 | SC Connector |
MU100021A-002 | Visual Fault Locator |
J1534A | LC-SC Plug-in Converter (SC (P)-LC (J) for SM fiber) |
J1535A | LC-SC Plug-in Converter (SC (P)-LC (J) for MM fiber) |
68-10-R | SFP (Optical Module), 3.7 Gbps SFP, 850 nm |
68-6-R | SFP+ (Optical Module), 8G FC/10G SFP, 1310 nm |
Check of Dark Fiber
It will evaluate the disconnection of the dark fiber to be used for the first
time and the optical signal quality.
Model | Name |
---|---|
MT1000A | Network Master Pro |
MU100022A | OTDR Module 1310/1550/1625 nm SMF |
MU100022A-022 | High-Performance Dynamic Range |
MU100022A-010 | UPC Polish |
MU100022A-037 | FC Connector |
MU100022A-002 | Visual Fault Locator |
Order Sheet
When recording different MT1000A configurations on one order sheet, describe
each MT1000A configuration on one line with the accompanying options under the
relevant line.
Model | Name | Quantity |
---|---|---|
MT1000A measurement modules can be removed and changed. Module Configuration
This explains the method and precautions.
-
Step 1 : Version up the software for MT1000A
- Install the latest software in the MT1000A. This software can be obtained from the Anritsu web site.
-
There are two MT1000A installers; download the installer matching the measurement module to be used.
Step 2 : Remove the battery pack from Mainframe
- Disconnect the AC cable.
- Use screw driver or Coin and remove the battery lid from MT1000A.
- Remove the battery pack.
Step 3 : Replacing the connected modules
- Place the instrument on its front on a plain surface. Loosen the screws (shown by the blue circle) on rear side of the connected module.
- After loosing the four screws, lift up the connected module with holding both sides.
- If you cannot lift up, loosen the four screws again. You can see the panel as below.
Step 4 : Attaching the new module and the former module
- Remove four screws of former module and replace to the next screws. Please arrange a screw separately.
- Attach the former module to the new module. Please check modular turn, referring to 3 pages. Place the former module on the new modules as to connect following pairs: Align the four corners when installing the module. At this time, take care not to let connectors 2 and 4 come into contact with guide pins 1, 3, 5, and 6. Doing so may damage the module connectors.
- Tighten the four screws.
After the module attachment has finished, the external appearance will be as below.
Step 5 : After attaching the modules
- After attaching the modules, connect the AC cable or install the battery packs.
- Turn on the MT1000A. Please check whether a new module is recognized at the system information
United States
Anritsu Americas Sales Company
- 450 Century Parkway, Suite 190, Allen, TX 75013 U.S.A.
- Phone: +1-800-Anritsu (1-800-267-4878)
Canada
- Anritsu Electronics Ltd.
- 700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada
- Phone : +1-613-591-2003
- Fax : +1-613-591-1006
Brazil
- Anritsu Eletronica Ltda.
- Praça Amadeu Amaral, 27 – 1 Andar
- 01327-010 – Bela Vista – Sao Paulo – SP, Brazil
- Phone : +55-11-3283-2511
- Fax: +55-11-3288-6940
Mexico
- Anritsu Company, S.A. de C.V.
- Blvd Miguel de Cervantes Saavedra #169 Piso 1, Col. Granada Mexico, Ciudad de Mexico, 11520, MEXICO
- Phone : +52-55-4169-7104
United Kingdom Anritsu EMEA Ltd.
- 200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.
- Phone : +44-1582-433200
- Fax : +44-1582-731303
France Anritsu S.A.
- 12 avenue du Québec, Immeuble Goyave, 91140 VILLEBON SUR YVETTE, France
- Phone : +33-1-60-92-15-50
Germany Anritsu GmbH
- Nemetschek Haus, Konrad-Zuse-Platz 1, 81829 München, Germany
- Phone : +49-89-442308-0
- Fax : +49-89-442308-55
Italy Anritsu S.r.l.
- Spaces Eur Arte, Viale dell’Arte 25, 00144 Roma, Italy
- Phone : +39-6-509-9711
Sweden Anritsu AB
- Kistagången 20 B, 2 tr, 164 40 Kista, Sweden
- Phone: +46-8-534-707-00
Finland
- Anritsu AB
- Technopolis Aviapolis, Teknobulevardi 3-5 (D208.5.), FI-01530 Vantaa, Finland
- Phone : +358-20-741-8100
Denmark
- Anritsu A/S
- c/o Regus Winghouse, Ørestads Boulevard 73, 4th floor,
- 2300 Copenhagen S, Denmark
- Phone : +45-7211-2200
Russia
- Anritsu EMEA Ltd.
- Representation Office in Russia
- Tverskaya str. 16/2, bld. 1, 7th floor., Moscow, 125009, Russia
- Phone : +7-495-363-1694
- Fax : +7-495-935-8962
Spain
- Anritsu EMEA Ltd.
- Representation Office in Spain
- Paseo de la Castellana, 141. Planta 5, Edificio Cuzco IV
- 28046, Madrid, Spain
- Phone : +34-91-572-6761
Austria
- Anritsu EMEA GmbH
- Am Belvedere 10, A-1100 Vienna, Austria
- Phone : +43-(0)1-717-28-710
United Arab Emirates Anritsu EMEA Ltd. Anritsu A/S
- Office No. 164, Building 17, Dubai Internet City
- P. O. Box – 501901, Dubai, United Arab Emirates
- Phone : +971-4-3758479
India
Anritsu India Private Limited
- 6th Floor, Indiqube ETA, No.38/4, Adjacent to EMC2,
- Doddanekundi, Outer Ring Road, Bengaluru – 560048, India
- Phone : +91-80-6728-1300
- Fax : +91-80-6728-1301
Singapore
- Anritsu Pte. Ltd.
- 11 Chang Charn Road, #04-01, Shriro House, Singapore 159640
- Phone : +65-6282-2400
- Fax : +65-6282-2533
Vietnam
- Anritsu Company Limited
- 16th Floor, Peakview Tower, 36 Hoang Cau Street, O Cho Dua Ward,
- Dong Da District, Hanoi, Vietnam
- Phone : +84-24-3201-2730
P.R. China (Shanghai)
- Anritsu (China) Co., Ltd.
- Room 2701-2705, Tower A, New Caohejing International
- Business Center No. 391 Gui Ping Road Shanghai, 200233, P.R. China
- Phone : +86-21-6237-0898
- Fax : +86-21-6237-0899
P.R. China (Hong Kong)
- Anritsu Company Ltd.
- Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza,
- No. 1 Science Museum Road, Tsim Sha Tsui East,
- Kowloon, Hong Kong, P.R. China
- Phone : +852-2301-4980
- Fax : +852-2301-3545
Japan
- Anritsu Corporation
- 8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan
- Phone : +81-46-296-6509
- Fax : +81-46-225-8352
Korea
- Anritsu Corporation, Ltd.
- 5FL, 235 Pangyoyeok-ro, Bundang-gu, Seongnam-si,
- Gyeonggi-do, 13494 Korea
- Phone : +82-31-696-
- Fax : +82-31-696-7751
Australia Anritsu Pty. Ltd.
- Unit 20, 21-35 Ricketts Road, Mount Waverley, Victoria 3149, Australia
- Phone : +61-3-9558-8177
- Fax : +61-3-9558-8255
Taiwan
Anritsu Company Inc.
- 7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan
- Phone : +886-2-8751-1816
- Fax : +886-2-8751-1817
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>