Plastica SSW PUMP 05 Clever Pool Energy Save Inverter Instructions

June 13, 2024
Plastica

Plastica SSW PUMP 05 Clever Pool Energy Save Inverter

Plastica-SSW-PUMP-05-Clever-Pool-Energy-Save-Inverter-
product

Product Information

The Energy Save Inverter is a device used for testing 3-phase motors. It is designed to improve energy efficiency and ensure the safe operation of the motor.

Product Usage Instructions

  1. Only trained personnel are authorized to follow this procedure.
  2. Remove four screws from the motor’s electrical box cover.
  3. Ensure that the Clever Pool energy-saving inverter is disconnected from the power supply.
  4. Connect the earth terminal at the base of the electrical box. Refer to the provided photo for reference.
  5. Connect the black wire to the U terminal, the blue wire to the V terminal, and the red wire to the W terminal. Tighten the brass nuts securely.
  6. Replace the motor electrical box cover.
  7. Plug in the Clever Pool unit and switch it on.
  8. Check that the unit is in manual mode, as indicated in the top right-hand corner.
  9. Set the RPM to 2850 using the up and down arrows.
  10. Push the run/stop button to check the motor function.
  11. If the motor turns in the wrong direction (check the arrow on the side of motor), switch off the unit, unplug it, remove the cover, and reverse the cable connections. Refer to the provided photos for guidance.

Safe System of Work

OPERATING AND SAFETY INSTRUCTIONS FOR USING ENERGY SAVE INVERTERS FOR TESTING 3-PHASE MOTORS
Name: …………………………………………….………….
Training Date:…..…………………………

| Instruction| Understood

or

---|---|---
1| Only trained personnel are authorized to follow this procedure.|
2| Remove four screws from the motor’s electrical box cover.|
3| Ensure the Clever Pool energy save is disconnected from the power supply.|
4| Connect the earth terminal at the base of the electrical box. See photo below:|
5| Connect the black to U, blue to V, and red wires to W terminals and tighten the brass nuts.|
6| Replace cover.|
7| Plug in the Clever Pool unit and switch on.|
8| Check the unit is in manual mode. (Top right-hand corner) RPM is set to 2850 by use of up and down arrows.|
9| Push the run/stop button to check the motor function. If the motor turns in the wrong direction (check the arrow on the side of the motor) switch it off, unplug the unit, remove the cover, and reverse the cable connections.
See photos below:Plastica-SSW-PUMP-05-Clever-Pool-Energy-Save-Inverter-
fig-4PUMP DIRECTION: CHANGE TERMINALS IF: NEW POSITIONS|
| DIRECTION IS WRONG

Replace the cover, plug in the unit, and switch on. The motor should now be running in the correct direction.

---|---
10| Push the stop button to end the test. N.B. Do not run the pump in a dry state for any longer than necessary.
11| Disconnect the Clever Pool unit from power.
12| Disconnect cables and replace the electrical cover.

  • have received the above training and fully understand every point that was explained to me. I confirm that I will wear the required PPE equipment when using the above machinery and take all steps to ensure my own safety. I will ask for further training if I need to and will immediately inform the Supervisor or Manager if there are any issues with the machinery.
  • Name : ………………………………………………………
  • Signed : ……………………………………………………
  • Date: ………………………………………………………
  • I confirm that I have trained the aforementioned person and that they fully understand how to use the above machinery, have received the required PPE equipment, and know to inform me immediately of any issues with the machinery or if they require further training. I authorize this person to use the machinery detailed above.
  • Name: … ………………………………………………………
  • (Authorised Trainer)
  • Signed … ………………………………………………………
  • Date: … ………………………………………………………..

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals