Annritsu MU104014A Network Master Pro User Guide
- June 13, 2024
- Annritsu
Table of Contents
MU104014A Network Master Pro
Product Information
The Network Master Pro MT1040A is a multiplatform device
designed for field testing. It consists of a main frame and various
measurement modules that can be configured to match the user’s
testing requirements. The main frame controls the test modules,
which can be changed freely to create a custom configuration.
The MT1040A features a 9-inch active TFT display with a touch
screen interface. It also includes a power switch for easy
operation.
The product comes with standard accessories, including a high
power supply, line cord, soft case, rear panel kit, AC adaptor,
Li-ion battery, quick reference guide, stylus, utilities ROM, and
handle.
Additional software options are available for the MT1040A,
including connectivity for WLAN/Bluetooth and site over remote
access connect.
The product supports module configurations for different
transport and optical measurements. These include 400G (QSFP-DD)
multirate module, 400G (OSFP) multirate module, 100G multirate
module, 10G multirate module, and OTDR module.
Product Usage Instructions
-
Connect the mainframe to a power source using the provided AC
adapter. -
Attach the desired measurement modules to the mainframe by
inserting them into the appropriate slots. -
If using the OTDR module, connect the necessary fiber optic
cables to the module. -
Turn on the power switch located on the mainframe.
-
Use the touch screen interface to navigate through the
different measurement options and select the desired test
parameters. -
Follow the on-screen instructions to perform the desired tests
and measurements. -
If using any optional software features, access them through
the menu and configure them according to your needs. -
Refer to the provided quick reference guide and utilities ROM
for additional guidance on using the product. -
After completing the tests, power off the mainframe and
disconnect it from the power source.
Configuration Guide
Network MasterTM Series
Network Master Pro MT1040A
400G (QSFP-DD) Multirate Module
MU104014A
400G (OSFP) Multirate Module
MU104015A
100G Multirate Module
MU104011A/MU100011A
10G Multirate Module
MU100010A
OTDR Module
MU100020A/MU100021A/MU100022A/MU100023A
Contents
The MT1040A is configured as a combination of various measurement modules. It
is designed to support a combination of selected measurement modules and
options with the main unit.
Contents
Network Master Pro MT1040A Main Frame
………………………………………………………………………………………………………………………………………………………………………………………………………….3
New Purchase Flowchart
…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………..4
New Purchase
……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………..6
Transport Module
………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….6
1-1 400G (QSFP-DD) Multirate Module MU104014A
………………………………………………………………………………………………………………………………………………………………………………6 1-1-1
Selecting Protocol
Options……………………………………………………………………………………………………………………………………………………………………………………………………………..6
1-2 400G (OSFP) Multirate Module
MU104015A………………………………………………………………………………………………………………………………………………………………………………………7
1-2-1 Selecting Protocol
Options……………………………………………………………………………………………………………………………………………………………………………………………………………..7
1-3 100G Multirate Module MU104011A
…………………………………………………………………………………………………………………………………………………………………………………………………..8
1-3-1 Selecting Protocol
Options……………………………………………………………………………………………………………………………………………………………………………………………………………..8
1-4 10G Multirate Module
MU100010A……………………………………………………………………………………………………………………………………………………………………………………………………..9
1-4-1 Selecting Protocol
Options……………………………………………………………………………………………………………………………………………………………………………………………………………..9
1-5 100G Multirate Module MU100011A
……………………………………………………………………………………………………………………………………………………………………………………………….. 10
1-5-1 Selecting Protocol
Options…………………………………………………………………………………………………………………………………………………………………………………………………………..
10 1-6 Selecting Optical Transceiver for Transport
Module……………………………………………………………………………………………………………………………………………………………………….. 11 1-7
Selecting Transport Test
Option………………………………………………………………………………………………………………………………………………………………………………………………………….
12
OTDR
Module………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………13
2-1 OTDR Module 1310/1550 nm SMF MU100020A
……………………………………………………………………………………………………………………………………………………………………………. 13 2-1-1
Selecting Dynamic Range
…………………………………………………………………………………………………………………………………………………………………………………………………………….
13 2-1-2 Selecting Polish Type/Connector
Adapter………………………………………………………………………………………………………………………………………………………………………………… 13
2-1-3 Selecting Visible Light Source
Option………………………………………………………………………………………………………………………………………………………………………………………..
13 2-2 OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A
………………………………………………………………………………………………………………………………………………. 14 2-2-1 Selecting
Dynamic Range
…………………………………………………………………………………………………………………………………………………………………………………………………………….
14 2-2-2 Selecting Polish Type/Connector
Adapter………………………………………………………………………………………………………………………………………………………………………………… 14
2-2-3 Selecting Visible Light Source
Option………………………………………………………………………………………………………………………………………………………………………………………..
14 2-3 OTDR Module 1310/1550/1625 nm SMF
MU100022A………………………………………………………………………………………………………………………………………………………………….. 15
2-3-1 Selecting Dynamic Range
…………………………………………………………………………………………………………………………………………………………………………………………………………….15
2-3-2 Selecting Polish Type/Connector
Adapter………………………………………………………………………………………………………………………………………………………………………………… 15
2-3-3 Selecting Visible Light Source
Option………………………………………………………………………………………………………………………………………………………………………………………..
15 2-4 OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A
………………………………………………………………………………………………………………………………………………………….. 16 2-4-1
Selecting Dynamic Range
…………………………………………………………………………………………………………………………………………………………………………………………………………….
16 2-4-2 Selecting Polish Type/Connector
Adapter………………………………………………………………………………………………………………………………………………………………………………… 16
2-4-3 Selecting Visible Light Source
Option………………………………………………………………………………………………………………………………………………………………………………………..
16 2-5 Selecting MU100020A/MU100021A/MU100022A/MU100023A
Options……………………………………………………………………………………………………………………………………. 17 2-5-1 OTDR
Module Conversion Connector Adapters
……………………………………………………………………………………………………………………………………………………………………… 17 2-5-2
Optical Fiber Conversion
Adapters……………………………………………………………………………………………………………………………………………………………………………………………..
17 2-5-3 Others
……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………..
17
Common Application Parts, Extended Warranty Services and Remote Software
Service……………………………………………………………………………………………………………………… 18 3-1 MT1040A Power
Supply Option
………………………………………………………………………………………………………………………………………………………………………………………………………….
18 3-2 MT1040A Selecting Common Application
Parts………………………………………………………………………………………………………………………………………………………………………………. 18
3-3 MT1040A Selecting Extended Warranty
Services…………………………………………………………………………………………………………………………………………………………………………….. 20
3-4 Remote Software
Service………………………………………………………………………………………………………………………………………………………………………………………………………………………
21
Additional Purchases
Flowchart…………………………………………………………………………………………………………………………………………………………………………………………………………………………….
22 Additional Purchases
………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………
24
Adding New Options to Previously Purchased MT1040A
…………………………………………………………………………………………………………………………………………………………………………… 24 4-1
Adding Test Protocols for Transport
Module…………………………………………………………………………………………………………………………………………………………………………………… 24
4-2 Adding Main Frame Options for Transport Function
……………………………………………………………………………………………………………………………………………………………………… 29 4-3 Adding
Transport
Module…………………………………………………………………………………………………………………………………………………………………………………………………………………….
29 4-4 Adding OTDR Module
………………………………………………………………………………………………………………………………………………………………………………………………………………………….
29 4-5 Adding MX109020A
Option…………………………………………………………………………………………………………………………………………………………………………………………………………………
29
Configuration Examples
…………………………………………………………………………………………………………………………………………………………………………………………………………………………………….
30 Order Sheet
………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….31
Method for Adding Measurement
Modules…………………………………………………………………………………………………………………………………………………………………………………………………..
32
2
Network Master Pro MT1040A Main Frame
Network Master Pro MT1040A: Main Frame
The Network Master Pro MT1040A is a multiplatform designed for field testing
that is configured using a combination of transport and optical. The Main
Frame controls the test modules which can be changed freely to any custom
configuration matching the users testing requirements.
9-inch active TFT display and touch screen
Power switch
MT1040A Main Unit
Model/Order No. MT1040A
MT1040A-006
B0745A B0771A*3 G0418A G0413A W4039AE Z1746A Z2077A Z2082A
Name Network Master Pro
Standard Accessories
High Power Supply1: Line Cord2: Softcase: MT1040A Rear Panel kit: AC
Adaptor: Li-ion Battery: Quick Reference Guide: Stylus: Utilities ROM: Handle:
1 pc 1 pc 1 pc 1 pc 1 pc 2 pcs 1 pc 1 pc 1 pc 1 pc
Software Option*4
Model/Order No. MT1040A-003*5 MT1040A-011
Name Connectivity for WLAN/Bluetooth Site Over Remote Access Connect
AUX (D-SUB 15 pin)
Clock Input
DC Input (19 Vdc)
USB A USB Ethernet Service Interface Mini-B
*1: The presence of the MT1040A-006 option can be recognized at the top right
of the front panel. To retrofit it, please contact sales representative.
Without MT1040A-006
With in MT1040A-006
2: One line cord is attached to the area to shipment. 3: Composed of B0720A, B0730A, B0731A, B0740A and B0741A.
Module Configuration
Option for Two Transport Modules*6
Model/Order No. MT1040A-020
Name Activate for 400G Dual/100G Quad Option
Standard Accessories
G0419A
AC Adapter (400 W)
*4: These options can be retrofitted.
The Model/Order No. of retrofit options is “-3*”. Example
MT1040A-003 Connectivity for WLAN/Bluetooth becomes MT1040A-303 Connectivity
for WLAN/Bluetooth Retrofit. When retrofitting an option, please either
specify one of the following media along with the relevant option, or Web
download.
Z1849A: DVD-ROM for Retrofit Options Z1850A: USB Stick for Retrofit Options
5: WLAN is available for certified countries and regions including USA, Japan and
EU countries. Please visit the Anritsu web site for updated information.
*6: Can be added to main unit in which MT1040A-006 already installed. However,
battery operation is not possible when installing two transponder modules
together.
2U
400G (QSFP-DD) Multirate Module MU104014A 400G (OSFP) Multirate Module MU104015A
100G Multirate Module MU104011A
10G Multirate Module MU100010A
3U
100G Multirate Module MU100011A
1310/1550 nm SMF MU100020A 1310/1550/850/1300 nm SMF/MMF MU100021A 1310/1550/1625 nm SMF MU100022A 1310/1550/1650 nm SMF MU100023A
4U
5U
3
New Purchase Flowchart
Use this flowchart to select options when purchasing a new MT1040A.
MT1040A Choose the mainframe and mainframe options.
Page 3
Select testing requirements Confirming comms quality such as OTN, Ethernet, etc.
Select the type of interface to measure (10G) Up to 10G including PDH with independent dual port. (100G Single) 100G, 40G and 25G with single port. Up to 10G are with two ports which are restricted to be same protocol(Ethernet, OTN, FC, SDH/SONET) (100G Dual) Up to 100G with independent dual port. (200G/400G) 200G/400G single port.
10G
100G Single
100G Dual
200G/400G
Choose MU100010A Page 9
Choose MU100011A Page 10
Unit size:
1U
Choose MU104011A Page 8
Choose MU104014A for QSFP-DD 400G/200G 100G Dual
Page 6
Choose MU104015A for OSFP, 400G, 100G Single
Page 7
Unit size:
2U
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-4-1 Selecting Protocol Options.
Page 9
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-5-1 Selecting Protocol Options.
Page 10
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-3-1 Selecting Protocol Options.
Page 8
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-1-1 (MU104014A) or 1-2-1 (MU104015A) Selecting
Protocol Options.
Page 6, 7
Select Optical I/F Select the model for choosing the optical module frequency
and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.
Select Transport Test Options Select the model for choosing the required
options from 1-7 Selecting Transport Test Option.
Page 11 Page 12
Selecting Main Frame Accessories Check the main frame power supply from 3-1
MT1040A power supply option. Select the main frame application parts from 3-2
MT1040A Selecting Common Application Parts. Select the model from 3-4 Remote
Software Service. Select the model for the extended hardware warranty from 3-3
MT1040A Selecting Extended Warranty
Page 18 to 21
Record the purchased model and name in the MT1040A configuration confirmation order sheet.
Page 30
4
Checking optical fiber breaks and quality
Select Optical Fiber Select the type of optical fiber to measure Single Model
only Both Single and Multimode fiber
Single Model only
Both Single and Multimode fiber
2 Wavelength (1310/1550 nm)
Choose MU100020A Page 13
Wavelength select
3 Wavelength (1310/1550/ 1625 nm)
Choose MU100022A Page 15
3 Wavelength (1310/1550/ 1650 nm)
Choose MU100023A Page 16
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-1-1 Selecting Dynamic Range.
Page 13
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-3-1 Selecting Dynamic Range.
Page 15
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-4-1 Selecting Dynamic Range.
Page 16
Select Connector Select the model with the required connector type from 2-1-2
Selecting Polish Type/ Connector Adapter.
Page 13
Select Connector Select the model with the required connector type from 2-3-2
Selecting Polish Type/ Connector Adapter.
Page 15
Select Connector Select the model with the required connector type from 2-4-2
Selecting Polish Type/ Connector Adapter.
Page 16
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-1-3 Selecting Visible Light Source Option.
Page 13
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-3-3 Selecting Visible Light Source Option.
Page 15
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-4-3 Selecting Visible Light Source Option.
Page 16
Selecting OTDR Test Options Select the models with the option choices from
2-5-1 OTDR Module Conversion Connector Adapters, 2-5-2 Optical Fiber
Conversion Adapters, and 2-5-3 Others.
Page 17
Choose MU100021A Page 14
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-2-1 Selecting Dynamic Range.
Page 14
Unit size:
1U
Select Connector Select the model with the required connector type from 2-2-2
Selecting Polish Type/ Connector Adapter.
Page 14
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-2-3 Selecting Visible Light Source Option.
Page 14
5
New Purchase
Transport Module
1-1 400G (QSFP-DD) Multirate Module MU104014A
Model/Order No.
Name
MU104014A
400G (QSFP-DD) Multirate Module
Standard Accessories
B0768A
ESD Box:
1 pc
The 400G (QSFP-DD) Multirate Module MU104014A supports
W4039AE
Transport Module Quick Reference Guide:
1 pc
communications network technologies from 10 Mbps to 100 Gbps with
dual ports and from 200 Gbps to 400 Gbps with single port. It has the
functions and performance required for network I&M tests. In addition,
optional test protocols can be selected and added. This excellent
expandability helps cut initial capital costs and supports introduction of
new functions matching the work schedule.
1-1-1 Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU104014A Transport Technology Ethernet
Bit Rate
No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-XDR4 N-Port BERT eCPRI/RoE
(IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring
using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event
Generation, Tributary Scan
10G or less 2 (Dual Channel)
16G or 25G 2 (Dual Channel)
MU104014A-012 Ethernet up to 25G Dual Channel
MU104014A-012
Ethernet up to 25G
—
Dual Channel
MU104014A-020
—
TCP Throughput*2
—
—
MU104014A-012 Ethernet up to 25G Dual Channel
MU104014A-052
—
OTN up to 10G
Dual Channel
—
MU104014A-063
ODU Multiplexing/
—
Multi Stage*3
MU104014A-074 CPRI/OBSAI up to 25G Dual Channel
MU104014A-092 FC up to 16G Dual Channel
MU104014A-082
SDH/SONET up to
—
10G Dual Channel
40G or 100G 1 (Single Channel) 2 (Dual Channel)
MU104014A-013 Ethernet 40G Single Channel
MU104014A-015 Ethernet 100G Single Channel
MU104014A-014 Ethernet 40G Dual Channel
MU104014A-016 Ethernet 100G Dual Channel
—
—
—
—
—
—
MU104014A-013
Ethernet 40G Single Channel
MU104014A-015
Ethernet 100G Single Channel
MU104014A-014
Ethernet 40G Dual Channel
MU104014A-016
Ethernet 100G Dual Channel
MU104014A-053 OTN 40G
Single Channel
MU104014A-055 OTN 100G
Single Channel
MU104014A-054 OTN 40G
Dual Channel
MU104014A-056 OTN 100G
Dual Channel
MU104014A-063 ODU Multiplexing/Multi Stage*3
—
—
—
—
MU104014A-084*4 STM-256/OC-768 Client Signal
200G or 400G 1 (Single Channel) MU104014A-031
Ethernet 200G Single Channel MU104014A-033 Ethernet 400G Single Channel
— — MT104014A-034 4×100G N Port BERT
—
—
—
—
—
—
—
—
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104014A-012. 3: Requires that at least one of the following option is installed: MU104014A-052, MU104014A-053, MU104014A-054, MU104014A-055, MU104014A-056. 4: MU104014A does not have a physical interface of the option. The option is required for client signal mapped in the OTN. 6
New Purchase
Transport Module
1-2 400G (OSFP) Multirate Module MU104015A
Model/Order No.
Name
MU104015A
400G (OSFP) Multirate Module
Standard Accessories
B0768A
ESD Box:
1 pc
The 400G (OSFP) Multirate Module MU104015A supports communications
W4039AE
Transport Module Quick Reference Guide:
1 pc
network technologies from 10 Mbps to 25 Gbps with dual ports and
from 40 Gbps to 400 Gbps with single port. It has the functions and
performance required for network I&M tests. In addition, optional test
protocols can be selected and added. This excellent expandability helps
cut initial capital costs and supports introduction of new functions
matching the work schedule.
1-2-1 Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU104015A Transport Technology Ethernet
Bit Rate
No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-2FR4 N-Port BERT eCPRI/RoE
(IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors
Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER
Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error
Monitoring
SDH/SONET
Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test,
Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan
10G or less 2 (Dual Channel)
16G or 25G 2 (Dual Channel)
MU104015A-012 Ethernet up to 25G Dual Channel
MU104015A-012
Ethernet up to 25G
—
Dual Channel
MU104015A-020 TCP Throughput*2
—
—
—
MU104015A-012 Ethernet up to 25G Dual Channel
MU104015A-052
—
OTN up to 10G
Dual Channel
—
MU104015A-063
ODU Multiplexing/
—
Multi Stage*3
MU104015A-074 CPRI/OBSAI up to 25G Dual Channel
MU104015A-092 FC up to 16G Dual Channel
MU104015A-082
SDH/SONET up to
—
10G Dual Channel
40G or 100G 1 (Single Channel) 2 (Dual Channel)
MU104015A-013
Ethernet 40G
—
Single Channel
MU104015A-015
Ethernet 100G
—
Single Channel
—
—
—
—
—
—
MU104015A-013
Ethernet 40G
—
Single Channel
MU104015A-015
Ethernet 100G
—
Single Channel
MU104015A-053
OTN 40G
—
Single Channel
MU104015A-055
OTN 100G
—
Single Channel
MU104015A-063
ODU Multiplexing/
—
Multi Stage*3
—
—
—
—
MU104015A-084*4 STM-256/OC-768 Client Signal
400G 1 (Single Channel)
— MU104015A-033
Ethernet 400G Single Channel
— — MU104015A-035 2×200G N Port BERT — —
— — —
—
—
—
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104015A-012. 3: Requires that at least one of the following option is installed: MU104015A-052, MU104015A-053, MU104015A-055. 4: MU104015A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
7
New Purchase
Transport Module
1-3 100G Multirate Module MU104011A
Model/Order No.
Name
MU104011A
100G Multirate Module
Standard Accessories
B0768A
ESD Box:
1 pc
The 100G Multirate Module MU104011A supports communications
W4039AE
Transport Module Quick Reference Guide:
1 pc
network technologies from 10 Mbps to 100 Gbps with dual ports. It has
the functions and performance required for network I&M tests.
In addition, optional test protocols can be selected and added.
This excellent expandability helps cut initial capital costs and supports
introduction of new functions matching the work schedule.
1-3-1 Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU104011A Transport Technology Ethernet
Bit Rate
No. of Measurement Ports*1
10G or less 2 (Dual Channel)
16G or 25G 2 (Dual Channel)
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
MU104011A-012 Ethernet up to 25G Dual Channel
Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) eCPRI/RoE (IEEE1914.3)
MU104011A-012
Ethernet up to 25G
—
Dual Channel
MU104011A-020
—
TCP Throughput*2
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
MU104011A-012 Ethernet up to 25G Dual Channel
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring
using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event
Generation, Tributary Scan
MU104011A-052
—
OTN up to 10G
Dual Channel
—
MU104011A-063
ODU Multiplexing/
—
Multi Stage*3
MU104011A-074 CPRI/OBSAI up to 25G Dual Channel
MU104011A-092 FC up to 16G Dual Channel
MU104011A-082
SDH/SONET up to 10G
—
Dual Channel
40G or 100G
1 (Single Channel)
2 (Dual Channel)
MU104011A-013 Ethernet 40G Single Channel
MU104011A-015 Ethernet 100G Single Channel
—
—
MU104011A-014 Ethernet 40G Dual Channel
MU104011A-016 Ethernet 100G Dual Channel
—
—
MU104011A-013 Ethernet 40G Single Channel
MU104011A-015 Ethernet 100G Single Channel
MU104011A-014 Ethernet 40G Dual Channel
MU104011A-016 Ethernet 100G Dual Channel
MU104011A-053 OTN 40G Single Channel
MU104011A-055 OTN 100G Single Channel
MU104011A-054 OTN 40G Dual Channel
MU104011A-056 OTN 100G Dual Channel
MU104011A-063 ODU Multiplexing/Multi Stage*3
—
—
—
—
MU104011A-084*4 STM-256/OC-768 Client Signal
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104011A-012. 3: Requires that at least one of the following option is installed: MU104011A-052, MU104011A-053, MU104011A-054, MU104011A-055, MU104011A-056. 4: MU104011A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
8
New Purchase
Transport Module
1-4 10G Multirate Module MU100010A
The 10G Multirate Module MU100010A supports communications network technologies with speeds ranging from 1.5 Mbps to 10 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.
Model
Name
MU100010A
10G Multirate Module
Standard Accessories
W3935AE B0692A*
MT1000A Transport Quick Reference Guide:
1 pc
ESD Box (for optical modules):
1 pc
*: Up to four SFP+/SFPs can be stored.
1-4-1 Selecting Protocol Options
The protocol options are software options for transport technologies
supporting each bit rate. At least one Channel option must be selected from
the following list.
MU100010A
Bit Rate
Transport Technology
No. of Measurement Ports*1
Ethernet
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through, Channel Stat
TCP Throughput Test (RFC 6349, iPerf)
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition4
ODU Flex Addition5
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors
Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER
Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error
Monitoring
SDH/SONET, PDH/DSn
PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event
Generation, Tributary Scan
Less than 5G 2 (Dual Channel)
From 6G to 10G
1 (Single Channel)
2 (Dual Channel)
MU100010A-001 Up to 2.7G Dual Channel
MU100010A-011 Ethernet 10G Single Channel
MU100010A-012 Ethernet 10G Dual Channel
MU100010A-020 TCP Throughput
MU100010A-001 Up to 2.7G Dual Channel
MU100010A-011 Ethernet 10G Single Channel
MU100010A-012 Ethernet 10G Dual Channel
MU100010A-001 Up to 2.7G Dual Channel
MU100010A-051 OTN 10G Single Channel
MU100010A-052 OTN 10G Dual Channel
MU100010A-061 ODU Multiplexing
—
MU100010A-062 ODU Flex
MU100010A-071
CPRI/OBSAI Up to 5G Dual Channel
MU100010A-072
CPRI/OBSAI 6G to 10G Single Channel
MU100010A-073
CPRI/OBSAI 6G to 10G Dual Channel
MU100010A-002 FC 1G 2G 4G Dual Channel
MU100010A-091 FC 8G 10G Single Channel
MU100010A-092 FC 8G 10G Dual Channel
MU100010A-001 Up to 2.7G Dual Channel
MU100010A-081
STM-64 OC-192 Single Channel
MU100010A-082
STM-64 OC-192 Dual Channel
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Please see the datasheet for supported OTN mapping. 3: When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the
MU100010A-051/052 (for physical port) and the MU100010A-081/082 (for client
signal) are required.
4: When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel.
*5: When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.
9
New Purchase
Transport Module
1-5 100G Multirate Module MU100011A
The 100G Multirate Module MU100011A supports communications network technologies with speeds ranging from 10 Mbps to 100 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.
Model
Name
MU100011A
100G Multirate Module
Standard Accessories
W3935AE
MT1000A Transport Quick Reference Guide:
1 pc
B0763A*
ESD Box (for optical modules):
1 pc
*: One CFP4 plus either up to two QSFP28s or up to four SFP/SFP+s can be
stored.
1-5-1 Selecting Protocol Options
The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.
MU100011A Transport Technology Ethernet
Bit Rate No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery
Pass-through, Channel Stat TCP Throughput Test (RFC 6349, iPerf)
Measurement using 100GBASE-SR
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
Measurement using 100GBASE-SR
OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan ODU
Multiplexing Addition2, 4 ODU Flex Addition2, 5 CPRI/OBSAI CPRI/OBSAI L1:
Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre
Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line
Alarm/Error Monitoring SDH/SONET PDH/DSn Test, Tw-Way Monitoring/Mapping,
Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/Generation,
Pointer Event Generation, Tributary Scan
Up to 10G
1
2
(Single Channel) (Dual Channel)
Higher than 10G
1
2
(Single Channel)
(Dual Channel)
MU100011A-017*8 Ethernet 25G Single Channel
—
MU100011A-001 MU100011A-003
MU100011A-013*9
Up to 10G
Up to 10G
Ethernet 40G Single Channel
—
Single Channel
Dual Channel
MU100011A-015*9 Ethernet 100G Single Channel
—
—
—
MU100011A-020 TCP Throughput
—
—
MU100011A-023*8
RS-FEC for 100GBASE-SR4
—
—
—
MU100011A-015*9
Ethernet 100G Single Channel
MU100011A-001 MU100011A-003
Up to 10G
Up to 10G
Single Channel
Dual Channel
—
—
MU100011A-0178 Ethernet 25G Single Channel
MU100011A-0139 Ethernet 40G Single Channel
MU100011A-0159 Ethernet 100G Single Channel
MU100011A-0238 RS-FEC for 100GBASE-SR4
MU100011A-015*9 Ethernet 100G Single Channel
MU100011A-0757, 8 eCPRI/RoE 25G Dual Channel
— —
—
MU100011A-001 MU100011A-003
Up to 10G
Up to 10G
Single Channel
Dual Channel
MU100011A-053 OTN 40G Single Channel
MU100011A-055 OTN 100G Single Channel
— —
MU100011A-063 ODU Multiplexing/Multi Stage
MU100011A-062 ODU Flex
—
MU100011A-071 CPRI/OBSAI Up to 10G
Single Channel
MU100011A-072 CPRI/OBSAI Up to 10G Dual Channel
MU100011A-073 CPRI 12/25G Single Channel
MU100011A-074 CPRI 12/25G Dual Channel
MU100011A-004 MU100011A-005
Up to 10G FC
Up to 10G FC
Single Channel
Dual Channel
MU100011A-091 FC 16G Single Channel
—
MU100011A-001 MU100011A-003
MU100011A-083*6
Up to 10G
Up to 10G
STM-256/OC-768
—
Single Channel
Dual Channel
Client Signal
*1:
The channel is not related to the physical port position. choose either of the two physical ports assigned to the
The user can freely option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate simultaneously.
**23::
Please see the datasheet for supported OTN mapping. When using the OTN function, the channel can be used mapped to OTN.
as
client
signal
For example, when mapping STM-256/OC-768 to OTU4, both the MU100011A-055
(for physical port) and the MU100011A-083 (for client signal) are required.
*4:
When the ODU Multiplexing/Multistage mapping measurements are supported.
option
is
installed,
OTN
multistage
This one option supports both single channel and dual channel.
10
*5:
This over
mapping function is based on the ODU Flex standard for OTN networks and supports client signals of any speed.
transmissions
This one option supports both single channel and dual channel.
*6: The MU100011A has no STM-256/OC-768 PHY interface; it can be used for
OTN client signals.
***789:::
Option supports eCPRI/RoE FEC selectable On/Off. FEC is always Off.
protocol
tests
only.
New Purchase
Transport Module
1-6 Selecting Optical Transceiver for Transport Module When using any
transport modules for testing optical interfaces, perform the test by
installing the optical modules matching the test standards in the QSFP-
DD/OSFP/QSFP28/SFP/SFP+/SFP28 slots. The following table lists the modules and
supported standards.
MU104014A MU104015A MU104011A MU100010A MU100011A 100M Ethernet 156M STM-1 614M CPRI 622M STM-4 768M OBSAI 1GFC 1.23G CPRI 1.25G Ethernet 1.54G OBSAI 2GFC 2.46G CPRI 2.488G STM-16 2.67G OTU1 3.07G CPRI OBSAI 4GFC 4.92G CPRI 6.14G CPRI OBSAI 8GFC 9.83G CPRI 9.95G STM-64 10.1G CPRI 10.3G Ethernet 10GFC 10.7G OTU2 11.05G OTU1e 11.09G OTU2e 11.27G OTU1f 11.3G OTU2f 16GFC 25G Ethernet 40G Ethernet 40G OTN 100G Ethernet 100G OTN 200G Ethernet 400G Ethernet
Model/ Order
No.
Name
Form Factor
G0332A
100M FX 1310 nm MM SFP
SFP
G0319A
Up to 2.7G 1310 nm 15 km SFP
SFP
G0320A
Up to 2.7G 1310 nm 40 km SFP
SFP
G0321A
Up to 2.7G 1550 nm 80 km SFP
SFP
G0328A
1G/2G/4G FC 850 nm SFP
SFP
G0322A
1G/2G/4G FC 1310 nm SFP
SFP
G0323A
1G/2G/4G FC 1550 nm SFP
SFP
G0315A
10G LR/LW 1310 nm SFP+
SFP+
G0316A
10G ER/EW 1550 nm 40 km SFP+
SFP+
G0318A
10G ZR/ZW 1550 nm 80 km SFP+
SFP+
G0329A
10G LR 1310 nm SFP+
SFP+
G0356A
8G FC/10G SR 850 nm SFP+
SFP+
G0386A
16GFC SR 850 nm SFP+
SFP+
1310 nm, MM, 2 km
G0387A
16GFC LR 1310 nm SFP+
SFP+
G0388A
25G SR 850 nm SFP28
SFP28
G0389A
25G LR 1310 nm SFP28
G0359A
40G SR4 850 nm QSFP+
G0334A
40G LR4 1310 nm QSFP+
G0366A
100G SR4 850 nm QSFP28
SFP28 QSFP+ QSFP+ QSFP28
G0364A
100G LR4 1310 nm QSFP28
G0365A
100G LR4 Dual Rate 1310 nm QSFP28
G0426A
QSFP28 100GBASE-DR
QSFP28 QSFP28 QSFP28
G0427A
QSFP28 100GBASE-FR1
QSFP28
G0421A
QSFP56 200GBASE-LR4
QSFP56
G0420A
QSFP56 200GBASE-FR4
QSFP56
G0402A
QSFP-DD 400GBASE-DR4
QSFP-DD
G0403A
QSFP-DD 400GBASE-FR4
QSFP-DD
G0404A
QSFP-DD 400GBASE-LR4
QSFP-DD
G0405A
OSFP 400GBASE-DR4
OSFP
G0406A
OSFP 400GBASE-FR4
OSFP
G0425A
QSFP 400GBASE-2FR4
OSFP
G0428A
QSFP-DD 400GBASE-DR4+
QSFP-DD
1310 nm, SM, 15 km 1310 nm, SM, 40 km 1550 nm, SM, 80 km
850 nm, MM, 0.5 km 1310 nm, SM, 10 km 1550 nm, SM, 40 km
1310 nm, SM, 10 km
1310 nm, SM, 10 km 1550 nm, SM, 40 km 1550 nm, SM, 80 km
850 nm, MM, 0.3 km
850 nm, MM, 0.5 km 1310 nm, SM, 10 km
850 nm, MM, 0.5 km 1310 nm, SM, 10 km
850 nm, MM, 0.1 km 1310 nm, SM, 10 km
850 nm, MM, 0.1 km 1310 nm, SM, 10 km 1310 nm, SM, 10 km 1310 nm, SM, 0.5 km
1310 nm, SM, 2 km
1310 nm, SM, 10 km 1310 nm, SM, 2 km
1310 nm, SM, 0.5 km 1310 nm, SM, 2 km 1310 nm, SM, 10 km 1310 nm, SM, 0.5 km
1310 nm, SM, 2 km 1310 nm, SM, 2 km 1310 nm, SM, 0.5 km
11
New Purchase
Transport Module
1-7 Selecting Transport Test Option
These options are used in combination with the transport module. Choose options matching the customer’s test requirements. Additionally today, these options cannot be used in combination with the OTDR module.
Model G0325A
GPS Receiver
Name
Notes It is required when measuring one-way latency at Ethernet tests.
W4038AE W4041AE Z1821A J1583A J1584A
MT1040A Transport Module Operation Manual MT1000A/MT1100A/MT1040A Remote Scripting Operation Manual Utilities in USB Stick Optical Attenuator 10 dB LC/PC to LC/PC RJ45 Cable 3 m
Printed manual Printed manual USB memory with operation manual, remote scripts instruction manual, etc.
J1585A J1586A J1588A J1589A J1591A
RJ48 to Crocodile Clips Cable 3 m RJ48 to Crocodile Clips Cable 20 dB ATT 3 m BNC Cable 2.5 m BNC to 1.6/5.6 Cable 2.5 m RJ48 to Two 3-pin Banana Plug Cable 2.5 m
E1 interface cable. E1 interface cable. E1, E3, E4, DS3, STM-1e, STS-3 interface cable. Impedance: 75 E1, E3, E4, DS3, STM-1e, STS-3 interface cable. Impedance: 75 E1 interface cable.
J1597A J1598A
RJ48 Balanced PDH Cable Crossed 3 m Bantam Cable 3 m
E1 interface cable. DS1 interface cable.
12
New Purchase
OTDR Module
2-1 OTDR Module 1310/1550 nm SMF MU100020A
OPM Port
SM Port
Model
Name
MU100020A
OTDR Module 1310/1550 nm SMF
Standard Accessories
J1693A
Universal Connector 2.5 mm for OPM:
1 pc
The OTDR Module 1310/1550 nm SMF MU100020A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR, FTTA, and
J1694A
Universal Connector 1.25 mm for OPM:
1 pc
OLTS measurements required for checking optical fiber. Select a model
W3811AE
Quick Reference Guide:
1 pc
with the dynamic range matching the test requirements. Additionally,
combined used with the visible light source options support visual
confirmation of fiber breaks, etc.
2-1-1 Selecting Dynamic Range
The MU100020A is available in three models with different dynamic ranges matching the test environment. Select the One matching the test requirements.
Wavelength: Dynamic Range 1310/1550 nm: 39/37.5 dB 1310/1550 nm: 42/41 dB 1310/1550 nm: 46/46 dB
MU100020A-020 MU100020A-021 MU100020A-022
Model
Name Standard Dynamic Range Enhanced Dynamic Range High-Performance Dynamic Range
2-1-2 Selecting Polish Type/Connector Adapter The MU100020A is available in a
total of five models (3 UPC and 2 APC) as listed below. Specify the required
connector type at ordering. The specified connector is provided as a standard
accessory. The polish type cannot be changed after purchase.
Polish Type
UPC
APC
Connector Adapter
Model
UPC Ultra Physical Contact
Model
APC Angled Physical Contact
FC Connector
MU100020A-010 MU100020A-037
MU100020A-011 MU100020A-025
DIN 47256 Connector
MU100020A-010 MU100020A-039
SC Connector
MU100020A-010 MU100020A-040
MU100020A-011 MU100020A-026
2-1-3 Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.
Model MU100020A-002
Name Visual Fault Locator
Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm
J1335A
MU/LC Connector Adapter
Required conversion adapter for inserting LC (1.25 mm) optical fiber
13
New Purchase
OTDR Module
2-2 OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A
OPM Port
MM Port SM Port
The OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A is an OTDR module for single and multimode fiber use. It supports all-inone OTDR, FTTA, and OLTS measurements required for checking optical fiber. Select a model with the dynamic range matching the test requirements. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.
Model MU100021A
J1693A J1694A W3811AE
Name
OTDR Module 1310/1550/850/1300 nm SMF/MMF
Standard Accessories
Universal Connector 2.5 mm for OPM:
1 pc
Universal Connector 1.25 mm for OPM:
1 pc
Quick Reference Guide:
1 pc
2-2-1 Selecting Dynamic Range
The MU100021A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range 1310/1550/850/1300 nm: 42/41/29/28 dB
MU100021A-021
Model
Name Enhanced Dynamic Range
2-2-2 Selecting Polish Type/Connector Adapter
The MU100021A is available in a total of five models (3 UPC and 2 APC) as
listed below. Specify the required connector type at ordering. Two specified
connectors (for SMF and MMF ports) are provided as standard accessories. The
polish type cannot be changed after purchase.
Connector Adapter
Polish Type
UPC*1
Model
UPC Ultra Physical Contact
MM Port
UPC Ultra Physical Contact
SM Port
APC1, 2 (SM port only, MM port is UPC)
Model
UPC Ultra Physical Contact
MM Port
APC Angled Physical Contact
SM Port
FC Connector
MU100021A-010 MU100021A-037
MU100021A-011 MU100021A-025
DIN 47256 Connector
MU100021A-010 MU100021A-039
SC Connector
MU100021A-010 MU100021A-040
MU100021A-011 MU100021A-026
1: Different connector adapter types cannot be specified for the SMF and MMF ports. 2: There is no APC polish type for the MMF port. As a result, this connector adapter polish type is UPC.
2-2-3 Selecting Visible Light Source Option
Breaks in the optical fiber can be detected by eye using this light source. This option cannot be added by retrofit after purchase.
Model MU100021A-002
Name Visual Fault Locator
Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm.
J1335A
MU/LC Connector Adapter Required conversion adapter for inserting LC (1.25 mm) optical fiber
14
New Purchase
OTDR Module
2-3 OTDR Module 1310/1550/1625 nm SMF MU100022A
OPM Port
SM Port
Model
Name
MU100022A
OTDR Module 1310/1550/1625 nm SMF
Standard Accessories
J1693A
Universal Connector 2.5 mm for OPM:
1 pc
The OTDR Module 1310/1550/1625 nm SMF MU100022A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR,
J1694A
Universal Connector 1.25 mm for OPM:
1 pc
FTTA, and OLTS measurements required for checking optical fiber.
W3811AE
Quick Reference Guide:
1 pc
Additionally, combined used with the visible light source options
support visual confirmation of fiber breaks, etc.
2-3-1 Selecting Dynamic Range
The MU100022A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range 1310/1550/1625 nm: 46/46/44 dB
MU100022A-022
Model
Name High-Performance Dynamic Range
2-3-2 Selecting Polish Type/Connector Adapter The MU100022A is available in a
total of five models (3 UPC and 2 APC) as listed below. Specify the required
connector type at ordering. The specified connector is provided as a standard
accessory. The polish type cannot be changed after purchase.
Polish Type
UPC
APC
Connector Adapter
Model
UPC Ultra Physical Contact
Model
APC Angled Physical Contact
FC Connector
MU100022A-010 MU100022A-037
MU100022A-011 MU100022A-025
DIN 47256 Connector
MU100022A-010 MU100022A-039
SC Connector
MU100022A-010 MU100022A-040
MU100022A-011 MU100022A-026
2-3-3 Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.
Model MU100022A-002
Name Visual Fault Locator
Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm
J1335A
MU/LC Connector Adapter
Required conversion adapter for inserting LC (1.25 mm) optical fiber
15
New Purchase
OTDR Module
2-4 OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A
OPM Port
SM Port
SM Port
(1650 nm) (1310/1550 nm)
Model
Name
MU100023A
OTDR Module 1310/1550/1650 nm SMF
Standard Accessories
J1693A
Universal Connector 2.5 mm for OPM:
1 pc
The OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A is an OTDR module for single mode fiber use only. It supports all-in-one
J1694A
Universal Connector 1.25 mm for OPM:
1 pc
OTDR, FTTA, and OLTS measurements required for checking optical
W3811AE
Quick Reference Guide:
1 pc
fiber. Additionally, combined used with the visible light source options
support visual confirmation of fiber breaks, etc.
2-4-1 Selecting Dynamic Range
The MU100023A has a fixed dynamic range; select the following model.
Wavelength: Dynamic Range 1310/1550 nm: 42/41 dB, 1650 nm: 35 dB
MU100023A-021
Model
Name Enhanced Dynamic Range
2-4-2 Selecting Polish Type/Connector Adapter The MU100023A is available in a
total of five models (3 UPC and 2 APC) as listed below. Specify the required
connector type at ordering. The specified connector is provided as a standard
accessory. The polish type cannot be changed after purchase.
Polish Type
UPC*
APC*
Connector Adapter
Model
UPC Ultra Physical Contact
Model
APC Angled Physical Contact
FC Connector
MU100023A-010 MU100023A-037
MU100023A-011 MU100023A-025
DIN 47256 Connector
MU100023A-010 MU100023A-039
SC Connector
MU100023A-010 MU100023A-040
MU100023A-011 MU100023A-026
*: Different types of connector adapters cannot be selected for the SM port (1310/1550 nm) and the SM port (1650 nm).
2-4-3 Selecting Visible Light Source Option
Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.
Model MU100023A-002
Name Visual Fault Locator
Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm.
J1335A
MU/LC Connector Adapter
Required conversion adapter for inserting LC (1.25 mm) optical fiber
16
New Purchase
OTDR Module
2-5 Selecting MU100020A/MU100021A/MU100022A/MU100023A Options The OTDR Module connector is available in a total of five types (3 UPC and 2 APC). These connectors can be changed freely by the user. However, connectors with mismatched polish types cannot be used.
2-5-1 OTDR Module Conversion Connector Adapters
Model Name
J0617B (FC/UPC) Changeable Optical Connector (FC-PC)
UPC (Option 010), SM/MM Ports J0618E (DIN/UPC) Changeable Optical Connector (DIN)
J0619B (SC/UPC) Changeable Optical
Connector (SC)
APC (Option 011), SM Port
J0739A (FC/APC)
J1697A (SC/APC)
Changeable Optical Connector (FC-APC)
Changeable Optical Connector (SC-APC)
Form
2-5-2 Optical Fiber Conversion Adapters
Model
Name
J1530A SC Plug-in Converter (UPC (P)-APC (J))
Notes
SC/UPC SC/APC Conversion
(Physical contact)
10° to 25°
UPC (P)
(Angle physical contact)
APC (J)
8°
J1531A SC Plug-in Converter (APC (P)-UPC (J))
(Angle physical contact)
8°
APC (P)
SC/APC SC/UPC Conversion
UPC (J)
(Physical contact)
10° to 25°
J1532A FC Plug-in Converter (UPC (P)-APC (J))
(Physical contact)
10° to 25°
UPC (P)
FC/UPC FC/APC Conversion
(Angle physical contact)
APC (J)
8°
J1533A FC Plug-in Converter (APC (P)-UPC (J)) J1534A LC-SC Plug-in Converter
(for SM, SC (P)-LC (J)) J1535A LC-SC Plug-in Converter
(for MM, SC (P)-LC (J))
(Angle physical contact)
APC (P)
8°
(Physical contact)
10° to 25°
UPC (P)
(Physical contact)
10° to 25°
UPC (J)
FC/APC FC/UPC Conversion
UPC (J)
(Physical contact)
10° to 25°
SC/UPC LC/UPC Conversion. SM Fiber Only
UPC (J)
(Physical contact)
10° to 25°
SC/UPC LC/UPC Conversion. MM Fiber Only
(Physical contact)
UPC (P)
10° to 25°
2-5-3 Others
Model NETWORKS
W3810AE
Name
Notes
PC Emulation Software for Data Analysis and Reporting
Supports PC running Microsoft Windows 7 and Windows 10 to edit waveform data and create reports
MT1000A MU100020A Network Master Pro Operation Manual MT1000A and MU100020A/MU100021A/MU100022A/MU100023A operation manuals
17
New Purchase
Common Application Parts, Extended Warranty Services and Remote Software
Service
3-1 MT1040A Power Supply Option Depending on module combination, it is necessary to order MT1040A-020 Activate for 400G Dual/100G Quad Option.
Without MT1040A-020 (Battery Operational)
With MT1040A-020
2U
3U
400G (QSFP-DD) Multirate Module MU104014A 400G (OSFP) Multirate Module
MU104015A 100G Multirate Module MU104011A
10G Multirate Module MU100010A 100G Multirate Module MU100011A
1310/1550 nm SMF MU100020A 1310/1550/850/1300 nm SMF/MMF MU100021A
1310/1550/1625 nm SMF MU100022A 1310/1550/1650 nm SMF MU100023A
4U
5U
3-2 MT1040A Selecting Common Application Parts Various application parts make
the MT1040A more convenient to use.
Battery Charger G0324A This is the charger for the MT1040A G0413A Li-ion
battery.
Video Inspection Probe G0382A/G0306B Scratches and dirt on the connector end
face are a major cause of degraded communications quality. The MT1040A has a
built-in VIP function for analyzing the condition of the optical connector end
face in the utility menu. When the VIP is connected, scratches and dirt on the
optical connector end face are visualized (× 400) and the OK/NG status is
evaluated based on the IEC61300-3-35 standard. Anritsu supports VIP Series
G0382A (USB Autofocus Type) and G0306B (USB Standard Type).
G0382A
G0306B
Different tip types are used by the G0382A and G0306B.
Optical Connector End-face Inspection/Evaluation Screen
18
New Purchase
Common Application Parts, Extended Warranty Services and Remote Software
Service
Accessories for MT1040A Dual-Module Configuration The size of the MT1040A depends on the module configuration. Choose the appropriate case.
Module Combination
Short (2U) Standard Transport (Type 2) (3U)
Mounting Skrews
B0730A
B0745A
Soft Case
B0772A
B0733A
Hard Case
B0773A
B0731A
+ Transport (Type 1) or OTDR Module (4U)
B0740A
Two Transport (type 2) Modules (5U) B0741A
345 (W) × 238 (H) × 480 (D) mm, 3.5 kg
495 (W) × 338 (H) × 663 (D) mm, 12.3 kg
MT1040A
B0733A Size of Each Hard Case for MT1040A
B0773A
Optical Cables Model
J1571A J1575A J1579A J1581A
Name Optical cable SM LC/PC to SC/PC 3 m Optical Cable SM LC/PC to FC/PC 3 m Optical Cable SM LC/PC to LC/PC 3 m Optical Cable MM LC/PC to LC/PC 3 m
MT1040A Module Connection Parts
Model
B0720A
Rear Panel
B0730A
Screw 2U
B0731A
Screw 3U
B0740A
Screw 4U
B0741A
Screw 5U
B0769A
MT1040A Screw Kit
Name
Single core (no paired cables) Single core (no paired cables) Single core (no paired cables) Single core (no paired cables)
Notes
Notes MT1040A Rear Panel 2 units screw set (Total 4 pcs) 3 units screw set (Total 4 pcs) 4 units screw set (Total 4 pcs) 5 units screw set (Total 4 pcs) Composed of B0730A, B0731A, B0740A and B0741A.
19
New Purchase
Common Application Parts, Extended Warranty Services and Remote Software
Service
3-3 MT1040A Selecting Extended Warranty Services The standard warranty period is 1 year. An extended warranty can be purchased for the main frame and the test interface modules as listed below.
Model
Name
MT1040A
MT1040A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MT1040A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MT1040A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU104014A
MU104014A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU104014A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU104014A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU104015A
MU104015A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU104015A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU104015A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU104011A
MU104011A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU104011A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU104011A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100010A
MU100010A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100010A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100010A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
Model
Name
MU100011A
MU100011A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100011A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100011A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100020A
MU100020A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100020A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100020A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100021A
MU100021A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100021A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100021A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100022A
MU100022A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100022A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100022A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
MU100023A
MU100023A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)
MU100023A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)
MU100023A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)
20
New Purchase
Common Application Parts, Extended Warranty Services and Remote Software
Service
3-4 Remote Software Service The following licenses must be purchased to use the MX109020A Site Over Remote Access.
Mainframe Option License
Model/Order No. MT1040A-0031 MT1040A-0112
Name WLAN/Bluetooth Connect Site Over Remote Access Connect
1: WLAN is available for certified countries and regions including USA, Canada, Japan and EU countries. Please visit the Anritsu web site for updated information.
Although this product has not been approved by Bluetooth SIG, the supported
frequencies are in the range assigned to Bluetooth® communications.
2: Validity period is unlimited. An open TCP port may be required to allow the MT1040A to be connected from an in-company LAN to MX109020A, depending on the
LAN security policy.
Subscription Option License
Model/Order No. MX109020A3, 5, 6, 7 MX109020A-TL0013, 4 MX109020A-0015 MX109020A-0025 MX109020A-003*8
Name Site Over Remote Access Basic License Site Over Remote Access 1 Year License Site Over Remote Access 8 Units Site Over Remote Access Unlimited Units Centralized Data Management
3: We recommend purchasing a 1-year license in addition to the basic license. 4: When extending the usage period, we recommend purchasing in 1-year license periods 5: Up to two measuring instruments can be remotely controlled simultaneously with the basic license.
This number can be increased to up to 8 units by purchasing the MX109020A-001
option, and up to 100 units by purchasing the MX109020A-002 option.
6: You must agree to the service terms before purchasing SORA.
Refer to the service terms at the following URL: https: //www.anritsu.com/en-
AU/test-measurement/support/downloads/manuals/dwl20059
7: This product cannot be used in some regions and countries; please read the service terms for more details. 8: Users must provide their own storage at the upload destination.
21
Additional Purchases Flowchart
Use this flowchart when adding modules and options to a previously purchased MT1040A.
Adding Functions Adding Protocol Options
Adding Transport Module
Confirm the serial numbers of the MU100010A/MU100011A/ MU104011A/MU104014A/
MU104015A.
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 4-1 Adding Test Protocols for Transport Module.
Page 24 to 28
Select Optical I/F Select the model for choosing the optical module frequency
and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.
Page 11
Select the type of interface to measure (10G) Up to 10G including PDH with
independent dual port. (100G Single) 100G, 40G and 25G with single port. Up to
10G are with two ports which are restricted to be same protocol (Ethernet,
OTN, FC,
SDH/SONET) (100G Dual) Up to 100G with independent dual port. (200G/400G)
200G/400G single port.
10G
100G Single
100G Dual
200G/400G
Choose MU100010A Page 9
Choose MU100011A Page 10
Choose MU104011A Page 8
Choose MU104014A for QSFP-DD, 400G/200G, 100G dual
Page 6
Choose MU104015A for OSFP, 400G, 100G single
Page 7
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-4-1 Selecting Protocol Options.
Page 9
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-5-1 Selecting Protocol Options.
Page 10
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-3-1 Selecting Protocol Options.
Page 8
Select Protocol Select the model for choosing the measurement protocol port
number, options, etc., from 1-1-1 (MU104014A) or 1-2-1 (MU104015A) Selecting
Protocol Options.
Page 6, 7
Refer to 3-1 MT1040A Power Supply Option to see your new configuration requires MTT1040A-020 or not.
MT1040A-020 is not necessary
MT1040A-020 is necessary
Check your MT1040A has MT1040A-006 or not
Yes
No
Please contact sales representative
Select Optical I/F Select the model for choosing the optical module frequency and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.
Page 11
Select Transport Test Options Select the model for choosing the required options from 1-7 Selecting Transport Test Option.
Page 12
Selecting Main Frame Accessories. Select the main frame optional accessories
from 3-1 MT1040A Selecting Common Application Parts. Select the model for the
extended hardware warranty from 3-3 MT1040A Selecting Extended Warranty
Services.
Page 18
Record the purchased model and name in the configuration confirmation order sheet.
Page 30
22
Adding OTDR Module
Select Optical Fiber Select the type of optical fiber to measure Single Mode only Both Single Mode and Multimode
Single Mode only
2 Wavelength (1310/1550 nm)
Choose MU100020A Page 13
Wavelength select
3 Wavelength (1310/1550/ 1625 nm)
Choose MU100022A
Page 15
Both Single Mode and Multimode
3 Wavelength (1310/1550/ 1650 nm)
Choose MU100023A
Page 16
Choose MU100021A Page 14
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-1-1 Selecting Dynamic Range.
Page 13
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-3-1 Selecting Dynamic Range.
Page 15
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-4-1 Selecting Dynamic Range.
Page 16
Select Dynamic Range Select the model with the required test wavelength and
dynamic range from 2-2-1 Selecting Dynamic Range.
Page 14
Select Connector Select the model with the required connector type from 2-1-2
Selecting Polish Type/ Connector Adapter.
Page 13
Select Connector Select the model with the required connector type from 2-3-2
Selecting Polish Type/ Connector Adapter.
Page 15
Select Connector Select the model with the required connector type from 2-4-2
Selecting Polish Type/ Connector Adapter.
Page 16
Select Connector Select the model with the required connector type from 2-2-2
Selecting Polish Type/ Connector Adapter.
Page 14
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-1-3 Selecting Visible Light Source Option.
Page 13
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-3-3 Selecting Visible Light Source Option.
Page 15
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-4-3 Selecting Visible Light Source Option.
Page 16
With/Without Visible Light Source Select the model with built-in visible light
source if required from 2-2-3 Selecting Visible Light Source Option.
Page 14
Selecting OTDR Test Options Select the models with the option choices from
2-5-1 OTDR Module Conversion Connector Adapters, 2-5-2 Optical Fiber
Conversion Adapters, and 2-5-3 Others.
Page 17
23
Additional Purchases
Adding New Options to Previously Purchased MT1040A
Confirm the serial numbers of the MT1040A, MU104014A/MU104015A/MU104011A and
MU100010A/MU100011A.
4-1 Adding Test Protocols for Transport Module When adding options, please either specify one of the following media along with the relevant option, or Web download.
Model Z1849A Z1850A
Name DVD-ROM for Retrofit Options USB Stick for Retrofit Options
In addition, when purchasing multiple retrofit options at one time, they are all installed using the same media.
MU104014A Transport Technology Ethernet
Bit Rate
No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
Pass-through (10G), Channel Stat (10G) TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-XDR4 N-Port BERT eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring
using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
SDH/SONET
Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test,
Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan
10G or less 2 (Dual Channel)
16G or 25G
40G or 100G
2 (Dual Channel) 1 (Single Channel) 2 (Dual Channel)
MU104014A-312 Ethernet up to 25G Dual Channel Retrofit
MU104014A-312
Ethernet up to 25G
—
Dual Channel Retrofit
MU104014A-320
TCP Throughput
—
Retrofit*2
MU104014A-313 MU104014A-314
Ethernet 40G
Ethernet 40G
Single Channel Retrofit Dual Channel Retrofit
MU104014A-315 MU104014A-316
Ethernet 100G
Ethernet 100G
Single Channel Retrofit Dual Channel Retrofit
—
—
—
—
—
—
—
—
MU104014A-312 Ethernet up to 25G Dual Channel Retrofit
MU104014A-313 MU104014A-314
Ethernet 40G
Ethernet 40G
Single Channel Retrofit Dual Channel Retrofit
MU104014A-315 MU104014A-316
Ethernet 100G
Ethernet 100G
Single Channel Retrofit Dual Channel Retrofit
MU104014A-352 OTN up to 10G
Dual Channel Retrofit
MU104014A-363 ODU Multiplexing/ Multi Stage Retrofit*3
MU104014A-353 MU104014A-354
—
OTN 40G
OTN 40G
Single Channel Retrofit Dual Channel Retrofit
MU104014A-355 MU104014A-356
—
OTN 100G
OTN 100G
Single Channel Retrofit Dual Channel Retrofit
—
MU104014A-363
ODU Multiplexing/Multi Stage Retrofit*3
MU104014A-374
—
—
CPRI/OBSAI up to 25G Dual Channel Retrofit
MU104014A-392 FC up to 16G Dual Channel Retrofit
MU104014A-382
SDH/SONET up to
—
10G Dual Channel
Retrofit
—
—
MU104014A-384*4 STM-256/OC-768 Client Signal Retrofit
200G or 400G 1 (Single Channel) MU104014A-331
Ethernet 200G Single Channel Retrofit MU104014A-333
Ethernet 400G Single Channel Retrofit
—
— MT104014A-334 4×100G N Port BERT
Retrofit
—
—
—
—
—
—
—
—
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104014A-012. 3: Requires that at least one of the following option is installed: MU104014A-052, MU104014A-053, MU104014A-054, MU104014A-055, MU104014A-056. 4: MU104014A does not have a physical interface of the option. The option is required for client signal mapped in the OTN. 24
Additional Purchases
Adding New Options to Previously Purchased MT1040A
MU104015A Transport Technology Ethernet
Bit Rate No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
Pass-through (10G), Channel Stat (10G) TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-2FR4 N-Port BERT eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring
using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event
Generation, Tributary Scan
10G or less 2 (Dual Channel)
16G or 25G 2 (Dual Channel)
MU104015A-312 Ethernet up to 25G Dual Channel Retrofit
MU104015A-312
Ethernet up to 25G
—
Dual Channel Retrofit
MU104015A-320
TCP Throughput
—
Retrofit*2
—
—
MU104015A-312 Ethernet up to 25G Dual Channel Retrofit
— MU104015A-352
OTN up to 10G
Dual Channel Retrofit
—
MU104015A-363
ODU Multiplexing/
—
Multi Stage Retrofit*3
MU104015A-374 CPRI/OBSAI up to 25G Dual Channel Retrofit
MU104015A-392 FC up to 16G Dual Channel Retrofit
MU104015A-382
SDH/SONET up to
—
10G Dual Channel
Retrofit
40G or 100G 1 (Single Channel) 2 (Dual Channel)
MU104015A-313
Ethernet 40G
—
Single Channel Retrofit
MU104015A-315
Ethernet 100G
—
Single Channel Retrofit
—
—
—
—
—
—
MU104015A-313
Ethernet 40G
—
Single Channel Retrofit
MU104015A-315
Ethernet 100G
—
Single Channel Retrofit
MU104015A-353
OTN 40G
—
Single Channel Retrofit
MU104015A-355
OTN 100G
—
Single Channel Retrofit
MU104015A-363
ODU Multiplexing/
—
Multi Stage Retrofit*3
—
—
—
—
MU104015A-384*4 STM-256/OC-768 Client Signal Retrofit
400G 1 (Single Channel)
— MU104015A-333
Ethernet 400G Single Channel Retrofit
— — MU104015A-335 2×200G N Port BERT Retrofit
— —
— — —
—
—
—
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104015A-012. 3: Requires that at least one of the following option is installed: MU104015A-052, MU104015A-053, MU104015A-055. 4: MU104015A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
25
Additional Purchases
Adding New Options to Previously Purchased MT1040A
MU104011A Transport Technology Ethernet
Bit Rate No. of Measurement Ports*1
10G or less 2 (Dual Channel)
16G or 25G 2 (Dual Channel)
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector
MU104011A-312 Ethernet up to 25G Dual Channel Retrofit
Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) eCPRI/RoE (IEEE1914.3)
MU104011A-312
Ethernet up to 25G
—
Dual Channel Retrofit
MU104011A-320
—
TCP Throughput Retrofit*2
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
MU104011A-312 Ethernet up to 25G Dual Channel Retrofit
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test,
MU104011A-352
—
O.182 Test, Overhead Editing/Capture, TCM Monitoring/
OTN up to 10G
Generation, Tributary Scan
Dual Channel Retrofit
—
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring
using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event
Generation, Tributary Scan
MU104011A-363
ODU Multiplexing/
—
Multi Stage Retrofit*3
MU104011A-374 CPRI/OBSAI up to 25G Dual Channel Retrofit
MU104011A-392 FC up to 16G Dual Channel Retrofit
MU104011A-382
SDH/SONET up to 10G
—
Dual Channel Retrofit
40G or 100G
1 (Single Channel)
2 (Dual Channel)
MU104011A-313 Ethernet 40G
Single Channel Retrofit MU104011A-315 Ethernet 100G
Single Channel Retrofit
—
MU104011A-314 Ethernet 40G
Dual Channel Retrofit MU104011A-316
Ethernet 100G Dual Channel Retrofit
—
—
—
MU104011A-313 Ethernet 40G
Single Channel Retrofit
MU104011A-315 Ethernet 100G
Single Channel Retrofit
MU104011A-314 Ethernet 40G
Dual Channel Retrofit
MU104011A-316 Ethernet 100G
Dual Channel Retrofit
MU104011A-353 OTN 40G
Single Channel Retrofit
MU104011A-355 OTN 100G
Single Channel Retrofit
MU104011A-354 OTN 40G
Dual Channel Retrofit
MU104011A-356 OTN 100G
Dual Channel Retrofit
MU104011A-363 ODU Multiplexing/Multi Stag Retrofite*3
—
—
—
—
MU104011A-384*4 STM-256/OC-768 Client Signal Retrofit
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: Requires to MU104011A-012. 3: Requires that at least one of the following option is installed: MU104011A-052, MU104011A-053, MU104011A-054, MU104011A-055, MU104011A-056. 4: MU104011A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
26
Additional Purchases
Adding New Options to Previously Purchased MT1040A
Adding MU100010A Protocol Option
Bit Rate
Transport Technology
No. of Measurement Ports*1
Ethernet
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through, Channel Stat
TCP Throughput Test (RFC 6349, iPerf)
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
OTN2,
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition3 ODU Flex Addition*4 CPRI/OBSAI CPRI/OBSAI L1:
Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre
Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error
Monitoring
SDH/SONET, PDH/DSn PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event
Generation, Tributary Scan
Less than 5G 2 (Dual Channel)
From 6G to 10G
1 (Single Channel)
2 (Dual Channel)
MU100010A-301
Up to 2.7G Dual Channel Retrofit
MU100010A-311
Ethernet 10G Single Channel Retrofit
MU100010A-312
Ethernet 10G Dual Channel Retrofit
MU100010A-320 TCP Throughput Retrofit
MU100010A-301
Up to 2.7G Dual Channel Retrofit
MU100010A-311
Ethernet 10G Single Channel Retrofit
MU100010A-312
Ethernet 10G Dual Channel Retrofit
MU100010A-301
Up to 2.7G Dual Channel Retrofit
MU100010A-351
OTN 10G Single Channel Retrofit
MU100010A-352
OTN 10G Dual Channel Retrofit
MU100010A-361 ODU Multiplexing Retrofit
—
MU100010A-362 ODU Flex Retrofit
MU100010A-371
CPRI/OBSAI Up to 5G Dual Channel Retrofit
MU100010A-372
CPRI/OBSAI 6G to 10G Single Channel Retrofit
MU100010A-373
CPRI/OBSAI 6G to 10G Dual Channel Retrofit
MU100010A-302
FC 1G 2G 4G Dual Channel Retrofit
MU100010A-391
FC 8G 10G Single Channel Retrofit
MU100010A-301
Up to 2.7G Dual Channel Retrofit
MU100010A-381
STM-64 OC-192 Single Channel Retrofit
MU100010A-392 FC 8G 10G Dual Channel
Retrofit
MU100010A-382 STM-64 OC-192
Dual Channel Retrofit
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate
simultaneously, or two different single channel options can operate
simultaneously.
2: When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the
MU100010A-351/352 (for physical port) and the MU100010A-381/382 (for client
signal) are required.
3: When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel.
4: When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.
27
Additional Purchases
Adding New Options to Previously Purchased MT1040A
Adding MU100011A Protocol Option Transport Technology Ethernet
Bit Rate
No. of Measurement Ports*1
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery
Pass-through, Channel Stat TCP Throughput Test (RFC 6349, iPerf) SyncE Wander
Measurement using 100GBASE-SR
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
Measurement using 100GBASE-SR
OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition2, 4 ODU Flex Addition2, 5 CPRI/OBSAI CPRI/OBSAI
L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring,
Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre
Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error
Monitoring
SDH/SONET PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error
Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event
Generation, Tributary Scan
Up to 10G 1 (Single Channel) 2 (Dual Channel)
Higher than 10G
1 (Single Channel)
2 (Dual Channel)
MU100011A-317*8
Ethernet 25G
—
Single Channel Retrofit
MU100011A-301 MU100011A-303
MU100011A-313*9 Ethernet 40G
—
Up to 10G
Up to 10G
Single Channel Retrofit
Single Channel Retrofit Dual Channel Retrofit
MU100011A-315*9
Ethernet 100G
—
Single Channel Retrofit
—
—
MU100011A-320 TCP Throughput
—
—
MU100011A-021*10 SyncE Wander
—
MU100011A-323*8
RS-FEC for 100GBASE-SR4
—
—
Retrofit MU100011A-315*9
—
Ethernet 100G
Single Channel Retrofit
MU100011A-301 Up to 10G
Single Channel Retrofit
—
MU100011A-303 Up to 10G
Dual Channel Retrofit
—
MU100011A-3178 Ethernet 25G
Single Channel Retrofit
MU100011A-3139 Ethernet 40G
Single Channel Retrofit
MU100011A-3159 Ethernet 100G
Single Channel Retrofit
MU100011A-3238 RS-FEC for 100GBASE-SR4
Retrofit
MU100011A-315*9 Ethernet 100G
Single Channel Retrofit
MU100011A-3757, 8 eCPRI/RoE 25G Dual Channel Retrofit — —
—
MU100011A-353
MU100011A-301
MU100011A-303
OTN 40G Single Channel Retrofit
—
Up to 10G
Up to 10G
Single Channel Retrofit Dual Channel Retrofit
MU100011A-355 OTN 100G
—
Single Channel Retrofit
MU100011A-363 ODU Multiplexing/Multi Stage Retrofit
MU100011A-362 ODU Flex Retrofit
—
MU100011A-371 MU100011A-372 CPRI/OBSAI Up to 10G CPRI/OBSAI Up to 10G Single Channel Retrofit Dual Channel Retrofit
MU100011A-373 CPRI 12/25G
Single Channel Retrofit
MU100011A-374 CPRI 12/25G
Dual Channel Retrofit
MU100011A-304 MU100011A-305
MU100011A-391
Up to 10G FC
Up to 10G FC
FC 16G
—
Single Channel Retrofit Dual Channel Retrofit Single Channel Retrofit
MU100011A-301 MU100011A-303
MU100011A-383*6
Up to 10G
Up to 10G
STM-256/OC-768
—
Single Channel Retrofit Dual Channel Retrofit
Client Signal Retrofit
*1:
The channel is not related to the physical port For a dual channel setup, the two different ports
position. The user can freely choose either of the two can operate simultaneously with different bit rate of the
physical ports assigned same single protocol.
to
the
option
via
software.
**23::
Please see the datasheet for supported OTN mapping. When using the OTN function, the channel can be used For example, when mapping STM-256/OC-768 to OTU4,
as client signal mapped to both the MU100011A-355
OTN. (for physical
port)
and
the
MU100011A-383
(for
client
signal)
are
required.
*4:
When the ODU Multiplexing/Multistage option is This one option supports both single channel and
installed, OTN dual channel.
multistage
mapping
measurements
are
supported.
**567891:::::0TTOFF: EEhh4pCC0iestGiciMomsanaUananlsp1wdbup0eap10iynp0s0sgwo01OrG1ifttuAFscanFherhc.eeCtadiPsonROonnItoN/isRs/SuobOTpEaFMpsFpeo-.rd2rot5teo6odn/c .OothlCet-e7Os6tD8s UoPFnHlleYyx.insttaenrfdaacred;
for transmissions it can be used for
over OTN
OTN networks client signals.
and
supports
client
signals
of
any
speed.
28
Additional Purchases
Adding New Options to Previously Purchased MT1040A
4-2 Adding Main Frame Options for Transport Function
The MT1040A serial number is required at purchase.
Model MT1040A-303 MT1040A-320
MT1040-311
Name Connectivity for WLAN/Bluetooth Retrofit Activate for 400G Dual/100G Quad
retrofit
Site Over Remote Access Connect retrofit
Notes
WLAN/Bluetooth options (can be used in approved countries, including N.
America, Japan, EU; see Anritsu web site for latest list of countries)
In mounting two transport modules, this option is required. This option
includes AC Adapter G0419A. Please refer to 3.1 Power supply option.
– When the MT1040A already has MT1040A-006, please order MT1040A-320. – When
the MT1040A does not have MT1040A-006, please contact to sales representative.
This option enables remote control of the MT1040A using the Site Over Remote
Access MX109020A software. We recommend using in conjunction with the
WLAN/Bluetooth option MT1040A-003/303. A Wi-Fi dongle can be used in countries
and regions where WLAN is not supported. For a list of supported Wi-Fi
dongles, please contact us.
When adding MT1040A-303 and/or MT1040A-311, please either specify one of the following media along with the relevant option, or Web download.
Model Z1849A Z1850A
Name DVD-ROM for Retrofit Options USB Stick for Retrofit Options
4-3 Adding Transport Module
When adding Transport Module to a previously purchased MT1040A, use the same
procedure as for Transport Module described on pages 6 thru 12, 18 thru 21.
4-4 Adding OTDR Module When adding the OTDR Module to a previously purchased MT1040A, use the same procedure as for OTDR Module described on pages 13 thru 21.
4-5 Adding MX109020A Option Requires MX109020A serial number at purchase.
Model MX109020A-TL001 MX109020A-301 MX109020A-302 MX109020A-303
Name Site Over Remote Access 1 Year License Site Over Remote Access 8 Units Site Over Remote Access Unlimited Units Centralized Data Management
Notes Extends MX109020A usage period by 1 year Extends number of instruments simultaneously controlled by MX109020A to 8 units Extends number of instruments simultaneously controlled by MX109020A to 100 units Supports upload of measurement report from MT1040A to cloud storage
29
Network Master Pro MT1040A
Configuration Examples
400G Core/Metro Installation The most simple configuration to install 400G network.
Model
Name
Q’ty
MT1040A
Network Master Pro
1
MU104014A
400G (QSFP-DD) Multirate Module
1
MU104014A-033 Ethernet 400G Single Channel
1
G0404A
QSFP-DD 400GBASE-LR4
1
Up to 400G Ethernet Installation and Maintenance
Multirate Ethernet configuration to install or maintein Carrier class Ethernet
network.
Model
Name
Q’ty
MT1040A
Network Master Pro
1
MU104014A
400G (QSFP-DD) Multirate Module
1
MU104014A-012 Ethernet up to 25G Dual Channel
1
MU104014A-014 Ethernet 40G Dual Channel
1
MU104014A-016 Ethernet 100G Dual Channel
1
MU104014A-031 Ethernet 200G Single Channel
1
MU104014A-033 Ethernet 400G Single Channel
1
G0322A
1G/2G/4G FC 1310 nm SFP
2
G0315A
10G LR/LW 1310 nm SFP+
2
G0389A
25G LR 1310nm SFP28
2
G0334A
40G LR4 1310 nm QSFP+
2
G0364A
100G LR4 1310 nm QSFP28
2
G0421A
QSFP56 200GBASE-LR4
1
G0404A
QSFP-DD 400GBASE-LR4
1
400G Ethernet Dual Port for System Verification
The detail verification of 400G Ethernet system such as bi-directional
testing.
Model
Name
Q’ty
MT1040A
Network Master Pro
1
MT1040A-020
Activate for 400G Dual/100G Quad Option
1
MU104014A
400G (QSFP-DD) Multirate Module
2
MU104014A-033 Ethernet 400G Single Channel
2
G0404A
QSFP-DD 400GBASE-LR4
2
Up to 400G Datacom Network Installation and Maintenance
Multirate and multiprotocol configuration to install or maintein datacom
network.
Model
Name
Q’ty
MT1040A
Network Master Pro
1
MU104014A
400G (QSFP-DD) Multirate Module
1
MU104014A-012 Ethernet up to 25G Dual Channel
1
MU104014A-014 Ethernet 40G Dual Channel
1
MU104014A-016 Ethernet 100G Dual Channel
1
MU104014A-031 Ethernet 200G Single Channel
1
MU104014A-033 Ethernet 400G Single Channel
1
MU104014A-020 TCP Throughput
1
MU104014A-092 FC up to 16G Dual Channel
1
G0322A
1G/2G/4G FC 1310 nm SFP
2
G0315A
10G LR/LW 1310 nm SFP+
2
G0364A
100G LR4 1310 nm QSFP28
2
G0421A
QSFP56 200GBASE-LR4
1
G0404A
QSFP-DD 400GBASE-LR4
1
Ethernet Service and Optical Fiber Commissioning Transport and OTDR in one box with upgradability to 400G.
Model
Name
Q’ty
MT1040A
Network Master Pro
1
MU104014A
400G (QSFP-DD) Multirate Module
1
MU104014A-012 Ethernet up to 25G Dual Channel
1
MU104014A-016 Ethernet 100G Dual Channel
1
MU100022A
OTDR Module 1310/1550/1625 nm SMF
1
MU100022A-022 High-Performance Dynamic Range
1
MU100022A-010 UPC Polish
1
MU100022A-037 FC Connector
1
MU100022A-002 Visual Fault Locator
1
G0322A
1G/2G/4G FC 1310 nm SFP
2
G0315A
10G LR/LW 1310 nm SFP+
2
G0364A
100G LR4 1310 nm QSFP28
2
30
Network Master Pro MT1040A
Order Sheet
When recording different MT1040A configurations on one order sheet, describe each MT1040A configuration on one line with the accompanying options under the relevant line.
Model
Name
Quantity
31
Network Master Pro MT1040A
Method for Adding Measurement Modules
Preparation 1: Version up the software for MT1040A Install the latest software
in the MT1040A. This software can be obtained from the Anritsu web site.
Preparation 2: Remove the battery pack from Mainframe 1) Disconnect the AC
cable. 2) Use screw driver or Coin and remove the battery lid from MT1040A.
Attaching the Transport (MU10001xA) or OTDR (MU10002xA) Module 1) Remove four
screws of former module and replace to the next screws.
Choose the bolts matching the added module. Use the B0740A for transport
(MU10001xA) or OTDR module.
For Adding MU10401xA Module (B0741A)
For Adding MU10001xA, MU10002xA (B0740A)
Standard Part (B0731A)
-
Remove the battery pack.
-
Align the OTDR module horizontally with the MT1040A as shown below. Align the connectors on the left side.
Preparation 3: Replacing the connected modules 1) Place the instrument on its
front on a plain surface.
Loosen the screws (shown by the blue circle) on rear side of the connected
module.
2) After loosing the four screws, lift up the connected module with holding
both sides. If you cannot lift up, loosen the four screws again. You can see
the panel as below.
MT1040A Main Unit Side
Measurement Modules Side
- Install the OTDR module in the correct MT1040A slot as shown below.
OTDR Module MU10002xA
Transport Module MU10401xA
MT1040A Mainframe
Side View after Assembling Modules Note: Align the four edges when installing
the option; the module connector is
easily damaged by misalignment. 4) Secure the module using the B0740A part
chosen in step 1.
After installing the module as shown in the figure on the right, check that
there is no gap between the modules.
MT1040A Main Unit Back Panel
32
After attaching the modules 1) After attaching the modules,
connect the AC cable or install the battery packs.
2) Turn on the MT1040A. Please check whether a new module is recognized at the
system information.
Network Master Pro MT1040A
Method for Adding Measurement Modules
Adding Transport Module (MU10401xA) 1) Confirm that the MT1040A-020 option is
installed in the MT1040A
main unit. 2) Choose the bolts matching the added module.
Use the B0741A for the MU10401xA module
For Adding MU10401xA Module (B0741A)
For Adding MU10001xA, MU10002xA (B0740A)
Standard Part (B0731A)
After attaching the modules
-
Connect the G0419A standard accessory of the MT1040A-020 option to the MT1040A. The G0418A will not start. Additionally, battery operation is not possible when two transport modules are installed.
-
Turn on the MT1040A. Please check whether a new module is recognized at the system information.
-
Align the transport module horizontally with the MT1040A as shown below.
Align the connectors on the left side.
MT1040A Main Unit Side
Measurement Modules Side
- Install the transport module in the correct MT1040A slot as shown below.
400G (QSFP-DD) Module MU104014A
400G (QSFP-DD) Module MU104014A
MT1040A Mainframe
Side View after Assembling Modules
Note: Align the four edges when installing the option; the module connector is
easily damaged by misalignment.
5) Secure the module using the B0741A part chosen in step 2. After installing
the module as shown in the figure on the right, check that there is no gap
between the modules.
33
Note
34
Note
35
Specifications are subject to change without notice.
· United States Anritsu Americas Sales Company
450 Century Parkway, Suite 190, Allen, TX 75013 U.S.A. Phone: +1-800-Anritsu
(1-800-267-4878)
· Canada Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone:
+1-613-591-2003 Fax:
+1-613-591-1006
· Brazil Anritsu Eletronica Ltda.
Praça Amadeu Amaral, 27 – 1 Andar 01327-010 – Bela Vista – Sao Paulo – SP,
Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940
· Mexico Anritsu Company, S.A. de C.V.
Blvd Miguel de Cervantes Saavedra #169 Piso 1, Col. Granada Mexico, Ciudad de
Mexico, 11520, MEXICO Phone: +52-55-4169-7104
· United Kingdom Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone:
+44-1582-433200 Fax: +44-1582-731303
· France Anritsu S.A.
12 avenue du Québec, Immeuble Goyave, 91140 VILLEBON SUR YVETTE, France Phone:
+33-1-60-92-15-50
· Germany Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1, 81829 München, Germany Phone:
+49-89-442308-0 Fax: +49-89-442308-55
· Italy Anritsu S.r.l.
Spaces Eur Arte, Viale dell’Arte 25, 00144 Roma, Italy Phone: +39-6-509-9711
· Sweden Anritsu AB
Kistagången 20 B, 2 tr, 164 40 Kista, Sweden Phone: +46-8-534-707-00
· Finland Anritsu AB
Technopolis Aviapolis, Teknobulevardi 3-5 (D208.5.), FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
· Denmark Anritsu A/S
c/o Regus Winghouse, Ørestads Boulevard 73, 4th floor, 2300 Copenhagen S,
Denmark Phone: +45-7211-2200
· Russia Anritsu EMEA Ltd. Representation Office in Russia
Tverskaya str. 16/2, bld. 1, 7th floor., Moscow, 125009, Russia Phone:
+7-495-363-1694 Fax:
+7-495-935-8962
· Spain Anritsu EMEA Ltd. Representation Office in Spain
Paseo de la Castellana, 141. Planta 5, Edificio Cuzco IV 28046, Madrid, Spain
Phone: +34-91-572-6761
· Austria Anritsu EMEA GmbH
Am Belvedere 10, A-1100 Vienna, Austria Phone: +43-(0)1-717-28-710
· United Arab Emirates Anritsu EMEA Ltd. Anritsu A/S
Office No. 164, Building 17, Dubai Internet City P. O. Box 501901, Dubai,
United Arab Emirates Phone: +971-4-3758479
· India Anritsu India Private Limited
6th Floor, Indiqube ETA, No.38/4, Adjacent to EMC2, Doddanekundi, Outer Ring
Road, Bengaluru 560048, India Phone: +91-80-6728-1300 Fax: +91-80-6728-1301
· Singapore Anritsu Pte. Ltd.
11 Chang Charn Road, #04-01, Shriro House, Singapore 159640
Phone: +65-6282-2400 Fax: +65-6282-2533
· Vietnam Anritsu Company Limited
16th Floor, Peakview Tower, 36 Hoang Cau Street, O Cho Dua Ward, Dong Da
District, Hanoi, Vietnam
Phone: +84-24-3201-2730
· P.R. China (Shanghai) Anritsu (China) Co., Ltd.
Room 2701-2705, Tower A, New Caohejing International Business Center No. 391
Gui Ping Road Shanghai, 200233, P.R. China
Phone: +86-21-6237-0898 Fax: +86-21-6237-0899
· P.R. China (Hong Kong) Anritsu Company Ltd.
Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza, No. 1 Science Museum
Road, Tsim Sha Tsui East, Kowloon, Hong Kong, P.R. China
Phone: +852-2301-4980 Fax: +852-2301-3545
· Japan Anritsu Corporation
8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan
Phone: +81-46-296-6509 Fax: +81-46-225-8352
· Korea Anritsu Corporation, Ltd.
5FL, 235 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13494 Korea
Phone: +82-31-696-7750 Fax: +82-31-696-7751
· Australia Anritsu Pty. Ltd.
Unit 20, 21-35 Ricketts Road, Mount Waverley, Victoria 3149, Australia
Phone: +61-3-9558-8177 Fax: +61-3-9558-8255
· Taiwan Anritsu Company Inc.
7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816 Fax: +886-2-8751-1817
2106
Printed in Japan 07/FEB/2022 ddcm/CDT Catalog No. MT1040A_ConfigGuide-E-A-1-(2.00)