Annritsu MU104014A Network Master Pro User Guide

October 31, 2023
Annritsu

MU104014A Network Master Pro

Product Information

The Network Master Pro MT1040A is a multiplatform device
designed for field testing. It consists of a main frame and various
measurement modules that can be configured to match the user’s
testing requirements. The main frame controls the test modules,
which can be changed freely to create a custom configuration.

The MT1040A features a 9-inch active TFT display with a touch
screen interface. It also includes a power switch for easy
operation.

The product comes with standard accessories, including a high
power supply, line cord, soft case, rear panel kit, AC adaptor,
Li-ion battery, quick reference guide, stylus, utilities ROM, and
handle.

Additional software options are available for the MT1040A,
including connectivity for WLAN/Bluetooth and site over remote
access connect.

The product supports module configurations for different
transport and optical measurements. These include 400G (QSFP-DD)
multirate module, 400G (OSFP) multirate module, 100G multirate
module, 10G multirate module, and OTDR module.

Product Usage Instructions

  1. Connect the mainframe to a power source using the provided AC
    adapter.

  2. Attach the desired measurement modules to the mainframe by
    inserting them into the appropriate slots.

  3. If using the OTDR module, connect the necessary fiber optic
    cables to the module.

  4. Turn on the power switch located on the mainframe.

  5. Use the touch screen interface to navigate through the
    different measurement options and select the desired test
    parameters.

  6. Follow the on-screen instructions to perform the desired tests
    and measurements.

  7. If using any optional software features, access them through
    the menu and configure them according to your needs.

  8. Refer to the provided quick reference guide and utilities ROM
    for additional guidance on using the product.

  9. After completing the tests, power off the mainframe and
    disconnect it from the power source.

Configuration Guide

Network MasterTM Series

Network Master Pro MT1040A

400G (QSFP-DD) Multirate Module

MU104014A

400G (OSFP) Multirate Module

MU104015A

100G Multirate Module

MU104011A/MU100011A

10G Multirate Module

MU100010A

OTDR Module

MU100020A/MU100021A/MU100022A/MU100023A

Contents
The MT1040A is configured as a combination of various measurement modules. It is designed to support a combination of selected measurement modules and options with the main unit.
Contents
Network Master Pro MT1040A Main Frame ………………………………………………………………………………………………………………………………………………………………………………………………………….3 New Purchase Flowchart …………………………………………………………………………………………………………………………………………………………………………………………………………………………………………..4 New Purchase ……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………..6
Transport Module ………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….6 1-1 400G (QSFP-DD) Multirate Module MU104014A ………………………………………………………………………………………………………………………………………………………………………………6 1-1-1 Selecting Protocol Options……………………………………………………………………………………………………………………………………………………………………………………………………………..6 1-2 400G (OSFP) Multirate Module MU104015A………………………………………………………………………………………………………………………………………………………………………………………7 1-2-1 Selecting Protocol Options……………………………………………………………………………………………………………………………………………………………………………………………………………..7 1-3 100G Multirate Module MU104011A …………………………………………………………………………………………………………………………………………………………………………………………………..8 1-3-1 Selecting Protocol Options……………………………………………………………………………………………………………………………………………………………………………………………………………..8 1-4 10G Multirate Module MU100010A……………………………………………………………………………………………………………………………………………………………………………………………………..9 1-4-1 Selecting Protocol Options……………………………………………………………………………………………………………………………………………………………………………………………………………..9 1-5 100G Multirate Module MU100011A ……………………………………………………………………………………………………………………………………………………………………………………………….. 10 1-5-1 Selecting Protocol Options………………………………………………………………………………………………………………………………………………………………………………………………………….. 10 1-6 Selecting Optical Transceiver for Transport Module……………………………………………………………………………………………………………………………………………………………………….. 11 1-7 Selecting Transport Test Option…………………………………………………………………………………………………………………………………………………………………………………………………………. 12
OTDR Module………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………13 2-1 OTDR Module 1310/1550 nm SMF MU100020A ……………………………………………………………………………………………………………………………………………………………………………. 13 2-1-1 Selecting Dynamic Range ……………………………………………………………………………………………………………………………………………………………………………………………………………. 13 2-1-2 Selecting Polish Type/Connector Adapter………………………………………………………………………………………………………………………………………………………………………………… 13 2-1-3 Selecting Visible Light Source Option……………………………………………………………………………………………………………………………………………………………………………………….. 13 2-2 OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A ………………………………………………………………………………………………………………………………………………. 14 2-2-1 Selecting Dynamic Range ……………………………………………………………………………………………………………………………………………………………………………………………………………. 14 2-2-2 Selecting Polish Type/Connector Adapter………………………………………………………………………………………………………………………………………………………………………………… 14 2-2-3 Selecting Visible Light Source Option……………………………………………………………………………………………………………………………………………………………………………………….. 14 2-3 OTDR Module 1310/1550/1625 nm SMF MU100022A………………………………………………………………………………………………………………………………………………………………….. 15 2-3-1 Selecting Dynamic Range …………………………………………………………………………………………………………………………………………………………………………………………………………….15 2-3-2 Selecting Polish Type/Connector Adapter………………………………………………………………………………………………………………………………………………………………………………… 15 2-3-3 Selecting Visible Light Source Option……………………………………………………………………………………………………………………………………………………………………………………….. 15 2-4 OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A ………………………………………………………………………………………………………………………………………………………….. 16 2-4-1 Selecting Dynamic Range ……………………………………………………………………………………………………………………………………………………………………………………………………………. 16 2-4-2 Selecting Polish Type/Connector Adapter………………………………………………………………………………………………………………………………………………………………………………… 16 2-4-3 Selecting Visible Light Source Option……………………………………………………………………………………………………………………………………………………………………………………….. 16 2-5 Selecting MU100020A/MU100021A/MU100022A/MU100023A Options……………………………………………………………………………………………………………………………………. 17 2-5-1 OTDR Module Conversion Connector Adapters ……………………………………………………………………………………………………………………………………………………………………… 17 2-5-2 Optical Fiber Conversion Adapters…………………………………………………………………………………………………………………………………………………………………………………………….. 17 2-5-3 Others …………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….. 17
Common Application Parts, Extended Warranty Services and Remote Software Service……………………………………………………………………………………………………………………… 18 3-1 MT1040A Power Supply Option …………………………………………………………………………………………………………………………………………………………………………………………………………. 18 3-2 MT1040A Selecting Common Application Parts………………………………………………………………………………………………………………………………………………………………………………. 18 3-3 MT1040A Selecting Extended Warranty Services…………………………………………………………………………………………………………………………………………………………………………….. 20 3-4 Remote Software Service……………………………………………………………………………………………………………………………………………………………………………………………………………………… 21
Additional Purchases Flowchart……………………………………………………………………………………………………………………………………………………………………………………………………………………………. 22 Additional Purchases ……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………… 24
Adding New Options to Previously Purchased MT1040A …………………………………………………………………………………………………………………………………………………………………………… 24 4-1 Adding Test Protocols for Transport Module…………………………………………………………………………………………………………………………………………………………………………………… 24 4-2 Adding Main Frame Options for Transport Function ……………………………………………………………………………………………………………………………………………………………………… 29 4-3 Adding Transport Module……………………………………………………………………………………………………………………………………………………………………………………………………………………. 29 4-4 Adding OTDR Module …………………………………………………………………………………………………………………………………………………………………………………………………………………………. 29 4-5 Adding MX109020A Option………………………………………………………………………………………………………………………………………………………………………………………………………………… 29
Configuration Examples ……………………………………………………………………………………………………………………………………………………………………………………………………………………………………. 30 Order Sheet ………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….31 Method for Adding Measurement Modules………………………………………………………………………………………………………………………………………………………………………………………………….. 32
2

Network Master Pro MT1040A Main Frame

Network Master Pro MT1040A: Main Frame
The Network Master Pro MT1040A is a multiplatform designed for field testing that is configured using a combination of transport and optical. The Main Frame controls the test modules which can be changed freely to any custom configuration matching the users testing requirements.

9-inch active TFT display and touch screen

Power switch

MT1040A Main Unit

Model/Order No. MT1040A
MT1040A-006
B0745A B0771A*3 G0418A G0413A W4039AE Z1746A Z2077A Z2082A

Name Network Master Pro
Standard Accessories
High Power Supply1: Line Cord2: Softcase: MT1040A Rear Panel kit: AC Adaptor: Li-ion Battery: Quick Reference Guide: Stylus: Utilities ROM: Handle:

1 pc 1 pc 1 pc 1 pc 1 pc 2 pcs 1 pc 1 pc 1 pc 1 pc

Software Option*4

Model/Order No. MT1040A-003*5 MT1040A-011

Name Connectivity for WLAN/Bluetooth Site Over Remote Access Connect

AUX (D-SUB 15 pin)

Clock Input

DC Input (19 Vdc)

USB A USB Ethernet Service Interface Mini-B

*1: The presence of the MT1040A-006 option can be recognized at the top right
of the front panel. To retrofit it, please contact sales representative.

Without MT1040A-006

With in MT1040A-006

2: One line cord is attached to the area to shipment. 3: Composed of B0720A, B0730A, B0731A, B0740A and B0741A.

Module Configuration

Option for Two Transport Modules*6

Model/Order No. MT1040A-020

Name Activate for 400G Dual/100G Quad Option
Standard Accessories

G0419A

AC Adapter (400 W)

*4: These options can be retrofitted.
The Model/Order No. of retrofit options is “-3*”. Example
MT1040A-003 Connectivity for WLAN/Bluetooth becomes MT1040A-303 Connectivity for WLAN/Bluetooth Retrofit. When retrofitting an option, please either specify one of the following media along with the relevant option, or Web download.
Z1849A: DVD-ROM for Retrofit Options Z1850A: USB Stick for Retrofit Options
5: WLAN is available for certified countries and regions including USA, Japan and
EU countries. Please visit the Anritsu web site for updated information.
*6: Can be added to main unit in which MT1040A-006 already installed. However,
battery operation is not possible when installing two transponder modules together.

2U

400G (QSFP-DD) Multirate Module MU104014A 400G (OSFP) Multirate Module MU104015A

100G Multirate Module MU104011A

10G Multirate Module MU100010A

3U

100G Multirate Module MU100011A

1310/1550 nm SMF MU100020A 1310/1550/850/1300 nm SMF/MMF MU100021A 1310/1550/1625 nm SMF MU100022A 1310/1550/1650 nm SMF MU100023A

4U

5U
3

New Purchase Flowchart

Use this flowchart to select options when purchasing a new MT1040A.

MT1040A Choose the mainframe and mainframe options.

Page 3

Select testing requirements Confirming comms quality such as OTN, Ethernet, etc.

Select the type of interface to measure (10G) Up to 10G including PDH with independent dual port. (100G Single) 100G, 40G and 25G with single port. Up to 10G are with two ports which are restricted to be same protocol(Ethernet, OTN, FC, SDH/SONET) (100G Dual) Up to 100G with independent dual port. (200G/400G) 200G/400G single port.

10G

100G Single

100G Dual

200G/400G

Choose MU100010A Page 9

Choose MU100011A Page 10

Unit size:
1U

Choose MU104011A Page 8

Choose MU104014A for QSFP-DD 400G/200G 100G Dual
Page 6
Choose MU104015A for OSFP, 400G, 100G Single
Page 7

Unit size:
2U

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-4-1 Selecting Protocol Options.
Page 9

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-5-1 Selecting Protocol Options.
Page 10

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-3-1 Selecting Protocol Options.
Page 8

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-1-1 (MU104014A) or 1-2-1 (MU104015A) Selecting Protocol Options.
Page 6, 7

Select Optical I/F Select the model for choosing the optical module frequency and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.
Select Transport Test Options Select the model for choosing the required options from 1-7 Selecting Transport Test Option.

Page 11 Page 12

Selecting Main Frame Accessories Check the main frame power supply from 3-1 MT1040A power supply option. Select the main frame application parts from 3-2 MT1040A Selecting Common Application Parts. Select the model from 3-4 Remote Software Service. Select the model for the extended hardware warranty from 3-3 MT1040A Selecting Extended Warranty
Page 18 to 21

Record the purchased model and name in the MT1040A configuration confirmation order sheet.

Page 30

4

Checking optical fiber breaks and quality

Select Optical Fiber Select the type of optical fiber to measure Single Model only Both Single and Multimode fiber
Single Model only

Both Single and Multimode fiber

2 Wavelength (1310/1550 nm)
Choose MU100020A Page 13

Wavelength select
3 Wavelength (1310/1550/ 1625 nm)
Choose MU100022A Page 15

3 Wavelength (1310/1550/ 1650 nm)
Choose MU100023A Page 16

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-1-1 Selecting Dynamic Range.
Page 13

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-3-1 Selecting Dynamic Range.
Page 15

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-4-1 Selecting Dynamic Range.
Page 16

Select Connector Select the model with the required connector type from 2-1-2 Selecting Polish Type/ Connector Adapter.
Page 13

Select Connector Select the model with the required connector type from 2-3-2 Selecting Polish Type/ Connector Adapter.
Page 15

Select Connector Select the model with the required connector type from 2-4-2 Selecting Polish Type/ Connector Adapter.
Page 16

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-1-3 Selecting Visible Light Source Option.
Page 13

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-3-3 Selecting Visible Light Source Option.
Page 15

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-4-3 Selecting Visible Light Source Option.
Page 16

Selecting OTDR Test Options Select the models with the option choices from 2-5-1 OTDR Module Conversion Connector Adapters, 2-5-2 Optical Fiber Conversion Adapters, and 2-5-3 Others.
Page 17

Choose MU100021A Page 14
Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-2-1 Selecting Dynamic Range.
Page 14

Unit size:
1U

Select Connector Select the model with the required connector type from 2-2-2 Selecting Polish Type/ Connector Adapter.
Page 14

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-2-3 Selecting Visible Light Source Option.
Page 14

5

New Purchase
Transport Module

1-1 400G (QSFP-DD) Multirate Module MU104014A

Model/Order No.

Name

MU104014A

400G (QSFP-DD) Multirate Module

Standard Accessories

B0768A

ESD Box:

1 pc

The 400G (QSFP-DD) Multirate Module MU104014A supports

W4039AE

Transport Module Quick Reference Guide:

1 pc

communications network technologies from 10 Mbps to 100 Gbps with

dual ports and from 200 Gbps to 400 Gbps with single port. It has the

functions and performance required for network I&M tests. In addition,

optional test protocols can be selected and added. This excellent

expandability helps cut initial capital costs and supports introduction of

new functions matching the work schedule.

1-1-1 Selecting Protocol Options
The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.

MU104014A Transport Technology Ethernet

Bit Rate
No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-XDR4 N-Port BERT eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

10G or less 2 (Dual Channel)

16G or 25G 2 (Dual Channel)

MU104014A-012 Ethernet up to 25G Dual Channel

MU104014A-012

Ethernet up to 25G

Dual Channel

MU104014A-020

TCP Throughput*2

MU104014A-012 Ethernet up to 25G Dual Channel

MU104014A-052

OTN up to 10G

Dual Channel

MU104014A-063

ODU Multiplexing/

Multi Stage*3

MU104014A-074 CPRI/OBSAI up to 25G Dual Channel

MU104014A-092 FC up to 16G Dual Channel

MU104014A-082

SDH/SONET up to

10G Dual Channel

40G or 100G 1 (Single Channel) 2 (Dual Channel)

MU104014A-013 Ethernet 40G Single Channel
MU104014A-015 Ethernet 100G Single Channel

MU104014A-014 Ethernet 40G Dual Channel
MU104014A-016 Ethernet 100G Dual Channel

MU104014A-013
Ethernet 40G Single Channel
MU104014A-015
Ethernet 100G Single Channel

MU104014A-014
Ethernet 40G Dual Channel
MU104014A-016
Ethernet 100G Dual Channel

MU104014A-053 OTN 40G
Single Channel
MU104014A-055 OTN 100G
Single Channel

MU104014A-054 OTN 40G
Dual Channel
MU104014A-056 OTN 100G
Dual Channel

MU104014A-063 ODU Multiplexing/Multi Stage*3

MU104014A-084*4 STM-256/OC-768 Client Signal

200G or 400G 1 (Single Channel) MU104014A-031
Ethernet 200G Single Channel MU104014A-033 Ethernet 400G Single Channel
— — MT104014A-034 4×100G N Port BERT







1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104014A-012. 3: Requires that at least one of the following option is installed: MU104014A-052, MU104014A-053, MU104014A-054, MU104014A-055, MU104014A-056. 4: MU104014A does not have a physical interface of the option. The option is required for client signal mapped in the OTN. 6

New Purchase
Transport Module

1-2 400G (OSFP) Multirate Module MU104015A

Model/Order No.

Name

MU104015A

400G (OSFP) Multirate Module

Standard Accessories

B0768A

ESD Box:

1 pc

The 400G (OSFP) Multirate Module MU104015A supports communications

W4039AE

Transport Module Quick Reference Guide:

1 pc

network technologies from 10 Mbps to 25 Gbps with dual ports and

from 40 Gbps to 400 Gbps with single port. It has the functions and

performance required for network I&M tests. In addition, optional test

protocols can be selected and added. This excellent expandability helps

cut initial capital costs and supports introduction of new functions

matching the work schedule.

1-2-1 Selecting Protocol Options
The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.

MU104015A Transport Technology Ethernet

Bit Rate
No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-2FR4 N-Port BERT eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan

ODU Multiplexing Addition
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET
Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

10G or less 2 (Dual Channel)

16G or 25G 2 (Dual Channel)

MU104015A-012 Ethernet up to 25G Dual Channel

MU104015A-012

Ethernet up to 25G

Dual Channel

MU104015A-020 TCP Throughput*2

MU104015A-012 Ethernet up to 25G Dual Channel

MU104015A-052

OTN up to 10G

Dual Channel

MU104015A-063

ODU Multiplexing/

Multi Stage*3

MU104015A-074 CPRI/OBSAI up to 25G Dual Channel

MU104015A-092 FC up to 16G Dual Channel

MU104015A-082

SDH/SONET up to

10G Dual Channel

40G or 100G 1 (Single Channel) 2 (Dual Channel)

MU104015A-013

Ethernet 40G

Single Channel

MU104015A-015

Ethernet 100G

Single Channel

MU104015A-013

Ethernet 40G

Single Channel

MU104015A-015

Ethernet 100G

Single Channel

MU104015A-053

OTN 40G

Single Channel

MU104015A-055

OTN 100G

Single Channel

MU104015A-063

ODU Multiplexing/

Multi Stage*3

MU104015A-084*4 STM-256/OC-768 Client Signal

400G 1 (Single Channel)
— MU104015A-033
Ethernet 400G Single Channel
— — MU104015A-035 2×200G N Port BERT — —
— — —


1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104015A-012. 3: Requires that at least one of the following option is installed: MU104015A-052, MU104015A-053, MU104015A-055. 4: MU104015A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.

7

New Purchase
Transport Module

1-3 100G Multirate Module MU104011A

Model/Order No.

Name

MU104011A

100G Multirate Module

Standard Accessories

B0768A

ESD Box:

1 pc

The 100G Multirate Module MU104011A supports communications

W4039AE

Transport Module Quick Reference Guide:

1 pc

network technologies from 10 Mbps to 100 Gbps with dual ports. It has

the functions and performance required for network I&M tests.

In addition, optional test protocols can be selected and added.

This excellent expandability helps cut initial capital costs and supports

introduction of new functions matching the work schedule.

1-3-1 Selecting Protocol Options
The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.

MU104011A Transport Technology Ethernet

Bit Rate
No. of Measurement Ports*1

10G or less 2 (Dual Channel)

16G or 25G 2 (Dual Channel)

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

MU104011A-012 Ethernet up to 25G Dual Channel

Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) eCPRI/RoE (IEEE1914.3)

MU104011A-012

Ethernet up to 25G

Dual Channel

MU104011A-020

TCP Throughput*2

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

MU104011A-012 Ethernet up to 25G Dual Channel

OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

MU104011A-052

OTN up to 10G

Dual Channel

MU104011A-063

ODU Multiplexing/

Multi Stage*3

MU104011A-074 CPRI/OBSAI up to 25G Dual Channel

MU104011A-092 FC up to 16G Dual Channel

MU104011A-082

SDH/SONET up to 10G

Dual Channel

40G or 100G

1 (Single Channel)

2 (Dual Channel)

MU104011A-013 Ethernet 40G Single Channel
MU104011A-015 Ethernet 100G Single Channel

MU104011A-014 Ethernet 40G Dual Channel
MU104011A-016 Ethernet 100G Dual Channel

MU104011A-013 Ethernet 40G Single Channel
MU104011A-015 Ethernet 100G Single Channel

MU104011A-014 Ethernet 40G Dual Channel
MU104011A-016 Ethernet 100G Dual Channel

MU104011A-053 OTN 40G Single Channel
MU104011A-055 OTN 100G Single Channel

MU104011A-054 OTN 40G Dual Channel
MU104011A-056 OTN 100G Dual Channel

MU104011A-063 ODU Multiplexing/Multi Stage*3

MU104011A-084*4 STM-256/OC-768 Client Signal

1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104011A-012. 3: Requires that at least one of the following option is installed: MU104011A-052, MU104011A-053, MU104011A-054, MU104011A-055, MU104011A-056. 4: MU104011A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
8

New Purchase
Transport Module

1-4 10G Multirate Module MU100010A

The 10G Multirate Module MU100010A supports communications network technologies with speeds ranging from 1.5 Mbps to 10 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.

Model

Name

MU100010A

10G Multirate Module

Standard Accessories

W3935AE B0692A*

MT1000A Transport Quick Reference Guide:

1 pc

ESD Box (for optical modules):

1 pc

*: Up to four SFP+/SFPs can be stored.

1-4-1 Selecting Protocol Options
The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.

MU100010A

Bit Rate

Transport Technology

No. of Measurement Ports*1

Ethernet

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through, Channel Stat

TCP Throughput Test (RFC 6349, iPerf)

eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition4
ODU Flex Addition
5
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET, PDH/DSn
PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan

Less than 5G 2 (Dual Channel)

From 6G to 10G

1 (Single Channel)

2 (Dual Channel)

MU100010A-001 Up to 2.7G Dual Channel

MU100010A-011 Ethernet 10G Single Channel

MU100010A-012 Ethernet 10G Dual Channel

MU100010A-020 TCP Throughput

MU100010A-001 Up to 2.7G Dual Channel

MU100010A-011 Ethernet 10G Single Channel

MU100010A-012 Ethernet 10G Dual Channel

MU100010A-001 Up to 2.7G Dual Channel

MU100010A-051 OTN 10G Single Channel

MU100010A-052 OTN 10G Dual Channel

MU100010A-061 ODU Multiplexing

MU100010A-062 ODU Flex

MU100010A-071
CPRI/OBSAI Up to 5G Dual Channel

MU100010A-072
CPRI/OBSAI 6G to 10G Single Channel

MU100010A-073
CPRI/OBSAI 6G to 10G Dual Channel

MU100010A-002 FC 1G 2G 4G Dual Channel

MU100010A-091 FC 8G 10G Single Channel

MU100010A-092 FC 8G 10G Dual Channel

MU100010A-001 Up to 2.7G Dual Channel

MU100010A-081
STM-64 OC-192 Single Channel

MU100010A-082
STM-64 OC-192 Dual Channel

1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Please see the datasheet for supported OTN mapping. 3: When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the
MU100010A-051/052 (for physical port) and the MU100010A-081/082 (for client signal) are required.
4: When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel.
*5: When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.

9

New Purchase
Transport Module

1-5 100G Multirate Module MU100011A

The 100G Multirate Module MU100011A supports communications network technologies with speeds ranging from 10 Mbps to 100 Gbps. It has the functions and performance required for network I&M tests. In addition, optional test protocols can be selected and added. This excellent expandability helps cut initial capital costs and supports introduction of new functions matching the work schedule.

Model

Name

MU100011A

100G Multirate Module

Standard Accessories

W3935AE

MT1000A Transport Quick Reference Guide:

1 pc

B0763A*

ESD Box (for optical modules):

1 pc

*: One CFP4 plus either up to two QSFP28s or up to four SFP/SFP+s can be
stored.

1-5-1 Selecting Protocol Options

The protocol options are software options for transport technologies supporting each bit rate. At least one Channel option must be selected from the following list.

MU100011A Transport Technology Ethernet

Bit Rate No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery

Pass-through, Channel Stat TCP Throughput Test (RFC 6349, iPerf)

Measurement using 100GBASE-SR

eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

Measurement using 100GBASE-SR
OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan ODU Multiplexing Addition2, 4 ODU Flex Addition2, 5 CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring SDH/SONET PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan

Up to 10G

1

2

(Single Channel) (Dual Channel)

Higher than 10G

1

2

(Single Channel)

(Dual Channel)

MU100011A-017*8 Ethernet 25G Single Channel

MU100011A-001 MU100011A-003

MU100011A-013*9

Up to 10G

Up to 10G

Ethernet 40G Single Channel

Single Channel

Dual Channel

MU100011A-015*9 Ethernet 100G Single Channel

MU100011A-020 TCP Throughput

MU100011A-023*8

RS-FEC for 100GBASE-SR4

MU100011A-015*9

Ethernet 100G Single Channel

MU100011A-001 MU100011A-003

Up to 10G

Up to 10G

Single Channel

Dual Channel

MU100011A-0178 Ethernet 25G Single Channel
MU100011A-013
9 Ethernet 40G Single Channel
MU100011A-0159 Ethernet 100G Single Channel
MU100011A-023
8 RS-FEC for 100GBASE-SR4
MU100011A-015*9 Ethernet 100G Single Channel

MU100011A-0757, 8 eCPRI/RoE 25G Dual Channel
— —

MU100011A-001 MU100011A-003

Up to 10G

Up to 10G

Single Channel

Dual Channel

MU100011A-053 OTN 40G Single Channel
MU100011A-055 OTN 100G Single Channel

— —

MU100011A-063 ODU Multiplexing/Multi Stage

MU100011A-062 ODU Flex

MU100011A-071 CPRI/OBSAI Up to 10G
Single Channel

MU100011A-072 CPRI/OBSAI Up to 10G Dual Channel

MU100011A-073 CPRI 12/25G Single Channel

MU100011A-074 CPRI 12/25G Dual Channel

MU100011A-004 MU100011A-005

Up to 10G FC

Up to 10G FC

Single Channel

Dual Channel

MU100011A-091 FC 16G Single Channel

MU100011A-001 MU100011A-003

MU100011A-083*6

Up to 10G

Up to 10G

STM-256/OC-768

Single Channel

Dual Channel

Client Signal

*1:

The channel is not related to the physical port position. choose either of the two physical ports assigned to the

The user can freely option via software.

For a dual channel setup, the two different ports of one protocol can operate

simultaneously, or two different single channel options can operate simultaneously.

**23::

Please see the datasheet for supported OTN mapping. When using the OTN function, the channel can be used mapped to OTN.

as

client

signal

For example, when mapping STM-256/OC-768 to OTU4, both the MU100011A-055

(for physical port) and the MU100011A-083 (for client signal) are required.

*4:

When the ODU Multiplexing/Multistage mapping measurements are supported.

option

is

installed,

OTN

multistage

This one option supports both single channel and dual channel.
10

*5:

This over

mapping function is based on the ODU Flex standard for OTN networks and supports client signals of any speed.

transmissions

This one option supports both single channel and dual channel.

*6: The MU100011A has no STM-256/OC-768 PHY interface; it can be used for
OTN client signals.

***789:::

Option supports eCPRI/RoE FEC selectable On/Off. FEC is always Off.

protocol

tests

only.

New Purchase
Transport Module
1-6 Selecting Optical Transceiver for Transport Module When using any transport modules for testing optical interfaces, perform the test by installing the optical modules matching the test standards in the QSFP- DD/OSFP/QSFP28/SFP/SFP+/SFP28 slots. The following table lists the modules and supported standards.

MU104014A MU104015A MU104011A MU100010A MU100011A 100M Ethernet 156M STM-1 614M CPRI 622M STM-4 768M OBSAI 1GFC 1.23G CPRI 1.25G Ethernet 1.54G OBSAI 2GFC 2.46G CPRI 2.488G STM-16 2.67G OTU1 3.07G CPRI OBSAI 4GFC 4.92G CPRI 6.14G CPRI OBSAI 8GFC 9.83G CPRI 9.95G STM-64 10.1G CPRI 10.3G Ethernet 10GFC 10.7G OTU2 11.05G OTU1e 11.09G OTU2e 11.27G OTU1f 11.3G OTU2f 16GFC 25G Ethernet 40G Ethernet 40G OTN 100G Ethernet 100G OTN 200G Ethernet 400G Ethernet

Model/ Order
No.

Name

Form Factor

G0332A

100M FX 1310 nm MM SFP

SFP

G0319A

Up to 2.7G 1310 nm 15 km SFP

SFP

G0320A

Up to 2.7G 1310 nm 40 km SFP

SFP

G0321A

Up to 2.7G 1550 nm 80 km SFP

SFP

G0328A

1G/2G/4G FC 850 nm SFP

SFP

G0322A

1G/2G/4G FC 1310 nm SFP

SFP

G0323A

1G/2G/4G FC 1550 nm SFP

SFP

G0315A

10G LR/LW 1310 nm SFP+

SFP+

G0316A

10G ER/EW 1550 nm 40 km SFP+

SFP+

G0318A

10G ZR/ZW 1550 nm 80 km SFP+

SFP+

G0329A

10G LR 1310 nm SFP+

SFP+

G0356A

8G FC/10G SR 850 nm SFP+

SFP+

G0386A

16GFC SR 850 nm SFP+

SFP+

1310 nm, MM, 2 km

G0387A

16GFC LR 1310 nm SFP+

SFP+

G0388A

25G SR 850 nm SFP28

SFP28

G0389A

25G LR 1310 nm SFP28

G0359A

40G SR4 850 nm QSFP+

G0334A

40G LR4 1310 nm QSFP+

G0366A

100G SR4 850 nm QSFP28

SFP28 QSFP+ QSFP+ QSFP28

G0364A

100G LR4 1310 nm QSFP28

G0365A

100G LR4 Dual Rate 1310 nm QSFP28

G0426A

QSFP28 100GBASE-DR

QSFP28 QSFP28 QSFP28

G0427A

QSFP28 100GBASE-FR1

QSFP28

G0421A

QSFP56 200GBASE-LR4

QSFP56

G0420A

QSFP56 200GBASE-FR4

QSFP56

G0402A

QSFP-DD 400GBASE-DR4

QSFP-DD

G0403A

QSFP-DD 400GBASE-FR4

QSFP-DD

G0404A

QSFP-DD 400GBASE-LR4

QSFP-DD

G0405A

OSFP 400GBASE-DR4

OSFP

G0406A

OSFP 400GBASE-FR4

OSFP

G0425A

QSFP 400GBASE-2FR4

OSFP

G0428A

QSFP-DD 400GBASE-DR4+

QSFP-DD

1310 nm, SM, 15 km 1310 nm, SM, 40 km 1550 nm, SM, 80 km
850 nm, MM, 0.5 km 1310 nm, SM, 10 km 1550 nm, SM, 40 km
1310 nm, SM, 10 km

1310 nm, SM, 10 km 1550 nm, SM, 40 km 1550 nm, SM, 80 km
850 nm, MM, 0.3 km

850 nm, MM, 0.5 km 1310 nm, SM, 10 km
850 nm, MM, 0.5 km 1310 nm, SM, 10 km
850 nm, MM, 0.1 km 1310 nm, SM, 10 km
850 nm, MM, 0.1 km 1310 nm, SM, 10 km 1310 nm, SM, 10 km 1310 nm, SM, 0.5 km 1310 nm, SM, 2 km
1310 nm, SM, 10 km 1310 nm, SM, 2 km
1310 nm, SM, 0.5 km 1310 nm, SM, 2 km 1310 nm, SM, 10 km 1310 nm, SM, 0.5 km 1310 nm, SM, 2 km 1310 nm, SM, 2 km 1310 nm, SM, 0.5 km
11

New Purchase
Transport Module

1-7 Selecting Transport Test Option

These options are used in combination with the transport module. Choose options matching the customer’s test requirements. Additionally today, these options cannot be used in combination with the OTDR module.

Model G0325A

GPS Receiver

Name

Notes It is required when measuring one-way latency at Ethernet tests.

W4038AE W4041AE Z1821A J1583A J1584A

MT1040A Transport Module Operation Manual MT1000A/MT1100A/MT1040A Remote Scripting Operation Manual Utilities in USB Stick Optical Attenuator 10 dB LC/PC to LC/PC RJ45 Cable 3 m

Printed manual Printed manual USB memory with operation manual, remote scripts instruction manual, etc.

J1585A J1586A J1588A J1589A J1591A

RJ48 to Crocodile Clips Cable 3 m RJ48 to Crocodile Clips Cable 20 dB ATT 3 m BNC Cable 2.5 m BNC to 1.6/5.6 Cable 2.5 m RJ48 to Two 3-pin Banana Plug Cable 2.5 m

E1 interface cable. E1 interface cable. E1, E3, E4, DS3, STM-1e, STS-3 interface cable. Impedance: 75 E1, E3, E4, DS3, STM-1e, STS-3 interface cable. Impedance: 75 E1 interface cable.

J1597A J1598A

RJ48 Balanced PDH Cable Crossed 3 m Bantam Cable 3 m

E1 interface cable. DS1 interface cable.

12

New Purchase
OTDR Module
2-1 OTDR Module 1310/1550 nm SMF MU100020A

OPM Port

SM Port

Model

Name

MU100020A

OTDR Module 1310/1550 nm SMF

Standard Accessories

J1693A

Universal Connector 2.5 mm for OPM:

1 pc

The OTDR Module 1310/1550 nm SMF MU100020A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR, FTTA, and

J1694A

Universal Connector 1.25 mm for OPM:

1 pc

OLTS measurements required for checking optical fiber. Select a model

W3811AE

Quick Reference Guide:

1 pc

with the dynamic range matching the test requirements. Additionally,

combined used with the visible light source options support visual

confirmation of fiber breaks, etc.

2-1-1 Selecting Dynamic Range

The MU100020A is available in three models with different dynamic ranges matching the test environment. Select the One matching the test requirements.

Wavelength: Dynamic Range 1310/1550 nm: 39/37.5 dB 1310/1550 nm: 42/41 dB 1310/1550 nm: 46/46 dB

MU100020A-020 MU100020A-021 MU100020A-022

Model

Name Standard Dynamic Range Enhanced Dynamic Range High-Performance Dynamic Range

2-1-2 Selecting Polish Type/Connector Adapter The MU100020A is available in a total of five models (3 UPC and 2 APC) as listed below. Specify the required connector type at ordering. The specified connector is provided as a standard accessory. The polish type cannot be changed after purchase.
Polish Type

UPC

APC

Connector Adapter

Model

UPC Ultra Physical Contact

Model

APC Angled Physical Contact

FC Connector

MU100020A-010 MU100020A-037

MU100020A-011 MU100020A-025

DIN 47256 Connector

MU100020A-010 MU100020A-039

SC Connector

MU100020A-010 MU100020A-040

MU100020A-011 MU100020A-026

2-1-3 Selecting Visible Light Source Option

Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.

Model MU100020A-002

Name Visual Fault Locator

Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm

J1335A

MU/LC Connector Adapter

Required conversion adapter for inserting LC (1.25 mm) optical fiber

13

New Purchase
OTDR Module
2-2 OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A

OPM Port

MM Port SM Port

The OTDR Module 1310/1550/850/1300 nm SMF/MMF MU100021A is an OTDR module for single and multimode fiber use. It supports all-inone OTDR, FTTA, and OLTS measurements required for checking optical fiber. Select a model with the dynamic range matching the test requirements. Additionally, combined used with the visible light source options support visual confirmation of fiber breaks, etc.

Model MU100021A
J1693A J1694A W3811AE

Name

OTDR Module 1310/1550/850/1300 nm SMF/MMF

Standard Accessories

Universal Connector 2.5 mm for OPM:

1 pc

Universal Connector 1.25 mm for OPM:

1 pc

Quick Reference Guide:

1 pc

2-2-1 Selecting Dynamic Range

The MU100021A has a fixed dynamic range; select the following model.

Wavelength: Dynamic Range 1310/1550/850/1300 nm: 42/41/29/28 dB

MU100021A-021

Model

Name Enhanced Dynamic Range

2-2-2 Selecting Polish Type/Connector Adapter
The MU100021A is available in a total of five models (3 UPC and 2 APC) as listed below. Specify the required connector type at ordering. Two specified connectors (for SMF and MMF ports) are provided as standard accessories. The polish type cannot be changed after purchase.

Connector Adapter

Polish Type

UPC*1

Model

UPC Ultra Physical Contact
MM Port

UPC Ultra Physical Contact
SM Port

APC1, 2 (SM port only, MM port is UPC)
Model

UPC Ultra Physical Contact
MM Port

APC Angled Physical Contact
SM Port

FC Connector

MU100021A-010 MU100021A-037

MU100021A-011 MU100021A-025

DIN 47256 Connector

MU100021A-010 MU100021A-039

SC Connector

MU100021A-010 MU100021A-040

MU100021A-011 MU100021A-026

1: Different connector adapter types cannot be specified for the SMF and MMF ports. 2: There is no APC polish type for the MMF port. As a result, this connector adapter polish type is UPC.

2-2-3 Selecting Visible Light Source Option

Breaks in the optical fiber can be detected by eye using this light source. This option cannot be added by retrofit after purchase.

Model MU100021A-002

Name Visual Fault Locator

Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm.

J1335A

MU/LC Connector Adapter Required conversion adapter for inserting LC (1.25 mm) optical fiber

14

New Purchase
OTDR Module
2-3 OTDR Module 1310/1550/1625 nm SMF MU100022A

OPM Port

SM Port

Model

Name

MU100022A

OTDR Module 1310/1550/1625 nm SMF

Standard Accessories

J1693A

Universal Connector 2.5 mm for OPM:

1 pc

The OTDR Module 1310/1550/1625 nm SMF MU100022A is an OTDR module for single mode fiber use only. It supports all-in-one OTDR,

J1694A

Universal Connector 1.25 mm for OPM:

1 pc

FTTA, and OLTS measurements required for checking optical fiber.

W3811AE

Quick Reference Guide:

1 pc

Additionally, combined used with the visible light source options

support visual confirmation of fiber breaks, etc.

2-3-1 Selecting Dynamic Range

The MU100022A has a fixed dynamic range; select the following model.

Wavelength: Dynamic Range 1310/1550/1625 nm: 46/46/44 dB

MU100022A-022

Model

Name High-Performance Dynamic Range

2-3-2 Selecting Polish Type/Connector Adapter The MU100022A is available in a total of five models (3 UPC and 2 APC) as listed below. Specify the required connector type at ordering. The specified connector is provided as a standard accessory. The polish type cannot be changed after purchase.
Polish Type

UPC

APC

Connector Adapter

Model

UPC Ultra Physical Contact

Model

APC Angled Physical Contact

FC Connector

MU100022A-010 MU100022A-037

MU100022A-011 MU100022A-025

DIN 47256 Connector

MU100022A-010 MU100022A-039

SC Connector

MU100022A-010 MU100022A-040

MU100022A-011 MU100022A-026

2-3-3 Selecting Visible Light Source Option

Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.

Model MU100022A-002

Name Visual Fault Locator

Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm

J1335A

MU/LC Connector Adapter

Required conversion adapter for inserting LC (1.25 mm) optical fiber

15

New Purchase
OTDR Module

2-4 OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A

OPM Port

SM Port

SM Port

(1650 nm) (1310/1550 nm)

Model

Name

MU100023A

OTDR Module 1310/1550/1650 nm SMF

Standard Accessories

J1693A

Universal Connector 2.5 mm for OPM:

1 pc

The OTDR Module 1310/1550 nm, 1650 nm SMF MU100023A is an OTDR module for single mode fiber use only. It supports all-in-one

J1694A

Universal Connector 1.25 mm for OPM:

1 pc

OTDR, FTTA, and OLTS measurements required for checking optical

W3811AE

Quick Reference Guide:

1 pc

fiber. Additionally, combined used with the visible light source options

support visual confirmation of fiber breaks, etc.

2-4-1 Selecting Dynamic Range

The MU100023A has a fixed dynamic range; select the following model.

Wavelength: Dynamic Range 1310/1550 nm: 42/41 dB, 1650 nm: 35 dB

MU100023A-021

Model

Name Enhanced Dynamic Range

2-4-2 Selecting Polish Type/Connector Adapter The MU100023A is available in a total of five models (3 UPC and 2 APC) as listed below. Specify the required connector type at ordering. The specified connector is provided as a standard accessory. The polish type cannot be changed after purchase.
Polish Type

UPC*

APC*

Connector Adapter

Model

UPC Ultra Physical Contact

Model

APC Angled Physical Contact

FC Connector

MU100023A-010 MU100023A-037

MU100023A-011 MU100023A-025

DIN 47256 Connector

MU100023A-010 MU100023A-039

SC Connector

MU100023A-010 MU100023A-040

MU100023A-011 MU100023A-026

*: Different types of connector adapters cannot be selected for the SM port (1310/1550 nm) and the SM port (1650 nm).

2-4-3 Selecting Visible Light Source Option

Breaks in the optical fiber can be detected visually using this light source. This option cannot be added after purchase.

Model MU100023A-002

Name Visual Fault Locator

Notes For direct insertion of 2.5 mm (FC, SC, DIN) optical fiber with fixed diameter of 2.5 mm.

J1335A

MU/LC Connector Adapter

Required conversion adapter for inserting LC (1.25 mm) optical fiber

16

New Purchase
OTDR Module

2-5 Selecting MU100020A/MU100021A/MU100022A/MU100023A Options The OTDR Module connector is available in a total of five types (3 UPC and 2 APC). These connectors can be changed freely by the user. However, connectors with mismatched polish types cannot be used.

2-5-1 OTDR Module Conversion Connector Adapters

Model Name

J0617B (FC/UPC) Changeable Optical Connector (FC-PC)

UPC (Option 010), SM/MM Ports J0618E (DIN/UPC) Changeable Optical Connector (DIN)

J0619B (SC/UPC) Changeable Optical
Connector (SC)

APC (Option 011), SM Port

J0739A (FC/APC)

J1697A (SC/APC)

Changeable Optical Connector (FC-APC)

Changeable Optical Connector (SC-APC)

Form

2-5-2 Optical Fiber Conversion Adapters

Model

Name

J1530A SC Plug-in Converter (UPC (P)-APC (J))

Notes

SC/UPC SC/APC Conversion

(Physical contact)
10° to 25°

UPC (P)

(Angle physical contact)

APC (J)

J1531A SC Plug-in Converter (APC (P)-UPC (J))

(Angle physical contact)

APC (P)

SC/APC SC/UPC Conversion

UPC (J)

(Physical contact)
10° to 25°

J1532A FC Plug-in Converter (UPC (P)-APC (J))

(Physical contact)
10° to 25°

UPC (P)

FC/UPC FC/APC Conversion

(Angle physical contact)

APC (J)

J1533A FC Plug-in Converter (APC (P)-UPC (J)) J1534A LC-SC Plug-in Converter
(for SM, SC (P)-LC (J)) J1535A LC-SC Plug-in Converter
(for MM, SC (P)-LC (J))

(Angle physical contact)
APC (P)

(Physical contact)
10° to 25°

UPC (P)

(Physical contact)
10° to 25°

UPC (J)

FC/APC FC/UPC Conversion

UPC (J)

(Physical contact)
10° to 25°

SC/UPC LC/UPC Conversion. SM Fiber Only

UPC (J)

(Physical contact)
10° to 25°

SC/UPC LC/UPC Conversion. MM Fiber Only

(Physical contact)

UPC (P)

10° to 25°

2-5-3 Others

Model NETWORKS
W3810AE

Name

Notes

PC Emulation Software for Data Analysis and Reporting

Supports PC running Microsoft Windows 7 and Windows 10 to edit waveform data and create reports

MT1000A MU100020A Network Master Pro Operation Manual MT1000A and MU100020A/MU100021A/MU100022A/MU100023A operation manuals

17

New Purchase
Common Application Parts, Extended Warranty Services and Remote Software Service

3-1 MT1040A Power Supply Option Depending on module combination, it is necessary to order MT1040A-020 Activate for 400G Dual/100G Quad Option.

Without MT1040A-020 (Battery Operational)

With MT1040A-020

2U

3U

400G (QSFP-DD) Multirate Module MU104014A 400G (OSFP) Multirate Module MU104015A 100G Multirate Module MU104011A
10G Multirate Module MU100010A 100G Multirate Module MU100011A
1310/1550 nm SMF MU100020A 1310/1550/850/1300 nm SMF/MMF MU100021A 1310/1550/1625 nm SMF MU100022A 1310/1550/1650 nm SMF MU100023A

4U

5U

3-2 MT1040A Selecting Common Application Parts Various application parts make the MT1040A more convenient to use.
Battery Charger G0324A This is the charger for the MT1040A G0413A Li-ion battery.
Video Inspection Probe G0382A/G0306B Scratches and dirt on the connector end face are a major cause of degraded communications quality. The MT1040A has a built-in VIP function for analyzing the condition of the optical connector end face in the utility menu. When the VIP is connected, scratches and dirt on the optical connector end face are visualized (× 400) and the OK/NG status is evaluated based on the IEC61300-3-35 standard. Anritsu supports VIP Series G0382A (USB Autofocus Type) and G0306B (USB Standard Type).

G0382A

G0306B

Different tip types are used by the G0382A and G0306B.

Optical Connector End-face Inspection/Evaluation Screen

18

New Purchase
Common Application Parts, Extended Warranty Services and Remote Software Service

Accessories for MT1040A Dual-Module Configuration The size of the MT1040A depends on the module configuration. Choose the appropriate case.

Module Combination
Short (2U) Standard Transport (Type 2) (3U)

Mounting Skrews
B0730A

B0745A

Soft Case

B0772A

B0733A

Hard Case

B0773A

B0731A

+ Transport (Type 1) or OTDR Module (4U)

B0740A

Two Transport (type 2) Modules (5U) B0741A

345 (W) × 238 (H) × 480 (D) mm, 3.5 kg

495 (W) × 338 (H) × 663 (D) mm, 12.3 kg

MT1040A

B0733A Size of Each Hard Case for MT1040A

B0773A

Optical Cables Model
J1571A J1575A J1579A J1581A

Name Optical cable SM LC/PC to SC/PC 3 m Optical Cable SM LC/PC to FC/PC 3 m Optical Cable SM LC/PC to LC/PC 3 m Optical Cable MM LC/PC to LC/PC 3 m

MT1040A Module Connection Parts

Model

B0720A

Rear Panel

B0730A

Screw 2U

B0731A

Screw 3U

B0740A

Screw 4U

B0741A

Screw 5U

B0769A

MT1040A Screw Kit

Name

Single core (no paired cables) Single core (no paired cables) Single core (no paired cables) Single core (no paired cables)

Notes

Notes MT1040A Rear Panel 2 units screw set (Total 4 pcs) 3 units screw set (Total 4 pcs) 4 units screw set (Total 4 pcs) 5 units screw set (Total 4 pcs) Composed of B0730A, B0731A, B0740A and B0741A.

19

New Purchase
Common Application Parts, Extended Warranty Services and Remote Software Service

3-3 MT1040A Selecting Extended Warranty Services The standard warranty period is 1 year. An extended warranty can be purchased for the main frame and the test interface modules as listed below.

Model

Name

MT1040A

MT1040A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MT1040A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MT1040A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU104014A

MU104014A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU104014A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU104014A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU104015A

MU104015A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU104015A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU104015A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU104011A

MU104011A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU104011A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU104011A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU100010A

MU100010A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100010A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100010A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

Model

Name

MU100011A

MU100011A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100011A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100011A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU100020A

MU100020A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100020A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100020A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU100021A

MU100021A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100021A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100021A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU100022A

MU100022A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100022A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100022A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

MU100023A

MU100023A-ES210 2 Years Extended Warranty Service (standard 1 year + 1 year)

MU100023A-ES310 3 Years Extended Warranty Service (standard 1 year + 2 years)

MU100023A-ES510 5 Years Extended Warranty Service (standard 1 year + 4 years)

20

New Purchase
Common Application Parts, Extended Warranty Services and Remote Software Service

3-4 Remote Software Service The following licenses must be purchased to use the MX109020A Site Over Remote Access.

Mainframe Option License

Model/Order No. MT1040A-0031 MT1040A-0112

Name WLAN/Bluetooth Connect Site Over Remote Access Connect

1: WLAN is available for certified countries and regions including USA, Canada, Japan and EU countries. Please visit the Anritsu web site for updated information.
Although this product has not been approved by Bluetooth SIG, the supported frequencies are in the range assigned to Bluetooth® communications.
2: Validity period is unlimited. An open TCP port may be required to allow the MT1040A to be connected from an in-company LAN to MX109020A, depending on the
LAN security policy.

Subscription Option License

Model/Order No. MX109020A3, 5, 6, 7 MX109020A-TL0013, 4 MX109020A-0015 MX109020A-0025 MX109020A-003*8

Name Site Over Remote Access Basic License Site Over Remote Access 1 Year License Site Over Remote Access 8 Units Site Over Remote Access Unlimited Units Centralized Data Management

3: We recommend purchasing a 1-year license in addition to the basic license. 4: When extending the usage period, we recommend purchasing in 1-year license periods 5: Up to two measuring instruments can be remotely controlled simultaneously with the basic license.
This number can be increased to up to 8 units by purchasing the MX109020A-001 option, and up to 100 units by purchasing the MX109020A-002 option.
6: You must agree to the service terms before purchasing SORA.
Refer to the service terms at the following URL: https: //www.anritsu.com/en- AU/test-measurement/support/downloads/manuals/dwl20059
7: This product cannot be used in some regions and countries; please read the service terms for more details. 8: Users must provide their own storage at the upload destination.

21

Additional Purchases Flowchart

Use this flowchart when adding modules and options to a previously purchased MT1040A.

Adding Functions Adding Protocol Options

Adding Transport Module

Confirm the serial numbers of the MU100010A/MU100011A/ MU104011A/MU104014A/ MU104015A.
Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 4-1 Adding Test Protocols for Transport Module.
Page 24 to 28
Select Optical I/F Select the model for choosing the optical module frequency and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.
Page 11

Select the type of interface to measure (10G) Up to 10G including PDH with independent dual port. (100G Single) 100G, 40G and 25G with single port. Up to 10G are with two ports which are restricted to be same protocol (Ethernet, OTN, FC,
SDH/SONET) (100G Dual) Up to 100G with independent dual port. (200G/400G) 200G/400G single port.

10G

100G Single

100G Dual

200G/400G

Choose MU100010A Page 9

Choose MU100011A Page 10

Choose MU104011A Page 8

Choose MU104014A for QSFP-DD, 400G/200G, 100G dual
Page 6
Choose MU104015A for OSFP, 400G, 100G single
Page 7

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-4-1 Selecting Protocol Options.
Page 9

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-5-1 Selecting Protocol Options.
Page 10

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-3-1 Selecting Protocol Options.
Page 8

Select Protocol Select the model for choosing the measurement protocol port number, options, etc., from 1-1-1 (MU104014A) or 1-2-1 (MU104015A) Selecting Protocol Options.
Page 6, 7

Refer to 3-1 MT1040A Power Supply Option to see your new configuration requires MTT1040A-020 or not.

MT1040A-020 is not necessary

MT1040A-020 is necessary

Check your MT1040A has MT1040A-006 or not

Yes

No

Please contact sales representative

Select Optical I/F Select the model for choosing the optical module frequency and bit rate from 1-6 Selecting Optical Transceiver for Transport Module.

Page 11

Select Transport Test Options Select the model for choosing the required options from 1-7 Selecting Transport Test Option.

Page 12

Selecting Main Frame Accessories. Select the main frame optional accessories from 3-1 MT1040A Selecting Common Application Parts. Select the model for the extended hardware warranty from 3-3 MT1040A Selecting Extended Warranty Services.
Page 18

Record the purchased model and name in the configuration confirmation order sheet.

Page 30

22

Adding OTDR Module

Select Optical Fiber Select the type of optical fiber to measure Single Mode only Both Single Mode and Multimode

Single Mode only

2 Wavelength (1310/1550 nm)
Choose MU100020A Page 13

Wavelength select

3 Wavelength (1310/1550/ 1625 nm)
Choose MU100022A

Page 15

Both Single Mode and Multimode

3 Wavelength (1310/1550/ 1650 nm)
Choose MU100023A

Page 16

Choose MU100021A Page 14

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-1-1 Selecting Dynamic Range.
Page 13

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-3-1 Selecting Dynamic Range.
Page 15

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-4-1 Selecting Dynamic Range.
Page 16

Select Dynamic Range Select the model with the required test wavelength and dynamic range from 2-2-1 Selecting Dynamic Range.
Page 14

Select Connector Select the model with the required connector type from 2-1-2 Selecting Polish Type/ Connector Adapter.
Page 13

Select Connector Select the model with the required connector type from 2-3-2 Selecting Polish Type/ Connector Adapter.
Page 15

Select Connector Select the model with the required connector type from 2-4-2 Selecting Polish Type/ Connector Adapter.
Page 16

Select Connector Select the model with the required connector type from 2-2-2 Selecting Polish Type/ Connector Adapter.
Page 14

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-1-3 Selecting Visible Light Source Option.
Page 13

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-3-3 Selecting Visible Light Source Option.
Page 15

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-4-3 Selecting Visible Light Source Option.
Page 16

With/Without Visible Light Source Select the model with built-in visible light source if required from 2-2-3 Selecting Visible Light Source Option.
Page 14

Selecting OTDR Test Options Select the models with the option choices from 2-5-1 OTDR Module Conversion Connector Adapters, 2-5-2 Optical Fiber Conversion Adapters, and 2-5-3 Others.
Page 17

23

Additional Purchases
Adding New Options to Previously Purchased MT1040A
Confirm the serial numbers of the MT1040A, MU104014A/MU104015A/MU104011A and MU100010A/MU100011A.

4-1 Adding Test Protocols for Transport Module When adding options, please either specify one of the following media along with the relevant option, or Web download.

Model Z1849A Z1850A

Name DVD-ROM for Retrofit Options USB Stick for Retrofit Options

In addition, when purchasing multiple retrofit options at one time, they are all installed using the same media.

To add a new protocol option to a previously purchased MU104014A, choose the required option from the following list. The MU104014A serial number is required to make the purchase.

MU104014A Transport Technology Ethernet

Bit Rate
No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

Pass-through (10G), Channel Stat (10G) TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-XDR4 N-Port BERT eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan

ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET
Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

10G or less 2 (Dual Channel)

16G or 25G

40G or 100G

2 (Dual Channel) 1 (Single Channel) 2 (Dual Channel)

MU104014A-312 Ethernet up to 25G Dual Channel Retrofit

MU104014A-312

Ethernet up to 25G

Dual Channel Retrofit

MU104014A-320

TCP Throughput

Retrofit*2

MU104014A-313 MU104014A-314

Ethernet 40G

Ethernet 40G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-315 MU104014A-316

Ethernet 100G

Ethernet 100G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-312 Ethernet up to 25G Dual Channel Retrofit

MU104014A-313 MU104014A-314

Ethernet 40G

Ethernet 40G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-315 MU104014A-316

Ethernet 100G

Ethernet 100G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-352 OTN up to 10G
Dual Channel Retrofit
MU104014A-363 ODU Multiplexing/ Multi Stage Retrofit*3

MU104014A-353 MU104014A-354

OTN 40G

OTN 40G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-355 MU104014A-356

OTN 100G

OTN 100G

Single Channel Retrofit Dual Channel Retrofit

MU104014A-363

ODU Multiplexing/Multi Stage Retrofit*3

MU104014A-374

CPRI/OBSAI up to 25G Dual Channel Retrofit

MU104014A-392 FC up to 16G Dual Channel Retrofit

MU104014A-382

SDH/SONET up to

10G Dual Channel

Retrofit

MU104014A-384*4 STM-256/OC-768 Client Signal Retrofit

200G or 400G 1 (Single Channel) MU104014A-331
Ethernet 200G Single Channel Retrofit MU104014A-333
Ethernet 400G Single Channel Retrofit

— MT104014A-334 4×100G N Port BERT
Retrofit







1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104014A-012. 3: Requires that at least one of the following option is installed: MU104014A-052, MU104014A-053, MU104014A-054, MU104014A-055, MU104014A-056. 4: MU104014A does not have a physical interface of the option. The option is required for client signal mapped in the OTN. 24

Additional Purchases
Adding New Options to Previously Purchased MT1040A

To add a new protocol option to a previously purchased MU104015A, choose the required option from the following list. The MU104015A serial number is required to make the purchase.

MU104015A Transport Technology Ethernet

Bit Rate No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

Pass-through (10G), Channel Stat (10G) TCP Throughput Test (RFC 6349, iPerf,10G) 400GBASE-2FR4 N-Port BERT eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/ Generation, Tributary Scan
ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

10G or less 2 (Dual Channel)

16G or 25G 2 (Dual Channel)

MU104015A-312 Ethernet up to 25G Dual Channel Retrofit

MU104015A-312

Ethernet up to 25G

Dual Channel Retrofit

MU104015A-320

TCP Throughput

Retrofit*2

MU104015A-312 Ethernet up to 25G Dual Channel Retrofit

— MU104015A-352

OTN up to 10G

Dual Channel Retrofit

MU104015A-363

ODU Multiplexing/

Multi Stage Retrofit*3

MU104015A-374 CPRI/OBSAI up to 25G Dual Channel Retrofit

MU104015A-392 FC up to 16G Dual Channel Retrofit

MU104015A-382

SDH/SONET up to

10G Dual Channel

Retrofit

40G or 100G 1 (Single Channel) 2 (Dual Channel)

MU104015A-313

Ethernet 40G

Single Channel Retrofit

MU104015A-315

Ethernet 100G

Single Channel Retrofit

MU104015A-313

Ethernet 40G

Single Channel Retrofit

MU104015A-315

Ethernet 100G

Single Channel Retrofit

MU104015A-353

OTN 40G

Single Channel Retrofit

MU104015A-355

OTN 100G

Single Channel Retrofit

MU104015A-363

ODU Multiplexing/

Multi Stage Retrofit*3

MU104015A-384*4 STM-256/OC-768 Client Signal Retrofit

400G 1 (Single Channel)
— MU104015A-333
Ethernet 400G Single Channel Retrofit
— — MU104015A-335 2×200G N Port BERT Retrofit
— —
— — —


1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104015A-012. 3: Requires that at least one of the following option is installed: MU104015A-052, MU104015A-053, MU104015A-055. 4: MU104015A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.

25

Additional Purchases
Adding New Options to Previously Purchased MT1040A

To add a new protocol option to a previously purchased MU104011A, choose the required option from the following list. The MU104011A serial number is required to make the purchase.

MU104011A Transport Technology Ethernet

Bit Rate No. of Measurement Ports*1

10G or less 2 (Dual Channel)

16G or 25G 2 (Dual Channel)

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, In-band Control, Auto discovery, Reflector

MU104011A-312 Ethernet up to 25G Dual Channel Retrofit

Pass-through (10G), Channel Stat (10G)
TCP Throughput Test (RFC 6349, iPerf,10G) eCPRI/RoE (IEEE1914.3)

MU104011A-312

Ethernet up to 25G

Dual Channel Retrofit

MU104011A-320

TCP Throughput Retrofit*2

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

MU104011A-312 Ethernet up to 25G Dual Channel Retrofit

OTN

Errors/Alarms, Error Performance/Delay/APS Test, FEC Test,

MU104011A-352

O.182 Test, Overhead Editing/Capture, TCM Monitoring/

OTN up to 10G

Generation, Tributary Scan

Dual Channel Retrofit

ODU Multiplexing Addition
CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement, Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection, Framed BER Measurement, RTD Measurement, Monitoring using Passthrough
Fibre Channel Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET Two-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/ Generation, Pointer Event Generation, Tributary Scan

MU104011A-363

ODU Multiplexing/

Multi Stage Retrofit*3

MU104011A-374 CPRI/OBSAI up to 25G Dual Channel Retrofit

MU104011A-392 FC up to 16G Dual Channel Retrofit

MU104011A-382

SDH/SONET up to 10G

Dual Channel Retrofit

40G or 100G

1 (Single Channel)

2 (Dual Channel)

MU104011A-313 Ethernet 40G
Single Channel Retrofit MU104011A-315 Ethernet 100G
Single Channel Retrofit

MU104011A-314 Ethernet 40G
Dual Channel Retrofit MU104011A-316
Ethernet 100G Dual Channel Retrofit

MU104011A-313 Ethernet 40G
Single Channel Retrofit
MU104011A-315 Ethernet 100G
Single Channel Retrofit

MU104011A-314 Ethernet 40G
Dual Channel Retrofit
MU104011A-316 Ethernet 100G
Dual Channel Retrofit

MU104011A-353 OTN 40G
Single Channel Retrofit
MU104011A-355 OTN 100G
Single Channel Retrofit

MU104011A-354 OTN 40G
Dual Channel Retrofit
MU104011A-356 OTN 100G
Dual Channel Retrofit

MU104011A-363 ODU Multiplexing/Multi Stag Retrofite*3

MU104011A-384*4 STM-256/OC-768 Client Signal Retrofit

1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: Requires to MU104011A-012. 3: Requires that at least one of the following option is installed: MU104011A-052, MU104011A-053, MU104011A-054, MU104011A-055, MU104011A-056. 4: MU104011A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.

26

Additional Purchases
Adding New Options to Previously Purchased MT1040A

To add a new protocol option to a previously purchased MU100010A, choose the required option from the following list. The MU100010A serial number is required to make the purchase.

Adding MU100010A Protocol Option

Bit Rate

Transport Technology

No. of Measurement Ports*1

Ethernet

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery, Path-through, Channel Stat

TCP Throughput Test (RFC 6349, iPerf)

eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

OTN2,
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition
3 ODU Flex Addition*4 CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET, PDH/DSn PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan

Less than 5G 2 (Dual Channel)

From 6G to 10G

1 (Single Channel)

2 (Dual Channel)

MU100010A-301
Up to 2.7G Dual Channel Retrofit

MU100010A-311
Ethernet 10G Single Channel Retrofit

MU100010A-312
Ethernet 10G Dual Channel Retrofit

MU100010A-320 TCP Throughput Retrofit

MU100010A-301
Up to 2.7G Dual Channel Retrofit

MU100010A-311
Ethernet 10G Single Channel Retrofit

MU100010A-312
Ethernet 10G Dual Channel Retrofit

MU100010A-301
Up to 2.7G Dual Channel Retrofit

MU100010A-351
OTN 10G Single Channel Retrofit

MU100010A-352
OTN 10G Dual Channel Retrofit

MU100010A-361 ODU Multiplexing Retrofit

MU100010A-362 ODU Flex Retrofit

MU100010A-371
CPRI/OBSAI Up to 5G Dual Channel Retrofit

MU100010A-372
CPRI/OBSAI 6G to 10G Single Channel Retrofit

MU100010A-373
CPRI/OBSAI 6G to 10G Dual Channel Retrofit

MU100010A-302
FC 1G 2G 4G Dual Channel Retrofit

MU100010A-391
FC 8G 10G Single Channel Retrofit

MU100010A-301
Up to 2.7G Dual Channel Retrofit

MU100010A-381
STM-64 OC-192 Single Channel Retrofit

MU100010A-392 FC 8G 10G Dual Channel
Retrofit
MU100010A-382 STM-64 OC-192
Dual Channel Retrofit

1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
2: When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the
MU100010A-351/352 (for physical port) and the MU100010A-381/382 (for client signal) are required.
3: When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel.
4: When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.

27

Additional Purchases
Adding New Options to Previously Purchased MT1040A

To add a new protocol option to a previously purchased MU100011A, choose the required option from the following list. The MU100011A serial number is required to make the purchase.

Adding MU100011A Protocol Option Transport Technology Ethernet

Bit Rate
No. of Measurement Ports*1

IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control, Auto discovery

Pass-through, Channel Stat TCP Throughput Test (RFC 6349, iPerf) SyncE Wander
Measurement using 100GBASE-SR
eCPRI/RoE (IEEE1914.3)

IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM

Measurement using 100GBASE-SR
OTN2, 3
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test, Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
ODU Multiplexing Addition2, 4 ODU Flex Addition2, 5 CPRI/OBSAI CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement, Monitoring using Passthrough Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER, Line Alarm/Error Monitoring
SDH/SONET PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms, Error Performance/Delay/APS Test, Header Monitoring/Generation, Pointer Event Generation, Tributary Scan

Up to 10G 1 (Single Channel) 2 (Dual Channel)

Higher than 10G

1 (Single Channel)

2 (Dual Channel)

MU100011A-317*8

Ethernet 25G

Single Channel Retrofit

MU100011A-301 MU100011A-303

MU100011A-313*9 Ethernet 40G

Up to 10G

Up to 10G

Single Channel Retrofit

Single Channel Retrofit Dual Channel Retrofit

MU100011A-315*9

Ethernet 100G

Single Channel Retrofit

MU100011A-320 TCP Throughput

MU100011A-021*10 SyncE Wander

MU100011A-323*8

RS-FEC for 100GBASE-SR4

Retrofit MU100011A-315*9

Ethernet 100G

Single Channel Retrofit

MU100011A-301 Up to 10G
Single Channel Retrofit

MU100011A-303 Up to 10G
Dual Channel Retrofit

MU100011A-3178 Ethernet 25G
Single Channel Retrofit
MU100011A-313
9 Ethernet 40G
Single Channel Retrofit
MU100011A-3159 Ethernet 100G
Single Channel Retrofit
MU100011A-323
8 RS-FEC for 100GBASE-SR4
Retrofit
MU100011A-315*9 Ethernet 100G
Single Channel Retrofit

MU100011A-3757, 8 eCPRI/RoE 25G Dual Channel Retrofit — —

MU100011A-353

MU100011A-301

MU100011A-303

OTN 40G Single Channel Retrofit

Up to 10G

Up to 10G

Single Channel Retrofit Dual Channel Retrofit

MU100011A-355 OTN 100G

Single Channel Retrofit

MU100011A-363 ODU Multiplexing/Multi Stage Retrofit

MU100011A-362 ODU Flex Retrofit

MU100011A-371 MU100011A-372 CPRI/OBSAI Up to 10G CPRI/OBSAI Up to 10G Single Channel Retrofit Dual Channel Retrofit

MU100011A-373 CPRI 12/25G
Single Channel Retrofit

MU100011A-374 CPRI 12/25G
Dual Channel Retrofit

MU100011A-304 MU100011A-305

MU100011A-391

Up to 10G FC

Up to 10G FC

FC 16G

Single Channel Retrofit Dual Channel Retrofit Single Channel Retrofit

MU100011A-301 MU100011A-303

MU100011A-383*6

Up to 10G

Up to 10G

STM-256/OC-768

Single Channel Retrofit Dual Channel Retrofit

Client Signal Retrofit

*1:

The channel is not related to the physical port For a dual channel setup, the two different ports

position. The user can freely choose either of the two can operate simultaneously with different bit rate of the

physical ports assigned same single protocol.

to

the

option

via

software.

**23::

Please see the datasheet for supported OTN mapping. When using the OTN function, the channel can be used For example, when mapping STM-256/OC-768 to OTU4,

as client signal mapped to both the MU100011A-355

OTN. (for physical

port)

and

the

MU100011A-383

(for

client

signal)

are

required.

*4:

When the ODU Multiplexing/Multistage option is This one option supports both single channel and

installed, OTN dual channel.

multistage

mapping

measurements

are

supported.

**567891:::::0TTOFF: EEhh4pCC0iestGiciMomsanaUananlsp1wdbup0eap10iynp0s0sgwo01OrG1ifttuAFscanFherhc.eeCtadiPsonROonnItoN/isRs/SuobOTpEaFMpsFpeo-.rd2rot5teo6odn/c .OothlCet-e7Os6tD8s UoPFnHlleYyx.insttaenrfdaacred;

for transmissions it can be used for

over OTN

OTN networks client signals.

and

supports

client

signals

of

any

speed.

28

Additional Purchases
Adding New Options to Previously Purchased MT1040A

4-2 Adding Main Frame Options for Transport Function

The MT1040A serial number is required at purchase.

Model MT1040A-303 MT1040A-320
MT1040-311

Name Connectivity for WLAN/Bluetooth Retrofit Activate for 400G Dual/100G Quad retrofit
Site Over Remote Access Connect retrofit

Notes
WLAN/Bluetooth options (can be used in approved countries, including N. America, Japan, EU; see Anritsu web site for latest list of countries)
In mounting two transport modules, this option is required. This option includes AC Adapter G0419A. Please refer to 3.1 Power supply option.
– When the MT1040A already has MT1040A-006, please order MT1040A-320. – When the MT1040A does not have MT1040A-006, please contact to sales representative.
This option enables remote control of the MT1040A using the Site Over Remote Access MX109020A software. We recommend using in conjunction with the WLAN/Bluetooth option MT1040A-003/303. A Wi-Fi dongle can be used in countries and regions where WLAN is not supported. For a list of supported Wi-Fi dongles, please contact us.

When adding MT1040A-303 and/or MT1040A-311, please either specify one of the following media along with the relevant option, or Web download.

Model Z1849A Z1850A

Name DVD-ROM for Retrofit Options USB Stick for Retrofit Options

4-3 Adding Transport Module
When adding Transport Module to a previously purchased MT1040A, use the same procedure as for Transport Module described on pages 6 thru 12, 18 thru 21.

4-4 Adding OTDR Module When adding the OTDR Module to a previously purchased MT1040A, use the same procedure as for OTDR Module described on pages 13 thru 21.

4-5 Adding MX109020A Option Requires MX109020A serial number at purchase.

Model MX109020A-TL001 MX109020A-301 MX109020A-302 MX109020A-303

Name Site Over Remote Access 1 Year License Site Over Remote Access 8 Units Site Over Remote Access Unlimited Units Centralized Data Management

Notes Extends MX109020A usage period by 1 year Extends number of instruments simultaneously controlled by MX109020A to 8 units Extends number of instruments simultaneously controlled by MX109020A to 100 units Supports upload of measurement report from MT1040A to cloud storage

29

Network Master Pro MT1040A
Configuration Examples

400G Core/Metro Installation The most simple configuration to install 400G network.

Model

Name

Q’ty

MT1040A

Network Master Pro

1

MU104014A

400G (QSFP-DD) Multirate Module

1

MU104014A-033 Ethernet 400G Single Channel

1

G0404A

QSFP-DD 400GBASE-LR4

1

Up to 400G Ethernet Installation and Maintenance
Multirate Ethernet configuration to install or maintein Carrier class Ethernet network.

Model

Name

Q’ty

MT1040A

Network Master Pro

1

MU104014A

400G (QSFP-DD) Multirate Module

1

MU104014A-012 Ethernet up to 25G Dual Channel

1

MU104014A-014 Ethernet 40G Dual Channel

1

MU104014A-016 Ethernet 100G Dual Channel

1

MU104014A-031 Ethernet 200G Single Channel

1

MU104014A-033 Ethernet 400G Single Channel

1

G0322A

1G/2G/4G FC 1310 nm SFP

2

G0315A

10G LR/LW 1310 nm SFP+

2

G0389A

25G LR 1310nm SFP28

2

G0334A

40G LR4 1310 nm QSFP+

2

G0364A

100G LR4 1310 nm QSFP28

2

G0421A

QSFP56 200GBASE-LR4

1

G0404A

QSFP-DD 400GBASE-LR4

1

400G Ethernet Dual Port for System Verification
The detail verification of 400G Ethernet system such as bi-directional testing.

Model

Name

Q’ty

MT1040A

Network Master Pro

1

MT1040A-020

Activate for 400G Dual/100G Quad Option

1

MU104014A

400G (QSFP-DD) Multirate Module

2

MU104014A-033 Ethernet 400G Single Channel

2

G0404A

QSFP-DD 400GBASE-LR4

2

Up to 400G Datacom Network Installation and Maintenance
Multirate and multiprotocol configuration to install or maintein datacom network.

Model

Name

Q’ty

MT1040A

Network Master Pro

1

MU104014A

400G (QSFP-DD) Multirate Module

1

MU104014A-012 Ethernet up to 25G Dual Channel

1

MU104014A-014 Ethernet 40G Dual Channel

1

MU104014A-016 Ethernet 100G Dual Channel

1

MU104014A-031 Ethernet 200G Single Channel

1

MU104014A-033 Ethernet 400G Single Channel

1

MU104014A-020 TCP Throughput

1

MU104014A-092 FC up to 16G Dual Channel

1

G0322A

1G/2G/4G FC 1310 nm SFP

2

G0315A

10G LR/LW 1310 nm SFP+

2

G0364A

100G LR4 1310 nm QSFP28

2

G0421A

QSFP56 200GBASE-LR4

1

G0404A

QSFP-DD 400GBASE-LR4

1

Ethernet Service and Optical Fiber Commissioning Transport and OTDR in one box with upgradability to 400G.

Model

Name

Q’ty

MT1040A

Network Master Pro

1

MU104014A

400G (QSFP-DD) Multirate Module

1

MU104014A-012 Ethernet up to 25G Dual Channel

1

MU104014A-016 Ethernet 100G Dual Channel

1

MU100022A

OTDR Module 1310/1550/1625 nm SMF

1

MU100022A-022 High-Performance Dynamic Range

1

MU100022A-010 UPC Polish

1

MU100022A-037 FC Connector

1

MU100022A-002 Visual Fault Locator

1

G0322A

1G/2G/4G FC 1310 nm SFP

2

G0315A

10G LR/LW 1310 nm SFP+

2

G0364A

100G LR4 1310 nm QSFP28

2

30

Network Master Pro MT1040A
Order Sheet

When recording different MT1040A configurations on one order sheet, describe each MT1040A configuration on one line with the accompanying options under the relevant line.

Model

Name

Quantity

31

Network Master Pro MT1040A
Method for Adding Measurement Modules
Preparation 1: Version up the software for MT1040A Install the latest software in the MT1040A. This software can be obtained from the Anritsu web site.
Preparation 2: Remove the battery pack from Mainframe 1) Disconnect the AC cable. 2) Use screw driver or Coin and remove the battery lid from MT1040A.

Attaching the Transport (MU10001xA) or OTDR (MU10002xA) Module 1) Remove four screws of former module and replace to the next screws.
Choose the bolts matching the added module. Use the B0740A for transport (MU10001xA) or OTDR module.
For Adding MU10401xA Module (B0741A)
For Adding MU10001xA, MU10002xA (B0740A)
Standard Part (B0731A)

  1. Remove the battery pack.

  2. Align the OTDR module horizontally with the MT1040A as shown below. Align the connectors on the left side.

Preparation 3: Replacing the connected modules 1) Place the instrument on its front on a plain surface.
Loosen the screws (shown by the blue circle) on rear side of the connected module.
2) After loosing the four screws, lift up the connected module with holding both sides. If you cannot lift up, loosen the four screws again. You can see the panel as below.

MT1040A Main Unit Side

Measurement Modules Side

  1. Install the OTDR module in the correct MT1040A slot as shown below.

OTDR Module MU10002xA

Transport Module MU10401xA

MT1040A Mainframe

Side View after Assembling Modules Note: Align the four edges when installing the option; the module connector is
easily damaged by misalignment. 4) Secure the module using the B0740A part chosen in step 1.
After installing the module as shown in the figure on the right, check that there is no gap between the modules.

MT1040A Main Unit Back Panel
32

After attaching the modules 1) After attaching the modules,
connect the AC cable or install the battery packs.
2) Turn on the MT1040A. Please check whether a new module is recognized at the system information.

Network Master Pro MT1040A
Method for Adding Measurement Modules
Adding Transport Module (MU10401xA) 1) Confirm that the MT1040A-020 option is installed in the MT1040A
main unit. 2) Choose the bolts matching the added module.
Use the B0741A for the MU10401xA module
For Adding MU10401xA Module (B0741A)
For Adding MU10001xA, MU10002xA (B0740A)
Standard Part (B0731A)

After attaching the modules

  1. Connect the G0419A standard accessory of the MT1040A-020 option to the MT1040A. The G0418A will not start. Additionally, battery operation is not possible when two transport modules are installed.

  2. Turn on the MT1040A. Please check whether a new module is recognized at the system information.

  3. Align the transport module horizontally with the MT1040A as shown below.
    Align the connectors on the left side.

MT1040A Main Unit Side

Measurement Modules Side

  1. Install the transport module in the correct MT1040A slot as shown below.

400G (QSFP-DD) Module MU104014A
400G (QSFP-DD) Module MU104014A
MT1040A Mainframe

Side View after Assembling Modules
Note: Align the four edges when installing the option; the module connector is easily damaged by misalignment.
5) Secure the module using the B0741A part chosen in step 2. After installing the module as shown in the figure on the right, check that there is no gap between the modules.

33

Note
34

Note
35

Specifications are subject to change without notice.

· United States Anritsu Americas Sales Company
450 Century Parkway, Suite 190, Allen, TX 75013 U.S.A. Phone: +1-800-Anritsu (1-800-267-4878)
· Canada Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006
· Brazil Anritsu Eletronica Ltda.
Praça Amadeu Amaral, 27 – 1 Andar 01327-010 – Bela Vista – Sao Paulo – SP, Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940
· Mexico Anritsu Company, S.A. de C.V.
Blvd Miguel de Cervantes Saavedra #169 Piso 1, Col. Granada Mexico, Ciudad de Mexico, 11520, MEXICO Phone: +52-55-4169-7104
· United Kingdom Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303
· France Anritsu S.A.
12 avenue du Québec, Immeuble Goyave, 91140 VILLEBON SUR YVETTE, France Phone: +33-1-60-92-15-50
· Germany Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1, 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
· Italy Anritsu S.r.l.
Spaces Eur Arte, Viale dell’Arte 25, 00144 Roma, Italy Phone: +39-6-509-9711

· Sweden Anritsu AB
Kistagången 20 B, 2 tr, 164 40 Kista, Sweden Phone: +46-8-534-707-00
· Finland Anritsu AB
Technopolis Aviapolis, Teknobulevardi 3-5 (D208.5.), FI-01530 Vantaa, Finland Phone: +358-20-741-8100
· Denmark Anritsu A/S
c/o Regus Winghouse, Ørestads Boulevard 73, 4th floor, 2300 Copenhagen S, Denmark Phone: +45-7211-2200
· Russia Anritsu EMEA Ltd. Representation Office in Russia
Tverskaya str. 16/2, bld. 1, 7th floor., Moscow, 125009, Russia Phone: +7-495-363-1694 Fax: +7-495-935-8962
· Spain Anritsu EMEA Ltd. Representation Office in Spain
Paseo de la Castellana, 141. Planta 5, Edificio Cuzco IV 28046, Madrid, Spain Phone: +34-91-572-6761
· Austria Anritsu EMEA GmbH
Am Belvedere 10, A-1100 Vienna, Austria Phone: +43-(0)1-717-28-710
· United Arab Emirates Anritsu EMEA Ltd. Anritsu A/S
Office No. 164, Building 17, Dubai Internet City P. O. Box ­ 501901, Dubai, United Arab Emirates Phone: +971-4-3758479
· India Anritsu India Private Limited
6th Floor, Indiqube ETA, No.38/4, Adjacent to EMC2, Doddanekundi, Outer Ring Road, Bengaluru ­ 560048, India Phone: +91-80-6728-1300 Fax: +91-80-6728-1301

· Singapore Anritsu Pte. Ltd.
11 Chang Charn Road, #04-01, Shriro House, Singapore 159640
Phone: +65-6282-2400 Fax: +65-6282-2533

· Vietnam Anritsu Company Limited
16th Floor, Peakview Tower, 36 Hoang Cau Street, O Cho Dua Ward, Dong Da District, Hanoi, Vietnam
Phone: +84-24-3201-2730
· P.R. China (Shanghai) Anritsu (China) Co., Ltd.
Room 2701-2705, Tower A, New Caohejing International Business Center No. 391 Gui Ping Road Shanghai, 200233, P.R. China
Phone: +86-21-6237-0898 Fax: +86-21-6237-0899

· P.R. China (Hong Kong) Anritsu Company Ltd.
Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong, P.R. China
Phone: +852-2301-4980 Fax: +852-2301-3545

· Japan Anritsu Corporation
8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan
Phone: +81-46-296-6509 Fax: +81-46-225-8352

· Korea Anritsu Corporation, Ltd.
5FL, 235 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13494 Korea
Phone: +82-31-696-7750 Fax: +82-31-696-7751

· Australia Anritsu Pty. Ltd.
Unit 20, 21-35 Ricketts Road, Mount Waverley, Victoria 3149, Australia
Phone: +61-3-9558-8177 Fax: +61-3-9558-8255

· Taiwan Anritsu Company Inc.
7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816 Fax: +886-2-8751-1817

2106

Printed in Japan 07/FEB/2022 ddcm/CDT Catalog No. MT1040A_ConfigGuide-E-A-1-(2.00)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals