Rheem RP1636AJ2NA Heat Pump Home Appliance User Guide
- June 13, 2024
- Rheem
Table of Contents
Rheem RP1636AJ2NA Heat Pump Home Appliance
Product Information
The RP16 is a split system air conditioner and heat pump manufactured by Rheem. It is designed to provide optimal performance when properly sized and installed. The unit must be matched with appropriate coil components to meet Energy Star standards. For more details, consult your contractor or visit www.energystar.gov.
Features and Benefits
The RP16 comes with a range of standard features that ensure efficient and
reliable operation. For a detailed list of features and benefits, please refer
to the user manual.
Available SKUs
The RP16 is available in various models with different capacities and
specifications. The available models include:
- RP1636AJ2NA – 18,000 BTU/HR (5.28 kW)
- RP1660AJ2NA – 24,000 BTU/HR (7.03 kW)
- RP1660AJ2NANOM – 30,000 BTU/HR (8.79 kW)
- RP1648AJ2NA – 36,000 BTU/HR (10.55 kW)
- RP1624AJ2NA – 42,000 BTU/HR (12.31 kW)
- RP1648AJ2NANOM – 48,000 BTU/HR (14.07 kW)
- RP1624AJ2NANOM – 60,000 BTU/HR (17.58 kW)
- RP1636AJ2NANOM – 18,000 BTU/HR (5.28 kW)
Each model is available in different voltage and phase options. Consult the user manual or contact your contractor for the specific model that suits your requirements.
General Data
The RP16 has specific physical and electrical data that can be found in the
user manual. For more details, please refer to the manual or visit the
provided link for the complete specifications.
Weighted Sound Power
The RP16 has a weighted sound power level measured in decibels (dBA). The
specific sound power levels for each unit size and voltage can be found in the
user manual. Please note that the sound power level is tested in accordance
with AHRI Standard 270-08.
Product Usage Instructions
To ensure optimal performance and efficiency, follow these instructions for using the RP16:
- Proper Sizing and Installation: It is crucial to properly size and install the RP16 unit. Consult a qualified contractor to determine the appropriate size and ensure correct installation.
- Matching Coil Components: The RP16 must be matched with compatible coil components to meet Energy Star standards. Consult your contractor or refer to the user manual for details on compatible coil components.
- Control Wiring: Follow the control wiring diagram provided in the user manual to correctly connect the control wires of the RP16 unit.
- Refrigerant Line Size: Refer to the refrigerant line size information in the user manual to determine the appropriate size for the refrigerant lines connecting the RP16 unit.
- Clearances: Maintain proper clearances around the RP16 unit as specified in the user manual. This ensures proper airflow and accessibility for maintenance.
- Accessories: Optional accessories such as a compressor crankcase heater, compressor hard start kit, compressor sound cover, high pressure control, low ambient control, and low pressure control can be used with the RP16. Refer to the accessories section in the user manual for more information.
- Maintenance: Regularly clean and inspect the RP16 unit as outlined in the user manual. This includes cleaning the condenser coils, checking refrigerant levels, and inspecting electrical connections.
- Warranty: The RP16 comes with a limited warranty. Refer to the warranty section in the user manual for details on coverage and terms.
For any further assistance or specific questions regarding the usage of the RP16, please consult the user manual or contact Rheem customer support.
Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.
Standard Feature Table
Standard Features
Standard Features Data Mismatches found. Please go to
https://my.rheem.com/static/private/POC/SpecSheets/AC/heatpumps.html?ssid=3eab55d0-fda4
-412a-
bb70-1277f744dcb0&id=d5738741-8e14-4b38-a571-7fd152541abe
Features and Benefits
Air Conditioners
R| A| 16| 24| A| J| 1|
N| A|
Brand| Product Category| SEER| Capacity BTU/HR| Major
Series| Voltage| Type| Contols| Minor Series**|
Option Code
Rheem| A-Air Conditioners| 16-16 SEER| 18-18,000[5.28 kW]| A-1st Design|
J-1ph, 208-230/60| 1-Single Stage| N-NonCommunicating| A-1st Design| N/A
| | | 24-24,000[7.03 kW]| B-2nd Design| C-3ph, 208-230/60| | | B-2nd
Design|
| | | 30-30,000[8.79 kW]| | | | | |
| | | 36-36,000[10.55 kW]| | | | | |
| | | 42-42,000[12.31 kW]| | | | | |
| | | 48-48,000[14.07]| | | | | |
| | | 60-60,000[17.58 kW]| | | | | |
Available SKUs
Available Models| Description
RP1636AJ2NA| RP1636AJ2NA 16 SEER CUBE HP
RP1660AJ2NA| RP1660AJ2NA 16 SEER CUBE HP
RP1660AJ2NANOM| RP1660AJ2NANOM EXPORT R-410 MEXICO NOM
RP1648AJ2NA| RP1648AJ2NA 16 SEER CUBE HP
RP1624AJ2NA| RP1624AJ2NA 16 SEER CUBE HP
RP1648AJ2NANOM| RP1648AJ2NANOM EXPORT R-410 MEXICO NOM
RP1624AJ2NANOM| RP1624AJ2NANOM EXPORT R-410 MEXICO NOM
RP1636AJ2NANOM| RP1636AJ2NANOM EXPORT R-410 MEXICO NOM
General Data
Physical Data Mismatches found. Please go to
https://my.rheem.com/static/private/POC/SpecSheets/AC/heatpumps.html?ssid=3eab55d0-fda4
-412a-
bb70-1277f744dcb0&id=d5738741-8e14-4b38-a571-7fd152541abe
Electrical Data
Model No.| RP1624AJ| RP1636AJ| RP1648AJ| RP1660AJ
Line Voltage Data (V olts-Phase-Hz)| 208/230-1-60| 208/230-1-60|
208/230-1-60| 208/230-1-60
MaximumOvercurrentProtectionAmps1| 30| 40| 50| 60
MinimumCircuitAmpacity1| 20| 25| 31| 38
Compressor
CompressorRatedLoadAmps1| 0| 0| 0| 0
CompressorLockedRotorAmps1| 0| 0| 0| 0
Condensor Fan Motor
CondenserFanMotorFullLoadAmps1| 2.8| 2.8| 1.4| 1.4
CondenserFanMotorLockedRotorAmps1| 0| 0| 0| 0
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of fuse.
- Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Accessories
RP1624A
Accessory Type| Part Number
RP1636A
Accessory Type| Part Number
RP1648A
Accessory Type| Part Number
RP1660A
Accessory Type| Part Number
Compressor crankcase heater| 44-17402-44
Compressor hard start kit| SK-A1
Compressor sound cover| 68-23427-26
High pressure control| Factory Standard
Low ambient control| RXAD-A08
Low pressure control| Factory Standard
Weighted Sound Power Level (dBA)
Unit Size – Voltage, Series| Standard
Rating (dBa)
| Typical Octave Band Spectrum (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
RP1624A| 71| 0| 0| 0| 0| 0| 0| 0
RP1636A| 76| 0| 0| 0| 0| 0| 0| 0
RP1648A| 74| 0| 0| 0| 0| 0| 0| 0
RP1660A| 75| 0| 0| 0| 0| 0| 0| 0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
Unit Dimensions Mismatches found. Please go to
https://my.rheem.com/static/private/POC/SpecSheets/AC/heatpumps.html?ssid=3eab55d0-fda4
-412a-
bb70-1277f744dcb0&id=d5738741-8e14-4b38-a571-7fd152541abe
No Unit Dimensions Image Found.
Control Wiring
No Control Wiring Image Found.
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
- Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C)
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, unit should be level in all horizontal planes.
- Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory–supplied filter drier must be installed.
Refrigerant Line Size Information
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable
Liquid Line Size
| Allowable
Suction Line Size
| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150|
151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
1.5 Ton See Note 3| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98|
43/.98| 24/.97| 5/.97| NR| NR| NR| NR
5/16″| 5/8″| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97|
88/.97| 83/.96| 78/.96| 73/.95| 68/.94
3/8″| 5-8″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97|
100/.97| 100/.96| 100/.96| 100/.95| 100/.94
1/4″| 3/4″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98| 43/.98| 24/.97|
5/.97| NR| NR| NR| NR
5/16″| 3/4″| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97|
88/.97| 83/.99| 78/.98| 73/.98| 68/.98
3/8″| 3/4″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97|
100/.97| 100/.99| 100/.98| 100/.98| 100/.98
2 Ton| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.98| 21/.97| NR| NR| NR| NR|
NR| NR| NR
5/16″| 5/8″| 243| 213| 193| 175| 25/.99| 50/.98| 75/.97| 87/.96| 77/.95|
69/.94| 61/.93| 53/.92| 45/.91| 37/.90
3/8″| 5/8″| 162| 142| 128| 117| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95|
100/.94| 98/.93| 95/.92| 92/.91| 89/.90
1/4″| 3/8″| N/A| N/A| N/A| N/A| 25/1.00| 50/1.00| 21/.99| NR| NR| NR| NR| NR|
NR| NR
5/16″| 3/4″| 243| 213| 193| 175| 25/1.00| 50/1.00| 75/.99| 87/.99| 77/.98|
69/.98| 61/.98| 53/.97| 45/.97| 37/.96
3/8″| 3/4″| 162| 142| 128| 117| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.98|
100/.98| 98/.98| 95/.97| 93/.97| 37/.96
2.5 Ton| 5/16″| 5/8″| N/A| N/A| 133| 110| 25/.99| 50/.98| 75/.96| 70/.94|
59/.93| 48/.91| 36/.90| NR| NR| NR
3/8″| 5/8″| 142| 117| 88| 73| 25/.99| 50/.98| 75/.96| 100/.94| 98/.93| 94/.91|
90/.90| NR| NR| NR
5/16″| 3/4″| 213| 175| 133| 110| 25/1.00| 50/.99| 75/.99| 70/.98| 59/.98|
48/.97| 36/.96| 25/.96| 13/.95| NR
3/8″| 3/4″| 142| 117| 88| 73| 25/1.00| 50/.99| 75/.99| 100/.98| 98/.98|
94/.97| 90/.96| 86/.96| 82/.95| 78/.95
3 Ton| 5/16″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.97| 66/.94| 49/.92|
32/.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 108| 85| 90| 82| 25/.99| 50/.97| 75/.94| 95/.92| 89/.90| NR| NR|
NR| NR| NR
5/16″| 3/4″| N/A| 128| 135| 123| 25/1.0| 50/.99| 66/.98| 49/.98| 32/.97|
15/.96| NR| NR| NR| NR
3/8″| 3/4″| 108| 85| 90| 82| 25/1.00| 50/.99| 75/.99| 95/.98| 89/.97| 84/.96|
78/.95| 72/.92| 67/.93| 61/.93
1/2″| 3/4″| 54| 43| 45| 41| 25/1.00| 50/.99| 75/.98| 100/.98| 100/.97|
100/.96| 100/.95| 100/.92| 100/.93| 100/.93
5/16″| 7/8″| N/A| 128| 135| 123| 25/1.00| 50/1.00| 66/1.00| 49/.99| 32/.99|
15/.99| NR| NR| NR| NR
3/8″| 7/8″| 108| 85| 90| 82| 25/1.00| 50/1.00| 75/1.00| 95/.99| 89/.99|
84/.99| 78/.98| 72/.98| 67/.98| 61/.97
1/2″| 7/8″| 54| 43| 45| 41| 25/1.00| 50/1.00| 75/1.00| 100/.99| 100/.99|
100/.99| 100/.98| 100/.98| 100/.98| 100/.97
3.5 Ton| 3/8″| 3/4″| 150| 123| 102| 75| 25/.99| 50/.98| 75/.97| 88/.96|
80/.95| 72/.94| 65/.92| 57/.91| 49/.90| NR
1/2″| 3/4″| 75| 62| 51| 38| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95| 100/.94|
100/.92| 100/.91| 100/.90| NR
3/8″| 7/8″| 150| 123| 102| 75| 25/1.00| 50/1.00| 75/.99| 88/.99| 80/.99|
72/.98| 65/.97| 57/.97| 49/.96| 42/.96
1/2″| 7/8″| 75| 62| 51| 38| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.99|
100/.98| 100/.97| 100/.97| 100/.96| 100/.96
Notes:**
1. Do not exceed 200 ft linear line length.
2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Unit Size| Allowable Liquid Line Size| Allowable
Suction Line Size
| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
---|---|---|---|---
< 25| 26-50| 51-75| 76-100| 101-125| 126-150|
151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 3/8″| 3/4″| 148| 110| N/A| 35| 25/.99| 50/.98| 70/.96| 77/.95| 67/.93|
57/.92| 46/.91| NR| NR| NR
1/2″| 3/4″| 74| 55| N/A| 18| 25/.99| 50/.98| 75/.96| 100/.95| 100/.93|
100/.92| 100/.91| NR| NR| NR
3/8″| 7/8″| 148| 110| N/A| 35| 25/1.00| 50/.99| 75/.99| 77/.98| 67/.97|
57/.97| 46/.96| 36/.96| 26/.95| 15/.95
1/2″| 7/8″| 74| 55| N/A| 18| 25/1.00| 50/.99| 75/.99| 100/.98| 100/.97|
100/.97| 100/.96| 100/.96| 99/.95| 97/.95
5 Ton| 3/8″| 3/4″| 78| 55| N/A| 0| 25/.99| 50/.97| 75/.94| 61/.92| 46/.90| NR|
NR| NR| NR| NR
1/2″| 3/4″| 39| 28| N/A| 0| 25/.99| 50/.97| 75/.94| 100/.92| 100/.90| NR| NR|
NR| NR| NR
3/8″| 7/8″| 78| 55| N/A| 0| 25/1.00| 50/.99| 75/.98| 61/.97| 46/.96| 32/.95|
18/.94| NR| NR| NR
1/2″| 7/8″| 93| 28| N/A| 0| 25/1.00| 50/.99| 75/.98| 100/.97| 100/.96|
100/.95| 18/.94| NR| NR| NR
3/8″| 1-1/8″| 78| 55| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 61/1.00| 46/1.00|
32/.99| 18/.99| NR| NR| NR
1/2″| 1-1/8″| 39| 28| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 100/1.00| 100/1.00|
100/.99| 97/.99| 95/.99| 92/.99| 89/.98
Unit Size| Allowable Liquid**
Line Size mm [in.]
| Allowable Suction Line Size mm [in.]| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
---|---|---|---|---
< 8| 8-15| 16-23| 24-30| 31-38| 39-46|
47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**
5.3 kW [1.5
ton] **See Note 3
| 6.35[1/4]| 9.53[5/8]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98|
7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98|
28/.97| 27/.97| 25/.96| 24/.96| 22/.95| 21/.94
9.53[3/8]| 15.88[5/8]| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98| 30/.97|
30/.97| 30/.96| 30/.96| 30/.95| 30/.94
6.35[1/4]| 19.05[3/4]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98|
7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98|
28/.97| 27/.97| 25/.99| 24/.98| 22/.98| 21/.98
9.53[3/8]| 19.05[3/4]**| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98|
30/.97| 30/.97| 30/.99| 30/.98| 30/.98| 30/.98
7.0 kW [2 Ton]| 6.35[1/4]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.98|
6/.97| NR| NR| NR| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| 74| 65| 59| 53| 8/.99| 15/.98| 23/.97| 27/.96| 23/.95|
21/.94| 19/.93| 16/.92| 14/.91| 11/.90
9.53[3/8]| 15.88[[5/8]| 49| 43| 39| 36| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95|
30/.94| 30/.93| 29/.92| 28/.91| 27/.90
6.35[1/4]| 19.05[3/8]| N/A| N/A| N/A| N/A| 8/1.00| 15/1.00| 6/.99| NR| NR| NR|
NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 74| 65| 59| 53| 8/1.00| 15/1.00| 23/.99| 27/.99|
23/.98| 21/.98| 19/.98| 16/.97| 14/.97| 11/.96
9.53[3/8]| 19.05[3/4]| 49| 43| 39| 36| 8/1.00| 151/1.00| 23/.99| 30/.99|
30/.98| 30/.98| 30/.98| 29/.97| 18/.97| 27/.96
8.6 kW [2.5
Ton]
| 7.94[5/16]| 15.88[5/8]| N/A| N/A| 40| 34| 8/.99| 15/.98| 23/.96| 21/.94|
18/.93| 15/.91| 11/.90| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 43| 36| 27| 22| 8/.99| 15/.98| 23/.96| 30/.94| 30/.93|
29/.91| 27/.90| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 65| 53| 40| 334| 8/1.00| 15/.99| 23/.99| 21/.98|
18/.98| 15/.97| 11/.96| 8/.96| 4/.95| NR
9.53[3/8]| 19.05[3/4]| 43| 36| 27| 22| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.98|
29/.97| 27/.96| 26/.96| 25/.95| 24/.95
10.6 kW [3 Ton]| 7.94[5/16]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.97|
20/.94| 15/.92| 10/.90| NR| NR| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 33| 26| 27| 25| 8/.99| 15/.97| 23/.94| 29/.92| 27/.90|
NR| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| N/A| 39| 41| 37| 8/1.0| 15/.99| 20/.98| 15/.98|
10/.97| 5/.96| NR| NR| NR| NR
9.53[3/8]| 19.05[3/4]| 33| 26| 27| 25| 8/1.00| 15/.99| 23/.99| 29/.98| 27/.97|
26/.96| 24/.95| 22/.92| 20/.93| 19/.93
12.70[1/2]| 19.05[3/4]| 17| 13| 14| 12| 8/1.00| 15/.99| 23/.98| 30/.98|
30/.97| 30/.96| 30/.95| 100/.92| 30/.93| 30/.93
7.94[5/16]| 22.23[7/8]| N/A| 39| 41| 37| 8/1.00| 15/1.00| 20/1.00| 15/.99|
10/.99| 5/.99| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 33| 26| 27| 25| 8/1.00| 15/1.00| 23/1.00| 29/.99|
27/.99| 26/.99| 24/.98| 22/.98| 20/.98| 19/.97
12.70[1/2]| 22.23[7/8]| 17| 13| 14| 12| 8/1.00| 15/1.00| 23/1.00| 30/.99|
30/.99| 30/.99| 30/.98| 30/.98| 30/.98| 30/.97
12.3 kW [3.5 Ton]| 9.53[3/8]| 19.05[3/4]| 46| 36| 31| 23| 8/.99| 15/.98|
23/.97| 27/.96| 24/.95| 22/.94| 20/.92| 17/.91| 15/.90| NR
12.70[1/2]| 19.05[3/4]| 23| 19| 15| 11| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95|
30/.94| 30/.92| 30/.91| 30/.90| NR
9.53[3/8]| 22.23[7/8]| 46| 38| 31| 23| 8/1.00| 15/1.00| 23/.99| 27/.99|
24/.99| 22/.98| 20/.97| 17/.97| 15/.96| 13/.96
12.70[1/2]| 22.23[7/8]| 23| 19| 15| 11| 8/1.00| 15/1.00| 23/.99| 30/.99|
30/.99| 30/.98| 30/.97| 30/.97| 30/.96| 30/.96
Notes:
1. Do not exceed 200 ft linear line length.
2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable Liquid Line Size| Allowable Suction Line Size| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46|
47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 9.53[3/8]| 19.05[[3/4]| 45| 34| N/A| 11| 8/.99| 15/.98| 23/.96| 24/.95|
20/.93| 17/.92| 14/.91| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 23| 17| N/A| 5| 8/.99| 15/.98| 23/.96| 30/.95| 30/.93|
30/.92| 30/.91| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 45| 34| N/A| 11| 8/1.00| 15/.99| 23/.99| 24/.98|
20/.97| 17/.97| 14/.96| 11/.96| 8/.95| 5/.95
12.7[1/2]| 22.23[7/8]| 23| 17| N/A| 5| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.97|
30/.97| 30/.96| 30/.96| 30/.95| 30/.95
5 Ton| 9.53[3/8]| 19.05[3/4]| 24| 17| N/A| 0| 8/.99| 15/.97| 23/.94| 19/.92|
14/.90| NR| NR| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 12| 8| N/A| 0| 8/.99| 15/.97| 23/.94| 30/.92| 30/.90|
NR| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 24| 17| N/A| 0| 8/1.00| 15/.99| 23/.98| 19/.97| 14/.96|
10/.95| 5/.94| NR| NR| NR
12.7[1/2]| 22.23[7/8]| 12| 8| N/A| 0| 8/1.00| 15/.99| 23/.98| 30/.97| 30/.96|
30/.95| 30/.94| 29/.94| 28/.93| 2/.92
9.53[3/8]| 28.58[1-1/8]| 24| 17| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 19/1.00|
14/1.00| 10/.99| 5/.99| NR| NR| NR
12.7[1/2]| 28.58[1-1/8]| 12| 8| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 30/1.00|
30/1.00| 30/.99| 30/.99| 29/.99| 28/.99| 27/.98
Notes:**
1. Do not exceed 200 ft linear line length.
2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Performance Data @ AHRI Standard Conditions – Cooling
Designated Test Combinations (DTC)
Outdoor Unit| Indoor Coil| Total Capacity
BTU/H [kW]
| Net Sensible
BTU/H [kW]
| Net Latent BTU/H
[kW]
| SEER| EER| Inddor CFM [L/s]
RP1624AJ| TZHDLVMT2421| 24000 [7]| 19200 [5.6]| 4800 [1.4]| 16| 13| 825 []
RP1636AJ| TZHDLVMT3621| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 16| 13| 1225 []
RP1648AJ| TZHDLVMT4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 16| 12.5| 1650
[]
RP1660AJ| TZHDLVST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 16| 12.5|
1725 []
Note: Additional ratings and system match ups can be accessed on MyRheem.com
at: https://my.rheem.com/static/private/ahriresidential.html
Additional ratings and system match ups and downloadable ratings certificates
can be accessed from the AHRI website:
www.ahridirectory.org
[ ] Designates Metric Conversions
**GENERAL TERMS OF LIMITED WARRANTY***
Rheem will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance with
the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required) Ten (10) Years