ROARBATT B0BMT12BZR Pure Sine Wave Power Inverter User Manual
- June 11, 2024
- ROARBATT
Table of Contents
POWER INVERTER
PURE SINE WAVE
USER MANUAL
ROARBATT is committed to providing each customer with the highest standard of customer service.
GENERAL INFORMATION
The ROARBATT Pure Sine Wave Power Inverter delivers outstanding performance
for back-up power and off-grid system, which is widely used in emergencies or
household.
The advanced pure sine wave technology provide cleaner, smoother and more
reliable power for sensitive equipment without any interference.Brilliant
design using top electronic materials makes it safe,stable with long machine-
life.
-
Pure Sine Wave
The ROARBATT power inverter output a pure sine wave waveform, which has the same quality as utility or domestic power. This smooth pure sine wave allows you to operate sensitive electronic devices that require a high quality waveform with little harmonic distortion.Almost any electronic device could be powered using ROARBATT PURE SINE WAVE INVERTER.
ROARBATT pure sine wave inverter is more efficient(high efficiency 90%) which able to use less energy and allow more devices to be used.More energy savings from low no-load losses. Superb load shock resistance will not harming your equipment when running. -
Soft Start Technology
Thyristor soft start technology included can effectively reduce the starting inrush current of the inverter, reduce the impact on the power grid, improve the quality of power and the appliance life.Overall, it improve the stability and reliability of the system which is especially necessary for equipment that has an inductive load or electrical motor. To better protect the machine, you’d better turn on the switch of the appliance first before starting the inverter.
AFTER-SALES SERVICE
Dear user:
ROARBATT adheres t o the principle of comprehensive, high quality and fast
service.
Taking your satisfaction as the highest goal, we provide you with the
following services:
-
Free 2-year warranty for the ROARBATT pure sine wave power inverter.
-
All feedback on the quality and use of the product will be replied t o within 24 hours. And we will determine the measures t o deal with the actual situation based on your feedback.
-
In the case of quality problems under normal use, please contact us as soon as possible to facilitate the timely repair and replacement of your products.
-
lf any problems with products that are out o f warranty, please contact us and we will try our best t o assist you in solving the problem.
-
The following situations are not covered by the warranty:
a.Self-disassembly products
b.Unauthorized repair, misuse and modification.
c.Damaged by abnormal voltage, fire, liquid and other external causes
d.Abnormal storage conditions like overheating, humidity.
e.Damage due to reverse polarity . -
Contact Email Address:
Amazon Seller Support: hengwugz207@163.com
ROARBATT Seller Support: roarbatt@yeah.net
ROARBATT
NO.| Items| Technical parameters
1| Input rated voltage| 12V DC| 24V DC
2| Input voltage Range| 9.5-16V DC| 19-32V DC
3| Output Voltage Range| 120VAC±10%
4| Output Frequency| 60Hz± 1Hz
L’)| Output Waveform| Pure sine wave
6| Total Harmonic Distortion| ≤3%@Linear load
7| Maximum con version of f iicency| About 90%
8| No-load current| 0.6±0.2A| 0.3±0.2A
9| Undervottage alert| 10±0.5V| 20±1V
10| Undervoltage protection| 9.5±0.5V| 19±1 V
11| Undervottage protection recovery| 12.5±0.5V| 25±1 V
1 2| Overpressure protection| 16±0.5V| 32±1V
13| Overpressure protection recovery| 14±0.5V| 28±1V
14| Overload protection recovery| Yes
15| Short circuit protection recovery| Yes
ROARBATT
NO.| Items| Technical parameters
16| USB output
voltage| 5±0.2V
17| USB output
current max| 3.4A
18| Remote
Control| Wired remote control
19| Buzzer
operating
status| Intermittent beeping — indicates “battery undervoltage”.
Three consecutive beeps —”protection.
the machine enters the protection state, no voltage output.
20| Fan working
status| The temperature inside the machine >45°C
or the power reaches 40% or more fan starts to run.
The temperature inside the machine <42°C
or the power is below 30% fan stops running.
21| LCD indicates
working
status| Green light —”power on Indicator’
The red light “fault light” lights up the
machine into the protection state, no voltage output.
22| Display
Status| Normal display:
Battery voltage
Ambient temperature
Batter status
Output frequency
Output Voltage
Output power pure sine wave form
Alarm display:
Fault 2 Indicates under voltage alert
Fault 3 Indicates over-voltage protection
Fault 4 indicates under-voltage protection
Fault 5 Indicates overload warning
Fault 6 Indicates overload protection
Fault 7 indicates over temperature protection
Fault 8 indicates output short circuit protection
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions carefully .
In order that you can better use this inverter and prevent accidents of
personal injury and object damage, please focus on the contents of the safety
precautionary points and use common sense in life t o operate the inverter
carefully.
This manual contains important safety, installation and operating instructions
for the inverter.Please be sure t o read and comply with the following symbols
in this manual:
Indicates what must be performed
Indicates what must be performed
Indicates prohibited operations
-
MH General Safety Information
NEVER disassemble or attempt to repair the inverter without the guidance of a professional ROARBATT service team staff .
Installation and wiring must comply with the Local and National Electric Codes (NEC) and must be done by a certified technician.
Read all of the instructions and cautions in the manual before beginning the installation..
Make sure all connections going into and from the inverter are tight. There may be sparks when making connections, therefore, make sure there are not flammable materials or gases near installation. -
Electric Safety
WARNING
NEVER connect the AC output of the unit directly t o an Electrical Breaker
Panel/ Load Centre which i s also fed from the utility power / generator.
NEVER use with positive ground electrical systems.The unit i s designed to be
used with a negative ground electrical system!
Make sure the inverter i s off before connecting anything.
When connecting battery terminals, ensure the polarity of the battery
connections is correct. Incorrect polarity may cause permanent damage to the
unit.
ALWAYS make sure inverter i s in OFF position and disconnect all AC and DC
connecting when working on any circuit associated with the inverter.
Be careful when touching bare terminals of capacitors as they may retain high
lethal voltages even after power is removed.
- Installation Safety
Placement Requirements
Make sure there is enough space and that the installation is done according to the guidelines
WARNING
NEVER install the inverter in a sealed enclosure with flooded batteries.Gas
can accumulate and there is a risk of explosion.
NEVER mount the inverter vertically on a vertical surface since it would
present a hazard for the fan opening which will affect your inverter’s life
and even causing other dangers.
NEVER mount the inverter upside down.
ROARBATT Inverter should be placed in a horizontal position.
Well-ventilated area — Allow at least 12 inches of clearance around the
inverter to keep objects from blocking the vents and to provide adequate air
circulation.
Dry —No liquids are allowed near the inverter. It should be in a place where
there is no moisture of any kind.
Cool— Inverters must be in an area where the fans are not blocked.Do not put
the inverter under direct sun light or near a heating source. The ambient
temperature should be controlled from 32 to 104°F (preferred temperature of
50-77°F).
Less dust area-Do not install the inverter in an environment with high dust,
saw dust residue or other particles that may get sucked into the inverter
increasing internal temperature.
Close proximity to battery bank — prevent excessive voltage drop by keeping
the unit close to the battery bank and having a properly sized wire going from
the battery bank to the inverter.
Protection against fire hazard —There will be some electrical arcing or spark
when the inverter connects with the battery. The unit should be away from any
flammable material, liquids,gas or any other combustible material.Otherwise it
may cause severe consequences.
Separate compartment from battery — Do not install the inverter in the same
compartment as the battery bank because it could serve as a potential fire
hazard..
CAUTION
Cockroaches or other insects may cause damage to the machine, so please take
care to keep the machine and the surrounding environment hygienic.
RECOMMENDATION
We recommend mounting the inverter on something stable such as floor , table
or stable support to prevent it from bouncing. Mount in a location that can
support the weight of the inverters. It i s better to fix the product with
four screws.
SPECIAL NOTES FOR CHILDREN
NEVER allow children to use the inverter.
NEVER install the unit where it is accessible to children.Keep the unit away
from children.
Accessories may cause harm to children, please place all accessories in places
that are not easily accessible to children.
DC Side Connection Requirements
WARNING
The ROARBATT pure sine wave inverters are suitable for 12V battery bank
systems only. not following the minimum DC requirement will cause irreversible
damage to the unit.
CAUTION
Be careful of the positive and negative poles. Reversing the poles might cause
permanent damage to the inverter. It will surely blow the internal fuse.
NOTE
The input terminals of the inverters have large capacitors connected to
them.Once a positive and negative wire are connected to the terminals, it will
complete the circuit , and commence drawing a heavy current momentarily.As a
result, there may be a sparking occurring even if the inverter is in the off
position. To minimize sparking, it is recommended that the user have the
appropriate size wire feeding into the inverters and/or install an external
fuse leading into the inverter.
SECURE CONNECTION OF THE INVERTER
a. NEGATIVE:Connect one side of the provided Negative(BLACK)DC cable to the
Negative(-)
bolt of the inverter,and the other side to the Negative(-)post of the battery
.
b.POSITIVE: Connect one side of the provided Positive(RED)DC cable to the
Positive(+)bolt of the inverter, and the other side to the Positive(+)post of
the battery.
c. The nuts of the connection posts must be tightened to ensure a good
connection.
d.SWITCH BUTTON: Please note that the switch has 3 gears. From top to bottom
are on, off and remote.
e.The inverter will shutdown automatically if connection
reversed.|Irreversible damage to the machine cannot be excluded which will
affect your warranty.
Battery Bank Requirements
The battery is for supplying DC input voltage to the inverter. Its rated
voltage should be the same as the rated input voltage of the ROARBATT
inverter.Any voltage that exceeds the input voltage range of the inverter will
cause the inverter to be overloaded and may damage the inverter.
The battery ought to supply enough current for the load.(The load i s the
amperage or wattage rating of the equipment being powered by the inverter.)
Asmall capacity battery cannot supply enough power for large electrical
equipment and it will cause the inverter to be under-voltage.
The battery is for supplying DC input voltage to the inverter. Its rated
voltage should be the same as the rated input voltage of the ROARBATT
inverter.Any voltage that exceeds the input voltage range of the inverter will
cause the inverter to be overloaded and may damage the inverter.
The battery ought to supply enough current for the load.(The load is the
amperage or wattage rating of the equipment being powered by the inverter.)
Asmall capacity battery cannot supply enough power for large electrical
equipment and it will cause the inverter to be under-voltage.
SIMPLE METHOD
For determining the required battery capacity size is shown below for
reference:
-
Determine the Watts (Amps * Volts) of the load
(Each appliance has technical specifications indicating the wattage o r voltage and amperage required for operation.) -
Utilize the formula Amps=Watts/ Volts
-
Inverter consumption=Amps*10%
(Due to inverter efficiency 90% ,the recommended estimate for the calculation is 10%) -
Estimated load runtime
(The capacity of the battery depends on the load wattage and runtime. Most loads are not constant, so estimation i s essential.) -
Determine Ah(Ampere-Hour) of the battery
(Amps + consumption) * hours = recommended battery capacity
Grounding Requirements
The ROARBATT Pure Sine Wave inverters come equipped with a ground terminal to
appropriately ground to earth or to another designated ground. (for example, a
metal frame of an RV).
The connections to ground must be tight and against bare metal. Whether using
the inverter ina mobile application, such as an RV, or in a building,
grounding is highly recommended.
RECOMMENDATION
The recommended wire size for grounding is 14AWG or larger insulated copper
strand wire.
For more information regarding grounding, users and/or installers must consult
with the Local and National Electric Codes(NEC) for more specific grounding
regulations and suggestions as they can change per scenario.
- Operation Safety
Assuming proper battery connection, the inverter is now ready for use.
The ROARBATT Pure Sine Wave inverters come equipped with a ground terminal to
appropriately ground to earth or to another designated ground. (for example, a
metal frame of an RV).
The connections to ground must be tight and against bare metal. Whether using
the inverter ina mobile application, such as an RV, or in a building,
grounding is highly recommended.
RECOMMENDATION
The recommended wire size for grounding is 14AWG o r larger insulated copper
strand wire.
For more information regarding grounding, users and/or installers must consult
with the Local and National Electric Codes(NEC) for more specific grounding
regulations and suggestions as they can change per scenario.
• Use Safety
- Do not operate the inverter if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgement or reflexes are impaired while taking drugs. If there is any doubt, do not operate the inverter.
- People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a pacemaker could cause interference to or failure of the pacemaker.
- Avoid unintentional starting. Be sure the switch is in the OFF position when not in use and before plugging in any appliance.
- The power inverter will output the same AC power as utility power, please treat the AC as carefully as you would treat an AC outlets at home. Do not put anything besides the outlets appliance into the output terminals. It may cause electric shock or fire.Do not put anything besides the electrical appliance into the output terminal. It may cause electric shock or fire.
PROTECTION DESCRIPTION
a. Input under-voltage alarm: When the input DC voltage is lower than 9.8V ,
the buzzer will whistle intermittently to remind that the inverter will go
into the under voltageprotection.
b.Under voltage protection: The inverter will automatically shut down when the
input DC voltage is lower than 9.5V.The buzzer will whistle continuously and
the green light is off, red light is on. Please turn off the inverter and use
it after recharging the battery.
c.Over voltage protection:The inverter will automatically shut down when the
input DC voltage is higher than 16V.The buzzer will whistle continuously and
the green light is off, red light is on. Please turn off the inverter and
adjust the input voltage to the admissible range.
d. Overload protection: The inverter will automatically shut down when the
load is higher than the rated power. The buzzer will whistle continuously.
Turn off the inverter and resume to normal operation after taking away the
excessive load.
e. Short-circuit protection: The AC output will be automatically shut down
when short circuited. It will automatically reset after the problem is solved.
f. Thermal protection: The unit will get hot during operation. If the
temperature is higher than 149°F, the inverter will automatically shut down.
Then the buzzer will whistle continuously and the green light is off, red
light is on. Please turn off the inverter, and continue using it after the
temperature goes back to normal naturally. Meanwhile find out the factors
causing the fault, such as ventilation, ambient temperature, vent, load power
etc. It can avoid similar things from happening again.
TROUBLESHOOTING TIPS
Problem | Potential Issue | Proper Solution |
---|---|---|
No output voltage with buzzer sounds continuously | Under-voltage | • Charge or |
replace the battery.
• Try to restart the inverter several times due to under-voltage caused by
excessive transient current.
Over-voltage| • Do not start the Inverter while the battery is charging.
• Check the rated voltage of the battery with RMS meter to ensure it is match
with the inverter parameters.
Overload| Reduce the load on the inverter.
Overheat| • Avoid blocking the cooling fan and check for Sufficient
ventilation.
• Allow the inverter to cool to normal temperature then restart it.
• Reduce the load.
Not output voltage nor sounds.| 1.The switch is off 2.Poor cable connection|
1. Confirm the switch is on.
2. Inspect terminals and tighten all cables
Unable to run equipment| 1. 0verload,or the actual running power of the
equipment exceeds nominal power.
2. Higher starting power than rated peak power of the equipment (especially
with motor).
3. Low battery level or poor battery condition.| 1. Reduce the load,or
replace a larger power inverter.
2. Turn on the equipment first,then the power inverter.
3. Ensure the battery was charged or replace a good condition one.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>