■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com
Last handset must be connected to the IN/OUT connection of the last 3468 41 to close the BUS and reduce system interference
■ We recommend Bticino cable Cat. No. 3369 04, see guidance notes for usage of different cable types BUS cable connections are non polarised meaning the cable cores can be terminated in either connection terminal
ALL CONFIGURATION SHOULD BE DONE WHILE THE SYSTEM IS POWERED OFF!
ENTRANCE PANEL CONFIGURATION
Mic/Speaker adjustment Use orange adjustment tool provided with A/V module
EXAMPLE HANDSET CONFIGURATION ■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com
DOOR LOCK WIRING EXAMPLES
EXAMPLE 1 – Fail secure door dock (energise to open) EXAMPLE 2 – Fail safe door dock (de-energise to open) EXAMPLE 3 – Motorised gates / volt free control■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com
ENTRANCE PANEL MOUNTING AND CABLING GUIDELINES
■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com
RECOMMENDED MOUNTING HEIGHTS AND FIELD OF VIEW (to centre of camera)
CABLING GUIDELINES
LINE max. distance| 2 core untwisted 0.2 mm| Cat 5
single twisted pair| Telephone single twisted pair 0.28 mm|
Bticino 3369 04 / 3369 05
---|---|---|---|---
A| 50 m| 125 m| 125 m| 200 m
B| 50 m| 70 m| 70 m| 150 m
C| 50 m| 75 m| 75 m| 170 m
D| 10 m| 30 m| 30 m| 50 m
■ Recommended cable 3369 04/3369 05 for best performance
We cannot guarantee the performance of 3rd party cable suppliers
OPTIONAL ADVANCED SETTINGS AND FEATURES
FLOOR CALL (doorbell) A non-illuminated bell push can be wired to the
pushbutton terminals of the internal handset, this will ring the internal unit
with a different audio tone to let you know that somebody is at the apartment
door
This removes the need to install a separate bell transformer and chime
The maximum distance between the call to the floor push button and the
internal unit is 15 m
DOOR LOCK TIMING (T configuration) As default, the speaker module without a configurator in the “T” slot will allow the door lock to operate for 4 seconds, if a different door lock operation time is desired, you can change the door lock timing to match the table below (additional purchase of configurators may be required)
Configurator Number
0 (no configurator)| 1| 2| 3| 5| 6| 7
4 sec| 1 sec| 2 sec| 3 sec| 6 sec| 8 sec| 10 sec
For door lock times greater than 10 seconds and/or different lock requirements please contact our technical support team who would be more than happy to assist
TROUBLESHOOTING
System does not power up
- Check the incoming supply of the power supply is 230 V
- Check the BUS voltage on BUS terminals of all devices is 27 V DC
- Check for loose connections on the system
System powers up but does not call correctly
- Check the BUS is 27 V DC is at every point, including entrance panel and internal handsets and make sure that the BUS is wired to the correct terminals on each device
- Check entrance panel and handset configurators are correct, please see the configuration guide on p. 3
- Reset the power to the system. The configuration must be done with the system powered off as the configuration only gets read into the system when it is powered up
- Check you are pressing the correct call button, please see the call button positions on p. 3 which shows the configuration positions of the call buttons
- Check the JMP configurator is correct in the J1 slot of the entrance panel as shown on p. 2 and 3, once this has been changed a power reset must be performed to read in the new configuration
- If the handset is not calling, check the ringer volume settings on the right-hand side of the internal unit to make sure the ringer volume is at a suitable level, see p. 3
Door lock is not working correctly
- Check 12-18 V DC is on terminals S+ and S- of the entrance panel whilst the door lock button on the handsets is being pressed
- Check the door lock wiring is correct for the type of door lock you have, see p. 4
- Check the push to exit button (if installed) is a sprung return N/O push switch
Video has interference
- Low voltage cabling should not be run with mains equipment, check the wiring runs are not being run along with power cables anywhere on the system
- Check end of line switches are set to the ‘ON’ position for every internal handset as shown on p. 3
- Make sure you are using the correct type of twisted pair cabling as recommended within the cabling guidelines shown on p. 5 (do not double up on a cat 5, use a single twisted pair i.e. brown pair)
- Check BUS TK and BUS PI connections on the power supply are wired correctly. BUS TK should feed the entrance panel and BUS PI should feed the internal units/distribution blocks
Audio low / squealing
- If you hear squealing at the entrance panel during conversation (Larson effect) this could be due to the mic and loudspeaker adjustments both being set too high causing the A/V module to self amplify. Fine tune the mic and speaker until squealing stops and the desired audio level is achieved. These can be found on the front of the A/V module and adjusted using the orange adjustment tool supplied with the A/V module, see p. 3
- Low speech audio can be rectified with fine tune adjustment to the mic and loudspeaker. The settings for these are located on the front of the A/V module of the entrance panel and can be changed using the orange adjustment tool supplied with the A/V module, see p. 3
Contact details
United Kingdom
Great King Street North,
Birmingham, B19 2LF
Customer Services:
Tel: +44 (0) 345 605 4333
E-mail: legrand.sales@legrand.co.uk
Quotations and Technical Support:
Tel: +44 (0) 370 608 9020
E-mail:
doorentry.uk.technical@legrand.com
Republic of Ireland:
Tel: 01 295 9673
E-mail: legrand.sales@legrand.co.uk
FOLLOW US AT
| www.legrand.co.uk
www.legrand.ie
---|---
| www.youtube.com/legrandtvuk
| www.twitter.com/legranduk
|
www.linkdin.com/company/legranduk
Head office (UK and Ireland):
Legrand Electric Limited
Great King Street North, Birmingham, B19 2LF
Tel: +44 (0) 370 608 9000
Website: www.legrand.co.uk
In accordance with its policy of continuous improvement, the Company reserves
the right to change specifications and designs without notice. All
illustrations, descriptions, dimensions and weights in this catalogue are for
guidance and cannot be held binding on
the Company. All contents and design presentation included in this publication
are © Legrand Electric Limited. All rights reserved. 2023.
Bticino multi way door entry kits installation guide 10/2023
The Legrand logo is a registered trademark of the Legrand group of companies.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>