legrand bt14wakit Multi Way Audio And Video Door Entry Kits Installation Guide

June 13, 2024
Legrand

MULTI WAY AUDIO AND VIDEO
DOOR ENTRY KITS
14 WAY AUDIO DOOR ENTRY KIT
legrand bt14wakit Multi Way Audio And Video Door Entry
Kitslegrand bt14wakit Multi Way Audio
And Video Door Entry Kits - INSTALLATION GUIDE

bt14wakit Multi Way Audio And Video Door Entry Kits

POWERED BY SPECIALISTS

■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com

legrand bt14wakit Multi Way Audio And Video Door Entry Kits -
fig1■ We recommend Bticino cable Cat. No. 3369 04, see guidance notes for usage of different cable types BUS cable connections are non polarised meaning the cable cores can be terminated in either connection terminal

ALL CONFIGURATION SHOULD BE DONE WHILE THE SYSTEM IS POWERED OFF!

ENTRANCE PANEL CONFIGURATION

legrand bt14wakit Multi Way Audio And Video Door Entry Kits -
fig2

DOOR LOCK WIRING EXAMPLES

legrand bt14wakit Multi Way Audio And Video Door Entry Kits - DOOR
LOCK

ENTRANCE PANEL MOUNTING AND CABLING GUIDELINES

BACKBOX SIZES

Surface mounting backboxes with in-built rainshields

Dimensions (mm)

Cat. Nos.| A| B| C
BT4WAKIT| 151| 151| 82
BT4WVKIT
BT6WVKIT
BT6WAKIT
BT8WVKIT
BT8WAKIT
BT10WVKIT
BT10WAKIT
BT12WAKIT| 151| 242| 82
BT12WVKIT
BT14WVKIT
BT14WAKIT
BT16WVKIT
BT16WAKIT
BT18WVKIT
BT18WAKIT| 151| 334| 82

CABLING GUIDELINES MOST COMMON CABLES

legrand bt14wakit Multi Way Audio And Video Door Entry Kits - Entrance
panel

LINE
max. distance| 2 core untwisted
0.2 mm| Cat 5 single twisted
pair| Telephone single
twisted pair 0.28 mm| Bticino
3369 04/3369 05
---|---|---|---|---
A| 50 m| 125 m| 125 m| 200 m
B| 50m| 70m| 70m| 150m
C| 50m| 75m| 75m| 170m
D| 10m| 30m| 30m| 50m

Recommended cable 3369 04/3369 05 for best performance We cannot guarantee the performance of 3rd party cable suppliers

OPTIONAL ADVANCED SETTINGS AND FEATURES

DOOR LOCK TIMING (T configuration)

legrand bt14wakit Multi Way Audio And Video Door Entry Kits -
SETTINGS As default, the speaker module without a configurator in the “T” slot will allow the door lock to operate for 4 seconds, if a different door lock operation time is desired, you can change the door lock timing to match the table below (additional purchase of configurators may be required)

Configurator Number

0
(no configurator)| 1| 2| 3| 5| 6| 7
4 sec| 1 sec| 2 sec| 3 sec| 6 sec| 8 sec| 10 sec

For door lock times greater than 10 seconds and/or different lock requirements please contact our technical support team who would be more than happy to assist

TROUBLESHOOTING

System does not power up

  • Check the incoming supply of the power supply is 230 V
  •  Check the BUS voltage on BUS terminals of all devices is 26 V DC
  • Check for loose connections on the system System powers up but does not call correctly
  • Check the BUS is 26 V DC at every point, including entrance panel and internal handsets and make sure that the BUS is wired to the correct terminals on each device
  • Check entrance panel and handset configurators are correct, please see the configuration guide on p. 3
  • Reset the power to the system. The configuration must be done with the system powered off as the configuration only gets read into the system when it is powered up
  • Check you are pressing the correct call button, please see the call button positions on p. 3 which shows the configuration positions of the call buttons
  • Check the JMP configurator is correct in the J1 slot of the entrance panel as shown on p. 2 and 3, once this has been changed a power reset must be performed to read in the new configuration
  • If the handset is not calling, check the ringer volume settings on the right-hand side of the internal unit to make sure the ringer volume is at a suitable level, see p. 3

Door lock is not working correctly

  • Check that 12-18 V DC is on terminals S+ and S- of the entrance panel whilst the door lock button on the handsets is being pressed
  • Check the door lock wiring is correct for the type of door lock you have, see p. 4
  • Check the push to exit button (if installed) is a sprung return N/O push switch

System has interference

  • Low voltage cabling should not be run with mains equipment, check the wiring runs are not being run along with power cables anywhere on the system

Audio low / squealing

  • If you hear squealing at the entrance panel during conversation (Larson effect) this could be due to the mic and loudspeaker adjustments both being set too high causing the A/V module to self amplify. Fine tune the mic and speaker until squealing stops and the desired audio level is achieved. These can be found on the front of the A/V module and adjusted using the orange adjustment tool supplied with the A/V module, see p. 3
  • Low speech audio can be rectified with fine tune adjustment to the mic and loudspeaker. The settings for these are located on the front of the A/V module of the entrance panel and can be changed using the orange adjustment tool supplied with the A/V module, see p.3

Contact details
United Kingdom
Great King Street North,
Birmingham, B19 2LF
Customer Services:
Tel: +44 (0) 345 605 4333
E-mail: legrand.sales@legrand.co.uk
Quotations and Technical Support:
Tel: +44 (0) 370 608 9020
E-mail: doorentry.uk.technical@legrand.com
Republic of Ireland:
Tel: 01 295 9673
E-mail: legrand.sales@legrand.co.uk

In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on
the Company. All contents and design presentation included in this publication are © Legrand Electric Limited. All rights reserved. 2023.

www.legrand.co.uk
www.legrandie
www.youtubescomilegrandtvuk
www.twitter.comilegranduk
www.linkedin.com/cornpany/legranduk

Head office (UK and Ireland):
Legrand Electric Limited Great King Street North, Birmingham, B19 2LF
Tel: +44 (0) 370 608 9000 Website: www.legrand.co.uk
The Legrand logo is a registered trademark of the Legrand group of companies.
Bticino multi way door entry kits installation guide 10/2023

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals