Wi-Q Wireless Access Management
Owner’s Manual
WI-Q
Wireless Access Management
by BEST
Introduction
BEST Wi-QTM Wireless Access Solution offers exceptionally efficient wireless access control technology compatible with a host of access control systems including dozens that communicate with Mercury panels. Please check bestaccess.com for a complete list of currently integrated software platforms Wi-Q utilizes BEST 9KQ, 45HQ and EXQ heavy-duty electronic lockset product lines and is more compatible and secure with features you’ve come to trust.
- 128-bit AES security encryption for wireless connections
- Gateway housing that can hide in plain sight
- Supports a multitude of credential formats
- Scales up to as many as 14,000 credentials per lock
- Manages user access wirelessly from a centralized platform
- Performs its own security updates every 60 seconds, every day
- Installs easily and retrofits in a snap with integrated components
- Direct integrations to Softwarehouse C-Cure and Lenel OnGuard
Additional Features
- Door position switch
- Request-to-exit sensor
- Latch switch sensor
- Key override sensor
Also available is a Wireless Access Controller (WAC) module that provides
wireless control for use with parking gates, turnstiles, electromagnetic
locks, electric strikes, and other electronic devices.
Wi-Q’s overall design gives you uncompromising wireless access intelligence
and security.
BEST WI-Q Technology Wireless Access
Management System
The Intelligent Option
Standard Hardwired System
Installation of multiple separate components and wire runs.
BEST WI-Q
Install wireless gateway and lock; connect to wireless signal.
Locking Hardware—Features
- Heavy-duty mechanical platform designed and Dynamic memory up to 14,000 credentials per reader
- Each reader has unique MAC address
- Battery-powered by AA battery case (battery pack optional)
- All intelligence is at the door
- Approximately 8.7K-event audit trail stored dynamically at reader
- 512 time zone user groups per reader with 6 intervals each
- 256 holidays
- ADA-compliant locksets
- Available in cylindrical, mortise, exit device, and wireless access controller configurations
- Remote reader diagnostics from PC (battery level and signal strength of each lock)
- Supported readers include Magnetic Stripe, Mag Stripe + Keypad, 125 kHz Proximity, 13.56MHz Smart Card, Proximity + Keypad,
eLocks | 9K | 45H | EX |
---|---|---|---|
Request to Exit | Yes | Yes | Yes* |
Door Position Switch | Yes | Yes | Yes |
Card Reader | Yes | Yes | Yes |
Latch Switch | No | Yes | Yes* |
Deadbolt Override | NA | Yes | NA |
Key Override Sensing | Yes | Yes | Yes |
*Provided by exit device, but supported by exit trim.
WI-Q — Integrating With Access Control Systems
BEST Wi-Q powers wireless integration and flexibility with a combination of
secure portal gateways and wireless access controllers.
Our portal gateway creates a secure wireless connection between locks and an
expanding array of access control platforms. With an integration to mercury
panels, Wi-Q is compatible with a host of access control platforms. Wireless
Access Controllers enable existing hardwired entries such as turnstiles, entry
gates or reader-controlled doors to be retrofit to the system. All data flows
through the portal gateway to your host access control system for easy
monitoring.
WI-Q Wireless Technology Lock
Wireless Gateway Features
-
Wireless site survey functionality built in
-
Communicates at 2.4GHz spread spectrum to wireless readers or wireless access controllers
-
Uses 802.15.4 protocol with clear channels above 802.11 to allow Wi-Fi interoperability
-
10/100/1000 Base-T Ethernet
-
Provides redundant communication (locks attached to the strongest signal)*
-
Non dedicated portal can communicate with 1 to 64 readers.
(Does not imply that 64 readers/locks will be within distance of RF range to connect. Total number of portal gateways required is based on individual system survey
and requirements.) -
Does not require typical controller hardwiring, simply plug the portal gateway into an existing TCP/IP network and provide local POE power
Wireless Access Controller Features
- Wireless site survey functionality built in
- Provides wireless control of electric locks on glass/aluminum doors
- Provides relay control for various locking devices
- Recommended for exterior door applications
- Existing wired system can be converted to wireless technology
- 2 output relays (Form-C) control external devices (alarms, electrified hardware, etc.)
- Monitors door latch, door status, and request to exit & key override
- Facilitates ADA compliance to control auto-open-type doors
- Provides control for local door alarm/sounders for door-held-open events
Mortise Lock Specifications
Case – 0.095″ cold rolled steel, 5-7/8″ (149mm) H x 7/8″ (22mm) D x
4-1/16″ (149mm) W.
Steel is zinc dichromate-plated for corrosion protection..
Faceplate – Brass or bronze material, 8″ (203mm) H x 1 1/4″ (31mm) W x
1/16″ (1mm) T.
Lock face automatically adjusts to proper bevel during installation
Strike – Brass, bronze, or stainless steel base material, 4-7/8″ (124mm)
H x 11/4″ (31mm) W x 3/32″ (2mm) T. Fits standard door frame cutout as
specified in ANSI A115.1. Universal (nonhanded) strike supplied standard with
lock..
Backset – 2-3/4″ (69mm)
Certification – UL listed for GYQS electrically controlled single point
locks or latches for use on 3 hour A label doors. The listing applies for both
U.S. and Canadian applications.
Door thickness – Standard lock configuration designed for doors 1-3/4″
thick.
Thick door configuration available for door to 3″ thick (specify thickness
when ordering)..
Latchbolt – Solid stainless steel, 3/4″ (19mm) throw. Latch is oil-
impregnated for antifriction operation. Reversible without opening case.
Deadbolt – Stainless steel, 1″ (25mm) throw.
Auxiliary bolt – Stainless steel, nonhanded..
Lever Handle – Brass, bronze, or stainless steel base material. Lever
styles 3, 14 and 15 return to a minimum of 1/2″ (12mm) of door surface. Levers
12, 16 and 17 do not return.
Escutcheon – 10-1/2″ (267mm) H x 3 7/16 (87mm) W x 1″ (25mm) D. 1″ (25mm)
at the top, sloping down to 3/4″ (19mm) at the bottom.
Finishes
- 605 – bright brass, clear coated
- 606 – satin brass, clear coated
- 611 – bright bronze, clear coated
- 612 – satin bronze, clear coated
- 613* – oxidized satin bronze, oil rubbed
- 619 – satin nickel plated
- 625 – bright chromium plated (brass base material)
- 626 – satin chromium plated (brass base material)
- 629 – bright stainless steel
- 630 – satin stainless steel
- 690** – dark bronze powder coated
Antimicrobial finishes –
- 626AM – Satin chrome plated with UltraShield antimicrobial coating
- 630AM – Satin stainless steel with UltraShield antimicrobial coating
- 613 finish is designed to wear over time, providing an “antique” appearance.
** 690 finish will continue as a dark brown appearance over time.
ADA — Americans With Disabilities Act – The design and operation of the
mortise lock meets the intent of the standard for ANSI A117.1 section 404.2.6
Builders Hardware Manufacturers Association – ANSI A156.13, Series 1000,
Grade 1 operational, strength, and security. To meet Grade 1 security, drill
resistant cores.
Underwriters Laboratories® – The 40H series is listed by Underwriters
Laboratories for use on a 3-hour A-label doors. These locks also carry the
C-UL mark, which is officially accepted in all of Canada, indicating
compliance with appropriate Canadian standards and codes.
UltraShield ™ – The UltraShield protection is limited to the product’s
surface and is not meant to be a substitute for good hygiene. BEST recommends
instituting and maintaining a thorough cleaning regimen of all your door
hardware.
Mortise Lock Functions
Function & Diag.| Latchbolt operated by:| Latchbolt deadlocked by:| Deadbolt
operated by:| Outside lever lockedand unlocked by:| Inside lever locked
and unlocked by:
---|---|---|---|---|---
TV Deadbolt With Key Override | Outside key
Outside lever – unless
locked by internal motor
drive mechanism
Inside lever| Auxiliary latch| Outside key
Inside turn knob
Outside lever when lever is
unlocked by internal motor drive
mechanism (retracts only)
Inside lever (retracts only)| Internal motor
drive mechanism
operated by timeactivated
electronicsignal or
by
validcard/PIN| Always unlocked
DV Latchbolt With Key Override | Outside key
Outside lever – unless
locked by internal motor
drive mechanism
Inside lever| Auxiliary latch| | Internal motor
drive mechanism
operated by timeactivated
electronic signal or by
valid card/PIN.| Always unlocked
Cylindrical Specifications
Materials – Internal parts are brass, zinc or corrosion-treated steel
Chassis – 2-1/16″ (52mm) diameter to fit 2-1/8″ (53mm) diameter hole in door
Strike – Brass, bronze or stainless steel base material; STK 2-3/4″ (69mm) H
standard,STK3 4-7/8″ (123mm) H. Fits standard door frame cutout as specified
in ANSI A115.1.
Strike box supplied as standard
Backset – 2-3/4″ (69mm) standard, 3-3/4″ (95mm) and 5″ (127mm) available
Door thickness – Standard lock configuration designed for doors
1-3/4″ (44mm) – 2-1/4″ (57mm) thick
Core housing – 7-pin core & NON-IC cores
Latchbolt – 9/16″ (24mm)
Lever handle – Manufactured from high – quality zinc alloy, coated to match
specified
finish. Body is approximately 1-5/8″ (41mm) in diameter; handle is
approximately
4-3/4″ (120mm) in length (from center of chassis). Lever styles 14 and 15
return to a
minimum of 1/2″ (12mm) of door surface. Lever 16 does not return.
Escutcheons – 10-1/2″ (267mm) H x 3-7/16″ (87mm) W x 1″ (25mm) D.
1″ (25mm) at the top, sloping down to 3/4″ (19mm) at the bottom.
Finishes –
-
605 – bright brass, clear coated
-
606 – satin brass, clear coated
-
612 – satin bronze, clear coated
-
613* – oxidized satin bronze, oil rubbed
-
625 – bright chromium plated (brass base material)
-
626 – satin chromium plated (brass base material)
-
690** – dark bronze powder coated
Antimicrobial finishes – -
626AM – Satin chrome plated with UltraShield antimicrobial coating
-
630AM – Satin stainless steel with UltraShield antimicrobial coating
-
613 finish is designed to wear over time, providing an “antique” appearance.
** 690 finish will continue as a dark brown appearance over time.
Cylindrical Lock Functions
Function & Diag.| Latchbolt operated by:| Outside lever locked by:| Outside
lever unlocked by:| Inside lever locked
and unlocked by:
---|---|---|---|---
TV Deadbolt With Key Override | Outside key
Outside lever — unless locked by internal motor drive mechanism
Inside lever| Internal motor drive
mechanism operated by timeactivated electronic signal
or by valid credential Latchbolt is deadlocked| Internal motor drive
mechanism operated by timeactivated
electronic signal or by valid credential| Always unlocked
Exit Trim Specifications
Materials – Internal parts are brass, zinc or corrosion-treated steel
Escutcheons – 11-5/”8 (295mm) H x 3-5/16″ (84mm) W x 1″ (25mm) D.
1″ (25mm) at the top, sloping down to 3/4″ (19mm) at the bottom Door thickness
– Standard lock configuration designed for doors 1-3/4″ (44mm) – 2-1/4″ (57mm)
thick
Lever handle – Brass, bronze, or stainless steel base material.
Lever styles 14 and 15 return to a minimum of 1/2″ (12mm) of door
surface. Finishes –
- 606 – satin brass, clear coated
- 613* – oxidized satin bronze, oil rubbed
- 626 – satin chromium plated (brass base material)
- 690** – dark bronze powder coated
Antimicrobial finishes –
- 626AM – Satin chrome plated with UltraShield antimicrobial coating
- 630AM – Satin stainless steel with UltraShield antimicrobial coating
- 613 finish is designed to wear over time, providing an “antique” appearance.
** 690 finish will continue as a dark brown appearance over time.
Exit Trim
- Exterior trim assembly compatible to exit hardware from PRECISION, Von Duprin, or Sargent 8000 rim device.
- Provides online lock capabilities for applications where building code requires exit hardware
- Exit trim comes standard with Door Position Switch (DS). It also comes with lead wires to connect to an optional
- Request-to-Exit (RQE) switch and an optional latch position switch available with the PRECISION line of exit devices.
- Request-to-Exit (RQE) & Latch Position Switch (LS) not available on PRECISION mortise locks
- The actual Request-to-Exit (RQE) & Latch Position Switch (LS) are never included with the EXQ trim.
- Those switches must be purchased separately.
- Exit hardware sold separately
See page 6 for certification descriptions.
Exit Trim Functions
Function & Diag. | Latchbolt operated by:| Outside lever locked
by:| Outside lever unlocked by:| Inside lever locked
and unlocked by:
---|---|---|---|---
EV with Key Override
NV without Key Override| Outside key
Outside lever — unless locked
by internal motor drive mechanism Touchbar| Internal motor-drive
mechanism operated by timeactivated electornic
signal| Internal motor drive
mechanism operated by timeactivated
electronic signal or by valid credential| Always unlocked
Exit Trim Compatibility Chart
Device Type | Precision 2000 | Von Duprin 98/99 |
---|---|---|
Rim – w/o key override | 2103 | 98TP, 99TP, 98L, 99L |
Surface Vertical Rod – w/o key override | 2203 | 9827TP, 9927TP, 9827L, 9927L |
Concealed Vertical Rod – w/o key override | 2703 | 9847TP, 9947TP, 9847L, 9947L |
Rim – with key override | 2103 | 98TP, 99TP, 98L, 99L |
Surface Vertical Rod – with key override | 2203 | 9827TP, 9927TP, 9827L, 9927L |
Concealed Vertical Rod – with key override | 2703 | 9847TP, 9947TP, 9847L, 9947L |
Locking Hardware Types and Technologies
The BEST Wi-Q Access Control Solutions supports:
- BEST mortise locks
- BEST cylindrical locks
- BEST wireless access controller platforms
- PRECISION exit devices
Lock reader types supported:
- HID ® 13.56MHz iCLASS ®
- HID ® proximity 125KHz
- Proximity Reader & keypad (PKP)
- Dual validation (magnetic stripe plus keypad)
- Magnetic stripe
WIQ Reader Selection
| |
---|---|---
PSEBH Multi-tech Reader
(13.56 MHz & 125kHz) Models:
• 9KQ
• 45HQ
• EXQ| ICLASS SE Reader
(13.56 MHz)) Models:
• 9KQ
• 45HQ
• EXQ| Standard Proximity Reader
(125 kHz) Models:
• 9KQ
• 45HQ
• EXQ
| |
PKP Proximity Keypad Reader
(125 kHz) Models:
• 9KQ
• 45HQ
• EXQ| Magnetic Strip Reader
Models:
• 9KQ
• 45HQ
• EXQ| Dual Validation Reader
(125 kHz) Models:
• 9KQ
• 45HQ
• EXQ
BEST WI-Q ™Components
Portal Gateways (WQXM) – New Mercury Compatible | Part Number |
---|
Portal Gateway for up to 64 Readers/Locks with half wave dipole
omnidirectional antenna (should only be used where PG is mounted in an open
area, not in a ceiling or restricted signal area).| WQXM-PG
Portal Gateway for up to 64 Readers/Locks with ceiling mount omnidirectional
antenna.| WQXM-PG-C
Portal Gateway in a mounting enclosure, without Power Supply. This would be
used with Power Over Ethernet (POE) devices (not included)| WQXM-PG-BP
Portal Gateway in a mounting enclosure, with ceiling mount omnidirectional
antenna, without Power Supply. This would be used with Power Over Ethernet
(POE) devices (not included)| WQXM-PG-C-BP
Portal Gateway for up to 64 Readers/Locks with wall mount directional
antenna| WQXM-PG-W
Wireless Access Controllers (WAC)| Part Number
Wireless Access Controller with half wave dipole omnidirectional antenna
(should only be used where WAC is mounted in an open area, not in a ceiling or
restricted signal area).| WQX-WAC
Wireless Access Controller with ceiling mount omni directional antenn| WQX-
WAC-C
Wireless Access Controller in enclosure with power supply and ceiling mount
omnidirectional antenna| WQX-WAC-C-B
Wireless Access Controller with wall mount directional antenna| WQX-WAC-W
Wireless Access Controller in enclosure with power supply and wall mount
directional antenna| WQX-WAC-W-B
Wireless Access Controller in Nema enclosure with power supply and exterior
directional antenna| WQX-WAC-D-BW
Wireless Access Controller in Nema enclosure with power supply and exterior
omni-directional antenna| WQX-WAC-O-BW
Wireless Access Controller sign-on keypad| WQD-WACPAD
Wireless Access Controller Survey Kit| WQD-Survey
Power and adapters| Part Number
Sealed battery pack| VPD-BB
Plug-in Transformer (wall-mount) with 6′ of cable| WQD-12827
Power over Ethernet Power Supply/Inserter| WQD-12927-001
Power over Ethernet Active Splitter with Isolation| WQD-12928-001
Wi-Q™ Antennas & Accessories| Part Number
2.4 GHz Interior Ceiling Mount Omni-directional Antenna kit| WQD-ACMO
2.4 GHz Interior/Exterior Wall mount directional antenna kit*| WQD-AWMD
2.4GHZ Exterior directional antenna| WQD-AEMD
2.4GHZ Exterior omnidirectional mast mount kit| WQD-AEMO
Exterior Antenna Grounding kit*| WQD-AGT
Surge Protection Kit| WQD-SURG
Cleaning Cards (box of 50)| VPDCLN
HID Proximity Card Enrollment Reader| RDR6081AKU
Antenna Kit include antenna, standard mount and 20’ cable to connec to PG or
WAC.
Antenna Kit includes antenna, wall and post mounts and 20’ cable to connect to PG or WAC.
Grounding Kit includes coax grounding kit and lighting arrestor.|
How To Order
EXQ| 7| EV| 15| MS| 626| RHR| PH2| RM|
---|---|---|---|---|---|---|---|---|---
Series| Core housing| Function
code| Lever style| Trim style| Finish| Door
hand| Mfg| Locking type| Options
EXQ| 0 – Less Core
Housing 7 – 7–pin
housing; accepts all
BEST cores| EV – With
key NV –
Without key| 14 – Curved w/
return 15 – Contour w/
angle return| MS** – Magnetic
stripe
DV – Dual validation(magstripe and keypad) PH – Proximity HID
® PKP – Proximity + Keypad
SE – iCLASS PSEBH – Proximity +
SE + HID BLE| 626 690
626AM
Satin
606 612
613| RHR
LHR| PH2 – Precision
Hardware 2000
series
VD9 – Von
Duprin 98/99
series| RM – Rim
MO – Mortise
RD – Surface and
concealed vertical
rods| SH – Security head
screws
MT1 – Track 1
MT2 – Track 2
MT3 – Track 3
NOTE: Wireless locks come standard with door position switch (DS),
connector/input to connect to a RQE switch inside exit device.
(RQE switch must be purchased separately for exit device brand and model).
NOTE: Latch Switch connector is also included for use with a latch switch
indicator only on Precision exit devices.
Indicates extra cost option; see below.
The EV function (key override) is not available on the Von Duprin Mortise
type.
Must specify track number.
BEST 9KQ Wireless Cylindrical Locks with Wi–Q ™ Technology Electromechanical Locks
How To Order
9KQ| 3| 7| DV| 14| MS| STK| 626|
---|---|---|---|---|---|---|---|---
Series| Backset| Core Housing| Function
Code| Lever Style| Rose Style| Strike
Package| Finish| Options
9KQ| 3 – 2–3/4″ 4 – 3–3/4″
5 – 5″| 0 – Non–IC
and LFIC
competitive
cylinder (less
core)
6 – 6 pin non–
IC cylinder
7 – 7–pin
housing; accepts
all BEST cores| DV – with key| 14 – Curved with return
15 – Contour with angle
return
16 – Curved without
return
4 – Round knob| MS –
Magnetic stripe
DV – Dual
validation
(magstripe and
keypad)
PH – Proximity
HID ® PKP – Proximity+ Keypad
SE – iCLASS PSEBH – Proximity + SE +
HID BLE| STK –
Standard
S3 – ANSI
S3 7/8 – Lip
to center
strike S3B – ANSI
(Stike w/ Plastic Box)
S3B 7/8 – ANSI (Stike w/ Plastic Box)| 626 690626AM
Satin
606 612 Bright
605 625| 8CE – 8 cell battery holder assy with batteries
4SW – 4 cell shrink wrap battery
P2 – Phillips head screws
LM – Lost motion
3/4 – 3/4” throw latch
0B – non–IC zero–bitted
COR – non IC Corbin Russwin
MED – non IC Medeco
SAR – non IC Sargent
SCH – non IC Schlage
YAL – non IC Yale
SARRC – LFIC Sargent
CORRC – LFIC Corbin
YALRC – LFIC Yale
SCHRC – LFIC Schlage
AL/O – Abrasive Lever Outside
AL/I – Abrasive Lever Inside
AL/B – Abrasive Lever Both
TL/O – Tactile Lever Outside
TL/I – Tactile Lever Inside
TL/B – Tactile Lever Both
FRL – Full Radius Latch
TRK1 – Track 1
TRK2 – Track 2
TRK3***** – Track 3
WS – Windstorm Label (Florida Building Code)
NOTE: Wireless locks come with Integrated Door Hardware (IDH) as standard –Request to Exit (RQE), Door Position Switch (DS)
- Indicates extra cost option.
Six–pin cylinder in Schlage “C” keyway included with 0B, KA, KD options. Must specify “6” for core housing.
* Cylinder not included with COR, MED, SAR, SCH, YAL, CORRC, YALRC, SARRC, or SCHRC options. Must specify “0” for core housing.
***T15 Torx security screws are supplied standard.
Must specify track number.
How To Order
45HQ| 7| TV| 14| MS| 626| RH|
---|---|---|---|---|---|---|---
Series| Core Housing| Function Code| Lever Style|
Trim Style| Finish| Door| Options
45HQ| 0 – Less Core
7 – 7–pin housing; cores| DV – Latch w/key
TV – Deadbolt w/key| L ev e r s :
12 – Solid tube/no return
14 – Curved/return
15 – Contour/angle return
16 – Curved/no return
17 – Gull wing
Knobs:
Decorative* | MS **** – Magnetic stripe
DV **** – Dual validation
DVA ** – Other cyl PH – Proximity HID® PHA – Other cyl MSA
** – Other cyl
PKP – Proximity + Keypad
PKPA – Proximity + Keypad
adaptation
SE – iCLASS
SEA – iCLASS smartcard
adapatation
PSEBH – Proximity + SE +
HID BLE
PSEBHA – Proximity + SE +
HID BLE Adaptation
| 626 630
690
626AM
630AM
Satin
613
Bright
625 629| RH RHRB LH LHRB| 8CE * – 8 cell battery holder assy with
batteries
4SW – 4 cell shrink wrap battery P2 – Phillips head screws Thick Door – Specify thickness 7/8″* – Flat lip strike
TAC/I – Tactile Lever Inside TAC/O – Tactile lever Outside
TAC/B * – Tactile Lever Both TRK1 ** – Track 1
TRK2 ** – Track 2
TRK3 ** – Track 3
WS** – Windstorm Label (Florida Building Code)
NOTE: Wireless locks come with Integrated Door Hardware (IDH) as standard
-Request to Exit (RQE), door position switch (DS), latch bolt monitor switch
(LS) and key-override switch (KOS) on DV Function.
Indicates extra cost option.
Indicates cost deduction.
T15 Torx security screws are supplied standard.
****Must specify track number.
How to Order Wireless Conversion Kits
Series | Description |
---|---|
WQCNKT-1 Cylindrical wireless upgrade kit | Kit to convert an Offline 9K V/G |
standalone lockset to a Wi-Q™ Wireless Lockset. Notes:
- Kit includes a new 9K chassis with new motor, RQE hub and door position
switch.
2) If the conversion kit will be used on a pre-2009 standalone lock with a HID Proximity Reader, it is highly recommended that a new HID Proximity reader is also purchased. The new style reader will provide better battery life than the pre-2009 HID Proximity Readers. (Part # 73132854S— B82399 45HQ HID PROX BEZEL SUB-ASSY HID)
WQCNKT-2 Mortise DV function (without deadbolt) wireless upgrade kit with alarm functionality| Kit to convert an Offline 45H V/G standalone lockset to a Wi-Q™ Wireless Lockset. Notes: - Kit also contains a new 45H DV mortise case which includes RQE, door
position switch, latch position switch and key-override sensor to provide for
full alarm functionality, circuit board and harness.
2) If the conversion kit will be used on a pre-2009 standalone lock with a HID Proximity Reader, it is highly recommended that a new HID Proximity reader is also purchased. The new style reader will provide better battery life than the pre-2009 HID Proximity Readers. (Part # 73132854S— B82399 45HQ HID PROX BEZEL SUB-ASSY HID)
WQCNKT-3 Mortise TV function (with deadbolt) wireless upgrade kit with alarm functionality| Kit to convert an Offline 45H V/G standalone lockset to a Wi-Q™ Wireless Lockset. Notes: - Kit also contains a new 45H TV mortise case which includes RQE, door
position switch, deadbolt position switch, and key-override sensor to provide
for full alarm functionality, circuit board and harness.
2) If the conversion kit will be used on a pre-2009 standalone lock with a HID Proximity Reader, it is highly recommended that a new HID Proximity reader is also purchased. The new style reader will provide better battery life than the pre-2009 HID Proximity Readers. (Part # 73132854S— B82399 45HQ HID PROX BEZEL SUB-ASSY HID)
BEST WI-Q At a Glance
Hardware Features
- Battery operated
- Programmed wirelessly
- 14,000 users per lock
- Audit trail function
- Number of time zones – 512 * 6 Intervals (3,072)
- Key override capability
- Pin #’s vary in length from 4-9 digits
- Cylindrical, Mortise and Exit Trim available
- Decision made at reader
- Supports multiple reader types including 125kHz prox and PKP readers,13.56MHz iCLASS, and more
FCC Compliance: Compliant with US, Canadian and European EMC requirements, and for FCC Class A digital apparatus interference
WI-Q Software Features
- Mercury systems compatible
- Door controllers per system: ………………………………………………………………………………………….5,000*
- Sign on/configuration tool (i.e., – PDA) required ………………………………………………..NO
- Door controllers per access point: ……………………………………………………………………………………….64
- Intelligence at the door: ……………………………………………………………………………………………………………………….YES
*These numbers have the ability to be much higher or lower depending on the user’s system configuration.
For questions about ordering and to be sure you get the right configuration
for your needs, contact your BEST dormakaba sales representative.
6161 East 75th Street, Indianapolis, IN 46250 USA |
855-365-2407 |
bestaccess.com
KAA1474 03-23
BEST is a trademark of dormakaba Holding © 2021 All rights reserved. BEST is a
member of the dormakaba Group, one of the top three providers for access and
security solutions, globally.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>