Winner CB2A30 Counterbalance Valve Instruction Manual
- June 13, 2024
- Winner
Table of Contents
Winner CB2A30 Counterbalance Valve
Product Information
- Ordering Code: CB-2A-X-Y-Z
- Product Name: Counterbalance Valve
- Weight: 0.3 kg
- Technical Data Max. Setting: 350 bar
- Rated Flow: 120 l/min
- Cavity-Tooling: 2A-3
- Installation Torque: 60 – 70 Nm
Product Usage Instructions
- Locate the counterbalance valve with the ordering code CB-2A-X-Y-Z.
- To reduce the setting and release the load, use a 4.0 Hex. Turn the screw and rotate it clockwise.
- To ensure proper torque, use a 14.0 Hex. Torque and tighten it between 6 – 7 Nm.
- The control option allows for maximum extension from the locating shoulder. (Z=L Control shown)
- Refer to the illustrations for detailed information on the pilot, load, and valve.
- The maximum setting pressure should be 1.3 times the maximum load-induced pressure. For example, if the max setting pressure is 350 bar, the load pressure should be lower than 270 bar.
- The pressure setting can be adjusted within the ranges mentioned under OPTIONS.
- The pilot ratio varies depending on the configuration:
- X: 10: 1
- Y: 4.5: 1
- Z (with the sealed pilot): 2.3: 1
- There are adjustment ranges available for specific purposes:
- J: 140 – 350 bar (210 bar Standard Setting)
- K: 70 – 175 bar (140 bar Standard Setting)
- C: 140 – 350 bar (210 bar Standard Setting)
- D: 70 – 175 bar (140 bar Standard Setting)
- Additional options include:
- Leakproof hex. socket screw
- Leakproof hex. socket screw with stainless steel external metal components
- Plastic tamper-resistant cover
- Please note that the illustrations and details provided are for reference only and are subject to change.
OVERVIEW
DIMENSION
SPRINGS
Y | SPRINGS |
---|
ADJUSTMENT RANGES(1.7 bar Cracking Pressure)
J| 140 – 350 bar (210 bar Standard Setting)|
K| 70 – 175 bar (140 bar Standard Setting)|
| SPECIAL PURPOSES(0.3 bar Cracking Pressure)
C| 140 – 350 bar (210 bar Standard Setting)|
D| 70 – 175 bar (140 bar Standard Setting)|
COUNTERBALANCE VALVE
TECHNICAL DATA
TECHNICAL DATA
Max. Setting:| 350| bar
Rated flow:| 120| l/min
Cavity-Tooling:| 2A-3|
Installation torque:| 60 – 70| Nm
Weight:| 0.3| kg
Pressure Setting:
The setting should be 1.3 times the maximum load-induced pressure. (We suggest
when the Max. setting pressure is 350 bar, the load pressure has to be lower
than 270 bar.)
PILOT RATIO
X | PILOT RATIO |
---|---|
30 | 10: 1 |
34 | 4.5: 1 |
3B | 2.3: 1 (with sealed pilot) |
3D | 4.5: 1 (with sealed pilot) |
OPTIONS
- Rev. 220303
- B. 121.202.E
Read User Manual Online (PDF format)