Winner CB2A30 Counterbalance Valve Instruction Manual

June 13, 2024
Winner

Winner CB2A30 Counterbalance Valve

Winner-CB2A30-Counterbalance-Valve-PRODUCT

Product Information

  • Ordering Code: CB-2A-X-Y-Z
  • Product Name: Counterbalance Valve
  • Weight: 0.3 kg
  • Technical Data Max. Setting: 350 bar
  • Rated Flow: 120 l/min
  • Cavity-Tooling: 2A-3
  • Installation Torque: 60 – 70 Nm

Product Usage Instructions

  1. Locate the counterbalance valve with the ordering code CB-2A-X-Y-Z.
  2. To reduce the setting and release the load, use a 4.0 Hex. Turn the screw and rotate it clockwise.
  3. To ensure proper torque, use a 14.0 Hex. Torque and tighten it between 6 – 7 Nm.
  4. The control option allows for maximum extension from the locating shoulder. (Z=L Control shown)
  5. Refer to the illustrations for detailed information on the pilot, load, and valve.
  6. The maximum setting pressure should be 1.3 times the maximum load-induced pressure. For example, if the max setting pressure is 350 bar, the load pressure should be lower than 270 bar.
  7. The pressure setting can be adjusted within the ranges mentioned under OPTIONS.
  8. The pilot ratio varies depending on the configuration:
    • X: 10: 1
    • Y: 4.5: 1
    • Z (with the sealed pilot): 2.3: 1
  9. There are adjustment ranges available for specific purposes:
    • J: 140 – 350 bar (210 bar Standard Setting)
    • K: 70 – 175 bar (140 bar Standard Setting)
    • C: 140 – 350 bar (210 bar Standard Setting)
    • D: 70 – 175 bar (140 bar Standard Setting)
  10. Additional options include:
    • Leakproof hex. socket screw
    • Leakproof hex. socket screw with stainless steel external metal components
    • Plastic tamper-resistant cover
  11. Please note that the illustrations and details provided are for reference only and are subject to change.

OVERVIEW

Winner-CB2A30-Counterbalance-Valve-FIG-1
\(1\)

DIMENSION

Winner-CB2A30-Counterbalance-Valve-FIG-1
\(2\)

SPRINGS

Y SPRINGS

ADJUSTMENT RANGES(1.7 bar Cracking Pressure)
J| 140 – 350 bar (210 bar Standard Setting)|
K| 70 – 175 bar (140 bar Standard Setting)|
 | SPECIAL PURPOSES(0.3 bar Cracking Pressure)
C| 140 – 350 bar (210 bar Standard Setting)|
D| 70 – 175 bar (140 bar Standard Setting)|

COUNTERBALANCE VALVE

TECHNICAL DATA

TECHNICAL DATA

Max. Setting:| 350| bar
Rated flow:| 120| l/min
Cavity-Tooling:| 2A-3|
Installation torque:| 60 – 70| Nm
Weight:| 0.3| kg
Pressure Setting:
The setting should be 1.3 times the maximum load-induced pressure. (We suggest when the Max. setting pressure is 350 bar, the load pressure has to be lower than 270 bar.)

PILOT RATIO

X PILOT RATIO
30 10: 1
34 4.5: 1
3B 2.3: 1 (with sealed pilot)
3D 4.5: 1 (with sealed pilot)

OPTIONS

  • Rev. 220303
  • B. 121.202.E