TELRAN 560430 Fingerprint Access Control User Manual
- June 4, 2024
- TELRAN
Table of Contents
- Introduction
- Features
- Technical Specifications
- Installation
- Wiring
- Diagram
- Sound and Light Indication
- Admin Menu
- new admin code #| Change admin code| 999999
- (Default admin code is
- press 8 or 10 digits card number # input card quantity #| Add a conductive
- Admin Operation
- Other Operation
- Documents / Resources
Fingerprint Access Control
User Manual
Introduction
The series of products is a new generation of multi-functional standalone
access control. It adopts a new ARM core 32-bit microprocessor design, which
is powerful, stable, and reliable. It contains reader mode and standalone
access control mode etc…
It’s widely applied to different occasions, such as offices, residential
communities, villas,s, etc…
Features
Feature | Specification |
---|---|
Card Type | Read 125KHz EM Card and HID Card (Optional) |
Read 13.56MHz Mifare card and CPU card (Optional)
Keypad Characteristic| Operate by infrared remote
Output Way| Contain reader mode, the transmission format could be adjusted by
users.
Access Way| Support multi-access ways: Card+Fingerprint, multi cards, or multi
fingerprints
Admin Card/Fingerprint| Support admin card/admin fingerprint
User Capacity| 10,000 card users and 300 fingerprint users
Unlocking Signal| Relay NO/NC/COM output
Technical Specifications
Operating Voltage: DC 12-24V | Standby Current: ≤ 35mA |
---|---|
Operating Current: ≤100mA | Operating Temperature: -20℃~60℃ |
Operating Humidity: 0%~95% | Electric lock signal relay contact current:≤1A |
Alarm signal MOS tube output current: ≤1A | Unlocking time: 0~300s adjustable |
Installation
- Remove the back cover from the keypad using the supplied special screw driver
- Drill 2 holes on the wall for the self-tapping screws and a hole for the cable
- Put the supplied rubber bungs into the two holes
- Fix the back cover firmly on the wall with 2 self-tapping screws
- Thread the cable through the cable hole
- Attach the keypad to the back cover. (as the following illustration)
Wiring
No. | Color | Marks | Description |
---|---|---|---|
1 | Green | D0 | Wiegand input (Wiegand output as reader mode) |
2 | White | D1 | Wiegand input (Wiegand output as reader mode) |
3 | Grey | ALARM | Alarm signal MOS tube drain output end (optional) |
4 | Yellow | OPEN/ BEEP | Exit button input end (Beeper input as reader mode) |
5 | Brown | D_IN/ LED | Door contact switch input end (LED input as reader mode) |
(optional)
6| Red| +12V| Positive power supply
7| Black| GND| Negative power supply
8| Blue| NO| Relay NO end
9| Purple| COM| Relay COM end
10| Orange| NC| Relay NC end
Diagram
6.1 Common Power Supply
Note: The door contact and alarm function are optional
6.2 Special Power Supply
Note: The door contact and alarm function are optional
6.3 Reader Mode
Sound and Light Indication
Operation Status | Light indicator | Buzzer |
---|---|---|
Stand by | Red | |
Operation successful | Green | Beep— |
Operation failed | Beep-Beep-Beep | |
Admin card enter programming | Beep-Beep | |
Admin card exit programming | Beep— | |
Press digital key | Beep | |
Press * key | Beep— | |
Read card under fingerprint + code mode | The red indicator flashes slowly | |
In process of reading multi-user card | The red indicator flashes slowly | |
Enter programming mode | The red indicator flashes slowly | |
Enter setting status | Orange | |
Unlocking | Green | |
Buzzer alarm | Red indicator flash quickly | Alarm |
Admin Menu
8.1 Standalone Mode Settings
Device Management
Enter programming| Menu| Operation steps| Description|
Default value
---|---|---|---|---
Press * Admin code # (Default admin code is “999999”)| **** 0| New admin code
new admin code #| Change admin code| 999999
1| 10001# Read card / Input a fingerprint twice *| * Set admin add card or
admin add fingerprint|
10002# Read card / Input a fingerprint twice | ** Set admin delete card or
admin delete fingerprint|
2| 10001# | Delete admin add card or admin add fingerprint|
10002# | Delete admin delete card or admin delete fingerprint|
3| 11 #| Standalone access control mode| 11
12 #| Relay toggle mode
13 #| Reader mode
( 26-58 ) #| Wiegand 26-58 bits output
8| 8 #| WIFI matching| Optional
Add and Delete Users
Enter programming| Menu| Operation steps| Description|
Default value
---|---|---|---|---
Press Admin code #
(Default admin code is “999999”)| 1| Read card/Input a fingerprint twice… |
Add card users or fingerprint users continuously| “…” means repeating the
previous operation, Press the key to exit.
Press 8 or 10 digits card number # … | Add card users by card number
Press ID number # Read card/ Input a fingerprint twice …| Add card users or
fingerprint users by specific ID number
Press ID number # Press 8 or 10 digits card number #… | Add card users by
specific ID number and card number
Delete users
2| Read card/Input a fingerprint once…| Delete card users by reading card /
Delete fingerprint users by inputting fingerprint| “…” means repeating the
previous operation, Press the key to exit.
Press 8 or 10 digits card number #… | Delete card users by card number
Press ID number # … | Delete users by ID number
0000#| Delete ALL users
Access Ways
Enter programming| Menu| Operation steps| Description|
Default value
---|---|---|---|---
Press *Admin code #(Default admin code is “999999”)| 3| 0 #| Entry by card or
fingerprint| 0
1 #| Entry by card + fingerprint
2-10 #| Entry by multi-card / multi-fingerprint
Advanced Settings
Enter programming| Menu| Operation steps| Description|
Default value
---|---|---|---|---
Press * Admin code
(Default admin code is
“999999”)| 4| (0-300) #| Door opening time range: 0-300S 0 equals to 50mS| 5
5| (0-99) #| Alarming time range: 0-99 min.| 0
6| Read user card, input the first fingerprint twice, input the second
fingerprint twice…*| Match fingerprints to a card (Maximum 2 fingerprints)|
7| Press ID number
press 8 or 10 digits card number # input card quantity #| Add a conductive
number card|
8| 0#| Normal working mode| 0
1#| The external alarm and built-in buzzer will work if wrong operations are
over 5 times.
2#| The device will be locked out for 10 min if wrong operations are over 5
times.
3#| Disable light indicator| 4
4#| Enable light indicator
5#| Disable buzzer| 6
6#| Enable buzzer
8.2 Reader Mode Settings
Enter programming| Menu| Operation steps| Description|
Default value
---|---|---|---|---
Press Admin code # (Default admin code is “999999”)| 0| New admin code #
Repeat new admin code #| Change admin code| 999999
1| 10001# Read card / Input a fingerprint twice | Set admin add card or admin
add fingerprint|
10002# Read card / Input a fingerprint twice | Set admin delete card or admin
delete fingerprint|
2| 10001# | Delete admin add card or admin add fingerprint|
10002# | Delete admin delete card or admin delete fingerprint|
1| Input a fingerprint twice… | Add fingerprint users continuously| “…” means
repeating the previous operation, Press the key to exit.
Press ID number # Input a fingerprint twice … | Add fingerprint users by
specific ID number
2| Input a fingerprint once… *| Delete fingerprint users
0000 #| Delete ALL users
3| (26-58) #| Wiegand 26-58 bits output| 26
5| (0-99) #| Alarming time range: 0-99 min| 0
9| (0-255) #| Device number| 0
Admin Operation
9.1 Add Users
Read admin add card / Input admin add a fingerprint, Read the 1st user card
/ Input the 1st fingerprint twice Read the 2nd user card / Input the 2nd
fingerprint twice …, Read admin add card / Input admin add fingerprint
Note: The admin add card/admin add fingerprint is used to add
card/fingerprint users continuously and quickly. When you read the admin add
card/input the admin add fingerprint at the first time, you will hear short
“BEEP” sounds twice and the indicator light turns orange, which means you have
entered into add user programming, when you read the admin add card/input the
admin add fingerprint at the second time, you will hear long “BEEP” sound once
and the indicator light turns red, it means you have exited the add user
programming.
9.2 Delete Users
Read admin delete card / Input admin delete fingerprint, Read the 1st user
card / Input the 1st fingerprint twice Read the 2nd user card/input the 2nd
fingerprint once…, Read admin delete card
Note: The admin delete card/admin delete fingerprint is used to delete
card/fingerprint users continuously and quickly. When you read the admin
delete card/admin delete fingerprint for the first time, you will hear short
“BEEP” sounds twice and the indicator light turns orange, which means you have
entered into delete user programming, when you read the admin delete
card/admin delete fingerprint at the second time, you will hear long “BEEP”
sound once, the indicator light turns red, it means you have exited the delete
user programming.
Other Operation
10.1 Remove Alarm
Read valid card or Input valid fingerprint or Press admin code#
Note: When the alarm is activated, users can remove the alarm by reading
a valid card or inputting a valid fingerprint, or pressing a valid admin code.
10.2 Reset to Factory Default
Users can reset to the factory default when the admin code is forgotten or the
default settings have been modified disorderedly, operations as below:
Power off, press and hold the exit button continuously, power on, and release
the exit button until hearing a beep sound twice, the admin code has been
reset to 999999, and factory default settings are successful.
Note: Registered user data won’t be deleted when reset to factory
default.
Fax: 03-5214524
office@telran.co.il
Phone: 03-5575110
www.telran.co.il
*Technical support 2023
p.n.560430**
Documents / Resources
|
TELRAN 560430 Fingerprint Access
Control
[pdf] User Manual
560430, Fingerprint Access Control, 560430 Fingerprint Access Control, Access
Control, Control
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>