XPOtool 61489 Bar Air Compressor User Manual
- June 4, 2024
- XPOtool
Table of Contents
XPOtool 61489 Bar Air Compressor
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical
data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities,
please contact us.
The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights re-served. The Wil Tec Wild anger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown. Even though, the Wil Tec Wild anger Technik GmbH has undergone biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.
- Send an e-mail to:
- service@wiltec.info
- or use our contact form:
- https://www.wiltec.de/contacts/
- The most recent version of this manual in various languages can be found in our online shop via:
- https://www.wiltec.de/docsearch
Our postal address is:
- Wil Tec Wild anger Technik GmbH
- Königsbenden 12
- 52249 Eschweiler
- Germany
To return orders for exchange, repair, or other purposes, please use the following address. Attention! To allow for a smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.
Returns Department
- Wil Tec Wild anger Technik GmbH
- Königsbenden 28
- 52249 Eschweiler
- E-mail: service@wiltec.info
- Tel: +49 2403 55592–0
- Fax: +49 2403 55592–15
Introduction
**** Thank you for purchasing this quality product. To minimize the risk of
injury we urge that our clients take some basic safety precautions when using
this device. Please read the operation instructions carefully and make sure
you have understood its content.
Keep these operation instructions safe.
Operating instructions
- Do not run the compressor for more than 10 min at a time. If you need to use it for longer, turn it off and let it rest for at least 10 min before starting it
- This compressor is not designed for inflating high pressure tires such as used on trucks, trailers or
- When running at more than 3 bar (45 psi), do not operate the tool for more than 7
- When using the compressor, never leave it unattended
Inflating tyres
- Move the vehicle so that the valve is in the bottom and its closest position to the ground. Place the air compressor next to the
- Plug the power cord into the cigarette lighter
- Place connector on valve stem and firmly push down, close the thumb
- When the desired pressure is reached, unplug the power
- Remove adaptor from tire valve, remove the power cord from the cigarette
- Always leave the thumb latch in the open position when storing the
Inflating other inflatable objects
- Select the suitable adaptor and insert it into the connector. Close the thumb
- Check the owner’s manual on the article to be inflated for the exact
- Insert the adaptor into the article to be
- Plug in the power cord into the cigarette lighter
- When the desired pressure is reached, unplug the power
- Remove the adaptor from the inflated Remove the adaptor from the connector. Remember to leave the thumb latch in opened position when storing it.
- Always check the item being inflated with the proper pressure Avoid excessive pressure on low pressure objects.
WARNING: Avoid over-inflating. Never exceed the recommended pressure. Items being over-inflated may burst and can cause serious injury.
Troubleshooting
Compressor does not start or blows fuses:
- Push the power plug firmly into the receptacle and twist it back and
- Check receptacle and plug terminals for dirt. Use a non-conductive probe and no fingers or metal to
- Check lighter fuse. This should be 15 A
- Check if the power cord is properly plugged
Compressor runs but does not inflate:
- Be sure the connector is on the valve stem as far as possible before closing the thumb
- Check article for leaks.
- Check hose for breaks and leaks at
Compressor runs slowly:
- Overheated from excessive Unplug the power cord and leave the compressor to cool down for at least 30 min.
- Voltage too low. Check condition of
CAUTION
- This compressor is capable of inflating to 17 bar (250 psi). To avoid over inflation the user must strictly follow operating instructions as required and described. Do not exceed the recommended pressure at any time. Never leave the unit unattended while operating it!
- The compressor should be kept out of reach of small
- Ensure that the connector is screwed into the valve stem until it looks firmly in
Disposal regulations
- EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
- All Wil Tec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
- The company Wil Tec Technik GmbH has been registered in the German registry EAR under the WEEE- registration number DE45283704.
Disposal of used electrical and electronic appliances (intended for use in the countries of the European Un-ion and other European countries with a separate col-lection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal house- hold waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local
community, municipal waste disposal facilities, or the store where you
purchased the article.
- Address:
- Wil Tec Wild anger Technik GmbH
- Königsbenden 12 / 28
- D-52249 Eschweiler
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>