Presentation
- The isolated channel module is an accessory only compatible with the SEFRAM Data Acquisition Systems: DAS220-240 / DAS30-50-60 / DAS1700-8460.
- This module allows the 16 logic channels (inputs / outputs) present on the DAS range to be deported via the Sub-D 25 connector. Equipped with optocouplers, it allows to increase the voltage input capacity of the logic channels (normally limited to 24V without this accessory), while bringing a comfort for the wiring on your equipments.
- The applications are multiple, such as the monitoring of logical state changes in an electrical cabinet (electrical relays, contacts..).
Figure 1.1: General presentation
-
Screw connector 3C (x12): see chapter 2.1 for use
-
Screw connector 3C (x12): see chapter 2.2 for use
These accessories can be provided as spare parts with the kit 984405600
Use
Logic channels inputs
First of all you have to connect the D-sub 25 wires cable between the isolated channel module and the DAS (4). Then choose the input on which to connect your signal according to the voltage allowed:
- 90V to 250V DC or AC between red and black socket (1)
- 10V to 48V DC or AC between pins 1 and 3 of the green terminal block (2)
- Below 10V DC or AC between pin 1 and 2 of the green terminal block (3)
All inputs are isolated from each other and from ground.
Figure 2.1: Maximal voltage input allowed
Power supplies and alarms outputs
The 10-contact terminal block is not isolated. The grounds are connected together. It allows 3,3V, 5V or 12V voltage supplies of an external circuit (sensor or other) or to output the TTL 0-5V signals (alarms) of the Data Acquisition System. The maximum current output is 200 mA.
Figure 2.2: Power supplies and alarms outputs
The different pins are arranged as follows:
Pin number | Type | Signal | Devices |
---|---|---|---|
1 | Ground | – | DAS220/240 : DAS30/50/60 ; DAS1700/8460 |
5 | – | DAS220/240 ; DAS30/50/60 ; DAS1700/8460 | |
10 | – | DAS220/240 ; DAS30/50/60 ; DAS1700/8460 | |
2 | Supply | 3.3V | DAS220/240 ; DAS30/50/60 ; DAS1700/8460 |
3 | Supply | 5V | DAS220/240 ; DAS30/50/60 ; DAS1700/8460 |
4 | Supply | 12V | DAS220/240 ; DAS30/50/60 ; DAS1700/8460 |
6 | Alarm A | Dry contact terminal 1 | DAS1700/8460 |
Alarm C | TTL 5V | DAS220/240 ; DAS60 | |
7 | Alarm A | Dry contact terminal 2 | DAS1700/8460 |
Alarm D | TTL 5V | DAS220/240 ; DAS60 | |
8 | Alarm B | TTL 5V | DAS1700/8460 |
Alarm A | DAS220/240 ; DAS30/50/60 | ||
9 | Alarm C | TTL 5V | DAS1700/8460 |
Alarm B | DAS220/240 ; DAS30/50/60 |
Figure 2.3: Description of the power supplies and alarms pins
Specifications
Specifications of the logic channel inputs
Caution: Only use accessories with a security category at least equal to the input card.
From 0 to 250V:
- Isolated banana plug between red and black socket
- Maximal voltage allowed: 250V DC or AC
- Typical switching threshold (AC or DC): 48V
- Frequency: 45 to 440Hz
- Low threshold not detected (AC or DC): 0 to 10V
- High threshold detected (AC or DC): 60V to 250V
- Isolation: 250V=~ between channel and ground
From 0 to 48V:
- By screw terminal between pin 1 and 3 of the terminal block
- Maximal voltage allowed: 48V DC or AC
- Frequency: 45 to 440Hz
- Typical switching threshold (AC or DC): 9V
- Low threshold not detected (AC or DC): 0 to 2V
- High threshold detected (AC or DC): 10 to 48V
- Isolation: 50V=~ entre channel and ground
From 0 to 10V:
- By screw terminal between pin 1 and 2 of the terminal block
- Maximal voltage allowed: 10V DC or AC
- Frequency: 45 to 440Hz
- Typical switching threshold (AC or DC): 2,2V
- Low threshold not detected (AC or DC): 0 to 1V
- High threshold detected (AC or DC): 3 to 10V
- Isolation: 50V=~ between channel and ground
Response time
To detect AC, the signal of the logic channels is rectified and filtered.
- Typical delay for a rising signal: 10ms
- Typical delay for a descending signal: 50ms
Safety, insulation class, installation category
- Complies with standard EN61010-1 and EN61010-2-030
- Pollution degree: 2
- Safety: CAT II 250V
Caution: special precautions must be taken to maintain product compliance, including the use of cords corresponding to the measurement input category.
Environmental conditions
Climate conditions
- Operating temperature: 0 to 40°C
- Maximum relative humidity: 80 % non-condensing
- Storage temperature: -20 to 60°C
- Maximum altitude: 2000m
Power supply
- Power is supplied by the recorder via the 25-pin SUB-D connector.
- Caution: use only the supplied cable and a SEFRAM device from the data acquisition range. Refer to the device’s manual.
Dimensions and weight
- Height: 160mm
- Width: 250mm
- Depth: 37mm
- Masse: 620g
Conditions
Warranty
Your instrument is warranted for two years against defects in materials and
workmanship. This warranty applies from the date of delivery and ends 730
calendar days later. If the unit is covered by a warranty agreement, the
warranty agreement supplements, supersedes, or replaces the warranty terms
listed above. The warranty
conditions applicable by SEFRAM are available on the website
www.sefram.com.
The terms and conditions of this warranty take precedence over this summary.
This warranty does not cover defects resulting from abnormal use, handling
errors or storage conditions outside the defined range. In the event of a
warranty claim, the user must return the device concerned to our factory at
his own expense :
SEFRAM Instruments SAS Service Après-vente 32, Rue Edouard MARTEL BP 55
42009 SAINT-ETIENNE CEDEX 2 and write a a description of the fault found
with the equipment.The accessories delivered as standard with the device
(cords, plugs…) are guaranteed for 3 months against manufacturing defects.
Wear and tear, accidental breakage or breakage resulting from a shock or
abnormal use are not guaranteed. The time remaining to be covered if the
device is guaranteed – If the warranty of the device < 90 days, the replaced
part is guaranteed 90 days
Any replacement part becomes the property of the user and the exchanged parts
become the property of SEFRAM. In case of insurance coverage, the product
becomes the property of the latter at its exclusive request. Otherwise it
remains the property of the user. The warranty applies only to equipment
manufactured and supplied by SEFRAM. Any intervention or modification made by
the user or by a third party without prior authorization from the company will
result in the loss of the benefit of the warranty. The user is responsible for
the return of the equipment to our premises. He must therefore ensure that the
packaging will allow proper protection during transport. He must take out the
necessary insurance for the transport at his own expense. SEFRAM reserves the
right to refuse a poorly packed product, and not to propose a repair if the
breakage is due to transport.
What to do in case of dysfunction:
In case of dysfunctions or operating problems, please contact SEFRAM
Instruments & Systems technical support. A technician will take your call and
give you all the necessary information to solve your problem.
Advice or technical assistance:
SEFRAM Instruments & Systems is committed to helping you by phone to use your
device by calling 04 77 59 01 01 or by email at
support@sefram.com
What to do in case of a breakdown?
Please return your equipment with the RMA document previously registered on
our website to:
www.sefram.com/services.html then click
on Return Material Authorization (RMA).
For any further information you can contact the after-sales service by phone
at 04 77 59 01 01 or by mail at
services@sefram.com
Metrology
You are in possession of a measuring instrument for which the metrological conditions are defined in the specifications of this manual. The climatic and environmental conditions limit the specifications of your Instrument. SEFRAM checks the characteristics of each instrument individually on an automatic rack during its manufacture. Adjustment and verification are guaranteed within the framework of ISO9001 certification by measuring instruments connected to COFRAC (or equivalent in ILAC reciprocity). When a product returns to SEFRAM, a maximum service is ensured with internal upgrading according to the necessary evolutions and software upgrading. In case of deviation from the specifications, your instrument will be adjusted to its original characteristics.
Packaging
The packaging of this product is entirely recyclable. It is designed to transport your instrument in the best conditions. We draw your attention to the fact that the original packaging must be over-packed if it is used for transport by air, road or mail. We recommend that you keep the original packaging for any transport.
Isolated logic channel module
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>