Rheem Classic Series RP14 Heat Pump
Product Information
The product is a heat pump with the model number RP14. It is important to properly size and install the equipment to achieve optimal performance. The heat pump is designed to be matched with appropriate coil components to meet Energy Star requirements. For more details, you can ask your contractor or visit the Energy Star website at www.energystar.gov.
Product Usage Instructions
- Ensure that the heat pump is properly sized and installed according to the instructions provided by your contractor.
- Match the heat pump with appropriate coil components to meet Energy Star requirements.
- For maintenance and cleaning purposes, refer to the unit dimensions and clearances provided in the user manual.
- Refer to the control wiring diagram for proper connection and installation of the heat pump.
- Make sure to use the correct refrigerant line size as specified in the user manual.
- Refer to the performance data for information on the heat pump’s efficiency and output.
- Read and understand the limited warranty terms provided in the user manual.
- To access internal components or perform coil cleaning, follow the instructions for removing the fasteners and louver panels.
- For service calls or troubleshooting, refer to the gauge ports and other accessible parts of the heat pump.
Note: It is recommended to consult a professional HVAC technician or contractor for proper installation, maintenance, and servicing of the heat pump.
Rheem Classic® Series RP14
- Efficiencies: 14 SEER/11.5 EER 8.2 HSPF
- Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW]
- Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW]
Standard Feature Table
Standard Features
Feature| RP1418CJ1NA| RP1424AJ1NA| RP1430AJ1NA
Capacity| 18| 24| 30
R-410A Refrigerant| Y| Y| Y
SEER| 14| 14| 14
SEER2| 14| 14| 14
EER| 11.5| 11.5| 11.5
EER2| 11.5| 11.5| 11.5
PrimaryCompressorType| Scroll| Scroll| Scroll
AlternateCompressorType| 0| 0| 0
FieldInstalledFilterDrier| Y| Y| Y
FrontSeatingServiceValves| Y| Y| Y
InternalPressureReliefValve| Y| Y| Y
InternalThermalOverload| Y| Y| Y
LongLinecapability| Y| Y| Y
LowAmbientCapabilityWithKit| Y| Y| Y
ThreeFourFiveExpandedValveSpace| Y| Y| Y
CompositeBasepan| Y| Y| Y
TwoScrewControlBoxAccess| Y| Y| Y
FifteenInchAccessToInternalComponents| Y| Y| Y
QuickReleaseLouverPanelDesign| Y| Y| Y
NoFastenersToRemoveAlongBottom| Y| Y| Y
OptimizedVenturiAirflow| Y| Y| Y
SingleRowCondenserCoil| Y| Y| Y
PowderCoatedPaint| Y| Y| Y
RustResistantScrews| Y| Y| Y
QrCode| Y| Y| Y
ExternalGaugePorts| Y| Y| Y
ServiceTrays| Y| Y| Y
Feature| RP1436AC1NA| RP1436AD1NA| RP1436AJ1NA
---|---|---|---
Capacity| 36| 36| 36
R-410A Refrigerant| Y| Y| Y
SEER| 14| 14| 14
SEER2| 14| 14| 14
EER| 11.5| 11.5| 11.5
EER2| 11.5| 11.5| 11.5
PrimaryCompressorType| Scroll| Scroll| Scroll
AlternateCompressorType| 0| 0| 0
FieldInstalledFilterDrier| Y| Y| Y
FrontSeatingServiceValves| Y| Y| Y
InternalPressureReliefValve| Y| Y| Y
InternalThermalOverload| Y| Y| Y
LongLinecapability| Y| Y| Y
LowAmbientCapabilityWithKit| Y| Y| Y
ThreeFourFiveExpandedValveSpace| Y| Y| Y
CompositeBasepan| Y| Y| Y
TwoScrewControlBoxAccess| Y| Y| Y
FifteenInchAccessToInternalComponents| Y| Y| Y
QuickReleaseLouverPanelDesign| Y| Y| Y
NoFastenersToRemoveAlongBottom| Y| Y| Y
OptimizedVenturiAirflow| Y| Y| Y
SingleRowCondenserCoil| Y| Y| Y
PowderCoatedPaint| Y| Y| Y
RustResistantScrews| Y| Y| Y
QrCode| Y| Y| Y
ExternalGaugePorts| Y| Y| Y
ServiceTrays| Y| Y| Y
Feature| RP1442CC1NA| RP1442CD1NA| RP1442CJ1NA
---|---|---|---
Capacity| 42| 42| 42
R-410A Refrigerant| Y| Y| Y
SEER| 14| 14| 14
SEER2| 14| 14| 14
EER| 11.5| 11.5| 11.5
EER2| 11.5| 11.5| 11.5
PrimaryCompressorType| Scroll| Scroll| Scroll
AlternateCompressorType| 0| 0| 0
FieldInstalledFilterDrier| Y| Y| Y
FrontSeatingServiceValves| Y| Y| Y
InternalPressureReliefValve| Y| Y| Y
InternalThermalOverload| Y| Y| Y
LongLinecapability| Y| Y| Y
LowAmbientCapabilityWithKit| Y| Y| Y
ThreeFourFiveExpandedValveSpace| Y| Y| Y
CompositeBasepan| Y| Y| Y
TwoScrewControlBoxAccess| Y| Y| Y
FifteenInchAccessToInternalComponents| Y| Y| Y
QuickReleaseLouverPanelDesign| Y| Y| Y
NoFastenersToRemoveAlongBottom| Y| Y| Y
OptimizedVenturiAirflow| Y| Y| Y
SingleRowCondenserCoil| Y| Y| Y
PowderCoatedPaint| Y| Y| Y
RustResistantScrews| Y| Y| Y
QrCode| Y| Y| Y
ExternalGaugePorts| Y| Y| Y
ServiceTrays| Y| Y| Y
Feature| RP1448AC1NA| RP1448AD1NA| RP1460BC1NA
---|---|---|---
Capacity| 48| 48| 60
R-410A Refrigerant| Y| Y| Y
SEER| 14| 14| 14
SEER2| 14| 14| 14
EER| 11.5| 11.5| 11.5
EER2| 11.5| 11.5| 11.5
PrimaryCompressorType| Scroll| Scroll| Scroll
AlternateCompressorType| 0| 0| 0
FieldInstalledFilterDrier| Y| Y| Y
FrontSeatingServiceValves| Y| Y| Y
InternalPressureReliefValve| Y| Y| Y
InternalThermalOverload| Y| Y| Y
LongLinecapability| Y| Y| Y
LowAmbientCapabilityWithKit| Y| Y| Y
ThreeFourFiveExpandedValveSpace| Y| Y| Y
CompositeBasepan| Y| Y| Y
TwoScrewControlBoxAccess| Y| Y| Y
FifteenInchAccessToInternalComponents| Y| Y| Y
QuickReleaseLouverPanelDesign| Y| Y| Y
NoFastenersToRemoveAlongBottom| Y| Y| Y
OptimizedVenturiAirflow| Y| Y| Y
SingleRowCondenserCoil| Y| Y| Y
PowderCoatedPaint| Y| Y| Y
RustResistantScrews| Y| Y| Y
QrCode| Y| Y| Y
ExternalGaugePorts| Y| Y| Y
ServiceTrays| Y| Y| Y
Feature| RP1460BD1NA| RP1460BJ1NA
---|---|---
Capacity| 60| 60
R-410A Refrigerant| Y| Y
SEER| 14| 14
SEER2| 14| 14
EER| 11.5| 11.5
EER2| 11.5| 11.5
PrimaryCompressorType| Scroll| Scroll
AlternateCompressorType| 0| 0
FieldInstalledFilterDrier| Y| Y
FrontSeatingServiceValves| Y| Y
InternalPressureReliefValve| Y| Y
InternalThermalOverload| Y| Y
LongLinecapability| Y| Y
LowAmbientCapabilityWithKit| Y| Y
ThreeFourFiveExpandedValveSpace| Y| Y
CompositeBasepan| Y| Y
TwoScrewControlBoxAccess| Y| Y
FifteenInchAccessToInternalComponents| Y| Y
QuickReleaseLouverPanelDesign| Y| Y
NoFastenersToRemoveAlongBottom| Y| Y
OptimizedVenturiAirflow| Y| Y
SingleRowCondenserCoil| Y| Y
PowderCoatedPaint| Y| Y
RustResistantScrews| Y| Y
QrCode| Y| Y
ExternalGaugePorts| Y| Y
ServiceTrays| Y| Y
Features and Benefits
-
New composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
-
Improved tubing design – reduces vibration and stress, making unit quieter and reducing opportunity for leaks
-
Optimized defrost characteristics – decrease defrosting and provide better home comfort
-
Powder coat paint system – for a long lasting professional finish Optimized reversing valve sizing – improves shifting performance for quieter unit operation and increased life of the system
-
Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
-
Scroll compressor – a sound abating feature added to the compressor significantly reduces noise when system transitions in and out of defrost mode
-
Modern cabinet aesthetics – increased curb appeal with visually appealing design
-
Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
-
Optimized fan orifice – optimizes airflow and reduces unit sound Rust resistant screws – confirmed through 1500-hour salt spray testing
-
Rust resistant screws – confirmed through 1500-hour salt spray testing
-
PlusOne™ Expanded Valve Space – 3″-4″-5″ service valve space –provides a minimum working area of 27-square inches for easier access
-
Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into the base
-
PlusOne™ Triple Service Access – 15″ wide, industry leading corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly -
Diagnostic service window with two-fastener opening – provides access to the TXV valves and the heat pump reversing valve before opening the unit.
-
External gauge port access – allows easy connection of “low-loss” gauge ports
-
Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain “out of the box” performance
-
35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal
-
Service trays – hold fasteners or caps during service calls QR code – provides technical information on demand for faster service calls
-
Fan motor harness with extra-long wires – allows unit top to be removed without disconnecting fan wire
Air Conditioners
Available SKUs
Available Models
Description
RP1460BD1NA
RP1436AC1NA
RP1448AC1NA
RP1424AJ1NA
RP1436AD1NA
RP1448AD1NA
RP1460BC1NA
RP1460BJ1NA
RP1430AJ1NA
RP1436AJ1NA
RP1418CJ1NA
RP1442CJ1NA
RP1442CD1NA
RP1442CC1NA
General Data
Electrical Data
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of fuse.
- Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
General Data
Electrical Data
General Data
Electrical Data
General Data
Electrical Data
General Data
Electrical Data
Accessories
RP1418CJ1NA
Accessory Type| Part Number
RP1424AJ1NA
Accessory Type| Part Number
RP1430AJ1NA
Accessory Type| Part Number
RP1436AC1NA
Accessory Type| Part Number
RP1436AD1NA
Accessory Type| Part Number
RP1436AJ1NA
Accessory Type| Part Number
RP1442CC1NA
Accessory Type| Part Number
RP1442CD1NA
Accessory Type| Part Number
RP1442CJ1NA
Accessory Type| Part Number
RP1448AC1NA
Accessory Type| Part Number
RP1448AD1NA
Accessory Type| Part Number
RP1460BC1NA
Accessory Type| Part Number
RP1460BD1NA
Accessory Type| Part Number
RP1460BJ1NA
Accessory Type| Part Number
Weighted Sound Power Level (dBA)
Model No.| ****
RP1418CJ1NA
| ****
RP1424AJ1NA
| ****
RP1430AJ1NA
---|---|---|---
Standard Rating| 76| 75| 77
TYPICAL OCTAVE BAND
SPECTRUM (dBA without tone adjustment)
| 125| 53.7| 55.9| 60.8
250| 61.8| 59.8| 60.5
500| 66.2| 64.8| 65.4
1000| 66.8| 66.1| 66.9
2000| 62.9| 62.3| 63.9
4000| 58| 57.7| 59.9
8000| 52| 53| 53.1
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Model No.| ****
RP1436AC1NA
| ****
RP1436AD1NA
| ****
RP1436AJ1NA
---|---|---|---
Standard Rating| 74| 74| 74
TYPICAL OCTAVE BAND
SPECTRUM (dBA without tone adjustment)
| 125| 50.5| 50.5| 50.5
250| 58| 58| 58
500| 63.5| 63.5| 63.5
1000| 65.1| 65.1| 65.1
2000| 61.2| 61.2| 61.2
4000| 56.1| 56.1| 56.1
8000| 53.7| 53.7| 53.7
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Model No.| ****
RP1442CC1NA
| ****
RP1442CD1NA
| ****
RP1442CJ1NA
---|---|---|---
Standard Rating| 74| 74| 74
TYPICAL OCTAVE BAND
SPECTRUM (dBA without tone adjustment)
| 125| 47.6| 47.6| 47.6
250| 52.5| 52.5| 52.5
500| 61.6| 61.6| 61.6
1000| 63.5| 63.5| 63.5
2000| 58.3| 58.3| 58.3
4000| 54.8| 54.8| 54.8
8000| 50.7| 50.7| 50.7
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Model No.| ****
RP1442CC1NA
| ****
RP1442CD1NA
| ****
RP1442CJ1NA
---|---|---|---
Standard Rating| 74| 74| 74
TYPICAL OCTAVE BAND
SPECTRUM (dBA without tone adjustment)
| 125| 47.6| 47.6| 47.6
250| 52.5| 52.5| 52.5
500| 61.6| 61.6| 61.6
1000| 63.5| 63.5| 63.5
2000| 58.3| 58.3| 58.3
4000| 54.8| 54.8| 54.8
8000| 50.7| 50.7| 50.7
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Model No.| ****
RP1460BJ1NA
---|---
Standard Rating| 74
TYPICAL OCTAVE BAND SPECTRUM (dBA without
tone adjustment)
| 125| 58.9
250| 55.7
500| 63.4
1000| 63.3
2000| 61.5
4000| 58.6
8000| 56.4
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
Model No. | RP1418CJ1NA | RP1424AJ1NA | RP1430AJ1NA |
---|
OPERATING
H (Height)| INCHES| 25| 26.25| 26.25
L (Length)| INCHES| 29.75| 29.75| 29.75
W (Width)| INCHES| 29.75| 29.75| 29.75
SHIPPING
H (Height)| INCHES| 27.9| 27.9| 27.9
L (Length)| INCHES| 33.25| 33.25| 33.25
W (Width)| INCHES| 33| 33| 33
Model No.| RP1436AC1NA| RP1436AD1NA| RP1436AJ1NA
---|---|---|---
OPERATING
H (Height)| INCHES| 27| 27| 27.38
L (Length)| INCHES| 33.75| 33.75| 33.75
W (Width)| INCHES| 33.75| 33.75| 33.75
SHIPPING
H (Height)| INCHES| 30.08| 30.08| 30.08
L (Length)| INCHES| 37.64| 37.64| 37.64
W (Width)| INCHES| 37.56| 37.56| 37.56
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 – in. wc.
- Minimum outdoor operation air temperature for cooling mode without low ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C)
- For reliable operation, unit should be level in all horizontal planes.
- Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory – supplied filter drier must be installed.
Unit Dimensions
Model No. | RP1442CC1NA | RP1442CD1NA | RP1442CJ1NA |
---|
OPERATING
H (Height)| INCHES| 35| 35| 35
L (Length)| INCHES| 33.75| 33.75| 33.75
W (Width)| INCHES| 33.75| 33.75| 33.75
SHIPPING
H (Height)| INCHES| 38.35| 38.35| 38.35
L (Length)| INCHES| 37.64| 37.64| 37.64
W (Width)| INCHES| 37.56| 37.56| 37.56
Model No.| RP1448AC1NA| RP1448AD1NA| RP1460BC1NA
---|---|---|---
OPERATING
H (Height)| INCHES| 35| 35| 45
L (Length)| INCHES| 33.75| 33.75| 35.75
W (Width)| INCHES| 33.75| 33.75| 35.75
SHIPPING
H (Height)| INCHES| 38.35| 38.35| 48.18
L (Length)| INCHES| 37.64| 37.64| 39.37
W (Width)| INCHES| 37.56| 37.56| 39.64
Model No.| RP1460BD1NA| RP1460BJ1NA
---|---|---
OPERATING
H (Height)| INCHES| 0| 45
L (Length)| INCHES| 0| 35.75
W (Width)| INCHES| 0| 35.75
SHIPPING
H (Height)| INCHES| 48.18| 48.18
L (Length)| INCHES| 39.37| 39.37
W (Width)| INCHES| 39.64| 39.64
CLEARANCES
Control Wiring
NOTES:
- Jumper “E” to “W2” to transfer control of supplemental heat to 1st stage when the emergency heat switch is on.
- This wire turns on heat for defrost, omit for most economical operation.
- Wire with colored tracing stripe.
Refrigerant Line Size Information
Performance Data
Performance Data @ AHRI Standard Conditions – Cooling
Designated Test Combinations (DTC)
Outdoor Unit| Indoor Coil| Total Capacity
BTU/H [kW]
| Net Sensible
BTU/H [kW]
| Net Latent BTU/H
[kW]
| SEER| EER| Inddor CFM [L/s]
RP1418CJ1NA| TZHSLTST2417| 17100 [5]| 13680 [4]| 3420 [1]| 15| 12.5| 650
[null]
RP1424AJ1NA| TZHSLTST2417| 22800 [6.6]| 18240 [5.3]| 4560 [1.3]| 14| 11| 825
[null]
RP1430AJ1NA| TZHSLTST3617| 28600 [8.3]| 22880 [6.6]| 5720 [1.7]| 14| 11| 1075
[null]
RP1436AC1NA| TZHSLTST3617| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 14| 11| 1200
[null]
RP1436AD1NA| TZHSLTST3617| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 14| 11| 1200
[null]
RP1436AJ1NA| TZHSLTST3617| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 14| 11| 1200
[null]
RP1442CC1NA| TZHSLTST4821| 40000 [11.6]| 32000 [9.3]| 8000 [2.3]| 14| 11| 1375
[null]
RP1442CD1NA| TZHSLTST4821| 40000 [11.6]| 32000 [9.3]| 8000 [2.3]| 14| 11| 1375
[null]
RP1442CJ1NA| TZHSLTST4821| 40000 [11.6]| 32000 [9.3]| 8000 [2.3]| 14| 11| 1375
[null]
RP1448AC1NA| TZHSLTST4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 14| 11|
1550 [null]
RP1448AD1NA| TZHSLTST4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 14| 11|
1550 [null]
RP1460BC1NA| TZHSLTST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 15| 12.5|
1800 [null]
RP1460BD1NA| TZHSLTST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 15| 12.5|
1800 [null]
RP1460BJ1NA| TZHSLTST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 15| 12.5|
1800 [null]
Note: Additional ratings and system match ups can be accessed on MyRheem.com at: https://my.rheem.com/static/private/ahriresidential.html
Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org
Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required)
Ten (10) Years