dacor ERV3015 RENAISSANCE Slim Chassis Downdraft Vents User Guide

June 13, 2024
dacor

ERV3015 RENAISSANCE Slim Chassis Downdraft Vents

Product Information

The downdraft vents mentioned in the user manual are part of the
Dacor Renaissance Slim Chassis series. The models include ERV3015,
ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, and PRV48. The
dimensions and specifications vary depending on the model.

The vents are designed to be installed alongside approved Dacor
appliances and must be installed in accordance with the provided
installation instructions. It is important to comply with governing
codes and ordinances during planning and installation. Local
building codes may also require the use of makeup air systems.

Model Dimensions

Model Front View Width Front View Height Side View Depth
ERV3015 30″ (76.2 cm) 27 3/8″ (69.5 cm)
ERV3615 36″ (91.4 cm) 33 3/8″ (84.8 cm)
ERV48 48″ (121.9 cm) 43 3/8″ (110.2 cm)
PRV30 30″ (76.2 cm) 27 3/8″ (69.5 cm)
PRV36 36″ (91.4 cm) 33 3/8″ (84.8 cm)
PRV48 48″ (121.9 cm) 43 3/8″ (110.2 cm)

Circuit Requirement

The downdraft vents require a three-prong electrical outlet
connected to 120 Vac, 60 Hz, and a dedicated circuit. The circuit
should be grounded and have a capacity of 15 Amp.

Important Notes

  • The maximum installed height of the downdraft vents should not
    exceed the maximum specified countertop height of the cooking
    appliance.

  • Only install these downdraft vents with approved Dacor
    appliances. Refer to the planning guide for the specific appliance
    for proper applications and cutout information.

  • The downdraft vents must be installed in conjunction with a
    single Dacor approved blower. Refer to page 4/7 of the user manual
    for a list of approved blowers.

  • Consult a qualified HVAC specialist to ensure compliance with
    local building codes and optimal performance, especially regarding
    the use of makeup air systems.

All specifications are subject to change without notice.

For more information and support, visit the Dacor website at
www.dacor.com or contact their
customer service at 800-793-0093.

You can also find the user manual at https://manual-hub.com/.

Product Usage Instructions

To ensure proper usage of the downdraft vents, follow these
instructions:

  1. Before installation, carefully read and understand the provided
    installation instructions.

  2. Comply with all governing codes and ordinances during planning
    and installation. Contact your local building department for
    further information.

  3. Install the downdraft vents only with approved Dacor
    appliances. Refer to the planning guide for the specific appliance
    for proper applications and cutout information.

  4. Ensure that the maximum installed height of the downdraft vents
    does not exceed the maximum specified countertop height of the
    cooking appliance.

  5. Install the downdraft vents in conjunction with a single Dacor
    approved blower. Refer to page 4/7 of the user manual for a list of
    approved blowers.

  6. Connect the downdraft vents to a three-prong electrical outlet
    that is connected to 120 Vac, 60 Hz, and has a capacity of 15 Amp.
    The circuit should be grounded and dedicated to the vent.

  7. If required by local building codes, consult a qualified HVAC
    specialist to determine the need for makeup air systems and design
    the system accordingly for optimal performance.

For any further assistance or information, refer to the provided
user manual or contact Dacor customer service.

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 1/7

Renaissance® Slim Chassis

PLANNING

Downdraft Vents

GUIDE

DImENSIoNS – moDELS ERV3015, ERV3615

5/16″ (8 mm) thick stiffener across back

2 3/16″ (5.6 cm)
2 1/8″ (5.4 cm)

3″ (7.6 cm)

3/16″ (5 mm)

1 15/16″ (4.9 cm)

2 9/16″*
(6.5 cm)

·

Top cap with

vent down

·

9/16″ (1.4 cm)

  • Total chassis depth with optional CABP3 blower installed is 10 3/8″ (26.3 cm).

warning
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances: ±1/16″ (±1.6 mm) unless otherwise stated

A

Vent shown in raised position

15″ (38.1 cm)

2 1/8″ (5.4 cm)

3/8″ (1.0 cm)

Top cap – side view

20″ (50.8 cm)
3 3/4″ (9.5 cm)
1 1/8″ (2.9 cm)

30 1/4″ (76.8 cm)

30″ (76.2 cm)

to

37 1/4″

(94.6 cm)

B
6″ (15.2 cm)
Motor cover Front of unit

Product data label
28″ 3 prong grounded power cord

SIDE VIEw

Model no.

a

B

ERV3015

30″ (76.2 cm)

27 3/8″ (69.5 cm)

ERV3615

36″ (91.4 cm)

33 3/8″ 84.8 cm)

** Includes power supply requirements for blower

Circuit requirement**
Three prong electrical outlet connected to 120 Vac, 60 Hz., 15 Amp. grounded,
dedicated, circuit

Adjustable anchor legs
FRoNt VIEw
nOTES:
1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2. install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3. This appliance must be install in conjunction with a single, Dacor approved blower. See page 4/7 for approved blowers.
4. Local building codes may require the use of makeup air systems. Consult a qualified HVaC specialist when designing the system for the requirements in your area and to assure optimal performance.

All specifications subject to change without notice.

www.dacor.com

Phone: 800-793-0093

Search

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 2/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

DImENSIoNS – moDELS ERV48, PRV30, PRV36, PRV48

warning
· Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
· This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances: ±1/16″ (±1.6 mm) unless otherwise stated

3/8″ (1.0 cm)

2 1/8″ (5.4 cm)

A

ERV top cap – side view

7/16″ (1.1 cm)
2 1/8″ (5.4 cm)
PRV top cap – side view

B

SIDE VIEw

FRoNt VIEw

Model no.

a

B

Circuit requirement**

PRV30 PRV36 PRV46 ERV48

30″ (76.2 cm)
36″ (91.4 cm)
46″ (116.8 cm)
48″ (121.9 cm)

27 3/8″ (69.5 cm)
33 3/8″ 84.8 cm)
43 3/8″ (110.2 cm)
43 3/8″ (110.2 cm)

Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded,
dedicated, circuit

** Includes power supply requirements for external blower

nOTES:
1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2. install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3. This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers.
4. Local building codes may require the use of makeup air systems. Consult a qualified HVaC specialist when designing the system for the requirements in your area and to assure optimal performance.

All specifications subject to change without notice.

www.dacor.com

Phone: 800-793-0093

Search

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 3/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

DImENSIoNS – moDELS ERV36-ER, ERV48-ER

5/16″ (8 mm) thick stiffener
across back
2 1/2″ (6.4 cm)

1/4″ (6 mm)
2 13/16″ (7.1 cm)
Top cap with vent down

1 15/16″ (4.9 cm)

2 9/16″ (6.5 cm)

warning
· Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
· This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances: +/- 1/16″ (+/- 1.6 mm) unless otherwise stated

Model number ERV36-ER ERV48-ER

a 36″ (91.4 cm) 48″ (121.9 cm)

B 33 3/8″ (84.8 cm) 43 3/8″ (110.2 cm)

nOTE: See the appliance planning guide page for cutout dimensions

A

Vent shown in raised position

10″ (25.4 cm)

18 5/8″ (47.3 cm)
3 3/4″ (9.5 cm)
1″ (2.5 cm)

30 ¼” (76.8 cm)

30″ (76.2 cm)

to

37 ¼”

(94.6 cm)

B
6″ (15.2 cm)
Motor cover
Front of unit

Adjustable anchor legs
nOTES:
1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2. install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3. This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers.
4. Local building codes may require the use of makeup air systems. Consult a qualified HVaC specialist when designing the system for the requirements in your area and to assure optimal performance.

Product data label
28″ 3 prong grounded power cord
Circuit requirement (all models)* Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit

  • Includes power supply requirements for external blower.

All specifications subject to change without notice.

www.dacor.com

Search

Phone: 800-793-0093

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 4/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

Duct System Layouts and approved Blowers
iMPOrTanT: Do not install more than one blower with this appliance.

Blower Model CABP31 ILHSF8 ILHSF10 REMP3 REMP16

aPPrOVED DaCOr BLOwErS

Blower rating 600 CFM2 600 CFM2 1100 CFM2 600 CFM2 1000 CFM2

Compatible with ERV30153, ERV36153 All Dacor ERV, PRV Series Models All Dacor ERV, PRV Series Models All Dacor ERV, PRV Series Models All Dacor ERV, PRV Series Models

1 iMPOrTanT: Due to a lack of clearance, do not use a CABP3 blower if a range or wall oven is to be installed in front of the downdraft vent.
2 Nominal rating at zero inches static pressure, see the blower panning guide page for actual blower ratings.
3 Revision B and later units only. Installation of blower model CABP3 requires Dacor adapter kit # AERVCAB.

The CABP3 blower assembly is mounted to the front of the downdraft vent with the exhaust pointing in the desired direction.
With ILHSF and REMP blowers, the downdraft vent can be configured to exhaust through the back, the bottom or either side by removing the appropriate exhaust knock-out.
See the following pages for duct layout requirements and maximum duct length.
REMP series remote blower

Cooktop
Cabinet blower, option on
ERV3015 and ERV3615 only
Floor 3 1/4 x 10 90° elbow

Backsplash
Downdraft vent
Wall Wall cap 12″ min. (30.5 cm)

3 ¼ x 10 to round transition
and 45° adjustable elbow

ExAmPLE oF LAyoUt wIth CAbINEt bLowER CoNFIGURAtIoN, ExhAUSt thRoUGh wALL

Wall board

Duct work between downdraft and remote blower
Backsplash

Cabinet back Downdraft vent

Outside wall

Cooktop

Downdraft vent
Downdraft vent configured for rear exhaust

Range

Downdraft vent configured for bottom exhaust
3 ¼ x 10 to round transition

Floor

Wall cap on outside wall

Wiring/conduit from downdraft to remote blower
Floor
ExAmPLE oF LAyoUt wIth CooktoP AND REAR ExhAUSt
All specifications subject to change without notice.

Wiring/conduit from downdraft to
in-line blower

Duct work

Duct work
ILHSF series in-line blower

ExAmPLE oF LAyoUt wIth RANGE AND bottom ExhAUSt

www.dacor.com

Phone: 800-793-0093

Search

26″ (66.0 cm)

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 5/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

ELECtRICAL LAyoUt

All tolerances: ±1/16″ (±1.6 mm) unless otherwise stated

Front of unit
Cabinet blower option on ERV3015, and ERV3615 only
Connection to cabinet blower

ExhAUSt oUtLEt LoCAtIoN oPtIoNS

SIDE VIEw

FRoNt VIEw

1 1/8″ (2.9 cm)

6 1/2″ CL (16.5 cm)

Blower wiring access hole

Front of unit
Motor
cover CL

Connection to remote/in-line

Blower wiring access hole

3″

CL

blower

Rear Exhaust Knock Out (3 ¼” X 10″)

There are 7/8″ access holes in the bottom and side of the downdraft vent for connecting the blower wiring and strain relief. The blower must be wired to turn on when the downdraft vent is turned on. When

Vertical center line of rear exhaust knock out lines up with vertical
center line of chassis
Bottom Exhaust Knock Out (1 ” X 16″)

installing a remote or in-line blower, run the blower wiring/conduit parallel to the duct work, connecting it to the downdraft vent on one end and the blower on the other.

The vertical center line of bottom knock out is offset 3″ Side Exhaust Knock Outs (1 ” X 16″)

Access from the front of the cabinet to the chassis and the electrical/ gas supplies of both appliances must be provided for inspection and service. Any drawers or shelves must be easy to remove for access to the cooktop, downdraft vent and utilities.

5″ (12.7 cm)

2 x 16, connects to side or bottom exhaust
on downdraft

1″ (2.5 cm)
3 ¼ x 10 to duct work
2″ x 16″ to 3 1/4″ x 10″ tRANSItIoN (INCLUDED)

All specifications subject to change without notice.

www.dacor.com

Search

Phone: 800-793-0093

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 6/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

CaBP3 Blower Layout (option ErV3015 and ErV3615 only)

Cooktop

Model ERV3015 ERV3615

a
12 1/8″ (30.7 cm)
9 3/4″ (24.8 cm)

B
5 5/8″ (14.4 cm)
8″ (20.3 cm)

C
1 3/4″ (4.4 cm)
4 1/4″ (10.8 cm)

ERV

ADAPTER

CABP3 CL

8 7/8″ (22.5 cm) from back of ERV cutout to center line of CABP3 exhaust in any orientation

Bottom exhaust configuration shown

Countertop
26 1/4″ (66.7 cm)
Duct connection center line

Downdraft vent center line
A
3 1/4 x 10 duct
connection

DUCT

ExhAUSt LoCAtIoNS AND SIDE DImENSIoNS FoR CAbP3 CAbINEt bLowER

FRoNt ExhAUSt DImENSIoNS CAbP3 bLowER – LEFt ExhAUSt

Downdraft vent center line B

Countertop

Downdraft vent Countertop center line

Duct connection center line
C

3 1/4 x 10 duct
connection

15 3/8″ (39.1 cm)
Duct connection center line

29 1/4″ (74.3 cm)

3 1/4 x 10 duct connection

FRoNt ExhAUSt DImENSIoNS CAbP3 bLowER – RIGht ExhAUSt
All specifications subject to change without notice.

www.dacor.com

Search

FRoNt ExhAUSt DImENSIoNS CAbP3 bLowER – bottom ExhAUSt
Phone: 800-793-0093

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,

Document # PG08-001

PRV30, PRV36, PRV48

Revised 02/28/14 Page 7/7

Renaissance Slim Chassis

PLANNING

Downdraft Vents

GUIDE

Duct work Design Considerations
For optimal performance, consult a qualified HVAC specialist when designing the duct system.
All duct work materials (including screws and duct tape) must be purchased separately by the customer.
Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.
When planning the cabinet layout, allow room for the exhaust duct coming out of the unit. Always look for the shortest, most direct route to the outside.
Do not use flexible metal duct.
Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible.
For best performance, use round duct instead of rectangular when possible, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of 24″ of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.
You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.
To prevent back-drafts, a damper at the duct outlet may also be required.
Make sure duct work does not interfere with floor joists or wall studs.
System exhaust location must take into account accumulated snowfall, where applicable.

Calculating the Maximum Duct run Length
Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the Blower Maximum Duct Straight Length table below. For best performance, keep the duct run as short as possible and never exceed the maximums stated.
The maximum straight duct length for the downdraft vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.
For example, for a downdraft vent system using 3 ¼” X 10″ rectangular duct, two (2) 3 ¼” X 10″ 90° elbows, a 3 ¼” X 10″ rectangular to 10″ round transition, and a rEMP16 remote blower:
From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet.
The equivalent length of each 90° elbow is 15 feet.
The equivalent length of 45° elbow is 2 feet.
The equivalent length of the transition is 4 feet.
The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet.
The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet – 34 feet = 24 feet.

Equivalent number of Feet Duct Elbows and Transitions

45° elbow, 8 inch

3 feet

3 ¼” X 10″, 45° elbow

7 feet

45° elbow, 10 inch 2 feet

3 ¼” X 10″, 90° elbow

15 feet

90° elbow, 8 inch

7 feet 3 ¼” X 10″, 90° flat elbow 20 feet

90° elbow, 10 inch 5 feet

3 ¼” X 10″ to 8″ round transition

4 feet

90° 3 ¼” X 10″ to 8″ round transition

25 feet

3 ¼” X 10″ to 10″ round transition

4 feet

Roof cap

Wall cap**

  • The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

** Not applicable for REMP series blowers.

Duct Size Used
8 Inch 10 Inch 3 ¼” X 10″

Blower Maximum Duct Straight Length

rEMP3

rEMP16

remote Blower remote Blower

iLHSF8 in-line Blower

iLHSF10

CaBP3

in-line Blower Cabinet Blower

50 feet (15.2 meters)

60 feet (18.3 meters)

50 feet (15.2 meters)

60 feet (18.3 meters)

40 feet (12.2 meters)

40 feet (12.2 meters)

70 feet (21.3 meters)

40 feet (12.2 meters)

70 feet (21.3 meters)

30 feet (9.2 meters)

40 feet (12.2 meters)

60 feet (18.3 meters)

40 feet (12.2 meters)

60 feet (18.3 meters)

30 feet (9.2 meters)

All specifications subject to change without notice.