BONECO U200 Ultrasonic Humidifier Instruction Manual
- June 13, 2024
- BONECO
Table of Contents
- Important safety instructions
- Description of the appliance/Scope of delivery
- Putting into operation
- Filling the tank
- Operation
- Cleaning/Maintenance
- Replacement of the demineralization cartridge
- Troubleshooting
- Technical data
- General Humidifier Questions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
U200 Ultrasonic Humidifier
Instruction Manual
PLEASE READ AND SAVE ALL INSTRUCTIONS!
Instructions for use
Important safety instructions
- Prior to using the appliance, read through the in structions for complete use and retain in a safe place for later reference.
- WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury.
- This appliance is not to be used by persons (including children) with impaired physical, sensory or mental capacities or insufficient experience and knowledge, unless they are supervised by someone who is responsible for their safety or given assistance with the use of this appliance. Children should be supervised to ensure that they do not play with the appliance (fig. 1).
- Use only the original adapter provided for operating the unit. The adapter provided may not be used for other units.
- Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way.
- Only operate the appliance when it is completely assembled.
- Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user.
- Do not pour water into the mist outlet of the appli- ance (5).
- Place the humidifier on a dry, level surface.
- Do not place the appliance directly on the floor, next to a heating vent or in the vicinity of electrical equipment. If the released mist reaches the floor or objects before it has fully evaporated, it may cause damage to them (6).
- The unit should be placed in an elevated position (7), e.g. on a table, chest of drawers, etc.
- ALWAYS unplug before removing/filling/emptying the water tank, before cleaning/maintaining, assembling/ dismantling of individual parts and before moving the appliance.
- Never pull the plug from the outlet by the cable or with wet hands.
- Do not touch the water in the base during operation because of high frequency vibrations in the water.
- Do not submerge the main body in water or other liquids (28).
- Place appliance where it is not easily knocked over (8).
- Always unplug when not in use.
- Do not run power cords under carpets, and do not cover with throw rugs. Arrange cord so that it will not be tripped over.
- Do not use the appliance where combustible gases or vapors are present.
- Do not expose the appliance to rain, or use near water, in a bathroom, laundry area or other damp location.
- This unit must be used in its upright position.
- Do not allow foreign objects to enter ventilation or ex haust opening as this may cause electric shock or damage to the appliance. Do not block air outlets or intakes.
- This appliance has a polarized plug (one blade is wider than the other). To reduce risk of shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
- A loose fit between the plug (receptacle) and the AC outlet may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
- Do not sit, stand or place any heavy objects on the appliance.
- Disconnect power supply before servicing.
- To protect health safety and proper humidifier function use only clean, contamination-free, cold, fresh tap water in your humidifier. If your water source is contaminated or if you are uncertain of its safety use distilled water. In addition, it is advised to clean and maintain your humidifier in a timely manner as instructed in this manual.
- When fragrancing the air, use the fragrance container provided (also see section «Use of fragrances»). Do not add any additives such as essential oils directly into the water tank or the water base (9). These additives will damage your appliance! Appliances that are damaged by additives are excluded from the warranty.
- The appliance does not have an integrated hygrostat. Use an external hygrostat to avoid damage through over-humidification.
- Remark: Neither humans nor animals can hear the high frequency vibrations.
- The manufacturer rejects all liability for damage caused by nonobservance of these instructions for use.
Foreword
Congratulations on choosing the Ultrasonic Humidifier U200!
Description of the appliance/Scope of delivery
Proper use:
The appliance must only be used for the humidification of the air indoors.
Unpacking
- Carefully remove the unit from its box.
- Remove the unit from the plastic bag (10).
- Remove the demineralization cartridge and the adapter from the small cardboard box. Open the sealed bag to remove the demineralization cartridge (11).
- Remove the water tank cap from the water tank and screw the demineralization cartridge onto the inside of the cap (12).
- Review the information given on the rating plate about the power supply.
Putting into operation
- Remove the plastic cover of the adapter and insert the country specific plug (13).
- Do not place the humidifier directly next to a heating vent or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Safety Instructions).
- The unit should be placed in an elevated position (7), e.g. on a table, chest, etc. at least 3 ft off the floor.
- The mist outlet must not be pointed directly at plants, furniture, or other objects (14). Keep distance of at least 20 inches (50cm).
- Soak the demineralization cartridge in a bowl of water for at least 24 hours before using it. The granules have to absorb water to reach maximum performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
- On average the demineralization cartridge should be replaced every 2 – 3 months. This interval can be shorter or longer depending on the hardness of your water. The cartridge must be exchanged at the latest after 6 months or the unit will not reach its full performance capability. See «Replacement of the demineralization cartridge».
- Read the instructions under «Filling the Tank» for filling the water tank.
- Place the water tank onto the base (17).
- Connect the adapter to the unit and the electrical socket and switch on the unit using the rotary switch (18).
- The appliance will reach full capacity about 10 to 15 minutes after being switched on.
- Make sure that the power cord is not pinched anywhere. Do not operate the appliance if the cord is damaged (2).
Filling the tank
Always switch off the appliance before removing the water tank. Do not reach
inside the nebulizer space while the appliance is running!
To protect health safety and proper humidifier function use only clean,
contaminationfree, cold, fresh tap water in your humidifier. If your water
source is contaminated or if you are uncertain of its safety use distilled
water.
Do not operate the appliance when the water tank is empty!
When the water reaches the minimum level, the unit switches off automatically.
- Make sure that there are no foreign objects inside the water tank.
- Remove the water tank cap from the tank (15). Fill the tank with clean, cold tap water (16). Close the cap of the water tank securely! Place the water tank onto the base (17). Do not add any additives to the water!
- Connect the adapter to the unit and the electrical socket and switch on the unit using the rotary switch (18). The empty indicator light may stay illuminated for some seconds until the base is filled with water.
Water quality maintenance
The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings. Good for approximately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It starts to work as soon as it comes in to contact with water, even if the unit is turned off. The Hydro Cell should be changed every one to two months*. Look at picture 19/20 for the position of the Hydro Cell in the water tank of the unit. Switch off the unit first. Contact your local retailer or check our website www.boneco.us for reorder information.
- Depending on the water quality.
Use of fragrances
On the outside of the main body is a fragrance container (21). Remove the
fragrance container by pushing it briefly. Fragrances can be dribbled onto the
fleece pad in the container. A few drops are sufficient – liquid must not be
present in the container. Apply fragrances only onto the fleece pad or a
cotton-wool pad and never add directly to the container (22)! Water additives
(e.g. etheric oils, fragrances, water purifiers) must NOT be added to the
water tank or directly into the nebulizer space! Even a small amount can
damage the plastic of these parts or create cracks. Appliances that are
damaged by additives are not covered by the warranty.
Remove the fragrance container before emptying and cleaning the appliance.
Operation
A) On-off switch and regulation of mist output
Turning the rotary switch clockwise switches the appliance on and at the same
time regulates the mist output from low to high.
B) Water level indicator
The water level indicator clearly shows how much water is in the appliance.
The appliance switches off automatically when the water tank is empty. The
water level indicator illuminates red.
For further information please read the section «Filling the tank».
After inserting the full tank, it may take a few seconds until the red light
goes out.
C) Switching blue illumination on/off
The blue illumination can be switched on and off with the sliding switch on
the backside of the main body. The red illumination cannot be switched off.
Cleaning/Maintenance
Always switch the appliance off before removing the water tank. Do not reach
inside the nebulizer space while the appliance is running!
EZCal and EZCal PRO are the only recommended cleaning and descaling solutions.
Do NOT use any other cleaning solutions since it can damage the product. Any
use of cleaning solutions apart from EZCal and EZCal PRO will void the
warranty.
Caution: water must not be allowed to enter the ventilation opening! This
will damage the appliance (23).
Caution – risk of electric shock and damage of the product!
- Switch the appliance off and unplug the adapter from the appliance (24).
- Remove the fragrance container by pressing it briefly (25).
- Clean the water tank and the nebulizer space regularly once a week (26/31).
- Use EZCal and EZCal PRO custom cleaning and descaling agents only to remove deposits from the membrane regularly (27). There is a sample of EZCal included in the packaging of your humidifier. Instructions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal and EZCal PRO. This can cause damage to the product and voids the warranty. Thoroughly rinse the base with tap water after using EZCal and EZCal PRO and make sure no EZCal and EZCal PRO residue remains in the base.
- Removing the mist outlet (28): use either the brush or a spoon to lift the mist outlet through the opening to remove it.
Important
- Make sure that no water gets into the lower part of the main body (29).
- Clean the inner parts with a soft cloth. Never use any solvents or aggressive cleaning agents (30).
- Only use the brush to clean the membrane (31). This should be done once a week.
- Change the water in the tank at least every 3 days.
Replacement of the demineralization cartridge
Always switch off the appliance before removing the water tank. Do not reach
inside the nebulizer space while the appliance is running!
The cartridge must be replaced every 2 – 3 months. If the water is very hard,
it may be necessary to replace the cartridge earlier. White dust around the
appliance is a sure sign that the cartridge needs replacing. If white residue
continues to form around the appliance after a new cartridge has been
inserted, please make sure that the water you are using is untreated. If the
water flows through a domestic water softener system before it is used in the
unit, salt will precipitate around the appliance. The demineralization
cartridge or the granules must be exchanged at the latest after 6 months or
the unit does not reach its full performance anymore.
Option A: Replace the granules
- Remove the water tank from the base and unscrew the water tank cap (32).
- The demineralization cartridge is attached to the inside of the cap. Unscrew the cartridge from the cap by turning it counter-clockwise (33). Important: do NOT dispose of the tank cap!
- Open the cartridge (34).
- Throw the content (granules) into the waste (35). Attention! Disposed granules can make the floor slippery!
- Place the enclosed pink styrofoam piece in the center of the cartridge (36).
- Pour the contents of one refill resin bag into the plastic cup that is included with the refill resin packaging (37).
- Place the empty cartridge with the plug in the center onto the plastic cup (38).
- Turn the plastic cup and cartridge over and shake until all granules are in the cartridge (39).
- Remove the plastic cup and the pink styrofoam piece from the cartridge (40) and retain for future use (the refill resin consists of 3 refill bags) (41).
- Close the cap (42).
- Soak the demineralization cartridge in a bowl of water for at least 24 hours before use (45). The granules have to absorb water to reach maximum performance.
- Now screw the cartridge onto the water tank cap (46). Close the tank cap securely! Place the water tank onto the base (47).
Placing granules in the center of the cartridge allows them to escape in the unit or to clog the unit. The unit will no longer operate properly and the granules need to be cleaned out thoroughly.
Option B: Replace the entire cartridge
- Remove the water tank from the base and unscrew the water tank cap (32).
- The demineralization cartridge is attached to the inside of the tank cap. Unscrew the cartridge from the cap by turning it counter-clockwise (33). Important: do NOT dispose of the tank cap!
- Dispose of the old cartridge (43).
- Unpack the new cartridge (44).
- Soak the new cartridge in a bowl of water for at least 24 hours before use (45). The granules have to absorb water to reach maximum performance.
- Now screw the cartridge onto the water tank cap (46). Close the tank cap securely! Place the water tank onto the base (47).
Troubleshooting
Problem | Possible cause | What to do |
---|---|---|
Unit does not operate | Appliance has no power | Connect appliance to power |
socket
| No water in the tank (Red water level indicator is illuminated)| Fill tank
with water
No mist output| Mist output setting too low| Increase mist output
Residue of cleaning agent| Rinse with clear water
Demineralization cartridge is clogged| Remove 2-3 teaspoons of granules from
the cartridge and dispose of them.
Soak cartridge in water for 24 hours
Weak mist output| Water temperature too low| Set mist output to maximum. The
appliance will work properly again after 10 minutes.
Mineral deposits on membrane| Clean membrane
White deposit around the appliance| Demineralization cartridge exhausted|
Replace demineralization cartridge or granules
Used granules must go in waste
Technical data
Electrical voltage | 100 – 240 V / 50-60 Hz |
---|---|
Power consumption up to | 20 W |
Humidity output up to | 1.8 gallons / 24h (6.8 L / 24 h) |
Suitable for rooms up to | 430 sq ft (40 m²) |
Dimensions (LxWxH) | 9.5 x 4.7 x 10.4 inches (24 x 12 x 26.3 cm) |
Weight (empty) | 4 lbs (1.8 kg) |
Operating noise level | < 30 dB(A) |
Accessories | Demineralization cartridge A7531 |
Hydro Cell A200
EZCal A7417
EZCal PRO A100
Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry thoroughly.
Preferably store the appliance in its original box, in a dry place away from
high temperatures.
Legal notice
The AC/DC adapter is cUL-listed.
Subject to technical change. The instructions for use are protected by
copyright© BONECO AG.
Accessories
Contact your local retailer or check our website
www.boneco.us for reorder information.
Customer Service
Customer Service (USA) 1-800-336-0326
www.boneco.us
General Humidifier Questions
Q. Why isn’t there enough moisture in my room?
A. How often do you run the unit? If the unit is only run at night, then during the day the moisture level will drop if moisture is not constantly added to the air.
Q. Do you leave your door open or closed when theunit is running?
A. a. By leaving the door open, this allows moisture to leave the room and go into other areas of the house. If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running. A. b. Wood, leather, carpet, curtains, and other types of fabric soak up a lot of moisture, thus not leaving enough moisture for the air. If the window is left open, then this allows moisture to escape the room. Another factor is a lot of times the unit is placed next to a heating device. The idea is that the air blowing into the room will quickly place moisture around the room. Unfortunately, this concept does not work because the hot air coming out of a vent will soak up most of the moisture, and none of the air within the room will receive any.
Q. How much moisture do I need in my room?
A. Suggested humidity levels are between 40 – 60%.
Q. What are the effects of too little or too much humidity?
A. Dry air can cause dry skin, static electricity, out of tune musical instruments, increased levels of dust dry air causes dust to rise, damage to wooden objects dry out and eventually cracks appear, discomfort, sickness, and dries out nasal membranes. Over-humidifying the air can cause mold and wallpaper to peel.
Q. Why do I need a humidifier when I can just open my window?
A. The moisture level within the outside air is not high enough to humidify a room. The colder the air the less moisture it is capable to hold, and the more the air is heated up the percentage of relative humidity is lower. Relative humidity means the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated. The difference is higher between outside and inside temperatures; more humidification is needed because of the dry air in the room.
Q. Where should I place my humidifier?
A. The unit should be free-standing and not close to a wall, window, door, or thermal bridge so that air may circulate around the unit.
Ultrasonic Frequent Questions
Q. Why does it say open/close on the demineralization cartridge cap?
A. These directions are there in case you decide to use the refill option to replace the granules; the purpose is for how to open and close the cap. If you did open the cap before placing it in the water tank, you will most likely notice that there are granules in the water tank and the base of the unit. Immediately turn off the unit, and empty the water out of the base and the water tank. Begin removing all granules from the base and the water tank. Use brush to clean around membrane. Caution: Do not dispose of granules in sink! Used granules must go in waste!
Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.
A. This sometimes occurs when the cartridge, or even the granules, are replaced. This does not occur with all replacement cartridges or granules, and is a reaction of water content and the Ultrasonic vibrations. This is not an indicator to replace the cartridge.
Q. There is no fill-line on the water tank, how far may I fill it up?
A. There is no fill line on the water tank, and it may be filled all the way to the top.
Q. What is the purpose of the demineralization cartridge DMC?
A. The DMC removes minerals from the water to prevent white dust. The contents of the cartridge need to be soaked for 24 hrs prior to first using the unit so that they may fully expand and remove minerals from the water. The contents of the DMC have a life of 2 – 3 months. The cartridge may need to be replaced more often depending on water hardness and how often the unit is used. An indication of when the DMC needs to be changed can be white dust or reduced amount of mist output.
Q. Is it ok to use distilled water with the unit?
A. For best results with your ultrasonic humidifier use distilled or reverse- osmosis water and remove the demineralization cartridge.
Q. I just replaced the contents of the cartridge and now have granules everywhere.
A. First, make sure there are no granules in the middle of the cartridge. Placing granules in the middle of the DMC allows them to escape in the unit. Immediately turn off the unit, and empty the water out of the base and the water tank. Begin removing all granules from base and water tank. Use brush to clean around membrane. Caution: Do not dispose of granules in sink! Used granules must go in waste!
Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?
A. The idea with this unit is to allow one to force humidity into the air. Because of this, the carpeting or wood floor surrounding the unit may become damp. If the unit is placed at least 3 feet off the floor, the mist will have the opportunity to evaporate before hitting the floor.
Q. Water does not go into the tank.
A. In order to fill the tank, it must be turned upside down. The cartridge is placed on the water tank cap. Do not pour water in the tube which is the mist outlet.
Q. White dust is emitted from the unit
A. White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process. Solve the problem: • Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours. If the cartridge is soaked in the water tank, the water in the tank and the base needs to be replaced before using the unit. • Exchange the demineralization cartridge after 1-2 months when you use very hard water for softer water after 2-3 months. No matter how hard your water is, exchange the cartridge at the very latest after 6 months. • Don’t use water from a pre-installed water softener, or sodium instead of calcium will be emitted from the unit. Use distilled water instead and remove the demineralization cartridge. • For very hard water areas use only distilled water and remove the demineralization cartridge. • Use Reverse-Osmosis water R-O water instead of distilled water and remove the demineralization cartridge.
Q. Humidity level is not changing or does not reach the desired humidity level.
A. If the water tank needs refilling more than once per day, the unit is working properly and the climatic condition in the room has an influence on the humidity. • open space with high ceilings not only the footage of the room counts but also the height – high-rise buildings require more humidification. • open windows – works similar to air circulation if it is very cold outside don’t open the window more than 2 times per day for 3 minutes • big difference between outside temperature and inside temperature – the colder the air the less moisture it is capable to hold and the more the air is heated up the lower is the percentage of relative humidity =the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated • position of the unit - if it is placed close to a door, window or air vent. This increases the air circulation. Reasons for low humidity level: • air circulation is very high air is fully exchanged several times per day – the humidifier needs to starts its work from scratch • insulation of home see air circulation
Q. Tank is leaking
A. Check if there are any hairline cracks. Dropped units or water tanks that are cracked will not be covered under the warranty. Please contact the retailer where the unit was purchased from in case your unit arrives damaged.
Q. Placing the face in the mist
A. It is not recommended that anybody places their face in the mist. It is an electrical product and should not be played with.
Q. No mist / unit is not working / empty indicator keeps flashing
A. Fill up the water tank. Check if water is flowing through the demineralization cartridge attached to the water tank cap. If the water tank is full but there is only little water in the base it indicates that the water is now flowing through the demineralization cartridge. • Wait for 15 minutes to allow the mist to come out of the unit. • If the unit is not working and the empty light is not flashing you might have set the desired humidity too low and the current humidity level in the room is higher. That is why the unit switches off automatically. • If the empty indicator keeps flashing and the tank is full, the water is not flowing through the cartridge. Exchange the cartridge or the granules in the cartridge after 2-3 months, in areas with hard water exchange the cartridge after 1 -2 months. However, the demineralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore • If the granules are new, see the following instructions: • Make sure the cartridge and/or granules were soaked for 24 hours, dry granules take even longer for water to filter through the cartridge and into the base. Next, please remove 2 tablespoons of granules from the cartridge, and throw them away. When there are too many granules in the cartridge it does not allow water to flow from the tank to the base.
Q. Water tank cap is too tight to unscrew
A. This could be a cause of the air pressure within the water tank. Depress the spring on the bottom of the water tank cap to release air from the water tank. Continue to do this until you are able to unscrew the water tank cap.
Q. Unit is running intermittently.
A. How long has it been since the contents of the cartridge were replaced? If 2-3 months have passed, it is time to replace the contents of the cartridge. However the demineralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore. • If the contents of the cartridge were just replaced there are probably too many granules in the cartridge. Remove 2 tablespoons of granules from the cartridge.
Accessories
Q. Do I need to keep any parts before I replace the demineralization cartridge?
A. Yes, always keep the water tank cap this is the piece that attaches the demineralization cartridge to the water tank.
Q. What is the Hydro Cell and how long is it good for?
A. The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings. Good for approximately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It needs to be replaced every one to two months. Depending on the water quality.
Q. Placement of the Hydro Cell
A. Please see picture 19/20 for instructions.
Q. What is EZCal and EZCal PRO?
A. There is a sample packet of EZCal included in the packaging of your humidifier. EZCal and EZCal PRO are used for cleaning and descaling any of the humidifiers and cleans mineral build-up. EZCal and EZCal PRO are the only recommended cleaning and descaling solutions. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal and EZCal PRO will void the warranty. Instructions for using are on the packet. Only use 1 packet for 32oz of water. Do not change the ratio. It can also be used for other humidifier brands. Thoroughly rinse the base with tap water and make sure no EZCal and EZCal PRO residues remains in the base! EZCal and EZCal PRO are available at selected retail stores and online www.boneco.us.
Please check our website www.boneco.us
for further information.