Ventilating Fan
INSTALLATION INSTRUCTIONS
Model No.
READ AND SAVE THESE INSTRUCTIONS
Thank you very much for purchasing our ventilating fan.
Please read these instructions carefully before attempting to install, operate
or service our ventilating fan. Failure to comply with instructions could
result in personal injury or property damage. Please retain this booklet for
future reference.
UNPACKING
Unpack and carefully remove the unit from carton.
Refer to the supplied accessories list to verify that all parts are present.
SUPPLIED ACCESSORIES
Part name | Appearance | quantity |
---|---|---|
Louver | ![iLIVING ILG8FV110 Ventilating Fan - |
ACCESSORIES](https://manuals.plus/wp-content/uploads/2023/10/iLIVING-ILG8FV110
-Ventilating-Fan-ACCESSORIES.png)| 1
Suspension bracket assembly| | 1
Long screw (ST4X30)| | 5
Installation instructions| | 1
DESCRIPTION
These ventilating fan models are listed by ETL under ETL file No.5011292.
These ventilating fan models use a sirocco fan driven by a brushless DC motor.
The motor is designed to have an extended service life with reduced energy
consumption.
The louver covering the fan body is a spring-loaded, quick remove type. A
damper for preventing air counter flow is provided.
The suspension bracket assembly can be used for both new construction and
retrofit situation.
The light uses high brightness SMD LED as light source to ensure the
performance.
GENERAL SAFETY INFORMATION
- Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C).
- Make sure that the electric service supply voltage is AC 120V, 60Hz.
- Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).
- Always disconnect the power source before working on or near the fan, motor, light fixture or junction box.
- Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
- Do not kink the power cord.
- Do not install the unit where ducts are configured as shown in Fig.A.
- Provide make up air for proper ventilation.
- A statement to the effect that when the product is to no longer be used, it must not be left in place but removed, to prevent it from possibly falling.
CAUTION:
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- Not for use in cooking area. (Fig.B)
- This product must be properly grounded.
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the
following:
- Use this unit only in the manner intended by the manufacturer. If you have any questions, contact with the manufacturer.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
- Sufficient air is needed for proper combusition and exhausting of gases through the flue (chimney) of fulel burning equipment to prevent back drafting. Follow the heating equipment manufacture′s guideline and safety standards such as those pulished by the National Fire Protection Association (NFPA), and the Ameriacan Society of Heating, Refrigration, and air conditioning Engneers (ASHRAE) and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter)-protected branch circuit.
- These models are ETL listed for tub and shower enclosures.
- Not to be installed in a celling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
DIMENSIONS
Model: ILG8FV111
Unit: inches(mm)
Model: ILG8FV112
No. | Part name | No. | Part name |
---|---|---|---|
1 | Blade | 8 | Base PCB box |
2 | Louver | 9 | Humidity sensor module |
3 | Adaptor | 10 | CO2 sensor module |
4 | Damper | 11 | Night light module |
5 | Frame assy | 12 | Motion sensor module |
6 | Knockout plate | 13 | LED light |
7 | Junction box |
WIRING DIAGRAM
Model: ILG8FV110/ LG8FV112 | Model: ILGFV111 |
---|
FEATURE
All fans come with Flow-Selection speed switch, Multi-Speed switch, Time Delay switch and Air Trimming switch.
- Flow-Selection. The switch with choosing option 50-80-110CFM is set on the PCB box and is default high speed.
- Multi-Speed. The switch allows the fan to run at the lower speeds continuously to meet Indoor Air Quality. As an example, when Flow-Selection setting is 80CFM, Multi-Speed can be chosen 0, 50, 60, or 70CFM as a low speed.
- Time Delay. The switch is for time delay setting. Setting range is 0, 5, 10, 20, 30, 45 or 60 minutes.
- Air Trimming switch. The switch is for micro-adjusting the air volume when the actual airflow is lower than set.
INSTRUCTIONS:
Firstly, the power switch should be turned on.
- When the control switch is turned on, the fan runs at high speed continuously only. The sensors will not work and Time delay switch does not apply to this mode.
- When the control switch is turned off, the fan runs at chosen low speed on Multi-Speed switch continuously, and boosts in high speed when the sensor detects. The fan runs at high speed for amount of time that selected from the Time Delay switch before returning to low speed when the sensor stops detection.
INDICATION (PLUG AND PLAY FUNCTION DEVICES)
-
Humidity sensor module. It should be inserted into USB interface.
The fan runs or boosts to high speed when humidity value reaches setting. The fan runs in low speed after a period of time delay or stops working when humidity value is lower than setting.
Humidity detection value setting range: 30% – 80% -
CO2 sensor module. It should be inserted into USB interface. The module begins to detect environmental CO2 concentration when fan is on for 2 minutes, then the fan starts to run or boosts to high speed when concentration level is over 1000PPM. The fan runs in low speed after a period of time delay or stops working when concentration level is less than 800PPM.
-
Motion sensor module. It should be inserted into USB interface. The fan runs or boosts to high speed when motion sensor begins to detect.
The fan runs in low speed after a period of time delay or stops working when you are out of detection range. Motion Sensor detection range as below,The distance that motion can be detected is limited to 10 feet (3m).
The field of view of the sensor is 90°. (Room temperature is 25℃). -
Night Light module. It should be inserted into USB interface. Night Light module automatically turns on according to environmental brightness. The night lamp turns on automatically when environmental ray is weak. The night lamp goes off automatically
when environmental brightness is strong.
The modules can be selected for 3 installation positions at most.
Optional modules and corresponding models are listed as follows.
Notes:
All module sold separately, not included in base fan model.
Suitable for use with solid-state speed controls.
| Module| LED light &Night light
---|---|---
Model| CO2 Sensor| Humidity sensor| Motion sensor| Night light
ILG8FV110| 0| 0| X| x| x
ILG8FV111| 0| 0| X| x| 0
ILG8FV112| 0| 0| 0| 0| X
※ “○”representative can be used, “×”representative can not be used
INSTALLATION (PLUG AND PLAY FUNCTION DEVICES)
You can purchase the specified PLUG AND PLAY devices that are explained on
page 6 and install them in positions.
Position A is for CO2 Sensor module, position B is for Humidity Sensor module,
position C is for Night Light module, position D is for Motion Sensor module.
- Fix to the specified devices to the slot, till hear the sound installed in place.
- Access USB interface, insert the connector of module into USB receptacle.
INSTALLATION (NEW CONSTRUCTION)
CAUTION:
Please wear gloves during the installation work.
IMPORTANT:
Remove the tape from damper and adaptor before installation. As shown below:
Joist situation:
Two cases of spacing L :
12 inches (305 mm)
16~24 inches (406~610 mm)
If the spacing L is 12 inches (305 mm) on joists, please follow the
installation step as (Fig.1).
Secure 4 screws (ST4X30) at flange of frame to the joists. Then follow step 6
to 9 of installation (page 6-8) to complete the installation.
A If the spacing L is 16~24 inches (406~610 mm), please use the suspension
bracket assembly.
https://manual-hub.com/
INSTALLATION(NEW CONSTRUCTION)CONTINUED
-
Bend down 8 tabs for positioning as (Fig.2.a) and unfold the bracket assembly as (Fig.2.b).
-
Fix one side of the bracket assembly to the joists by drilling 2 tapping screws (ST4x20) which have been fixed on it. (Fig.3)
-
Adjust the length of bracket assembly as the spacing between joists, and install to joist by drilling the other 2 tapping screws which have been fixed on the other side. Adjust the active part of bracket assembly to the right position. (Fig.3)
-
Place the adaptor on the bracket assembly as indicative position, and install it by using 2 self-drilling screws (ST4X30). (Fig.4)
-
Push the fan body upwards until the fan body is stuck by the buckle on the adapter and secure the fan boby by using the other 3 self-drilling screws (ST4X30). (Fig.5)
CAUTION: Hold the fan body by your hand to prevent falling before fixing the screws. -
Install a circular duct and secure it with clamps or ties and seal it with mastic or approved duct tape.
A 4″ or 5″ or 6″ circular duct is needed to connect to relevant part of adaptor. (Fig.6) -
Remove the knock-out plate and secure conduit or stress relief to knock-out hole. (Fig.7. )
Refer to wiring diagram on page 4.
Use UL approved wire nuts, connect house power wires to the ventilating fan wires (Fig.7. ), then fix it to fan **body.![iLIVING ILG8FV110 Ventilating Fan
-
adapter 3](https://manuals.plus/wp-content/uploads/2023/10/iLIVING-ILG8FV110 -Ventilating-Fan-adapter-3.png) IMPORTANT:**
Follow all the local electrical safety codes as well as the National Electrical Code (NEC).-
Finsh ceiling work. Ceiling hole be aligned with the inside edges of the flange. (Fig.8)
IMPORTANT: After finishing the celling work, fill gap between flange and celling with caulk or other sealant to preven air leakage. -
Insert mounting springs into slots and mount louver to fan body(Fig.9 )
Notes:
Suitable for use with solid-state speed controls.
Solid-state speed controls may cause harmonic distortion which can cause motor humming noise. -
The louver with LED light, refer to the following installation method.
CAUTION:
1. Before turning on the light, make sure the connector at the correct position. If not, the lighting cannot work.
2. The claw of connector must latch the rib completely. (Fig.10)
• Insert the louver mounting spring on the wiring side into the slot. (Fig.10)• Insert the plug connector into the housing of the lighting unit and insert the other mounting spring into the slot as shown and mount louver to fan body.
(Fig.10, Fig.11)
CAUTION:
Mount carefully so that lead wire of light unit is not pinched.
Notes:
Stable for use with soildstate speed controls.
Soildstate speed controls may harmonic distortion which can cause a motor humming noise. -
The louver with a module, refer to the following installation method.
Insert the louver mounting spring on the wiring side into the slot.
Insert the USB connector into the USB receptacle and insert other mounting spring into the slot as shown and mount louver to fan body.
(Fig.12)
-
INSTALLATION RETROFIT)
-
Put the folded bracket assembly into ceiling from the hole, then follow step 3-4 of installation I (NEW CONSTRUCTION) (page 5) to complete the bracket installation work. (Fig.13)
-
Install a circular duct and secure it with clamps or ties and seal it with mastic or approved foil tape.
A 4″ or 5″ or 6″ circular duct is needed to connect to relevant part of adaptor. (Fig.14)
Follow step 4 of installation (NEW CONSTRUCTION) (page 6) to complete the adaptor installation. (Fig.14) -
Remove the knock-out plate and secure conduit or stress relief to knock-out hole. (Fig.15) Refer to wiring diagram on page 4.
Use UL approved wire nuts, connect house power wires to the ventilating fan wires (Fig.15), then fix it to fan body.
IMPORTANT:
Follow all the local electrical safety codes as well as the National Electrical Code (NEC). -
Push the fan body upwards until the fan body is stuck with the joint, and secure them by using the other 3 self-drilling screws (ST4X30) (Fig.16)
-
Follow step 10 of installation (NEW CONSTRUCTION) (page 7-8) to complete the installation work.
MAINTENANCE (CLEANING)
WARNING:
Disconnect power source before working on unit. Routine maintenance must be
done every year.
CAUTION:
- Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
- Do not immerse motor in water when cleaning.
- Do not soak resin parts in water over 140°F (60°C).
- Remove louver. (Squeeze mounting spring and pull down carefully). (Fig.17)
- Clean louver. (Don’t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth). (Fig.18)
- The louver should be dry after cleaning.
- Remove dust and dirt from fan body using a vacuum cleaner. (Fig.19)
- Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with clean cloth. (Fig.20)
- Reinstall louver.
PRACTICAL GUIDE TO INSTALLATION
Properly insulate the area around the fan to minimize building heat loss and
gain. (Fig.21) Loose fill or batt insulation can be
placed directly over the fan housing in the attic.
The fans and fan/light combination units do not create excessive heat that is
a common problem with recessed light fixtures or some competitors′ fan / light
combinations. our efficient, cool-running motors and our LED lighting unit do
not create enough ambient heat to be subjected to these limitations.
The ducting from this fan to the outside of the building has a strong effect
on the air flow, noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance, and avoid installing
the fan with smaller ducts than recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans installed with existing ducts
may not achieve their rated air flow.
SPECIFICATIONS
Model No.| Air direction| Voltage
(V)| Frequency
(Hz)| Duce
diameter
(inches)| Noise
(Bones)| Power consumption
(W)| Speed
(rpm)| Air volume
at 0.1″ WG
(CFM)
---|---|---|---|---|---|---|---|---
Fan| light| \ .1 ight
ILG8FV110
ILG8FV112| Exhaust| 120| 60| 4″ 5″ ()”| <0.3| 6| | | 901| 50
<0.3| 7.| | | 936| 60
0.3| 8.| | | 954| 70
0.4| 9.| | | 987| 80
0.6| 11| | | 1037| 90
0.8| 13.| | | 1079| 100
1.0| 16| | | 1159| 110
ILG8FV111| Exhaust| 120| 60| 4″ 5″ 6″| <0.3| 6.| 10| 0.7| 871| 50
<0.3| 7.| 10| 0.7| 888| 60
<0.3| 8.| 10| 0.7| 922| 70
0.3| 9.| 10| 0.7| 945| 80
0.5| 11.| 10| 0.7| 1000| 90
0.7| 13.| 10| 0.7| 1044| 100
0.9| 15.| 10| 0.7| 1095| 110
WARRANTY
This Ventilating Fan comes with a ONE-YEAR LIMITED COMPONENT WARRANTY. If your
unit does not appear to be working properly, please contact our service center
by calling 1-800-317-1688.
Prior to your call, please have your product’s model number, serial number,
and purchase receipt/ invoice ready so that we may assist you more
expediently.
iLIVING USA
239 Harbor Way
South San Francisco, CA 94080
Tel:800-317-1688
Email: service@ilivingusa.com
Like us on Facebook:https://www.facebook.com/ilivingusa/
Follow us on Twitter: @iLIVINGUSA
Check out our website:www.ilivingusa.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>