KumeAi RFID PR01-02 UHF RFID Reader Writer User Guide

June 13, 2024
KumeAi RFID

KumeAi RFID PR01-02 UHF RFID Reader Writer

Kumeai Bluetooth UHF RFID Reader

Model| Body Size (mm)| Battery Capacity (mAh)| Supported Platforms| Read-Tag Performance| Heat Dissipation
---|---|---|---|---|---
PR01| 115 x 23 x 65| 4000| Windows, Linux, MAC, Bluetooth, Android, iOS| Excellent| No external heat sink required. Long-term continuous full load
work at room temperature without heating.
PR02| 138 x 32 x 76| 10000| Windows, Linux, MAC, Bluetooth, Android, iOS| Excellent| No external heat sink required. Long-term continuous full load
work at room temperature without heating.

Product Usage Instructions

  1. Ensure the battery is fully charged before using the RFID reader.
  2. Turn on the RFID reader by pressing the power button located on the device.
  3. Pair the RFID reader with your desired platform (computer or mobile device) using Bluetooth connectivity.
  4. Install the necessary software or apps on your platform for RFID tag reading.
  5. Place the RFID tags within the range of the reader’s antenna to initiate the reading process.
  6. Wait for the reader to detect and read the RFID tags. The read-tag performance is excellent, ensuring accurate and efficient data capture.
  7. Review the data and information captured from the RFID tags on your platform’s software or app.
  8. If using the RFID reader continuously for long periods, ensure it operates at room temperature to avoid heating issues.

SPECIFICATION

  • Body size:
    • PR01: 115mm X 23mm X 65mm
    • PR02: 138mm x 32mm x 76mm
  • Battery capacity: PR01: 4000 MA H PR02: 10000 MA H
  • Support for computer / mobile Apps: Windows, Linux, MAC. Bluetooth, Android.IOS

Excellent read-tag performance

  • Label identification is sensitive and stable.
  • PR01 stable recognition distance of 1.5 – 2.5 m.(Standard white card 9662)
  • PR02 stable recognition distance of 4 – 5 m.(Standard white card 9662)
  • Multi-label identification performance:> 50 labels.
  • Label identification speed:> 50 pieces / s.

Solve the problem of fever thoroughly

  • No external heat sink is required.
  • Long-term continuous full-load work at room temperature without heating.
  • Continuous current is <200mA @ 3.5V (26 dBm Output).
  • Peak pulse current was <260 mA.

Excellent stability

  • 24 hours x 365 days of work does not crash.
  • Performance by the shell, electromagnetic environment and other external impact.
  • Wide temperature design, the temperature drift coefficient is very low.

Excellent consistency
A model of consistent design. All the highest grade of components are selected to ensure the stability and consistency of all parameters.

Specification

working voltage DC 3.5V – 5 V
Standby state current <80mA (EN foot high level)
Sleep state current <100 uA (EN pin low level)
working current 180mA @ 3.5V (26 dBm Output,25°C)。

110mA @ 3.5V (18 dBm Output,25°C)。
start time| < 100mS。
working temperature| – 20 °C| –| + 70| °C
Storage temperature| – 20 °C| –| + 85| °C
Working humidity| < 95% ( + 25 °C)
Air protocol|  | interface| EPC global UHF Class 1 Gen 2 / ISO 18000-6C
Scope spectrum| of| working| 840-960MHZ
Work area support| US, Canada and other regions following U.S.FCC
Europe and other regions following ETSI EN 302 208
Mainland China、Taiwan
Japan、 Korea、Malaysia
Output power range| 12-26 dBm
Output power accuracy| +/- 1dB
Output power flatness| +/- 0.2dB
receiving sensitivity| < -70dBm
Stock the label peak speed| With> 50 sheets / second
Label cache area| 200 sheet tags @ 96 bit EPC
communication interface| Bluetooth TYPE-C
Communication Porter rate| 115200 bps (default and recommended)
38400bps
size| Length 115mmX height 23mmX width 65mm
---|---
battery capacity| 4000 / 10000 mAh
levels of protection| IP
duration of flight| 10 hours
Read the distance| PR01:1.5-2.5m / PR02: 4-5 m (9662) (depending on the label size and environment)

FCC Warning

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 0cm between the radiator and your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>