sifam tinsley TT25-78FH2DRZ00000 Signal Conditioner Instruction Manual
- June 13, 2024
- sifam tinsley
Table of Contents
siam tinsley TT25-78FH2DRZ00000 Signal Conditioner
PRODUCT INFORMATION
Theta Hz the transducer is used for frequency measurement. The output signal is proportional to the measured frequency and is either load-independent DC Current or load-independent DC Voltage
Special Features
- Fully onsite programmable input range
- Available in Single or Dual output type
- Onsite selectable output type. (DC / DC voltage)
- Accuracy class 0.2 ( IEC / EN 60688)
- Seven Segment LCD Display
- RS485(Modbus) Communication
- Output Response Time < 400 msec
Application
Theta Hz the transducer is used for frequency measurement. The output signal
is proportional to the measured frequency and is either load-independent DC
Current or load-independent DC Voltage.
Product Features
Measuring Input| A sine wave or distorted waveform of nominal input
voltage with a fundamental wave.
---|---
Analog Output (Single or dual)| Isolated analog output which can be set
onsite to either voltage or current output.
Accuracy| Output signal accuracy Class 0.2 as per International
Standard IEC / EN 60688 .
Programmable Input/Output| The Transducer can be programmed onsite using
the front key & display or through the programming port (COM) or RS 485.
LED Indication| LED indication for power on and output type. (Current
output: Red LED, Voltage output: Green LED)
---|---
Display Module (Optional)| Op optional 7-segment LCD with backlit
& keypad. For display ng measured parameters
& onsite configuration of In pu t/ output
Rs485
Communication (Optional)
| Optional RS485 communication is available. For reading measured parameters & onsite configure ratio n of input/ output.
Technical Specifications
Reference Conditions for Accuracy
Ambient temperature| 23°c +t- 1°c
Pre-conditioning| 30 min acc. to IEC / EN 60688
Input Variable| Rated Voltage I Rated Current
Input waveform| Sinusoidal , Form Factor 1.1107
Input signal frequency| 50 or 60Hz
Auxiliary supply voltage| At nominal range
Output Load| Rn = 7.5 V / Y2 ± 1%
With DC current output signal Rn = Y2 / 1 mA ± 1%
With DC voltage output signal
Miscellaneous| Acc. to IEC / EN 60688
Accuracy ( Acc. to IEC / EN 60688)
Reference Value| Output end Value Y2 (Voltage or Current)
Basic Accuracy| 0.2*C
Factor C (The highest value applies if calculated C is less than 1, then C=1
applies
Measuring Output Y( Single or Optional Dual)
Auxiliary Power Supply
AC/DC Auxiliary Supply| 60V… 300 VAC-DC ± 5% or
24V… 60VAC-DC ± 10%
AC Auxiliary supply frequency range| 40 to 65 Hz
Auxiliary supply consumption
Environmental
Nominal range of use| 0 to 45 °C
Storage temperature| -40° C to 70° C
Relative humidity of annual mean| s 75%
Altitude| 2000m max
Influence of Variations
As per IEC / EN 60688
standard Output Stability
| < 30 min
Output Characteristics
Safety
Protection Class| II (Protection Isolated, EN 61010)
Protection| IP 40, housing according to EN 60 529
IP 20, the terminal according to EN 60 529
Pollution degree| 2
Installation Category| Ill
Insulation Voltage| 50Hz,1min. ( EN 61010-1)
7700VDC, Input versus outer surface 5200VDC, Input versus all other circuits 5200VDC, Auxiliary supply versus outer surface and output
690VDC, Output versus output versus each other versus outer surface.
Installation Data
Mechanical Housing| Lexan 940 (polycarbonate) Flammability Class V-0 acc. to UL 94, self-extinguishing,
nondripping, free of halogen
Mounting position| Rail mounting/wall mounting
Weight| Approx. 0.4kg
Additional error
Temperature influence| ±0.2% 110 ° c
Ambient tests
EN 60 068-2-6| Vibration
Acceleration| ±2g
Frequency range| 10….150…10Hz, rate of frequency sweep: 1 octave/minute
Number of cycles| 10, in each of the three axes
EN 60 068-2-7| Shock
Acceleration| 3*50g
3 shocks in each direction
EN 60 068-2-1/-2/-3| Cold, Dry, Damp heat
IEC 61000-4-2/-3/-4/-5/-6 EN 55 011| Electromagnetic compatibility.
ON LED| Aux. supply healthy condition| Green LED continuous ON
---|---|---
O/P1 LED
| ****
Output1 voltage selection
| ****
Green LED continuous ON
Output1 Current selection| Red LED continuous ON
O/P2 LED
| Output2 voltage selection| ****
Green LED continuous ON
Output2 Current selection| Red LED continuous ON
Electrical Connections
Connection | Terminal details |
---|---|
Measuring input |
6
Auxiliary Power supply| -,+| 7
8
Measuring output – 1| +| 1
2
Measuring output – 2| +| 3
4
Dimensions
Programming
Programming of the transducer can be done in three ways| 1) Programming Via Front LCD & two keys.
-
Programming Via optional RS485(MODBUS) communication port ( Device address, Password, communication parameter, Output Type & simulation mode can be programmed).
-
Programming Via Programming port
available at front of Theta Hz Transducers using (optional) PRKAB601 Adapter.
---|---
Programming Via Programming port (COM)| A PC with RS 232 C interface
along with the programming cable PRKAB601 and the configuration software are
required to program the transducer.
The connections between| “PC<-> PRKAB 601<-> Theta Transducer The power supply must be applied to the Transducer before it can be programmed.
The Configuration software is supplied on a CD. The programming cable PRKAB601 adjusts the signal level and provides electrical insulation between the PC and
Theta Transducers.
---|---
Configuring Rish Con Transducer| To configure Theta Transducer Input
/
output one of the three programming methods can be adapted along with mechanical switch setting (DIP switch setting on PCB for output).
DIP Switch Setting for OUTPUT| The type of output (current or voltage signal) has to be set by the DIP switch (see Fig.5).
For programming of DIP switch the user needs to open the transducer housing & set the DIP switch located on the PCB to the desired output type Voltage or Current. Output range changing is not possible with the DIP switch setting.
Refer to Fig. 5 for the DIP switch setting.
The four-pole DIP switch is located on the PCB in the Theta Transducer
DIP Switch Setting | Type of Output Signal |
---|
ONIIII
1234
| ****
load-independent current
ONIIII
Fig. 5 1234
| ****
load-independent voltage
Ordering Information