MAJESTIC Meridian 36 Direct Vent Gas Fireplace Instruction Manual

June 13, 2024
Majestic

MAJESTIC-LOGO

MAJESTIC Meridian 36 Direct Vent Gas Fireplace

MAJESTIC-Meridian-36-Direct-Vent-Gas-Fireplace-PRODUCT

Product Information

The Meridian 36 Direct Vent Gas Fireplace is a high-quality gas fireplace designed for efficient heating and aesthetic appeal. It has the following specifications:

  • Front Width: 41 inches
  • Height: 40-7/8 inches
  • Depth: 21-7/16 inches
  • Glass   Size: 34-1/4 x 24-3/4 inches
  • BTU/Hour Input: 16,000 – 30,000 BTUs (Natural Gas), 17,000 – 28,000 BTUs (Liquid Propane)
  • Weight: 163 lbs

Product Usage Instructions

To ensure proper usage of the Meridian 36 Direct Vent Gas Fireplace, please follow these instructions:

  1. Refer to the installation manual for the final dimensions and requirements.
  2. For basic corner installation, adjust framing dimensions for interior chase sheathing, such as sheetrock.
  3. For venting scenarios and additional information, refer to the installation manual.
  4. If using heat management, please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances.
  5. Ensure that the vent framing hole is not packed with insulation or other material.
  6. Consult the installation and owner’s manual for information on venting, TV clearances, finishing requirements, and fronts.
  7. For combustible mantel projections, refer to the provided measurement chart and adjust accordingly.
  8. For non-combustible mantel projections, refer to the provided measurement chart and adjust accordingly.
  9. Follow the exterior chase minimum height requirements for proper wall penetration.
  10. If top or rear venting is used, the center of the vent framing hole should be one inch above the center of the horizontal vent pipe.
  11. Note that if the overhang is less than 2 inches, the clearance from the top of the termination cap to the bottom of the overhang maybe 0 inches.

Dimension

MAJESTIC-Meridian-36-Direct-Vent-Gas-Fireplace-
FIG-2

FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR INPUT
---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 34-1/4″ x 24-3/4″ [870 X 629]| 16,000 – 30,000 BTUs (NG)

17,000 – 28,000 BTUs (LP)

FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR INPUT
---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 34-1/4″ x 24-3/4″ [870 X 629]| 16,000 – 30,000 BTUs (NG)

17,000 – 28,000 BTUs (LP)

MAJESTIC-Meridian-36-Direct-Vent-Gas-Fireplace-FIG-3

COMBUSTIBLE MANTEL PROJECTIONS

Note: Measurement is taken from the top of the opening, NOT the top of the fireplace.

NON-COMBUSTIBLE MANTEL PROJECTIONS

Note: Measurement is taken from the top of the opening, NOT the top of the fireplace.

COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONSMAJESTIC-Meridian-36-Direct-
Vent-Gas-Fireplace-FIG-6

Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

NON-COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS

Non-combustible Mantel Leg or Wall Projections (Acceptable on both sides of the opening)
If using heat management please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting, TV clearances, finishing requirements, fronts, etc can be found in the installation and owner’s manual

EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS

MAJESTIC-Meridian-36-Direct-
Vent-Gas-Fireplace-FIG-8

  • NOTE: If overhang (A) is less than 2 inches, clearance from the top of the termination cap to the bottom of overhang (B) may be 0 inches.
  • A – Measured from the back of the vent cap to the end of overhang
  • B – Measured from the bottom of the overhang to the top of the termination cap
  • Vinyl Siding Shield (TRAP-VSS) Information
  • TRAP-VSS is required if overhang (A) is greater than 3 inches but less than 5 inches and B dimension is less than 18 inches.
  • TRAP-VSS is recommended if either of the below is true:
  • Overhang (A) is less than 5 inches (to combat water infiltration)
  • A vinyl overhang is present

WALL PENETRATION

DO NOT PACK VENT FRAMING HOLES WITH INSULATION OR OTHER MATERIAL.

Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25 mm) above the center of the horizontal vent pipe.

PRODUCT LISTING CODES

US| ANSI Z21.88-2019
CAN| CSA 2.33-2019
| UL307B

The product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying the product to avoid the risk of fire and potential injury.
Majestic — A Brand of Hearth & Home Technologies 7571 215th Street West Lakeville, MN 55044
877-486-9123

Scan the QR code for the installation manual for the final dimensions and requirements.MAJESTIC-Meridian-36-Direct-Vent-Gas-Fireplace-
FIG-1 majesticproducts.com
majesticproducts.ca

Documents / Resources

| MAJESTIC Meridian 36 Direct Vent Gas Fireplace [pdf] Instruction Manual
Meridian 36 Direct Vent Gas Fireplace, Meridian 36, Direct Vent Gas Fireplace, Vent Gas Fireplace, Gas Fireplace, Fireplace
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals