Juniper Networks AP34 IEEE 802.11ax Radios Installation Guide
- June 13, 2024
- JUNIPER NETWORKS
Table of Contents
- Juniper Networks AP34 IEEE 802.11ax Radios
- Product Information
- AP34 Hardware Installation Guide
- I/O ports
- Recessed 9/16 inch T-bar or channel rail
- 1.5 inch T-bar
- Threaded rod adapter (1/2″, 5/8″, or M16)
- Technical Specifications:
- Warranty Information
- Mounting brackets
- Power Supply options
- Regulatory Compliance Information:
- FCC Requirement for Operation in the United States of America
- Industry Canada
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Juniper Networks AP34 IEEE 802.11ax Radios
Product Information
The Mist AP34 is a hardware device that is designed for wireless networking. It features four IEEE 802.11ax radios that deliver 2×2 MIMO with two spatial streams in both multi-user (MU) and single-user (SU) modes. The AP34 can operate simultaneously in the 6GHz band, 5GHz band, and 2.4GHz band, and it also includes a dedicated tri-band scan radio.
AP34 Hardware Installation Guide
Overview
The Mist AP34 contains four IEEE 802.11ax radios that deliver 2×2 MIMO with
two spatial streams when operating in multi-user (MU) or single-user (SU)
mode. The AP34 is capable of operating simultaneously in the 6GHz band, 5GHz
band, and 2.4GHz band along with a dedicated tri-band scan radio.
I/O ports
Reset
| ****
Reset to the factory default settings
---|---
Eth0+PoE
| 100/1000/2500/5000BASE-T RJ45 interface that supports 802.3at/802.3bt PoE PD
USB
| ****
USB2.0 support interface
AP34 Mounting
APBR-U Mounting box options
Holes Mounting options
- US Single gang, 4 inch round, 3.5 inch round
- US Double gang, Wall/ceiling mount
- US 4 inch square 4 EU unction box
In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head with a length at least 2 in. (50.8mm).
APBR-U is in the AP34 box which includes a set screw and an eyehook.
Mounting to a 9/16 inch or 15/16 inch T-bar
- Step1. Mount APBR-U to the t-bar
- Step2. Rotate APBR-U to lock to the t-bar
- Step3. Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US single gang, 3.5 or 4 inch round junction box
- Step 1 Mount APBR-U to the box using two screws and the #1 holes. Make sure Ethernet cable extends thru the bracket.
- Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US double gang junction box
- Step 1 Mount APBR-U to the box using two screws and the #2 holes. Make sure Ethernet cable extends thru the bracket.
- Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US 4 inch square junction box
- Step 1 Mount APBR-U to the box using two screws and the #3 holes. Make sure Ethernet cable extends thru the bracket.
- Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
EU unction box
- Step 1 Mount APBR-U to the box using two screws and the #4 holes. Make sure Ethernet cable extends thru the bracket.
- Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 15/16 inch T-bar
- Step 1 Mount the APBR-ADP-RT15 to the t-bar
- Step 2 Mount the APBR-U to the APBR-ADP-RT15. Rotate the APBR-U to lock to the APBR- ADP-RT15
- Step 3 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 9/16 inch T-bar or channel rail
- Step 1 Mount the APBR-ADP-CR9 to the t-bar
- Step 2 Mount the APBR-U to the APBR-ADP-CR9. Rotate the APBR-U to lock to the APBR- ADP-CR9 Step 3 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
1.5 inch T-bar
- Step 1 Mount the APBR-ADP-WS15 to the t-bar
- Step 2 Mount the APBR-U to the APBR-ADP-WS15. Rotate the APBR-U to lock to the APBR-ADP-WS15
- Step 3 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Threaded rod adapter (1/2″, 5/8″, or M16)
- Step 1 Install the APBR-ADP-T12 to the APBR-U. Rotate to lock.
- Step 2 Secure the APBR-ADP-T12 to the APBR-U with the provided screw
- Step 3 Install the bracket assembly to the 1/2″ threaded rod and secure with the provided lock washer and nut.
- Step 4 Slide the AP with shoulder screws on the APBR-U until the lock is engaged The same instructions work for the APBR-ADP-T58 or APBR-ADP-M16
Technical Specifications:
Feature
|
Description
---|---
Power options| 802.3at/802.3bt PoE
Dimensions| 230mm x 230mm x 50mm (9.06in x 9.06in x 1.97in)
Weight| AP34: 1.25 kg (2.74 lbs)
Operating temperature| AP34: 0° to 40° C
Operating humidity| 10% to 90% maximum relative humidity, non-condensing
Operating altitude| 3,048m (10,000 ft)
Electromagnetic emissions| FCC Part 15 Class B
I/O| 1 – 100/1000/2500/5000BASE-T auto-sensing RJ-45 with PoE USB2.0
RF
| 2.4GHz – 2×2:2SS 802.11ax MU-MIMO & SU-MIMO
5GHz – 2×2:2SS 802.11ax MU-MIMO & SU-MIMO
6GHz – 2×2: 2SS 802.11ax MU-MIMO & SU-MIMO
2.4GHz / 5GHz /6GHz scanning radio 2.4GHz BLE
Maximum PHY rate| Total maximum PHY rate – 4175 Mbps
6GHz – 2400 Mbps
5GHz – 1200 Mbps 2.4GHz – 575 Mbps
Indicators| Multi-color status LED
Safety standards
| UL 62368-1
CAN/CSA-C22.2 No. 62368-1-14
UL 2043
ICES-003:2020 Issue 7, Class B (Canada)
Suitable for use in environmental air space in accordance with Section 300-22(C) of the National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Warranty Information
The AP34 family of Access Points comes with a limited lifetime warranty.
Ordering Information:
Access Points
AP34-US | 802.11ax 6E 2+2+2 – Internal Antenna for the US Regulatory domain |
---|---|
AP34-WW | 802.11ax 6E 2+2+2 – Internal Antenna for the WW Regulatory domain |
Mounting brackets
APBR-U| Universal AP Bracket for T-Rail and Drywall mounting for Indoor Access
Points
---|---
APBR-ADP-T58| Adapter for 5/8-inch threaded rod bracket
APBR-ADP-M16| Adapter for 16mm threaded rod bracket
APBR-ADP-T12| Adapter for 1/2-inch threaded rod bracket
APBR-ADP-CR9| Adapter for channel rail and recessed 9/16” t-rail
APBR-ADP-RT15| Adapter for recessed 15/16″ t-rail
APBR-ADP-WS15| Adapter for recessed 1.5″ t-rail
Power Supply options
802.3at or 802.3bt PoE power
Regulatory Compliance Information:
This product and all interconnected equipment must be installed indoors within
the same building, including the associated LAN connections as defined by the
802.3at Standard.
Operations is restricted to indoor usage only.
If you need further assistance with purchasing the power source, please
contact Juniper Networks, Inc.
FCC Requirement for Operation in the United States of America
FCC Part 15.247, 15.407, 15.107, and 15.109
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance between the radiator & your body; AP34 – 41cm.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
- Professional installation is required.
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- FCC regulations restrict the operation of this device to indoor use only.
- The 5.925 ~ 7.125GHz operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet.
- Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or Communications with unmanned aircraft systems.
Industry Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
IC Caution
- The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
- Operation shall be limited to indoor use only.
- Operation on oil platforms, cars, trains, boats and aircraft shall be prohibited except for on large aircraft flying above 10,000 ft.
Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Hereby, Juniper Networks, Inc. declares that the radio equipment type (AP34)
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following: https://www.mist.com/support/
The frequency and maximum transmitted Power in EU:
Bluetooth:
Frequency range (MHz)|
Maximum EIRP in EU (dBm)
---|---
2400 – 2483.5| 9.96
WLAN
Frequency range (MHz)
|
Maximum EIRP in EU (dBm)
---|---
2400 – 2483.5| 19.99
5150 – 5250| 22.97
5250 – 5350| 22.97
5500 – 5700| 27.48
5745 – 5825| 13.96
5945 – 6425| 22.99
This equipment complies with EU radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
The device is restricted to indoor use only when operating in 5150 to 5350 MHz
and 5945 to 6425MHz frequency ranges.
| AT| BE| BG| CZ| DK| EE| FR| DE| IS
---|---|---|---|---|---|---|---|---|---
IE| IT| EL| ES| CY| LV| LI| LT| LU
HU| MT| NL| NO| PL| PT| RO| SI| SK
TR| FI| SE| CH| HR| UK(NI)| |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>