KEYSTONE KT-ALED210 LED Area Light Fixtures Instruction Manual

June 13, 2024
Keystone

KEYSTONE KT-ALED210 LED Area Light Fixtures Instruction Manual
LED Area Light Fixtures

DESCRIPTION

210W Optic Swap LED Area Light | 120–277V Input | Bronze Housing | Multiple Mounting, Optics, and Control options

APPLICATION

Pole-mount or structure-mount outdoor illumination needs (including parking lots, auto dealerships, pathways, roadways, recreational venues, and other general area lighting requirements)

PRODUCT FEATURES

  • Innovative optic swap capability under door frame and latch design for quick lens change
  • Two lenses in the box: Type III installed, Type V included
  • Type II and Type IV lenses sold separately. See below for details
  • Heavy duty die cast aluminum housing with ample heat sinking
  • Low-profile design delivers high-performance illumination and improves application site aesthetics
  • True U0 design for dark sky friendly performance eliminates undesirable sky glow
  • Integrated NEMA/ANSI C136.10 3-pin twist-lock receptacle with shorting cap, standard on all fixtures, simplifies ordering requirements for photo control needs
  • Four contractor-friendly mounting options available (sold separately): slip fitter mount, adjustable pole mount for square and round poles, fixed pole mount for square and round poles, and trunnion mount
  • Keystone 0-10V dimming driver
  • Ambient operating temperature: −40°C/−40°F to 50°C/122˚F
  • UL Certified; IP65 rated
  • Power factor: > 0.95
  • THD: < 20%
  • LED chip lifetime: L70 > 100,000 hrs @ 25C°/77°F ambient fixture temperature
  • Meets FCC Part 15, Part B, Class A standards for conducted and radiated emissions

PRODUCT SPECIFICATIONS

Catalog No.| Wattage| CCT| Lumens| Efficacy| Input Voltage| Dimming| CRI| Distribution Pattern| Photocell Included| Housing Color| Legacy Equivalent
---|---|---|---|---|---|---|---|---|---|---|---
KT-ALED210-L2-OSA-NM-840-VDIM| **** 210W| 4000K| **** 31710| **** 151 lm/W| **** 120-277V| **** 0-10V| **** >80| **** Type III Installed, Type V IncludedTypes II and IV Available,Sold Separately| **** No| **** Bronze| **** 750W MH
KT-ALED210-L2-OSA-NM-850-VDIM| 5000K

  • For more information, see Accessories page below or contact Keystone with questions.
  • Fixtures (and mounts) with alternate housing colors are available and made to order. Extended lead times apply.
  • Please see catalog number breakdown for full ordering code details.

PHYSICAL SPECIFICATIONS

LED AREA LIGHT FIXTURE
Dimension
PACKAGING

Carton Quantity: 1 piece
Carton Dimensions: 5.63″H × 15.95″W × 26.18″L
Carton Weight : 17.53 lbs

POLE MOUNT (ADJUSTABLE OR FIXED) DRILLING HOLE

**

Dimension
WIRING DIAGRAM
**

Waring Diagram

LIGHT DISTRIBUTION PATTERN

TYPE III (3)
Pole mount view from above. Area light mounted at 30 ft. Each square is 10 ft x 10 ft

Graph Function
TYPE V (5)
Pole mount view from above. Area light mounted at 30 ft. Each square is 10 ft x 10 ft
Graph Function

PHOTOMETRIC SPECIFICATIONS (TYPE II [2])

ISOCANDELA PLOT
Graph
Point of Max Cd: 15468.9

  • Cd: 13885, 90%
  • Cd: 11571, 75%
  • Cd: 9257, 60%
  • Cd: 7714, 50%
  • Cd: 6171, 40%
  • Cd: 4628, 30%
  • Cd: 3086, 20%
  • Cd: 1543, 10%

POLAR CANDELA DISTRIBUTION
Graph

  • Max CD: 75° H
  • ****: 0° H
  • ****: 90° H
  • ****: 45° H

FLUX DISTRIBUTION

Zone Lumens % Luminaire

Forward Light
0°-30°| 4645.5| 15.4%
30°-60°| 13102.6| 43.4%
60°-80°| 5053.1| 16.7%
80°-90°| 149.1| 0.5%
Back Light
0°-30°| 1721.7| 5.7%
30°-60°| 3222.6| 10.7%
60°-80°| 2145.9| 7.1%
80°-90°| 141.3| 0.5%
Up Light
90°-100°| 0.0| 0.0%
100°-180°| 0.0| 0.0%
Total| 30181.8| 100.0%
BUG Rating| B3-U0-G3

PHOTOMETRIC SPECIFICATIONS (TYPE III [3])

ISOCANDELA PLOT
Graph

Point of Max Cd: 15720.3

  • Cd: 14078, 90%
  • Cd: 11732, 75%
  • Cd: 9385, 60%
  • Cd: 7821, 50%
  • Cd: 6257, 40%
  • Cd: 4693, 30%
  • Cd: 3128, 20%
  • Cd: 1564, 10%\

POLAR CANDELA DISTRIBUTION
Graph

  • ****: 0° H
  • ****: 90° H
  • ****22.5° H
  • ****: 45° H
  • 67.5° H

FLUX DISTRIBUTION

Zone Lumens % Luminaire

Forward Light
0°-30°| 3146.5| 10.4%
30°-60°| 13036.4| 43.1%
60°-80°| 7415.8| 24.5%
80°-90°| 389.8| 1.3%
Back Light
0°-30°| 1490.2| 4.9%
30°-60°| 2770.5| 9.2%
60°-80°| 1779.6| 5.9%
80°-90°| 184.0| 0.6%
Up Light
90°-100°| 0.0| 0.0%
100°-180°| 0.0| 0.0%
Total| 30212.8| 100.0%
BUG Rating| B3-U0-G3

PHOTOMETRIC SPECIFICATIONS (TYPE IV [4])

ISOCANDELA PLOT
Graph

Point of Max Cd: 14317.6

  • Cd: 12808, 90%
  • Cd: 10674, 75%
  • Cd: 8539, 60%
  • Cd: 7116, 50%
  • Cd: 5693, 40%
  • Cd: 4269, 30%
  • Cd: 2846, 20%
  • Cd: 1423, 10%

POLAR CANDELA DISTRIBUTION
Graph

  • ****0° H
  • ****: 90° H
  • ****: 22.5° H
  • ****: 45° H
  • : 67.5° H

FLUX DISTRIBUTION

Zone Lumens % Luminaire

Forward Light
0°-30°| 3088.3| 10.4
30°-60°| 11006.4| 37.0%
60°-80°| 8165.8| 27.4%
80°-90°| 421.9| 1.4%
Back Light
0°-30°| 1876.0| 6.3%
30°-60°| 3296.1| 11.1%
60°-80°| 1778.4| 6.0%
80°-90°| 124.2| 0.4%
Up Light
90°-100°| 0.0| 0.0%
100°-180°| 0.0| 0.0%
Total| 29757.1| 100.0%
BUG Rating| B3-U0-G4

PHOTOMETRIC SPECIFICATIONS (TYPE V [5])

ISOCANDELA PLOT
Graph

Point of Max Cd: 6819.6

  • Cd: 6123, 90%
  • Cd: 5102, 75%
  • Cd: 4082, 60%
  • Cd: 3401, 50%
  • Cd: 2721, 40%
  • Cd: 2041, 30%
  • Cd: 1361, 20%
  • Cd: 680, 10%

POLAR CANDELA DISTRIBUTION
Graph

  • Max Cd : 112.5° H
  • ****0° H
  • ****90° H
  • ****22.5° H
  • ****: 45° H
  • : 67.5° H

FLUX DISTRIBUTION

Zone Lumens % Luminaire

Forward Light
0°-30°| 1884.2| 6.2%
30°-60°| 5994.5| 19.8%
60°-80°| 5666.7| 18.8%
80°-90°| 1182.9| 3.9%
Back Light
0°-30°| 1972.8| 6.5%
30°-60°| 6415.5| 21.2%
60°-80°| 6150.1| 20.4%
80°-90°| 941.3| 3.1
Up Light
90°-100°| 0.0| 0.0%
100°-180°| 0.0| 0.0%
Total| 30208.0| 100.0%
BUG Rating| B5-U0-G5

EPA SPECIFICATIONS

Large-Size Fixture Housing
Conditions: Horizontal winds only for calculations. Worst case total projected area used for calculations. All drag coefficients are set as worst case 1.2. For details on exact EPA calculations and assumptions, please contact productsupport@keystonetech.com

EPA Calcs (1.2*ft^2 | View)| **Single Fixture

| 2 Fixtures at 90º| 2 Fixtures at 180º| 3 Fixtures at 90º| 3 Fixtures at 120º| 4 Fixtures at 90º| 2 Fixtures Side-by-Side| 3 Fixtures Side-by-Side| 4 Side
Fix-by
tur-Sies de
| | |
---|---|---|---|---|---|---|---|---|---|---|---|---
Mounting Application| Fixture Position| | | | | | Fixture
Housing| | | | | |
| | | | |
| | |
Adjustable Pole Mount

**|

Horizontal

|

0.62 sq. ft.

|

0.90 sq. ft.

|

1.24 sq. ft.

|

1.42 sq. ft.

|

1.48 sq. ft.

|

1.42 sq. ft.

|

0.74 sq. ft.

|

1.11 sq. ft.

|

|

48

|

sq.

|

ft.

Adjustable Pole **Mount

**|

45º

|

1.85 sq. ft.

|

2.43 sq. ft.

|

1.85 sq. ft.

|

3.01 sq. ft.

|

4.42 sq. ft.

|

3.01 sq. ft.

|

3.70 sq. ft.

|

5.55 sq. ft.

|

|

40

|

sq.

|

ft.

Slip Fitter **Mount

**|

Horizontal

|

0.60 sq. ft.

|

0.98 sq. ft.

|

1.20 sq. ft.

|

1.53 sq. ft.

|

1.57 sq. ft.

|

1.53 sq. ft.

|

0.86 sq. ft.

|

1.30 sq. ft.

|

|

73 s

|

q.

|

t.

Slip Fitter **Mount

**| 45º|

1.92 sq. ft.

|

2.51 sq. ft.

|

1.92 sq. ft.

|

3.09 sq. ft.

|

4.39 sq. ft.

|

3.09 sq. ft.

|

3.84 sq. ft.

|

5.76 sq. ft.

|

|

68

|

sq.

|

ft.

Slip Fitter **Mount

**|

Vertical

|

2.59 sq. ft.

|

3.19 sq. ft.

|

2.59 sq. ft.

|

3.80 sq. ft.

|

4.07 sq. ft.

|

3.80 sq. ft.

|

5.18 sq. ft.

|

7.77 sq. ft.

|

|

35

|

sq.

|

ft.

ACCESSORIES (SOLD SEPARATELY)

SENSORS
Factory-Installable OR Field-Installable (field-installable purchased separately)

**SUFFIX*** CATALOG NUMBER DESCRIPTION UPC EASY CODE
/3PN KT-TLP-UV-3PN NEMA Type Twist-Lock 3-Pin Photocell 120–277V, 1800VA
Max; Blue Housing 843654131825 NQT-46
/7PRS KT-RSC-7PN NEMA Type 7-Pin Receptacle and Shorting Cap 843654135205

BIZ-08
/MW3| KTS-MW3-12V-PKO| 12V Microwave Occupancy Sensor| 843654130637| TRM-32
/FC3| KTSL-FC3-12V-PKO- PIR| Bluetooth mesh wireless Smart Port LED controller for SmartLoop system with integrated daylight and PIR motion sensor.| 843654138862| OCW-60
/FC4| KTSL-FC4-12V-PKO| Bluetooth mesh wireless screw-in low voltage fixture controller for SmartLoop system| 843654149066| RUN-10

  • Twist-Lock Area Light Control KT-TLP-UV-3PN

  • Twist-Lock Area Light Control KT-RSC-7PN
    Light Control

  • Microwave Occupancy Sensor KTS-MW3-12V-PKO

  • Smart Port LED Controller KTSL-FC3-12V-PKO-PIR
    Smart Port LED Controller

  • Screw-In Fixture Controller KTSL-FC4-12V-PKO

For factory installation of accessory, add suffix to fixture part number (see ordering examples and instructions on last page of spec sheet).

Field-Installable / Field-Use ONLY (purchased separately)

CATALOG NUMBER DESCRIPTION UPC EASY CODE
KTS-MW3-REMOTECONTROL Remote Control for KTS-MW3-12V-XX Sensors, Sets/adjusts
all sensor performance parameters 843654132020 XSR-61

Remote Control KTS-MW3-REMOTECONTROL

Fiel -Installable / Field-Use ONLY (purchased separately)

CATALOG NUMBER DESCRIPTION UPC EASY CODE
KT-ALED-LENS-L2-2-KIT Type II Optics Lens for CCT Dedicated, Large Size
Housing, Series 2 Area Lights 843654153841 NFU-40
KT-ALED-LENS-L2-4-KIT Type IV Optics Lens for CCT Dedicated, Large Size
Housing, Series 2 Area Lights 843654153889 BSU-72
  •   Lenses
    KT-ALED-LENS-L2-2-KIT

  • Lenses
    KT-ALED-LENS-L2-4-KIT

For factory installation of accessory, add suffix to fixture part number (see ordering examples and instructions on last page of spec sheet).

ACCESSORIES (SOLD SEPARATELY)

MOUNTS AND BRACKETS
Field-Installable / Field-Use ONLY
(purchased separately)

CATALOG NUMBER DESCRIPTION UPC EASY CODE
KT-ALED-GS-L2-KIT Reversible Glare Shield for Large Size Housing, Series 2
Area Lights, Bronze 843654153810 RDW-18
KT-ALED-SF-1-KIT Slip Fitter Mount, Fits 2 3/8” tenon; Bronze 843654131641

JRH-74
KT-ALED-PMA-1-KIT| Adjustable Pole Mount, For round or square pole; Bronze| 843654131634| DAQ-87
KT-ALED-PM-1-KIT| Fixed Pole Mount, For round or square pole; Bronze| 843654131627| QVG-29
KT-ALED-TM-1-KIT| Trunnion Mount, Bronze| 843654131658| GTH-37

  • Glare Shield KT-ALED-GS-L1-KIT
    Bracket

  • Slip Fitter Mount KT-ALED-SF-1-KIT

  • Adjustable Pole Mount KT-ALED-PMA-1-KIT
    Bracket

  • Fixed Pole Mount KT-ALED-PM-1-KI
    Bracket

  • Trunnion Mount KT-ALED-TM-1-KIT

Bracket

ORDERING INFORMATION

ORDER CODE| PACK QTY.| UPC| Easy Code| DLC PRODUCT ID
---|---|---|---|---
KT-ALED210-L2-OSA-NM-840-VDIM| 1| 843654153025| XPH-40| S-BWOVAS
S-VBMIXS
KT-ALED210-L2-OSA-NM-850-VDIM| 1| 843654153032| NYP-51| S-UB92M0
S-ERQY4I

CATALOG NUMBER BREAKDOWN

  1. Keystone Technologies
  2. Area Light
  3. LED Technology
  4. Wattage
  5. Size/Shape
  6. Style/Design Designation
  7. Optic Swap
  8. Optic Swap Designation
  9. No Mounting
  10. 80 CRI
  11. CCT
  12. 0-10V Dimming

7 Optic Swap Designation
A Type III lens installed, Type V lens included

ORDERING EXAMPLES

FIXTURE WITH SINGLE FACTORY-INSTALLED ACCESSORY
KT-ALED210-L2-OSA-NM-8XX-VDIM /7PRS

FIXTURE WITH NO FACTORY-INSTALLED ACCESSORIES
KT-ALED210-L2-OSA-NM-8XX-VDIM

KEYSTONE FIXTURE
CATALOG NUMBER
KT-ALED210-L2-OSA-NM-8XX-VDIM

SENSORS

? SUFFIX CATALOG NUMBER
? /7PRS KT-RSC-7PN

When ordering more then one factory-installed accessory, use multiple suffixes as shown in the ordering examples above. Note: All accessories can also be ordered separately for field installation using just their regular Catalog Number, UPC, or Easy Code.

Keystone Technologies • Philadelphia, PA •
Phone 800-464-2680
www.keystonetech.com
Specifications subject to change. Last revised on 09.19.23

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals