Solar Outdoor Wireless Acousto-optic Siren ST-6109S

  • This product is a networking accessory that needs to be used with the company’s gateway
    Solar Outdoor Wireless Acousto-optic Siren User’s Manual

Brief Introduction

The solar outdoor wireless acousto-optic siren {hereafter called siren) adopts 8 bit MCU technology, built-in 8 LED lights, 2 105dB buzzers and 1 built-in lithium battery. Using solar energy to charge, without external power supply. It is  an entire wireless system. The siren not only can connect with the alarm host via wireless transmission, but also can be used as an alarm host and a repeater. It is widely used in banks, shops and villas etc.
When the siren works with wireless alarm host by wireless transmission, alarm host can input the siren’s address, or directly learning with the siren. The siren’s tamper alarm, AC information, battery voltage information are all transmitted to the alarm host via wireless signal. Then the alarm host notifies the user about the alarm information via SMS, center and voice .
The siren also can indicate alarm host arm I disarm status.
Users can buy the relative remote controls and detectors according to their demand when the siren is used as the alarm host. It can connect with these wireless accessories and become a powerful independent alarm system.
The siren can also be used as a repeater, which can increase the wireless launch distance effectively.

Main Features

  • Used as a repeater, it can transmit 16 wireless accessories.
  • 3 colors of indicator lights flashing modes. ( Red/ Bluel Red+Blue )
  • Design for preventing the siren being removed maliciously .
  • Acousto-optic notice when operating Arm /Disarm.
  • Status reports including the alarm from siren itself, tamper alarm
  • Support 8 remote controls, 16 detectors. The last 4 wireless zones for 24 hours defend.
  • Two optional ways to enroll: by trigger button or inputting siren address code.
  • 105dB alarm sound, flashing lights, a strong deterrent.
  • Built-in 5200mAh 3.7V 18650 lithium battery, up to 120days of stand-by time.
  • Built-in balance device, convenient to install in horizontal direction.

Interface definition

Operation Instruction

4.1.Remote Control
4.1.1. Enroll Remote Control
Step1: Under the normal status without alarm event, long press “SET” button with 3s until heard a short “Di” and red indicator light bright, it means the siren is in enrolling status, then user can start to enroll remote control, press any  button of remote control to enroll.
Step2: If user wants to enroll the next remote control, please press “NEXT” button to the next one.
Attention: If the red indicator light is flashing, it means the current remote control has not been enrolled and user can press any button of remote control to enroll. If enrollment succeeded, the siren will prompt a short “Di”, meanwhile  red indicator light will turn flashing into long bright, it means remote control enrollment succeed. If the red indicator light is long bright, it means the current address has been already enrolled. User should delete previous one to re- enrolling. If heard 5 short “Di”, it means the remote control has already been enrolled.
4.1.2. Delete Remote Control
In remote control enrolling status, press “NEXT” button with 3s to delete the existing remote control. After user heard 2 short “Di” from siren and the indicator turned long bright into flashing, deletion is successful.
4.1.3. Exit Remote Control Enrollment
In remote control enrolling status, short press “SET” button twice to exit.
4.2.Detector
4.2.1.Enroll Detector
Step 1: Under remote controller enrolling status, short press “SET” button once, blue indicator light bright, it means the siren is in enrolling status, then user can start to enroll detectors.
Step2: If user wants to enroll the next detector, please short press “NEX ” button to the 2″‘ detector.
Attention: If the current blue indicator light is flashing, it means the current detector has not yet been enrolled and user can enable T detector to transmit alarm signal to be enrolled. If enrollment succeeded, siren will prompt a short  “Di”, meanwhile blue indicator light will tum flashing into long bright, it means successful enrollment of detector. If the current blue indicator light is long bright, it means the current detector has been already enrolled. User should delete previous one before re-enrolling. If heard 5 short “Di”, it means the detector has already been enrolled.
4.2.2.Delete Detector
In detector enrolling status, press “NEX” button with 3s to delete the existing detector. After user heard 2 short “Di” and the blue indicator light turned long bright into flashing, deletion is successful.
4.2.3. Exit Detector Enrollment
In detector enrolling status, short press “SET’ button once to exit.

4.3. Arm/Disarming Prompt Voice
4.3.1 Entering Arm/Disarming Prompt Voice status
Under the “Detector Enrollment Status”, short press “SET” button once, the alarm enters the setting status of “Arm/Disarming Prompt Voice”, and the red and blue indicator lighing. Short press “NEXT” to set.When the indicator is lighting ON(not flashing), ii means the “Arm/Disarming Prompt Voice” with “LED indication” is activated; When the indicator light is slow flashing, it means the “Arm/Disarming Prompt Voice” (but without “LED indication”) is  activated; When the indicator light is fast flashing; it means the “Arm/Disarming Prompt Voice” and “LED indication” is totally disabled. It means arm/disarm when red light flashes.has light indicator remind, no sound remind 4.3.2 Exit “Arm/Disarming Prompt Voice” setting mode.
Under the “Arm/Disarming Prompt Voice” setting mode status, short press “SET” button twice,

4.4. LED indication setting in Armed status
4.4.1 Entering LED indication setting in Armed status
Under the “Arm/Disarming Prompt Voice Status”, short press “SET” button once, the alarm enters the setting status of “LED indication setting in Armed status”, and the red indicator lighing. Short press “NEXT” to set.When the indicator  is lighting ON(not flashing), it means the “LED indication setting in Armed status” is activated (in Armed status the LED flash 1 times/5 seconds);When the indicator light is fast flashing, it means the “LED indication setting in  Armed status” is disabled.
4.4.2 Exit “LED indication setting in Armed status” setting mode.
Under the “LED indication setting in Armed status” mode status, short press “SET” button once.
4.5.Enroll Siren
Under siren standby status, short press “ENROLL” button once, siren will emit wireless enrolled signal to host, then alarm host enter siren enrolled status, when user hear a short “Di” from alarm host, it means siren enrollment succeed.
4.6. Repeater
4.6.1.Enroll Repeater
Step1: Long pressing “SET” and “NEXT’ buttons for 3 seconds at the same time, after hearing a short “Di”, the siren enters the repeater enrollment. The red and blue indicator light bright refers to the current repeater which need be transmitted is enrolled.
Step2: If user wants to enroll the next one, please short press “NEXT’ button to the 2″‘ repeater.
Attention: If the current red and blue indicator light is flashing, it means the current repeater has not yet been enrolled and user can trigger the repeater. If enrollment succeeded, siren will prompt a short “Di”, meanwhile red and blue  indicator light will turn flashing into long bright, it means successful enrollment of repeater. If the red and blue indicator light is long bright, it means the current repeater has been already enrolled. User should delete previous one before  re-enrolling. If heard 5 short “Di”, it means the repeater has already been enrolled.
4.6.2.Delete Repeater
In repeater enrolling status, press “NEXT” button with 3s to delete the existing repeater. After user heard 2 short “Di” and the blue indicator light turned long bright into flashing, deletion is successful.
4.6.3.Exlt Repeater Enrollment
In repeater enrolling status, short press “SET’ button once to exit.
4.7. Copy the siren address
4.7.1. Copy the siren address
Press the “ENROLL” and “NEXT” keys for 3 seconds at the same time, hear the one short “beep” , enter the copy alarm address status, and red and blue light of siren is on. If the red and blue indicator is flashing, it means the factory  address. Then long press the “ENROLL” button , short press “ENROLL” button of the siren which you want to copy; if the copy is successful, the alarm will prompt one short “Beep”, while the alarm red and blue indicator will stop flashing into a long light, suggesting that the transponder replication is successful; if the alarm red and blue indicator is long bright, indicating that the current address of the siren has been copied, the user must deleting first and then you can re- copy.
4. 7 .2. Delete the copy siren address
Press the “NEXT” key for 3 seconds to clear the copy address of siren and return to the factory address, and will prompt the two short “beep” and the siren red and blue indicator changes from long bright to Flash, indicate delete success.
4.7.3. Exit the copy siren address
In the copy siren address state, short press “SET” key , will exit the copy siren address state.
4.8. Recovery Factory Default
In stand-by status, long press “SET’ and “ENROLL”, until hear 2 short “Di”, It means that the siren has been back to factory default.

Technical parameter

Size specification: 320mm • 210mm • 114mm •(length• width• thickness) Battery: 3.7V 5200mAh 18650 lithium battery
Alarm current: ,s;;4oomA Stand-by time: ,s;;120 days (without sunlight) Siren alarm sound: 105dB
Wireless Working Frequency: 433.92MHz Use environment: working temperature -20-C-+55-C relative humidity 40 -80%
Wireless Emitting Distance: ,s;;400 ( in the open area)
Wireless Receiving Distance: ,s;;350 (in the open area)

6109S user manual V1 .1
2021.12.20

Read User Manual Online (PDF format)