SEALEVEL 2161 SeaLINK+16/232.RJ Serial Interface Adapter User Manual
- June 13, 2024
- SEALEVEL
Table of Contents
- SEALEVEL 2161 SeaLINK+16/232.RJ Serial Interface Adapter
- Product Information
- Other Sealevel USB Serial I/O Products
- Product Usage Instructions
- Optional Items
- Introduction
- Installation & Configuration
- Hardware Installation
- Technical Description
- Electrical Characteristics
- Specifications
- Appendix A – Troubleshooting
- Appendix B – How To Get Assistance
- Appendix C – Electrical Interface
- Appendix D – Asynchronous Communications
- Appendix E – Silk-Screen
- Appendix F – Compliance Notices
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SEALEVEL 2161 SeaLINK+16/232.RJ Serial Interface Adapter
Product Information
The Sealevel Systems SeaLINK+16/232.RJ (Item# 2161) is a USB device that equips the PC with 16 RS232 Asynchronous serial ports that support TX, RX, RTS, and CTS and data rates up to 115.2K baud. The SeaLINK+16/232.RJ also provides two USB 1.1 downstream ports (fully rated at 500 mA per port) for conveniently connecting additional SeaLINK+16/232.RJ devices or other USB peripherals. The SeaLINK+16/232.RJ is designed to be used with a variety of Operating Systems including Windows 98/ME/2000/XP. The SeaCOM API (Application Programmer Interface), which can be downloaded from the Sealevel download database, provides a variety of useful high-level function calls implemented as a Windows dynamic link library (DLL). In addition to the API, SeaCOM includes sample code and utilities to simplify software development.
Other Sealevel USB Serial I/O Products
- SeaLINK+232 (P/N 2101): 1 Port RS-232 DB25
- SeaLINK+232 (P/N 2105): 1-Port RS-232 DB9
- SeaLINK+485 (P/N 2102): 1-Port RS-422/485/530
- SeaLINK+232I (P/N 2103): 1-Port Isolated RS-232
- SeaLINK+485I (P/N 2104): 1-Port Isolated RS-422/485/530
- SeaLINK+2/232 (P/N 2201): 2-Port RS-232
- SeaLINK+2/485 (P/N 2202): 2-Port RS-422/485
- SeaLINK+2 (P/N 2203): 2-Port RS-232/422/485
- SeaLINK+2/232.PC (P/N 2208): 2-Port RS-232 Box Header
- SeaLINK+4/232 (P/N 2401): 4-Port RS-232
- SeaLINK+4/485 (P/N 2402): 4-Port RS-422/485
- SeaLINK+4 (P/N 2403): 4-Port RS-232/422/485
- SeaLINK+8/232 (P/N 2801): 8-Port RS-232
- SeaLINK+8/485 (P/N 2802): 8-Port RS-422/485
- SeaLINK+8 (P/N 2803): 8-Port RS-232/422/485
- SeaLINK+16.VC (P/N 2167): 16-Port RS-232/485 VersaCom
Product Usage Instructions
**Before You Get Started:
**
What’s Included:
The SeaLINK+16/232.RJ is shipped with the following items. If any of these
items is missing or damaged, please contact Sealevelfor replacement.
- SeaLINK+16/232.RJ device
- Power adapter
- USB cable
- User manual
- Item#2161 – SeaLINK+16/232.RJ USB 16-Port Serial Device
- Item# CA179 – 72” USB “A” to ‘B’ Device Cable
- Item# TR101 – 5VDC @ 3A Power Supply
- Item# LB116 – RS-232 RJ45 Serial Loopback
Advisory Conventions:
Warning: The highest level of importance used to stress a condition
where damage could result to the product, or the user could suffer serious
injury.
Important: The middle level of importance used to highlight information
that might not seem obvious or a situation that could cause the product to
fail.
Note: The lowest level of importance used to provide background
information, additional tips, or other non-critical facts that will not affect
the use of the product.
Optional Items
Depending upon your application, you are likely to find one or more of the
following items useful for interfacing the SeaLINK+16/232.RJ. All items can be
purchased from our website
(http://www.sealevel.com) or by calling
864-843-4343.
-
Modular adapter for RJ45 to DB9 male RS-232 serial port
-
Modular adapter for RJ45 to DB25 male RS-232 serial port
-
DB9 Male to RJ45 Modular Adapter (Item# RJ9P-232)
Preconfigured for use with the SeaLINK+16/232.RJ, this modular adapter converts the RJ45 RS-232 pinout from the SeaLINK+16/232.RJ to a DB9 male RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial port up to 50 feet away from the SeaLINK+16/232.RJ. -
DB25 Male to RJ45 Modular Adapter (Item# RJ25P-232)
Preconfigured for use with the SeaLINK+16/232.RJ, this modular adapter converts the RJ45 RS-232 pinout from the SeaLINK+16/232.RJ to a DB25 male RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial port up to 50 feet away from the SeaLINK+16/232.RJ. -
DB9 Male to RJ45 Modular Adapter (Item# RJ9P8)
The RJ9P8 includes an RJ45 connector and converts it to a DB9 Male connector, which allows the use of standard twisted pair cabling. The RJ9P8 ships unassembled and can be configured for virtually any pin out. -
DB25 Male to RJ45 Modular Adapter (Item# RJ25P8)
The RJ25P8 includes an RJ45 connector and converts it to a DB25 Male connector, which allows the use of standard twisted pair cabling. The RJ25P8 ships unassembled and can be configured for virtually any pin out. -
USB ‘A’ to ‘A’ Extension Cable, 3 Meters in Length (Item# CA214)
The CA214 is a fully rated USB extension cable that allows adding 3 meters (USB maximum of 5 meters) to any existing USB cable. The cable has a type ‘A’ male connector on one end and a type ‘A’ female connector on the other end. -
RJ45 Patch Cable, 7’ in Length (Item# CA246)
Standard 7’ CAT5 patch cable with one-to-one pinout. -
RJ45 Patch Cable, 10’ in Length (Item# CA247)
Standard 10’ CAT5 patch cable with one-to-one pinout.
Introduction
Overview
The Sealevel Systems SeaLINK+16/232.RJ (Item# 2161) is a USB device that
equips the PC with 16 RS-232 Asynchronous serial ports that support TX, RX,
RTS, and CTS and data rates up to 115.2K baud. The SeaLINK+16/232.RJ also
provides two USB 1.1 downstream ports (fully rated at 500 mA per port) for
conveniently connecting additional SeaLINK+16/232.RJ devices or other USB
peripherals. The SeaLINK+16/232.RJ is designed to be used with a variety of
Operating Systems including Windows 98/ME/2000/XP. The SeaCOM API (Application
Programmer Interface), which can be downloaded from the Sealevel download
database, provides a variety of useful high-level function calls implemented
as a Windows dynamic link library (DLL). In addition to the API, SeaCOM
includes sample code and utilities to simplify software development.
Installation & Configuration
Software Installation
Windows Installation
- Do not install the Adapter in the machine until the software has been fully installed.
- Only users running Windows 7 or newer should utilize these instructions for accessing and installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing support@sealevel.com to receive access to the proper driver download and installation instructions.
- Begin by locating, selecting, and installing the correct software from the Sealevel software driver database.
- Select the Part Number (2161) for your device from the listing.
- Click the ‘Install Drivers’ button.
- The setup file will automatically detect the operating environment and install the proper components.
To confirm that the SeaCOM driver has been successfully installed, click on the ‘Start’ button, and then select ‘All Programs’. You should see the ‘SeaCOM’ program folder listed. You are now ready to proceed with connecting the 2161 to your system. Refer to the Hardware Installation section for details.
Windows NT is not USB aware and thus cannot support this device.
Third Party Software Support
Third party software support for many HMI/MMI and other process control
software is also available from the Sealevel software database. For the most
up to date information on third party software support, please visit the 3rd-
Party Software Archives – Sealevel.
Hardware Installation
The SeaLINK+16/232.RJ can be connected to any spare USB port.
Do not connect the device to a USB port until the software has been fully
installed.
- Connect the SeaLINK+16/232.RJ to external power using the included TR101 power supply.
- Connect the SeaLINK+16/232.RJ to a USB port with the supplied CA179 USB device cable.
- The software drivers installed during setup will automatically recognize and configure the device.
- You should see one or more “New Hardware Found” windows, indicating the actual device being created. The installation will repeat twice for each COM port (a total of 32 times on the SeaLINK+16/232.RJ). This is a limitation in the way Windows installs external serial devices.
- Next, view your system’s Device Manager.
- You should have new COM: ports in the Ports (COM & LPT) Device Class indicating the installation was successful.
- You can access your new COM: port by using the assigned COM: identifier. This assignment will vary from system to system.
- To verify operation use Sealevel Systems supplied WinSSD diagnostic utility. WinSSD can be found in the Start, Programs group.
The SeaLINK+16/232.RJ is now ready for use.
Technical Description
The SeaLINK+16/232.RJ utilizes sixteen USB UARTs. These chips feature programmable baud rate, data format, 128-byte Dual Port TX Buffer, and 384-byte Dual Port RX Buffer. The RS-232 transceivers support data rates up to 115.2K bps.
Connector Pin Assignments (RJ45)
Signal | Name | Pin # | Mode |
---|---|---|---|
NC | No Connect | 1 | |
RTS | Request To Send | 2 | Output |
TX | Transmit Data | 3 | Output |
GND | Ground | 4 | |
NC | No Connect | 5 | |
RX | Receive Data | 6 | Input |
CTS | Clear To Send | 7 | Input |
NC | No Connect | 8 |
- DCD, DSR, and RI are inputs that are not brought out on the RJ45 connector. DSR and DCD are biased active, and RI is biased active, and RI is biased inactive.
Optional Items
RJ45 to DB9 RS-232 Adapter (Item# RJ9P-232)
Preconfigured for use with Sealevel 2161 and 2167 serial devices, the RJ45 to
DB9 modular adapter (item# RJ9P-232) converts the RJ45 RS-232 pin out to a DB9
male RS-232 serial port. Standard CAT5 patch cables can be used to extend the
serial port up to 50 feet away from the RJ45 port. The pin out for the
RJ9P-232 is shown below.
Electrical Characteristics
Features
- Supports front or rear rack mounting or desktop use
- Provides 16 RJ45 serial ports with status LEDs
- Includes two fully rated (500mA) USB 1.1 downstream ports
- Integrates transmit and receive LED indicators on each port
- Includes front and rear status LED to indicate unit power
- 9-30V input power option available for OEM volume opportunities
Specifications
Environmental Specifications
Specification | Operating | Storage |
---|---|---|
Temperature Range | 0º to 70º C | -50º to 105º C |
Power Requirements
Supply Line | +5 VDC |
---|---|
Rating | 2A |
Physical Dimensions
Package Length | 7.0 inches (17.78 cm) |
---|---|
Package Width ***** | 16.8 inches (42.56 cm) |
Package Height | 1.7 inches (4.32 cm) |
- Width excludes rack-mount ears.
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and
are 100% electrically tested. These printed circuit boards are solder mask
over bare copper or solder mask over tin nickel.
Appendix A – Troubleshooting
The adapter should provide years of trouble-free service. However, in the event that it appears to be functioning incorrectly, the following tips can eliminate most common problems without the need to call Technical Support.
- If your adapter isn’t working, first check to make sure that USB support is enabled in the System BIOS and it is functioning properly in the operating system. This can be done by using either the Windows 98/ME or Windows 2000 Device Manager.
- Ensure that the Sealevel Systems software has been installed on the machine so that the necessary files are in place to complete the installation.
- When the SeaLINK+16/232.RJ is configured properly, Sealevel’s WinSSD utility and a loopback plug can be used to check communications. You can make a simple Loopback in the field by connecting the TX and RX pins. If you decide to test the Modem Control Signals, a full pin loopback plug will be required. Details on loopback plugs are included within WinSSD. Contact Sealevel Systems if you need further assistance.
- When testing the SeaLINK+16/232.RJ in loopback mode, you should see both the TD and RD echoed as data on the screen. The loopback test first transmits a HEX pattern, 55AA, and then an ASCII string of data. If this test passes, then the SeaLINK+16/232.RJ is ready for use in your application.
- Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will eliminate any software issues from the equation.
If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 AM to 5:00 PM Eastern Time Monday through Friday. For email support contact support@sealevel.com.
Appendix B – How To Get Assistance
Please refer to: Appendix A — Troubleshooting Guide prior to calling Technical
Support.
Begin by reading through the Trouble Shooting Guide in Appendix A. If
assistance is still needed, please see below. When calling for technical
assistance, please have your user manual and current adapter settings. If
possible, please have the adapter installed in a computer ready to run
diagnostics. Sealevel Systems provides an FAQ section on its web site. Please
refer to this to answer many common questions. This section can be found at
http://www.sealevel.com/faq.asp. Sealevel Systems maintains a web page on
the Internet. Our home page address is
www.sealevel.com. The latest software updates, and
newest manuals are available via our web site.
Technical support is available Monday to Friday from 8:00 a.m. to 5:00 p.m.
eastern time. Technical support can be reached at
864-843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED
MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING
SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA)
NUMBER.
Appendix C – Electrical Interface
RS-232
Quite possibly the most widely used communication standard is RS-232. This
implementation has been defined and revised several times and is often
referred to as RS-232 or EIA/TIA-232. The IBM PC computer defined the RS-232
port on a 9 pin D sub connector and subsequently the EIA/TIA approved this
implementation as the EIA/TIA-574 standard. This standard is defined as the
9-Position Non-Synchronous Interface between Data Terminal Equipment and Data
Circuit-Terminating Equipment Employing Serial Binary Data Interchange. Both
implementations are in widespread use and will be referred to as RS-232 in
this document. RS-232 is capable of operating at data rates up to 20 Kbps at
distances less than 50 ft. The absolute maximum data rate may vary due to line
conditions and cable lengths. RS-232 is a single ended or unbalanced
interface, meaning that a single electrical signal is compared to a common
signal (ground) to determine binary logic states. The RS-232 and the
EIA/TIA-574 specification define two types of interface circuits, Data
Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The
IC485+ is a DCE device.
Appendix D – Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) are pre-defined and must correspond at both the transmitting and receiving ends. Asynchronous communications is the standard means of serial data communication for PC compatibles and PS/2 computers. The original PC was equipped with a communication or COM: port that was designed around an 8250 Universal Asynchronous Receiver Transmitter (UART). This device allows asynchronous serial data to be transferred through a simple and straightforward programming interface. A start bit, followed by a pre-defined number of data bits (5, 6, 7, or 8) defines character boundaries for asynchronous communications. The end of the character is defined by the transmission of a pre-defined number of stop bits (usually 1, 1.5 or 2). An extra bit used for error detection is often appended before the stop bits.
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications must be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e., 9600, N, 8, 1).
Appendix E – Silk-Screen
Appendix F – Compliance Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in such case the user
will be required to correct the interference at the user’s expense.
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive
(89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the
European Commission. To obey these directives, the following European
standards must be met:
- EN55022 Class A – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
- EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.
- This is a Class A Product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference.
- Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall
conform to and perform in accordance with published technical specifications
and shall be free of defects in materials and workmanship for the warranty
period. In the event of failure, Sealevel will repair or replace the product
at Sealevel’s sole discretion. Failures resulting from misapplication or
misuse of the Product, failure to adhere to any specifications or
instructions, or failure resulting from neglect, abuse, accidents, or acts of
nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and
providing proof of purchase. Customer agrees to ensure the Product or assume
the risk of loss or damage in transit, to prepay shipping charges to Sealevel,
and to use the original shipping container or equivalent. Warranty is valid
only for original purchaser and is not transferable. This warranty applies to
Sealevel manufactured Product. Product purchased through Sealevel but
manufactured by a third party will retain the original manufacturer’s
warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be provided in order to obtain an RMA
(Return Merchandise Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number. Please contact Sealevel Systems, Inc.
Technical Support for assistance:
Available Monday – Friday, 8:00AM to 5:00PM EST
Phone: 864-843-4343
Email: support@sealevel.com
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in
this manual are the service mark, trademark, or registered trademark of the
respective company.
© Sealevel Systems, Inc.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>