Stuv 30 Compact One Modern Wood Stoves Instruction Manual
- June 13, 2024
- Stuv
Table of Contents
Installation instructions
www.stuv.com
You can also find us on: For professional use
NZ
30-compact ONE
We recommend that you read the instructions before proceeding with the installation. With certain configurations, the sequence of operations to be performed may slightly vary.
PRESENTATION OF THE PRODUCT
Standards, certification and technical characteristics
IMPORTANT:
The Stûv 30-Compact ONE (NZ) is designed to function as a closed door wood
fire, suitable for installing on properties of less than 2 hectares, LEB areas
in New Zealand (Low Emission Burner).
THIS APPLIANCE MUST BE OPERATED IN GLASS DOOR/ CLOSED DOOR MODE – EXC Data
provided in this notice are supplied by a certified laboratory.
This appliance has been tested and certified by Spectrum Laboratory Ltd based
on the following standards:
AS/NZS 4012:2014
AS/NZS 4013:2014
AS/NZS 2918:2001
WARNING:
The appliance and flue-system must be installed in accordance with AS/NZS
2918:2001 and the relevant building code or codes.
Any modification of the appliance that has not been approved in writing by the
testing authority will be in breach of the approval granted for compliance
with AS/NZS 4013.
Once the flue has been installed and approved by a professional installer, the
flue must not be modified in any way.
The appliance must be bolted through the base to comply with the seismic
restraint provisions of AS/NZS 2918:2001.
Stûv 30-compact one is covered by the patent nr 1130323.
Weight and dimensions
System mass | 114 kg |
---|---|
Flue kit | 150 to ceiling/200/250mm |
Firebox dimensions | W465 x H1040 x D447mm |
Dertermined under test conditions
Nominal thermal output | 8 kW |
---|---|
Efficiency | 65% |
Emissions | 0,32 g/kg |
Fuel type
SOFTWOOD ONLY
Maximum length of logs in vertical position| 40 cm
Maximum length of logs in horizontal position| 25 cm
Range of wood consumption per hour recommended
(at 12% humidity)| 0.8 – 2.5 kg
Maximum limit for consumption of wood per hour
(to avoid overheating the system)| 3.3 kg/h
Recommendations
This appliance should be installed and checked by a qualified professional.
Ensure you have read the operation guidelines thoroughly prior to first use.
For any questions or concerns please contact The Fireplace Ltd on 09 6236990.
The installation process is outlined below:
- Determine position of firebox and flue carefully observing the clearances described within this section
- Install the external flue
- Install the internal flue and engage the firebox
- Ensure the floor has adequate protection
NOTE:
We strongly recommend that our products be installed and serviced by
professionals certified by the NZHHA.
CAUTION:
Using components or parts other than those provided by the manufacturer or
modifying the specification of components may result in inferior or unsafe
operation. If such action is necessary, consult the manufacturer in the first
instance.
Dimensions
PREPARATION OF THE AREA
Safety and clearance distances
he radiation from the glass door [diagram 1/a] and from the sides of the
stove [diagram 1/b] can be considerable.
Whatever the direction of the rotating stove, ensure safe distances from
combustible materials are maintained.
Minimum Clearance Internal
Clearance from non-combustible surfaces (eg. masonry)
100mm minimum clearance is required from fully non-combustible surfaces.
[diagram 2]
Clearance from combustible surfaces
(eg. timber, joist & concrete) in corner configuration. [Diagram 3]
Note: clearances may be reduced with the application of heat shielding to walls in accordance of AS/NZS 2918:2001.
Clearance from glass.
250mm minimum clearance is required from normal noncombustible glass.[Diagram
4]
IMPORTANT: Frames must also be considered. Timber window frames must be
treated as combustible surfaces. Aluminum frames can be treated as non-
combustible surfaces.
Clearance from combustible surfaces (eg. timber, joist & concrete) in parallel
configuration. [Diagram 5]
Safety and clearance distances (continued)
Protecting the floor
Any combustible floor beneath a fireplace must have a floor protector that
extends 300mm at the front.
If installed directly on combustible material, the floor protector must be
made of a minimum 9mm thick cement sheet or other non combustible finishes
including the Stuv Steel Plate.
If the combustible floor is installed on concrete, you can replace the
combustible material with noncombustible material laid directly onto the
concrete.
Floor Protector laid on Timber Floor.
Floor Protector laid on Joist.
Floor Protector laid on Concrete.
Top View.
Combustion air inlet
The stove requires air for combustion.
The ideal solution
The Stûv 30-compact one is designed to be directly connected to an outside
air inlet (independent of the air in the house). We recommend this set-up.
The connection can be made below the stove [diagrams 1/a et 2] or at the back
[diagram 1/b].
If the stove is not connected directly to an outside air inlet…
A sufficient air inlet (Ø 120 mm) should ideally be created close to the stove
[diagram 3].
This air inlet comes from a ventilated empty space, a ventilated room (cellar)
or from outside (mandatory regulation in some countries) [diagram 2].
The flue that brings in outside air… (whether it is connected to the stove or
not)
… will be protected on the outside by a grill [diagram 2/a-3/a] the free
passage section of which is at least equivalent to the section of the air
inlet. Please note that the infiltration of water and the effect of the wind
can damage the system.
… will ideally be fitted with a closure valve (for example, the Stûv valve –
see below) [photo 4] to prevent the room from becoming cold when the stove is
not in use.
… will be as short as possible to prevent pressure loss and to prevent making
the house cold.
If you use our standard flexible Ø 63 mm flue, we recommend a maximum length
of 2 m and no more than 4 elbows (see table below).
If you exceed these guidelines, you must compensate with a greater diameter
and/or a smoother duct.
Careful not to crush the flue.
Length of flue | max. permitted number of elbows |
---|---|
1 m | 4 elbows |
2 m | 4 elbows |
3 m | 2 elbows |
4 m | 0 elbow |
The closure damper
[diagram 2/b and photo 3] prevents the house from becoming cold when the stove
is not in use.
This system is optional if you choose a connection directly to the stove
[diagram 1]. However, it is still a good idea if the ducts are too long to
reach the stove or if it is being installed in an energy-efficient house.
It should ideally be located as close as possible to the outside wall. It can
be controlled from inside if it is not too far away from the stove (length of
the flexible of the valve control = 1.2 m).
If it is not possible to bring in outside air near the stove (most
unfavourable case)…
…ensure there is sufficient replenishment of air in the room when the stove is
in use.
CAUTION
Be careful with air extraction systems (kitchen hoods, air conditioning,
mechanically-controlled ventilation, other stoves) in operation in the same
space or in an adjacent room. They also use lots of air and can cause a
depression in the room and prevent the stove from operating correctly (risk of
draughtback). They can affect the operation of the stove even if it is
connected to an outside air inlet.
Smoke flue position, terminations and penetration
The appliance and flue-system shall be installed in accordance with AS/ NZS 2918:2001 and the appropriate requirements of the relevant building code or codes.
Warning: Mixing of appliance or fluesystem components from different
sources or modifying the dimensional specification of components may result in
hazardous conditions.
Where such action is considered, the manufacturer should be consulted in the
first instance.
Warning: The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation.
Warning: Products of combustion entering the room can cause serious health risks.
Warning: The following must be adhered to; AS/NZS 2918:2001:4.9.1
Basic information
For good draught, the stove must be suited to the flue (or vice versa).
An oversized flue is as detrimental to the smooth operation of the stove as an
undersized flue.
As the Stûv 30-compact one is a highly efficient stove, the smoke flue must
be of good quality. The flue must also be as straight and smooth as possible
and insulated to encourage drawing and to prevent condensation.
The ideal solution is a flue built inside the building and thermally
insulated.
An outside flue without any insulation must be avoided.
The stove must never be connected to a smoke flue serving several systems.
Take care to avoid heat loss !
If several flues are available : only use one of them. Block up the unused
flues at the top and bottom and, generally speaking, ensure that the top of
the recess where the stove is fitted is air-tight.
Standard outlet diameter The Stuv 30- compact stoves have an internal flue
dimension of 150mm.
Smoke flue position, terminations and penetration (continued)
Some flue configurations may require a different diameter than that provided
as standard. Should this be the case, please consult your retailer.
Flue position [diagram 1 & 2] The flue termination positions are the minimum
required as per NZS 2918:2001. It is possible that flue heights may need to be
increased as a result of conflicting air pressure envelopes that may develop
over some roof-line shapes and surrounding obstructions. Restriction into
clear air movement over any roof may also require different cowl designs,
particularly for high wind zones or varying local environment conditions.The
flue pipe shall extend not less than 4.6m above the top floor protector.
The minimum height of the flue system within 3m distance from the highest
point of the roof shall be 600mm above that point.
The minimum height of a flue system further than 3m from the highest point of
the roof shall be “a minimum” 1000mm above roof penetration.
No part of any building lies in or above a circular area described by a
horizontal radius of 3m about the flue system exit.
Terminate all flues a minimum of 600mm above the highest ridge-line of the
donor building.
In extreme wind areas it may be necessary to consult your local agent for
further technical assistance.
Flue penetration and terminations [Diagram 4 & 5]
The flue system’s penetration and termination must comply with AS/NZS2918:2001
Chimney casing must be ventilated as per diagram 5.
Note: All external air vents & ceiling penetrations must be bird & rodent
proofed with permanently fixed screens
Connection to the smoke flue
Allow play of 2 mm/m for expansion of the flue and to ensure smooth rotation of the stove.
Connection above [diagrams 1/a and 2/a]
If the flue is straight, it is simply placed on the stove ; the flue turns
with the stove.
If the flue has an elbow or isb deflected, it is fixed at wall or ceiling
level (rotation of stove only).
Calculation of the height of the duct
For the sinking of the duct at stove level, add 25 mm for a duct 2 mm in
thickness and 35 mm for a 0.4 mm duct.
Air-tightness
The various components which make up the connection between the stove and the
smoke flue and those which make up the flue itself have to be fitted so that
they are airtight for the condensation [diagram 2/a] rather than the smoke
[diagram 2/b].
Holding capacity of the structure
Ensure the floor is resistant enough to support the stove ; consult a
specialist if in doubt.
The stove must be bolted through the base and to the floor to comply with the
seismic restraint provisions of AS/NZS 2918:2001.
The stove’s surroundings
The heat radiated from the glass door and the walls may be significant.
Whichever direction the stove is facing, please adhere to the safety distances
from combustible materials [diagram 1] or ensure that the materials exposed to
radiated heat are resistant to high temperatures.
Prevent “heat traps” in the cladding, recess and hood If the stove is situated
in a bell-shaped area (ex : a former hearth), this space must be ventilated to
prevent “heat traps”.
Tools
INSTALLATION
On taking delivery of the equipment
Please note !
Check that the stove has not suffered any damage during delivery. The
guarantee only covers damage due to transportation if it is indicated on the
delivery slip.
Complaints
If you wish to make a complaint, always quote the serial number visible on the
stove in the lower door. [diagram 1]
Please note !
The paint is not oven baked and is therefore relatively fragile but will
harden after being heated a few times. Handle the system with care when
installing.
Accessories
– flue and upper connection
– ground plate
– kit for rear outside air intake
If any of these accessories have been ordered, they will be found around the
stove or its packaging. Check that you have received them.
Moving
While the stove is still packaged, you can use a pallet loader or a hand-lift
truck [photo 1]. Move it close to its final position.
If you are unable to transport the stove on its pallet to its final position,
please observe the following unpacking instructions.
Unpacking
> Remove the wooden structure using a claw hammer [photo 1].
> Remove the plastic packaging
[photo 2] and the plastic films at the top and bottom of the stove which hold
the mobile parts in place during transport.
Note ! The hand-lift truck protection [photo 3] supports the stove during handling to avoid putting pressure on the doors or the drum. It is later removed when the stove is moved into its final position.
Please note ! Never undo the two screws holding the support panel in place : it is factory adjusted and fixed [photo 4].
Removing the exterior parts of the stove
To make the stove lighter, easier to handle and to avoid damaging the mobile parts, we strongly recommend that you unpack the Stûv 30-compact one and remove the contents from the combustion chamber before starting the actual installation.
> Remove the 2 plates on the top of the stove :
on the Stûv 30-compact one simply remove the one at the back and then the one
at the front [photo 1]. > Remove the side panels using a size 10 socket
wrench [photos 2 and 3].
> Carefully cut the plastic film
holding the doors. Do not tear this film off ! One of the ends of this film is
stuck between the solid door and the body of the stove. Unlock and open the
door using the cold grip to release it [photo 4].
> Remove the hand-lift truck **protection :**
– open the door and undo the two nuts and bolts (M6x12 hexagonal heads)
holding the hand-lift truck protection in place [photo 5 and 6].
– pick up the 2 nuts and close the door.
> Remove the ash pan :
open the ash pan door [photo 7] and take it out by lifting it off its hinges
[photo 8].
> Remove the doors :
half open them gently [photo 9], lift them off their hinges and slide them to
the left [photo 10].
Unpacking the interior components of the stove
Checking the contents of the combustion chamber [photo 1]
You will find :
– spray paint for touching up [photo 1/a] – cold grip to handle the door and
the valve [photo 1/b] – 2 rotation stops and 2 M5x6 screws [photo 1/c] – a
sealing plate and 2 M5x8 screws [photo 1/d] – installation instructions
– instructions for use
Note !
When you handle symmetrical parts while dismantling, remember to take note of
which are the left parts and which are the right ones ! It will make re-
assembly easier.
Removal of the following parts
> the smoke deflector :
the smoke deflector has been locked down to prevent damage during transport.
Remove the two blocking screws from the inside [photo 2].
Tilt and gently slide the smoke deflector towards the back [photos 3 and 4].
Turn it clockwise to release the deflector and its control [photo 5]. Let the
deflector drop down [photo 6].
> the 2 vermiculite deflectors : lift up the stainless steel support [photo 7] and slide it forwards [photo 8] then let the part drop to remove it [photo 9].
> the lateral holders : before removing the lateral holders, first remove
the lateral keys : lift them up and bring the bottom of the parts forward
[photo 10].
To remove the lateral holders ; slide them to the back, [photo 11], tilt them
and take them out [photo 12].
> the back holder : remove the pressure screw keeping the deflector cradle in place [photo 13] and pull the back holder forwards [photo 14]. Tilt it towards the stove opening.
> the ash grille [photo 15].
> the lower protection strut [photo 16].
the stove hearth holder : lift it up and tilt it by 90° [photos 17 and 18].
the smoke deflector cradle [photos 19 to 21].
Final positioning of the stove
Please note ! Do not forget to put the hand-lift truck protection back on
before moving the stove !
The stove can now be moved to its final position : tilt the stove onto its
front.
Note : remember to put a soft protective cloth between the drum ring and
the hand-lift truck.
Connection with outside air
If you are not connecting your stove to the outside air, go to the next section.
If the air connection comes from the ground :
> Fix the filling plate (with an 8 mm flat spanner and 2 M5x8 hexagonal
head screws) [photos 1 to 4] : > Position the stove over the outside air
inlet.
> Check that the joint is fully airtight in relation to the floor.
If the air connection comes from the wall :
> Find the “rear outside air inlet” kit[photo 5].
> Make sure the duct is the desired **length** bearing in mind the
maximum length of the standard Stûv inlet duct is 50 cm. Cut it if necessary.
Connect the flue to the back of the stove (using 2 M5x6 hexagonal head screws and a size 8 spanner) [photo 6].
> Fix the 2 masking supports [photo 7a] – Position the supports so that
the additional piece is at the front of the stove [photo 9].
– Fix the 2 supports (using the 4 M5x6 hexagonal head screws and a size 8
spanner) [photo 10].
> Clip on the 2 masking pieces [photo 7b] to their supports and check
that they are firmly in place [photos 11 to 12].
> Prepare the 2 panels by removing the lower pre-cut part (using a metal
saw) [photo 13]. Smooth the panel edges with a half-moon file.
> Put the stove in position [photo 14].
Levelling and fixing the stove
Before you start, make sure that the floor covering is flat and clean.
If the floor covering is not level, you will have to take steps to ensure that
the lower joint is perfectly airtight.
> Remove the hand-lift truck protection for the final time [photo 1].
> Level the stove : adjust 3 of the 6 feet (1 of each 2) by turning them
clockwise (using a size 13 spanner) [photo 2]. Leave the other 3 feet for the
moment. Please note ! Ensure that the joint is properly supported on the
ground to ensure air-tightness for outside air intake.
> Adjust the last three feet.
IMPORTANT ! The holes in the lower ring are used to bolt the stove to the
floor to comply with seismic restraint requirements [photo 3].
Connection to smoke flue
Remarks
If you are going to use a connecting flue that is all one piece, allow play of
2 mm/m in length to allow for expansion.
The smoke outlet can accept ducts of 0.4 to 2.0 mm in thickness.
It is preferable to use the screws supplied by Stûv. If not, make sure that
you do not use screws that are too long and will block the rotation system.
Connection going upwards
Fit the flue onto the top of the stove and fix it in place using the 3
selftightening screws in the 3 holes provided [photo 1].
Directing the stove
A turning plate means the stove can face in the direction you want the heat to be diffused !
Various possible configurations
You can limit the rotation of the stove to a certain angle using the rotation
stops. The choice of rotation angle will depend on your preference, the
configuration of the site and the proximity of combustible materials.
The stove’s connection (smoke outlet and outside air inlet) will also
determine the choice of configuration.
Smoke connection going upwards [diagram 1]
> 360° Rotation : The mechanism allows a complete revolution in both directions [diagram 2].
> 90° Rotation when the stove is placed in a corner [diagram 3].
> 180° Rotation when the stove is placed along a wall [diagram 4].
270° Rotation when the stove is placed in front of a corner or a pillar [diagram 5].
Smoke connection going upwards with outside air inlet at the back [diagram 6]
> 90° Rotation : only configuration possible in this case [diagram 7 and photo 8].
Rotation stop
The rotation stop enables you to0 choose a maximum angle of rotation to which
the stove can turn.
> First of all, choose your configuration for the stove (see previous
pages). This will define your maximum angle of rotation.
> Take out the 3 stepped screws with a flat screwdriver (2 screws at the
front, 1 screw at the back) [photos 1 and 2].
Please note ! Once the 3 stepped screws have been removed, do not under
any circumstances move or tilt the stove. This risks damaging the rotation
axle of the stove.
> Limit the angle of rotation to 90°, 180° or 270° by fixing the stops
[photo 3] (with the M5x6 hexagonal screws) in position :
for 90° [photo 4] > for 180° [photo 5] > for 270° [photo 6]
Please note ! Ensure that you fix the stop the right way around (look closely at the photos).
Final assembly
If you have dismantled your stove, re-assemble the following parts :
– the smoke deflector cradle
– the stove hearth holder
– the lower protection strut
– the ash grille
– the back holder
– the lateral holders
– the lateral keys
– the 2 vermiculite deflectors
– the smoke deflector
Follow the reverse of the dismantling steps ! (see pages 12 to 16)
Please note ! Do not mix up the left and right symmetrical parts.
Put the last parts back in place :
the ash pan support, insert it right to the back of the stove. Press down at the front of the ash pan support so that it slots properly into place [photo 1 and 2].
the ash pan [photo 3],
the door
the panels : position the lower part by placing the holes over the positioning cones [photo 5].
Then fix the upper part of the panels by screwing them into place (using 4 M5x8 hexagonal head screws) [photo 6].
> the 2 upper plates : clip the front part of the plate into place [photo
7].
Then place the rear part of the plate in position [photo 8].
> the ash pan door [photo 9].
Please note ! Check that the blocking screws in the combustion chamber for
transportation purposes have been removed [photo 10].
When installation of the stove is complete…
… test that the stove is working properly.
Before testing, make sure that no items from the installation have been left
in the combustion chamber or the bends and turns (spray paint, tube of grease,
tools…) When the fire is lit for the first time, it may give off some smoke
and odours :
ventilate the room well.
Consult the instructions for use.
Once the stove is installed, give the instructions for use to the user.
Complete the guarantee certificate (at the back of the instructions for use)
with him/her and recommend that they send it to the manufacturer or the
importer.
CONTACTS
Stûv stoves are designed and manufactured in Belgium by :
Stûv sa
rue Jules Borbouse 4
B-5170 Bois-de-Villers (Belgium)
info@stuv.com
www.stuv.com
Importer for New Zealand
The Fireplace Ltd
12 Tawari Street
Mt Eden, Auckland, New Zealand
www.thefireplace.co.nz
ACCEPTANCE OF WORKS
PLEASE COMPLETE IN BLOCK CAPITALS.
THE PURCHASER
SURNAME ……………….
FIRST NAME ……………….
ADDRESS WHERE WORKS WERE CARRIED OUT……………….
POST CODE……………….
TOWN/PLACE……………….
COUNTRY ……………….
INSTALLATION ENGINEER
COMPANY……………….
YOUR STÛV STOVE 30-COMPACT ONE
SERIAL N° ……………….
DATE OF INSTALLATION ……………….
FLUE CHARACTERISTICS
HEIGHT OF FLUE IN M ……………….
DIAMETER OF FLUE IN MM ……………….
TYPE OF FLUE……………….
CHECK OF SYSTEM’S SETTINGS
CHECK ON THE VACUITY OF THE FLUE ……………….
VALIDATION OF DRAUGHT ……………….
VERIFICATION OF AIR INLET SETTING
(OPEN/CLOSED) ……………….
CHECK OF THE HUMIDITY OF THE WOOD …………………HUMIDITY% NO WOOD
COMMENTS ……………….
SAFETY GUIDELINES
The use of this system has to comply with the installer’s recommendations and
the manufacturer’s instructions which are set out in the directions for use
issued to the customer with the invoice and this confirmation of acceptance.
The efficiency and longevity of the system depend directly on the quality of
wood used: it is essential that wood with humidity of less than 18% or
reconstituted wood briquettes are used. Green wood with drying-out time of
less than 24 months cannot be used (more information in the “fuels” section on
pages 8 and 9 of the directions for use).
THE INSTALLATION ENGINEER (name written out in full and signature)
………………………………
THE CUSTOMER (name written out in full and signature) ………………………………………………….
Directions for use of the system issued to customer / Information
sheet on lighting the stove issued to the customer
installation instructions Stûv 30-compact one [nz] 02/20 – SN 162181 > …
Stûv reserves the right to make changes without prior notice.
These instructions have been produced with the greatest of care. However, we
do not accept responsibility for any errors that may have been made.
Editor: Gérard Pitance – rue Jules Borbouse 4 – 5170 Bois-de-Villers – Belgium
Stûv reserves the right to make changes without prior notice.
These instructions have been produced with the greatest of care. However, we
do not
accept responsibility for any errors that may have been made.
Editor: Gérard Pitance – rue Jules Borbouse 4 – 5170 Bois-de-Villers – Belgium
[nl] [de] [it] [es] [pt] [cz] [en] [fr] > This document is available
in several languages :
Contact your distributor or visit www.stuv.com
93109157 – notice d’installation – Stûv 30 Compact one NZ
Authorization Number CRC 201302
February 2020
93109157
Documents / Resources
| Stuv
30 Compact One Modern Wood
Stoves
[pdf] Instruction Manual
30 Compact One Modern Wood Stoves, 30 Compact, One Modern Wood Stoves, Wood
Stoves, Stoves
---|---
References
- Stûv - Fitted stoves, Wood-burning stoves, Ready-to-fit fireplaces
- NZ's Leading Fireplace Store - Stûv, Stovax & More | The Fireplace – The Fireplace NZ
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>