medisana MBH Spa Bath Mat Instruction Manual
- June 4, 2024
- medisana
Table of Contents
- medisana MBH Spa Bath Mat
- Device and controls
- Safety Instructions
- Operating the device
- Battery Safety Information
- Maintenance and cleaning
- Proper use
- Cleaning and maintenance
- Technical specifications
- Warranty and repair terms
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
medisana MBH Spa Bath Mat
Device and controls
- Remote control (front)
- Remote control (rear) with suction cup
- Battery Compartment with 3 V, CR2032 lithium battery
- Pump unit 220-240 V AC, 50 Hz, 450 W
- Infrared sensor for remote control
- LED indicator light flashes green, red and orange
- On/off button switches the unit on and off
- Mains cable with plug (about 2.2 m long)
- Hose end with guide / with insert for scent pad holder (connection to power unit)
- Scent pad holder (to be inserted into hose)
- Scent pad holder closed (with pad inserted)
- Scent pad holder (open with pad)
- Aromatherapy oil (not supplied)
- Soft mat suitable for all types of bath, with suction cups on underside
- Hose end without guide (connection to soft mat)
- Air hose (about 2.4 m long)
- Intensity control button
Explanation of symbols
- Non-observance of these instructions can result in serious injury or damage to the device.
- WARNING These warning notes must be observed to prevent any injury to the user.
- CAUTION These notes must be observed to prevent any damage to the device.
- NOTE These notes give you useful additional information on the installation or operation.
- Protection class for water and dust
- Only use the spa bath matindoors!
- Do not use the power unit above any type of water-filled container!
- Protection category II
- Lot number
- Manufacturer
Safety Instructions
Read the instruction manual carefully before using this Bdevice, especially the safety instructions, and keep the instruction manual for future use. Should you give this device to another person, it is vital that you also pass on these instructions for use.
Power supply
- Before connecting the spa bath mat to the power supply, please check that it is switched off and that the mains voltage of your power supply corresponds to the voltage listed on the rating plate.
- Always use a socket that is accessible when connecting the appliance.
- The appliance should be supplied through a residual current device (RCD) with a rated tripping current not exceeding 30 mA.
- Make sure that the main appliance is not able to fall into the bath and that it cannot be reached from the bath.
- Keep mains cable and power unit away from heat, hot surfaces, humidity and liquids. Never touch the mains plug when your hands are wet or when you are standing in water.
- If the connection cable on this appliance is damaged, it must be replaced by the manufacturer, its customer service or by similarly qualified personnel to avoid any risk of danger.
- The parts of the device conducting electrical voltage must be securely assembled to ensure they are unable to fall in the bath and kept out of reach of anyone in the bath.
- If the device falls into water, do not try to pick it up. Instead pull the plug out immediately.
- When you have finished using the spa bath mat, always pull the plug out of the socket. Never disconnect the device from the mains by pulling on the power supply cable.
For special people
- Do not leave the equipment unattended whilst it is connected to the mains.
- Do not use this equipment to support medical treatment or as a replacement for this. Chronic diseases and symptoms may worsen.
- Do not use the device if you have sensitive skin or suffer from heart/circulation complications, phlebitis or high blood pressure.
- Pregnant women should assess their personal levels of tolerance.
- In case of unexplained pain, only use the equipment after consulting a doctor.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance
Operating the device
-
The unit is only to be used for the specific purpose described in this instruction manual. Any misuse will void the warranty.
-
Check pump unit, soft mat and mains cable carefully for damage before each use. Do not attempt to use a defective unit. In order
to prevent hazards, always send the unit in to the service centre. -
Do not use the appliance if it is damaged, if its power cord or plug is damaged, if it is not in perfect working order, or if it has been dropped or fallen into water.
-
Always check first that the plug has been pulled out of the socket, before you insert or remove components.
-
Do not use any auxiliary parts that have not been recommended by the maker.
-
Do not insert any objects in any of the openings on the appliance or the air hose.
-
Only use the spa bath mat indoors!
-
Do not use the pump unit above any type of waterfilled container!
Battery Safety Information
- Do not disassemble batteries!
- Remove discharged batteries from the device immediately!
- Increased risk of leakage, avoid contact with skin, eyes and mucous membranes! If battery acid comes in contact with any of these parts, rinse the affected area with copious amounts of fresh waterband seek medical attention immediately!
- If a battery has been swallowed seek medical attention immediately!
- Insert the batteries correctly, observing the polarity!
- Remove the batteries from the device if it is not going to be used for an extended period!
- Keep batteries out of children‘s reach!
- Do not attempt to recharge these batteries! There is a danger of explosion!
- Do not short circuit! There is a danger of explosion!
- Do not throw into a fire! There is a danger of explosion!
- Do not throw used batteries into the household refuse; put them in a hazardous waste container or take them to a battery collection point, at the shop where they were purchased!
- The air spa unit must be positioned so that it is out of reach of anyone in the bath.
- Using the unit for more than 30 minutes at a time is not recommended. The unit may overheat if it is used for too long continuously.
- Never place and/or use the pump unit immediately next to electric heaters or other heat sources and do not use it near them.
- Ensure that the equipment, and in particular the soft mat, does not come into contact with pointed or sharp objects and do not push pins into it.
- Do not use the equipment when the openings are blocked.
- Do not stand on the pump unit.
- Do not use the unit when you are tired. Do not fall asleep whilst using it.
Maintenance and cleaning
- You may only clean the spa bath mat. Do not attempt to repair the unit yourself in the event of any defects. Not only does this render the warranty null and void but you can also run the risk of serious hazards (fire, electric shock, injury). Only have repairs carried out by authorised service points.
- Cleaning and user maintenance shall not be made by children without supervision.
- Before cleaning the unit, switch it off and unplug it from the mains. Never immerse the pump unit in water or other liquids.
- Note the section on “Cleaning and maintenance”.
- Never carry, pull or rotate the device by the mains cable and never pinch the cable between other objects.
- Always let the pump unit cool down and let the soft mat and its accessories dry completely before storing them. Store the spa bath mat in a clean and dry place, preferably in the original packaging, until you use it next.
Proper use
The air spa bath is designed to have a relaxing effect on the user from the generation of air bubbles. This spa bath mat is intended only for private use and not for commercial purposes or for medical applications! If you have any medical concerns, please discuss using the spa bath mat with your doctor before using it
WARNING
Please ensure that the polythene packing is kept away from the reach of
children! Risk of suffocation
Items supplied and packaging
Please check first of all that the device is complete and is not damaged in
any way. In case of doubt, do not use the appliance and contact your dealer or
your service centre. The following parts are included:
- 1 power unit with mains cable
- 1 air hose
- 1 soft mat
- 1 remote control with CR2032 battery
- 3 scent pad holder with pads
- 1 instruction manual
Operating
Preparation
- Make sure there is a pleasant room temperature in the bathroom.
- Position the unit 4 at a distance of at least 60 cm from the bathtub, so that it is out of reach. Ensure that the air inlet on the underside is not covered. The floor must be dry.
- Place the soft mat r into the bath and press it down. The suction cups on the underside of the soft mat stick better if you first wet the soft mat with the shower head. The air connection on the mat is at the foot end.
- The soft mat r must be firmly attached to the bath and must not slide around.
- Connect the smooth hose end t to the soft mat r.
- Run the bath water. Make sure that the water has a pleasant temperature, but is not too hot.
- Do not use any bath foam.
CAUTION
After use, the best way of taking the soft mat out of the bath is by carefully
sliding a fingernail under the suction cups to release the vacuum. Pull the
soft mat sideways off the bath without tearing it.
Aromatherapy
-
You can use the appliance with or without the scent pad holder. If you want to use the spa bath mat with aromatherapy, put one drop of aromatherapy oil e on a pad, place this in a scent pad holder w
and close this. Do not oversaturate the pad. Too much aroma essence could damage the surface of
the scent pad holder. -
Push the closed scent pad holder q into the insert provided for this purpose in the open hose end 0.
-
Place the end of the hose with the scent pad holder into the connection on the pump unit z.
-
Plug the mains cable 8 into the socket
Operate the unit
The air bubble bath can be adjusted using the remote control 1. Switch on the
unit by pressing the button (on the unit or on the remote control). You can
now set one of the three options for the intensity of the bubble bath using
the intensity selection button u on the remote control.
- After switching on, the unit immediately operates at low power. LED 6 on the handle flashes green.
- Press the intensity selection button u once to switch to the higher power level. LED 6 on the handle now flashes red.
- Press the intensity selection button u once more to enter the interval massage programme. The appliance now alternates between the two power levels. The LED 6 on the handle flashes orange.
- If you press the intensity selection button u a third time, the appliance switches back to the low power level.
- After use, switch off the unit by pressing the button 7 (on the unit or on the remote control). The appliance switches off automatically after 20 minutes of use. Continuous use for more than 30 minutes is not recommended (see safety instructions).
- Do not immerse the remote control in water.
- There is an adhesive suction pad on the back of the remote control. If you moisten it a little, you can attach it to the bathroom wall or the edge of the bathtub at a comfortable distance.
- The remote control 1 only works when it is pointed at the infrared sensor 5 on the handle of the unit.
- Before switching the unit on again, take a break of at least 10 minutes.
Changing the battery
The remote control 2 uses one 3V CR2032 lithium battery. It is located in the
battery compartment 3 on the rear of the unit. To change the battery, open the
battery compartment cover with a suitable coin. Take out the old battery and
replace it with a new 3V CR2032 lithium battery. Ensure that it is inserted
correctly – with the plus pole to the top. Close the battery compartment 3
using a coin
Cleaning and maintenance
Please pull the plug out of the socket before cleaning the unit!
- The pump unit and the remote control do not require servicing. They only need to be cleaned with a soft damp cloth occasionally.
- Please rinse the soft mat with a shower head or a sponge. If required, use a mild household cleaner or soapy water.
- Never use aggressive cleaning agents or strong brushes.
- It is best to remove any remaining water by turning over the mat and lying it flat in the empty bath, then press it lightly so that the remaining water can be squeezed out by the air.
- Disinfect the mat at regular intervals to keep it free of bacteria. It is advisable to disinfect it every week if it is used on a daily basis, especially if the air spa bath is used by several people. Use a standard household disinfectant and observe the manufacturer’s instructions.
- Straighten the cable if it has become twisted.
- It is best to store the unit in the original packaging in a dry and clean place.
Disposal
This product must not be disposed of together with domestic waste. All users
are obliged to hand in all electrical or electronic devices, regardless of
whether or not they contain toxic substances, at a municipal or commercial
collection point so that they can be disposed of in an environmentally
acceptable manner. Remove the batteries before disposing of the device/unit.
Do not dispose of old batteries with your household waste, but at a battery
collection station at a recycling site or in a shop. Consult your municipal
authority or your dealer for information about disposal.
Technical specifications
- Name and model: medisana bath spa MBH
- Power supply: 220-240 V~ 50 Hz
- Remote control: 3V CR2032 lithium battery
- Motor rating: approx. 450 W
- Operating time: 30 min max
- Recovery period: at least 10 min
- Autom. switch off: after approx. 20 min
- Power cable length: approx. 2.2 m
- Item number: 88377 / 88379
- EAN number 40 15588 88377 4 / 40 15588 88379 8
Spare parts:
Article No. / Description
- 88383 Soft mat (approx. 36 x 120 cm)
- 88376 Remote control with battery
- 30666 Air hose (approx 2.4 m)
- 30669 Scent pad holder with 3 pads
In accordance with our policy of continual product improvement, we reserve the right to make technical and optical changes without notice. The current version of this instruction manual can be found under www.medisana.com
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty. If you have to return the unit, please enclose a copy of your receipt and state what the defect is. The following warranty terms apply:
- The warranty period for medisana products is three years from date of purchase. In case of a war-ranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
- Defects in material or workmanship will be removed free of charge within the warranty period.
- Repairs under warranty do not extend the warranty period either for the unit or for the replacement parts.
- The following is excluded under the warranty:
- All damage which has arisen due to improper treatment, e.g. nonobservance of the user instructions.
- All damage which is due to repairs or tampering by the customer or unauthorised third parties.
- Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre.
- Accessories which are subject to normal wear and tear.
- Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim.
medisana GmbH, Carl-Schurz-Str. 2, 41460 NEUSS, GERMANY
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>