COMPONENTS

Product Parts

  1. Control panel
  2. Air outlet with adjustable louvers
  3. Handle
  4. Display
  5. Air inlet with air filter
  6. Castor wheel
  7. Outlet
  8. Air outlet

INSTALLATION

Warning: after removing the unit from the packaging, leave it upright for 24 hours before using it. Do not install the device in rooms with an area smaller than 9m2. The device should be placed at least 50cm from the wall or other obstacles on a flat and horizontal surface. When the appliance is not used for a longer period of time, it is recommended to disconnect the drain hose and the window kit.

CONTENTS

  1. Unpack the box and remove the unit and accessories.

  2. After unpacking, check the device for any damage or scratches.

  3. Exhaust hose

  4. Hose connector

  5. Window kit adapter

  6. Remote control

  7. Window kit + exhaust pipe
    Window kit + exhaust pipe

CONNECTING

  1. Connect the hose connector to one end of the exhaust hose.
    Connection

  2. Connect the window kit adapter to the other end of the exhaust hose.
    Connection

  3. Extend the adjustable window kit to the length of the window. Connect the exhaust hose to the window kit.
    window length

  4. Close the window to secure the window kit in place. The window should hold the kit firmly in place. If necessary, secure the window kit with duct tape. It is recommended to seal the gap between the adapter and the sides of the window for maximum efficiency.
    Close The window

  5. Connect the hose connector to the exhaust air outlet of the unit.
    Connection

  6.  Avoid bends in the hose by adjusting the length of the flexible exhaust hose.
    Adjusting The length

  7. Adjust the louver at the air outlet and plug in the unit.

OPERATION

REMOTE CONTROL
Adjusting
CONTROL PANEL
Control Panel

1 POWER Turn the unit ON or OFF
2 MODE Change mode: cool, ventilate or dehumidify
3 SPEED Change ventilation speed: HIGH or LOW.
4 FAN SPEED indicator Indicates the ventilation speed
5 DOWN Lower the temperature (min. 16C°) or adjust the timer
6 MODE indicator Indicates the current mode: cool, ventilate or dehumidify
7 UP Increase the temperature (max. 32C°) or adjust the timer
8 Digital display Displays the timer and temperature settings.
9 TIMER Set a timer to automatically turn the unit on or off.
10 TIMER/POWER indicator Shows whether the unit and the timer are ON or OFF

TURNING THE DEVICE ON AND OFF:

Press POWER to turn on the device. Press the MODE button to select the desired operating mode. Press POWER again to turn the device off.

MODES
The unit has four modes: cooling, dehumidifier, ventilation, sleep.

COOLING

  1. Select the cool mode to lower the temperature in the room.
  2. Press the MODE button repeatedly until the COOL mode LED lights up.
  3. Press the UP/DOWN button to set the temperature displayed on the screen. The temperature can be set between 16℃ and 32℃.
  4. Press the SPEED button repeatedly until the desired fan speed indicator lights up.
  5. To adjust the direction of airflow horizontally, bring the louver to the desired position by hand.

Note: The air conditioner stops operating when the room temperature is lower than the selected temperature.

VENTILATION

Press the MODE button repeatedly until the FAN indicator lights up. In ventilation mode, the room air is circulated but not cooled.

Press the SPEED button repeatedly until the desired ventilation speed is reached.

DEHUMIDIFYING

Press the MODE button until the DRY mode LED lights up.

Caution: In this mode, the fan will automatically switch to low speed. The user must have the hose connected to the drain opening on the bottom of the unit.

SLEEP MODE:
Caution:
The sleep mode can only be activated in COOL (cooling) mode.

When the unit is in COOL mode:
After 1 hour, the set temperature is increased by 1℃, after another hour, the set temperature is increased by 1℃ again

TIMER
The timer can be operated in two ways.

To turn off the unit:
Press the timer button to turn on the timer function. Press UP/DOWN repeatedly to set the duration time.

To turn the device on:
Press the timer button to turn on the timer function. Press UP/DOWN repeatedly to set the duration time.

To cancel the timer:
Press UP/DOWN repeatedly until the LED reads ’00’. Note: The timer can also be turned off by pressing POWER.

AUTOMATIC DEFROSTING
At low room temperatures, frost may accumulate on the evaporator. The unit will then automatically begin defrosting ‘

(POWER LED flashes.)
In case of power failure, to protect the compressor there is a 3 minute delay until the unit restarts.’

SELF EVAPORATING SYSTEM AND WATER TANK:
The self-evaporating system uses the collected water to cool the condenser coils for better performance. The condensation water evaporates at the condenser and is discharged through the exhaust hose. The drain tank only needs to be emptied manually in case of high humidity.

Emptying the water tank:

  1. Make sure the unit is turned off and unplugged.

  2. Remove the cap from the water drain opening and store it in a safe place.
    Water Tank

  3. Connect the drain hose to the drain opening, making sure it is not kinked or blocked.

  4. Place the outlet of the hose over a drain or bucket and make sure water can flow freely out the unit.
    Water Tank

CAUTION: Do not submerge the end of the hose in water, or an “air lock” may form in the hose and the water will no longer flow to the drain or bucket.

CAUTION: Because the negative pressure of the condensate drain pan is high, the drain hose should be tilted downward toward the floor. The angle of inclination should be more than 20 degrees.

CAUTION: In case of high humidity or frequent use of the DRY function, it is necessary to empty the water tank continuously!

CLEANING AND MAINTENANCE

HOUSING
The housing can be cleaned with a damp cloth.

FILTER
Check the filter every 2 weeks. Clean the filter with a vacuum cleaner. If necessary, rinse the filter with water
Cleaning Instruction
CAUTION: Do not reinstall the filter until it is completely dry!

STORAGE

The evaporator in the unit must be dry before storing it for an extended period of time. Unplug the unit and place it in a dry open area for several days to allow it to dry.

Another way to dry the unit is to turn the unit on, set it to a low wind ventilation setting, and keep that setting on until the exhaust hose is completely dry. This will prevent mold from forming on the inside of the appliance.

The appliance should be kept in an upright position when stored. Store it in a ventilated, dry and safe place indoors.

WARRANTY

The warranty period is 2 years, starting from the date of purchase. During the warranty period, Eltra NV will remedy all defects caused by material or production errors. Eltra NV is not obliged to replace devices that have become defective as a result of damage, improper use, modifications or alterations that were made after the date of purchase. Wear of the blade is not included in the warranty.

Return the defective unit, along with the original proof of purchase, to the store where the unit was purchased. Always include a note describing the problem.

DAMAGE

Eltra NV can under no circumstances be held liable for damage of any kind if the device has not been installed correctly according to the prescribed installation instructions, nor for damage resulting from unforeseen circumstances such as natural disasters, lightning strikes, ….. All resulting costs are therefore the sole responsibility of the purchaser and are not covered by the warranty.

ERP DATA

Mod el : 1545144091
Description unit

Data
Output power for oxiing    P rated| kW| 2.611
Output power for heating  P rated| kW| –
Power input for cooing   P EER| kW| 1.003
Power input for heating     P COP| kW| –
Thermostat-off mode power consumption P TO| W| –
Standby mode power consumption  P SB| W| 0.43
OFF mode power consumption P OFF| W| –
Crankcase heater mode power consumption K uK| W|
Calculated data
Energy efficiency ratio  EER rated| | 2.633
Coefficient of performance   COP rated| | 24?_
Electricity consumption of single duct appliance Q SA| kWh. h| 1.003
Electricity consumption of double ducts appliance DDD| klahal| –
Sound power level (indoor) L WA| dB(A)|
Global warming potential  GWP| kgCO.
ec|

EU DECLARATION OF CONFORMITY

Declaration number: 545144091 _DoC
Name and address of manufacturer / EU-AR: Eltra nv/saPachtgoedstraat 2 Eltra nv/sa Pachtgoedstraat 2 9140 Temse Belgium

THIS DECLARATION OF CONFORMITY IS ISSUED UNDER THE SOLE RESPONSIBILITY OF:

Name and address of manufacturer: Eltra nv/sa Pachtgoedstraat 2 9140 Temse Belgium

Product identification: AIRCO MOBIEL 9000BTU + AFST Ref.
Eltra Art. :
545144091
Eltra EAN :
5412748764420
Ref. manufacturer :
OL-BKY26-A010L

THE PRODUCTS MENTIONED IN THIS DECLARATION ARE IN CONFORMITY WITH:

EU Community Legislation: The Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU and amendement (EU)2015/863

Harmonized standards:
LVD
: EN 60598-2-4:2018; EN 60598-1:2015, AMD1:2018; EN 62493:2015
RoHS : IEC62321-2:2013, IEC62321-3-1 :2013, IEC152321-4:2017, IEC62321-
5:2013, IEC62321-7-1 :2015, IEC62321-7-2:2017, IEC62321-6:2015, IEC62321-8:2028

SIGNED FOR AND ON BEHALF OF:

Place and date of issue: Temse, 02/12/2021

Signature:
Signature

Name, function: Dirk Baum, CEO
Company name: Eltra nv/sa
CE MarkProfile
Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Profile User Manuals

Related Manuals