Product Information

  • The Steel Raceway is a two-piece steel surface raceway that is available factory-prewired. It is part of the 3000 Series Raceway, which is designed for wiring applications in frequently changing environments such as labs, hospitals, and other industrial applications. The raceway is shown in the manual utilizing data inserts and electrical devices.
  • The 3000 Series Single Channel Raceway has an overlapping cover, allowing for easy installation and future changes. It has various features and benefits including entrance knockouts spaced at regular intervals along the length of the base, allowing for convenient power wiring, communication, or A/V cables to be brought in. The raceway can be easily mounted on walls, modular furniture, under raised floors, or over ceilings, providing flexibility to bring wiring to points of use.
  • The raceway has a removable cover, providing access to the wiring. It can accommodate a variety of receptacles, three-pole circuit breaker housings, and other protective devices, offering flexibility for sophisticated wiring systems. It also has a complete line of fittings, providing a complete wiring solution and allowing for interconnection between raceway systems.
  • The raceway is available prewired, manufactured to specified job site lengths, and comes electrically prewired and ready to install. It can be packaged by room, area, floor, or building and shipped per job site requirements. It also offers electrical device identification for prewired raceway, eliminating guesswork or time-consuming circuit tracing and speeding up additions and renovations.
  • Additionally, the raceway is compatible with A/V devices by using 5507 Series Faceplates. It has a gray baked enamel and ivory ScuffCoatTM finish, making it durable with a scratch-resistant surface. The raceway also has base and cover cutters that are lightweight and portable, offering labor savings for any size job and maintaining a factory clean and square cut.
  • Furthermore, the raceway provides datacom connectivity options, accepting industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use. It is UL Listed factory multioutlet assemblies and meets UL5 and ADA compliance requirements. The raceway is also UL-listed and CSA Certified.

Product Usage Instructions

To install the Steel Raceway, follow these steps:

  1. Choose the appropriate length of the raceway for your wiring application.
  2. Mount the raceway on walls, modular furniture, under raised floors, or over ceilings using suitable mounting hardware.
  3. If needed, use the base and cover cutters to make clean and square cuts on the raceway.
  4. If using a prewired raceway, identify the electrical devices according to the labeling options provided on page six of the manual.
  5. Bring in power wiring, communication cables, or A/V cables through the entrance knockouts spaced at regular intervals along the length of the base.
  6. If required, install receptacles, circuit breaker housings, or other protective devices into the raceway to suit your wiring system.
  7. If using A/V devices, utilize the 5507 Series Faceplates for compatibility.
  8. Ensure proper connections and secure wiring within the raceway.
  9. Replace the removable cover to provide access to the wiring.

Note : Always refer to the specific instructions and guidelines provided by the manufacturer for your specific wiring application to ensure proper installation and usage of the Steel Raceway.

Available Factory Prewired

3000® Series Raceway provides wiring capacities for small to medium-sized installations. Power, communication, or A/V devices can be wired into the raceway for a flush appearance satisfying both aesthetic and functional requirements. 3000 Series Raceway is ideally suited for wiring applications in frequently changing environments such as labs, hospitals and other industrial applications.legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig-
\(1\)

FEATURES & BENEFITS

  • Entrance knockouts spaced at regular intervals along the length of base. Allows power wiring, communication, or A/V cables to be brought in at a convenient point.
  • Mounts easily on walls, modular furniture, under raised floors, or over ceiling. Speeds installation; provides flexibility to bring wiring to points of use.
  • Removable cover. Provides access to wiring.
  • Accommodates a variety of receptacles, three-pole circuit breaker housings, and other protective devices. Provides flexibility for sophisticated wiring systems.
  • Complete line of fittings. Provides a complete wiring solution and allows for interconnection between raceway systems.
  • Available prewired. Manufactured to specified job site lengths, the raceway comes electrically prewired, ready to install. Jobs can be packaged by room, area, floor, or building and shipped per your job site requirements.
  • Compatible with A/V devices by using 5507 Series Faceplates.
  • Gray baked enamel and ivory ScuffCoat™ finish. The durable ivory ScuffCoat finish makes a scratch-resistant surface.
  • Base and cover cutters. Manually operated cutters are lightweight and portable. Cutters offer labor savings for any size job and maintain a factory clean and square cut.
  • Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
  • UL Listed factory multioutlet assemblies. Listed by Underwriters Laboratories Inc. Multioutlet assemblies file number E15191 Guide (PVGT)/ Fittings file number E41751 Guide (RJPR).
  • UL5 and ADA compliant. The raceway and fittings meet UL5 specifications and can be installed in conformance with ADA requirements.
  • UL Listed and CSA Certified raceway. Listed by Underwriters Laboratories Inc. Raceway file number E4376 Guide (RJBT)/ Fittings file number E41751 Guide (RJPR) CSA Certified LR350.Electrical device identification for prewired raceway. See page six for labeling options. Eliminates guesswork or time-consuming circuit tracing and speeds additions and renovations.

Download this product’s PEP ecopasport® environmental product declaration at www.legrand.us/resources-and-downloads. This declaration conforms with ISO 14025 and 14040 and is in alignment with EN 15804.

System Layout

legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig-
\(2\)

NOTE : Illustration is for showing product applications only.

Raceway Ordering Information

legrand-G3046BE-3000&-Series-Duplex-
Receptacle-Cover-fig- \(3\) legrand-
G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig- \(4\) legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig-
\(5\) legrand-G3046BE-3000&-Series-
Duplex-Receptacle-Cover-fig- \(6\) legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig-
\(7\) legrand-G3046BE-3000&-Series-
Duplex-Receptacle-Cover-fig- \(8\) legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig-
\(9\)

Add C prefix to denote Canadian version – CSA certified.

Raceway Prewired Features

FEATURES STANDARD OPTIONS
Communication Devices Ortronics or Activate Connectivity

System Devices

| Other manufacturers
Electrical Devices| Pass & Seymour| Other manufacturers and some International devices
Body Length| Longest = 10′ (2.54m), shortest = 1′ (305mm)| —
Installation| Surface mounted| —
Finish| Baked enamel finish

custom colors

| Standard colors of baked powder epoxy or
Wire Type| THHN stranded| Options per specification
Wiring Splices| Insulation displacement connectors| Continuous wiring or twist-on wire connector
Grounding Conductors| Wire gauge per National Electrical

Code (NEC) and shared grounding wires

| Oversized and/or separate grounding wires
Device Identification| Gray self-adhesive polyester label

with black letters devices available

| Self-adhesive engraved nameplate,

Interlink labeling software for communication

Neutrals| Shared neutral| Oversized and/or separate neutral wires
Pigtails| 12″ (305mm) feeds and receptacle leads| Per specification
Conduit Feeds| Raceway drilled at job site| Entrance end cap
Device Mounting| Steel plates| —
Record Drawings| Three sets and two copies of

marked-up blueprints

| Per job requirements
Submittal Services| Detailed submittal| Submittal free

Ordering Specifications for Prewired Applications

Two options available when ordering a prewired job:

  1. Detailed Submittal The detailed submittal will show exactly how each raceway run will be built including lengths, number and type of receptacles, wiring schematics, circuiting information, etc. The contractor and/or distributor must review, clarify any information not clearly indicated on the drawings or specs, approve and return to the factory before production can begin.
  2. Submittal Free The Wiremold Prewired Checklist is filled out by the contractor or distributor and sent along with plans, casework and specs to the factory. No submittal is required and the project is scheduled for production upon receipt of all necessary information

Device and Raceway Labeling Detail for Prewired Applications

  • Device labeling is available in the following materials: Gray self-adhesive polyester label with black lettering (stan dard). Other color self-adhesive polyester labels. Engraved phenolic nameplates with adhesive back ing.
  • The back of the raceway is labeled with the raceway number and the room or area number(s).legrand-G3046BE-3000&-Series-Duplex-Receptacle-Cover-fig- \(11\)

Raceway Wire Fill Capacities

3000 Series Raceway Wire Fill Capacities For Power

| | NUMBER OF CONDUCTORS (40% Fill)
---|---|---
WIRE SIZE THHN/THWN| O.D.

inches

| ****

(mm)

| WITHOUT DEVICES| WITH DUPLEX/ RECT. DEVICES 1.59 in. 2 (1025mm)| WITH SURGE/ GFCI DEVICES 2.30 in. 2 (1485mm)| LARGE SINGLE RECEPTACLES 3.00 in. 2 (1935mm)
14| AWG| 0.111| (2.8)| 152| 70| 40| 28
12| AWG| 0.130| (3.3)| 111| 51| 29| 21
10| AWG| 0.164| (4.2)| 70| 32| 18| 13
8| AWG| 0.216| (5.5)| 40| 18| 10| 7
6| AWG| 0.254| (6.5)| 29| 13| 7| 5

3000 Series Raceway Cable Fill Capacities for Communications

| CABLE/WIRE SIZE| O.D.

Inches (mm)

| 40% FILL
---|---|---|---
UNSHIELDED TWISTED PAIR| 4-PAIR, 24 AWG Cat 3

4-PAIR, 24 AWG Cat 5e

4-PAIR, 24 AWG Cat 6

4-PAIR, 24 AWG Cat 6a*

25-PAIR, 24 AWG

| 0.190                      (4.8)

0.210                      (5.3)

0.250                      (6.3)

0.354                      (8.9)

0.410                    (10.4)

| 52

42

30

15

11

COAXIAL| RG6/U| 0.270                       (6.9)| 25
FIBER| ZipCord

Round 4 Strand Fiber Round 6 Strand Fiber

| 0.118 x 0.236       (3 x 6)

0.187                       (4.5)

0.256                       (6.5)

| 53

53

28

Category 6 augmented (6a) cable for 10 gigabit ethernet – max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2.
NOTE : All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders
NOTE : The paper used to print this document is an environmentally responsible paper with 10% post-consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy.

ED528R10 – Updated April 2017 – For latest specs visit www.legrand.us/wiremold
© Copyright 2017 Legrand All Rights Reserved Electrical Wiring Systems 60 Woodlawn Street West Hartford, CT 06110
Phone : 1.877.BY.LEGRAND (295-3472)
www.legrand.us
570 Applewood Crescent Vaughan, Ontario L4K 4B4 Phone:905.738.9195
www.legrand.ca

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Legrand User Manuals

Related Manuals