legrand G3033JE Wiremold 3000& Series Single Receptacle Cover
Product Information
The Steel Raceway is a two-piece steel surface raceway designed for wiring applications in frequently changing environments such as labs, hospitals, and other industrial applications. It is part of the 3000 Series Raceway, which is shown in the user manual utilizing data inserts and electrical devices. The raceway has an overlapping cover for easy installation and future changes. It comes with various features and benefits, including entrance knockouts for convenient wiring access, easy mounting on walls or furniture, removable cover for wiring access, compatibility with various receptacles and protective devices, a complete line of fittings for interconnection between raceway systems, availability of prewired options, electrical device identification for easy circuit tracing, compatibility with A/V devices using 5507 Series Faceplates, durable scuff-resistant finish, base and cover cutters for clean and square cuts, datacom connectivity options, UL Listed factory multioutlet assemblies, compliance with UL5 and ADA requirements, and UL Listed and CSA Certified raceway.
Product Usage Instructions
- Choose the appropriate size and length of the Steel Raceway based on your wiring requirements.
- Identify the installation location on walls, modular furniture, under raised floors, or over ceilings.
- If needed, use the base and cover cutters to manually cut the raceway to the desired length.
- Position the raceway on the installation surface and secure it using appropriate mounting hardware.
- If wiring from outside sources is required, use the entrance knockouts spaced along the length of the base to bring in power wiring, communication cables, or A/V cables.
- If using prewired raceway, follow the specified job site lengths and install the raceway accordingly.
- If necessary, install the desired receptacles, circuit breaker housings, or other protective devices into the raceway.
- If using A/V devices, utilize the 5507 Series Faceplates for compatibility.
- Ensure proper electrical device identification for easy circuit tracing. Refer to page six of the user manual for labeling options.
- For datacom connectivity, use industry standard or proprietary devices compatible with the raceway to establish voice, data, audio, and video connections.
- Follow ADA requirements and UL5 specifications for installation in compliance with safety standards.
Two-Piece Steel Surface Raceway
Available Factory Prewired
3000® Series Raceway provides wiring capacities for small to medium size installations. Power, communication, or A/V devices can be wired into the raceway for a flush appearance satisfying both aesthetic and functional requirements. 3000 Series Raceway is ideally suited for wiring applications in frequently changing environments such as labs, hospitals and other industrial applications.
FEATURES & BENEFITS
- Entrance knockouts spaced at regular intervals along length of base. Allows power wiring, communication, or A/V cables to be brought in at a convenient point.
- Mounts easily on walls, modular furniture, under raised floors, or over ceiling. Speeds installation; provides flexibility to bring wiring to points of use.
- Removable cover. Provides access to wiring.
- Accommodates a variety of receptacles, three-pole circuit breaker housings, and other protective devices. Provides flexibility for sophisticated wiring systems.
- Complete line of fittings. Provides a complete wiring solution and allows for interconnection between raceway systems.
- Available prewired. Manufactured to specified job site lengths, raceway comes electrically prewired, ready to install. Jobs can be packaged by room, area, floor, or building and shipped per your job site requirements.
- Electrical device identification for prewired raceway. See six for labeling options. Eliminates guesswork or time-consuming circuit tracing and speeds additions and renovations.
- Compatible with A/V devices by using 5507 Series Faceplates.
- Gray baked enamel and ivory ScuffCoat™ finish. Durable ivory ScuffCoat finish makes a scratch resistant surface.
- Base and cover cutters. Manually operated cutters are lightweight and portable. Cutters offer labor savings for any size job and maintain a factory clean and square cut.
- Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
- UL Listed factory multioutlet assemblies. Listed by Underwriters Laboratories Inc. Multioutlet assemblies file number E15191 Guide (PVGT)/ Fittings file number E41751 Guide (RJPR).
- UL5 and ADA compliant. Raceway and fittings meet UL5 specifications and can be installed in conformance with ADA requirements.
- UL Listed and CSA Certified raceway. Listed by Underwriters Laboratories Inc. Raceway file number E4376 Guide (RJBT)/ Fittings file number E41751 Guide (RJPR) CSA Certified LR350.
Download this product’s PEP ecopasport® environmental product declaration at
www.legrand.us/resources-and-downloads.
This declaration conforms with ISO 14025 and 14040 and is in alignment with EN
15804.
System Layout
3000 Series System Layout
NOTE: Illustration is for showing product applications only.
Ordering Information
3000 Series Raceway Ordering Information
Catalog No./Item /Description/Specifications
Add C prefix to denote Canadian version – CSA Certified.
3000 Series Raceway Prewired Features
3000 Series Raceway Prewired Features
FEATURES| STANDARD| OPTIONS
Communication Devices| Ortronics or Activate Connectivity
System Devices
| Other manufacturers
Electrical Devices| Pass & Seymour| Other manufacturers and some
International devices
Body Length| Longest = 10′ (2.54m), shortest = 1′ (305mm)| —
Installation| Surface mounted| —
Finish| Baked enamel finish
custom colors
| Standard colors of baked powder epoxy or
Wire Type| THHN stranded| Options per specification
Wiring Splices| Insulation displacement connectors| Continuous wiring or
twist-on wire connector
Grounding Conductors| Wire gauge per National Electrical
Code (NEC) and shared grounding wires
| Oversized and/or separate grounding wires
Device Identification| Gray self-adhesive polyester label
with black letters devices available
| Self-adhesive engraved nameplate,
Interlink labeling software for communication
Neutrals| Shared neutral| Oversized and/or separate neutral wires
Pigtails| 12″ (305mm) feeds and receptacle leads| Per specification
Conduit Feeds| Raceway drilled at job site| Entrance end cap
Device Mounting| Steel plates| —
Record Drawings| Three sets and two copies of
marked-up blueprints
| Per job requirements
Submittal Services| Detailed submittal| Submittal free
Applications
3000 Series Ordering Specifications for Prewired Applications
Two options available when ordering a prewired job:
- Detailed Submittal: The detailed submittal will show exactly how each raceway run will be built including lengths, number and type of receptacles, wiring schematics, circuiting information, etc. The contractor and/or distributor must review, clarify any information not clearly indicated on the drawings or specs, approve and return to the factory before production can begin.
- Submittal Free: The Wiremold Prewired Checklist is filled out by the contractor or distributor and sent along with plans, casework and specs to the factory. No submittal is required and the project is scheduled for production upon receipt of all necessary information.
Device and Raceway Labeling Detail for Prewired Applications
- Device labeling is available in the following materials:
- Gray self-adhesive polyester label with black lettering (stan dard).
- Other color self-adhesive polyester labels.
- Engraved phenolic nameplates with adhesive back ing.
- The back of the raceway is labeled with the raceway number and the room or area number(s).
3000 Series Raceway Wire Fill Capacities
3000 Series Raceway Wire Fill Capacities For Power
3000 Series Raceway Wire Fill Capacities For Power
| | NUMBER OF CONDUCTORS (40% Fill)
WIRE SIZE THHN/THWN| O.D.
inches
| ****
(mm)
| WITHOUT DEVICES| WITH DUPLEX/ RECT. DEVICES 1.59 in. 2
(1025mm)| WITH SURGE/ GFCI DEVICES 2.30 in. 2 (1485mm)|
LARGE SINGLE RECEPTACLES 3.00 in. 2 (1935mm)
14| AWG| 0.111| (2.8)| 152| 70| 40| 28
12| AWG| 0.130| (3.3)| 111| 51| 29| 21
10| AWG| 0.164| (4.2)| 70| 32| 18| 13
8| AWG| 0.216| (5.5)| 40| 18| 10| 7
6| AWG| 0.254| (6.5)| 29| 13| 7| 5
3000 Series Raceway Cable Fill Capacities for Communications
3000 Series Raceway Cable Fill | Capacities for Communicatio | ns |
---|---|---|
CABLE/WIRE SIZE | O.D. |
Inches (mm)
| 40% FILL
UNSHIELDED TWISTED PAIR| 4-PAIR, 24 AWG Cat 3
4-PAIR, 24 AWG Cat 5e
4-PAIR, 24 AWG Cat 6
4-PAIR, 24 AWG Cat 6a*
25-PAIR, 24 AWG
| 0.190 (4.8)
0.210 (5.3)
0.250 (6.3)
0.354 (8.9)
0.410 (10.4)
| 52
42
30
15
11
COAXIAL| RG6/U| 0.270 (6.9)| 25
FIBER| ZipCord
Round 4 Strand Fiber Round 6 Strand Fiber
| 0.118 x 0.236 (3 x 6)
0.187 (4.5)
0.256 (6.5)
| 53
53
28
-
- Category 6 augmented (6a) cable for 10 gigabit ethernet – max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2.
NOTE: All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders.
NOTE: The paper used to print this document is an environmentally responsible paper with 10% post consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy.
For latest specs visit: www.legrand.us/wiremold
Contacts
Electrical Wiring Systems
- 60 Woodlawn Street
- West Hartford, CT 06110
- Phone: 1.877.BY.LEGRAND (295-3472)
- www.legrand.us
- 570 Applewood Crescent
- Vaughan, Ontario L4K 4B4
- Phone: 905.738.9195
- www.legrand.ca
© Copyright 2017 Legrand All Rights Reserved
References
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- Resources
- Wiremold Wire and Cable Management Products from Legrand
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>