legrand G3000WC 3000 Series Wire Clip Galvanized Fitting Owner’s Manual
- June 13, 2024
- Legrand
Table of Contents
- WIREMOLD®
- Steel Raceway
- Two-Piece Steel Surface Raceway
- Available Factory Prewired
- FEATURES & BENEFITS
- 3000 Series System Layout
- 3000 Series Raceway Ordering Information
- 3000 Series Raceway Prewired Features
- 3000 Series Ordering Specifications for Prewired Applications
- Device and Raceway Labeling Detail for Prewired Applications
- 3000 Series Raceway Wire Fill Capacities
- NOTES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WIREMOLD®
Steel Raceway
Two-Piece Steel Surface Raceway
Available Factory Prewired
3000® Series Raceway provides wiring capacities for small to medium size
installations. Power, communication, or A/V devices can be wired into the
raceway for a flush appearance satisfying both aesthetic and functional
requirements.
3000 Series Raceway is ideally suited for wiring applications in frequently
changing environments such as labs, hospitals and other industrial
applications.
3000 Series Raceway shown utilizing data inserts and electrical devices.
3000 Series Single Channel Raceway has an overlapping cover allowing easy installation and future changes.
FEATURES & BENEFITS
- Entrance knockouts spaced at regular intervals along length of base. Allows power wiring, communication, or A/V cables to be brought in at a convenient point.
- Mounts easily on walls, modular furniture, under raised floors, or over ceiling. Speeds installation; provides flexibility to bring wiring to points of use.
- Removable cover. Provides access to wiring.
- Accommodates a variety of receptacles, three-pole circuit breaker housings, and other protective devices. Provides flexibility for sophisticated wiring systems.
- Complete line of fittings. Provides a complete wiring solution and allows for interconnection between raceway systems.
- Available prewired. Manufactured to specified job site lengths, raceway comes electrically prewired, ready to install. Jobs can be packaged by room, area, floor, or building and shipped per your job site requirements.
- Electrical device identification for prewired raceway. See page six for labeling options. Eliminates guesswork or time-consuming circuit tracing and speeds additions and renovations.
- Compatible with A/V devices by using 5507 Series Faceplates.
- Gray baked enamel and ivory ScuffCoat™ finish. Durable ivory ScuffCoat finish makes a scratch resistant surface.
- Base and cover cutters. Manually operated cutters are lightweight and portable. Cutters offer labor savings for any size job and maintain a factory clean and square cut.
- Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
- UL Listed factory multioutlet assemblies. Listed by Underwriters Laboratories Inc. Multioutlet assemblies file number E15191 Guide (PVGT)/ Fittings file number E41751 Guide (RJPR).
- UL5 and ADA compliant. Raceway and fittings meet UL5 specifications and can be installed in conformance with ADA requirements.
- UL Listed and CSA Certified raceway. Listed by Underwriters Laboratories Inc. Raceway file number E4376 Guide (RJBT)/ Fittings file number E41751 Guide (RJPR) CSA Certified LR350.
Download this product’s PEP ecopasport® environmental product declaration at www.legrand.us/resources-and-downloads. This declaration conforms with ISO 14025 and 14040 and is in alignment with EN 15804.
ED528R10 – Updated April 2017 – For latest specs visitwww.legrand.us/wiremold
3000 Series System Layout
- G3086A (Available by special order)
- Panel Box (Supplied by others)
- 1/2″ (12.7mm) or 3/4″ (19.1mm) Metal Conduit
- 1/2″ (12.7mm) Flexible Metal Conduit
NOTE: Illustration is for showing product applications only.
3000 Series Raceway Ordering Information
Catalog No./Item | Description/Specifications |
---|
G3000B
V3000B| Base – .040″ steel, Packed 100 ft. per carton, ten 10 ft.
(3.05m) lengths.
G3000CE
V3000CE| Cover – .040″ steel. Packed 100 ft. per carton, (20) 5 ft.
(1.50m) lengths.
G3000C075
V3000C075| 7.5″ (191mm) Precut Cover – For mounting devices on 12″
(305mm) centers with 3033JE, 3036HE, 3040CE, 3043, 3043BE, 3043GE, 3048R,
3027AE, and 3051LE Series plates.
G3000C195
V3000C195| 19.5″ (495mm) Precut Cover – For mounting devices on 24″
(610mm) centers with 3033JE, 3036HE, 3040CE, 3043, 3048R, 3027AE, and 3051LE
Series plates.
630B
| Base Cutter – Portable base cutter. Provides clean and easy square
cuts. Manual operation required.
630BDK| Replacement Blade Kit –
630C
| Cover Cutter – Portable cover cutter. Provides clean and easy square
cuts. Manual operation required.
630CDK| Replacement Blade Kit –
G3000WC
| Wire Clip (Plated) – For holding conductors in place.
G3001
| Coupling (Galvanized Steel Unpainted) – For joining lengths of 3000
Series Raceway.
G3001A
| Rigid Inside Coupling (Galvanized Steel Unpainted) – For joining
lengths of 3000 Series Raceway when added rigidity is required, i.e. raceway
suspended overhead.
G3003
| Supporting Clip – For supporting lengths of 3000 Series Raceway at any
point. Mount with #8 flat head fastener. Has set screw for locking to raceway.
G3006E/V3006E
| Cover Clip – For covering uneven cut joint of 3000 Series Raceway
Cover.
G3007C
| Device Bracket – For mounting standard single-gang devices (with 3.3″
(83.82mm) mounting straps), Activate Connectivity inserts and faceplates. Can
be used with commercially available flush plate (not furnished).
G3008C
| C-Hanger – For suspending 3000 Series Raceway from structural ceiling.
Designed for use with 3/8″ (9.5mm) threaded rod. Use one hanger at least every
4 feet (1.2 m) of length.
V3010AE
G3010AE| Entrance End – For connecting to 1/2″ conduit and armored
cable connectors. 1/2″ trade size KO on end and each side. May be connected to
conduit boxes by using 1/2″ (12.7mm) chase nipple. (not included)
G3010B
V3010B| Blank End – For closing open end of 3000 Series Raceway. Has
concentric 1/2″ and 3/4″ trade size KOs.
G3010C
V3010C| Entrance End – For connecting to rigid or flexible conduit.
Concentric 1/2″, 3/4″, and 1″ trade size KOs on end and each side.
G3011E
V3011E| 90° Flat Elbow – For right angle turns on same surface.
G3014C
V3014C| Wall Box Connector – For connecting from flushed-in wall
box.
G3015E
V3015E| Tee – For branches at right angles. Couplings furnished.
V3017TCE
G3017TCE| Internal Corner Coupling – For surfaces at right angles,
or for use as a straight-through fitting. Solid leg of base has concentric
1/2″ and 3/4″ trade size KO.
|
#6 AWG
| #8 AWG| #10 AWG| #12 AWG| #14 AWG
THNN, THWN| 13| 18| 24| 55|
75
Wire capacity when used as a straight through fitting.
G3018AE
V3018AE| External Corner – For right angle turns around external
corners.
G3027AE **
V3027AE **| Single Receptacle Cover – For installing commercially
available straight blade and locking single receptacles with face diameters of
1.38-1.40″ (35.1-35.6mm). G3007C Device Bracket included.
G3028
V3028| Utility Box – Cover has twistouts on four sides. May be used
as a tee, cross, junction box, or for branch circuit extensions. Base has five
1/2″ trade size KOs and four holes for fixture stud.
G3033JE ****
V3033JE **| Single Receptacle Cover – For installing of
commercially available straight blade and locking single receptacle with face
diameters of 1.56-1.57″ (39.6- 40mm). G3007C Device Bracket included.
G3036HE **
V3036HE ****| Blank Cover – Cover has 1/2″ trade size KO in
center. G3007C Device Bracket included.
G3040CE
V3040CE| Switch Cover – For installing commercially available
single-pole, two-pole, three-way or four- way switches. G3007C Device Bracket
included.
G3043BE ****
V3043BE ****| Duplex Receptacle Cover – For installing
commercially available 15A and 20A duplex receptacles. G3007C Device Bracket
included. Accepts 106 Frame.
G3043GE ****
V3043GE ****| Duplex Grounding Receptacle and Cover – Same as
3043BE except with 15A/125V (NEMA 5-15R) grounding receptacle furnished.
G3007C Device Bracket included.
G3044-2 ****
V3044-2 ****| Extra Deep Switch and Receptacle Box – Two-gang.
For standard 30, 50, and 60A receptacles. Two sides of cover have one set of
combination twistouts for 3000 and 2100 Series Raceway: two sides have two
sets. Rectangular hole-cut in cover: 3 3/4″ x 2 7/8″ (95mm x 73mm). Base has
1″ and 1 1/2″ trade size concentric KOs.
G3046BE ****
V3046BE ****
| Duplex Receptacle Cover – For installing commercially available 15A and
20A duplex receptacles. Accepts 106 Frame.
G3046H-2
V3046H-2
| Tap-Off Fitting – Has concentric 1/2″ and 3/4″ trade size KOs and
twistout for telephone cables. Grommet furnished for telephone KO.
V3046KD
G3046KD
| Circuit Breaker Housing – For covering single pole breaker. Remove KO
for two-pole.
G3046KTSQ/V3046KTSQ
| Circuit Breaker Housing – For mounting Square D Quik-Gard QOB bolt-on
circuit breakers rated up to 50A maximum. Furnished with Square D QON3B
compact base for single to Three-pole circuit breakers. For GFI breakers, use
Square D QOB-GFI Series.
G3046QOU
V3046QOU| Circuit Breaker Housing – For mounting Square D Type QOU
one-, two-, or three-pole breakers rated up to 50A maximum.
|
#6 AWG
| #8 AWG| #10 AWG| #12 AWG| #14 AWG
THNN, THWN| 6| 8| 10| 18|
26
Wire capacity of 3000 Raceway with 3046KD, KTSQ, QOU circuit breaker housings.
V3046U
G3046U| Bump-Up Extron® MAAP Plate – Device plate for use with four
Extron® Electronics MAAP single space modules.
V3046V
G3046V| Bump-Up Extron® AAP Plate – Device plate for use with two
Extron® Electronics AAP single space modules.
V3046S
G3046S| Bump-Up Plate – for Wiremold® CM2 modules or Ortronics®
TracJack or Series II inserts. Device plate accepts three (3) CM2 modules or
six (6) TracJack connectors or three (3) Series II inserts.
G3048R
V3048R| Rectangular Receptacle Cover – For installing commercially
available 15A and 20A rectangular receptacles. G3007C Device Bracket included.
- Accepts Decorator style communication devices
G3051LE ****
V3051LE **** ****| Extension Cover – Accepts shallow-type
30A and 50A devices and flush plates. Deeper devices can be accommodated with
a combination of 3051LE and any of the V5700 Series single-gang, open base
boxes. G3007C Device Bracket included.
- Accepts standard single- gang faceplates.
G3082
| Conduit Connector – To connect end of 3000 Series Raceway with 1 1/2″
trade size conduit or armored cable.
IWE-S
GWE-S| Spray Paint – Used for touching up large areas. Contains 12
oz. of paint.
NOTE: Can only be shipped via ground transportation.
IWE-P
GWE-P| Touch-Up Paint Pen – Used for touching up small areas.
Contains 0.3 oz.of paint.
** Add C prefix to denote Canadian version – CSA certified.**
3000 Series Raceway Prewired Features
FEATURES
| STANDARD|
OPTIONS
---|---|---
Communication Devices| Ortronics or Activate Connectivity System
Devices| Other manufacturers
Electrical Devices| Pass & Seymour| Other manufacturers and some
International devices
Body Length| Longest = 10′ (2.54m), shortest = 1′ (305mm)| —
Installation| Surface mounted| —
Finish| Baked enamel finish
custom colors| Standard colors of baked powder epoxy or
Wire Type| THHN stranded| Options per specification
Wiring Splices| Insulation displacement connectors| Continuous wiring or
twist-on wire connector
Grounding Conductors| Wire gauge per National Electrical Code (NEC) and
shared grounding wires| Oversized and/or separate grounding wires
Device Identification| Gray self-adhesive polyester label with black
letters
devices available| Self-adhesive engraved nameplate,
Interlink labeling software for communication
Neutrals| Shared neutral| Oversized and/or separate neutral wires
Pigtails| 12″ (305mm) feeds and receptacle leads| Per specification
Conduit Feeds| Raceway drilled at job site| Entrance end cap
Device Mounting| Steel plates| —
Record Drawings| Three sets and two copies of marked-up blueprints| Per
job requirements
Submittal Services| Detailed submittal| Submittal free
3000 Series Ordering Specifications for Prewired Applications
Two options available when ordering a prewired job:
3000 Series Raceway shown electrically prewired.
1. Detailed Submittal| The detailed submittal will show exactly how
each raceway run will be built including lengths, number and type of
receptacles, wiring schematics, circuiting information, etc. The contractor
and/or distributor must review, clarify any information not clearly indicated
on the drawings or specs, approve and return to the factory before production
can begin.
---|---
2. Submittal Free| The Wiremold Prewired Checklist is filled out by the
contractor or distributor and sent along with plans, casework and specs to the
factory. No submittal is required and the project is scheduled for production
upon receipt of all necessary information.
Device and Raceway Labeling Detail for Prewired Applications
-
Device labeling is available in the following materials:
Gray self-adhesive polyester label with black lettering (standard).
Other color self-adhesive polyester labels.
Engraved phenolic nameplates with adhesive backing. -
The back of the raceway is labeled with the raceway number and the room or area number(s).
3000 Series Raceway Wire Fill Capacities
3000 Series Raceway Wire Fill Capacities For Power
| | NUMBER OF CONDUCTORS (40% Fill)
---|---|---
WIRE SIZE THHN/THWN| O.D.| WITHOUT DEVICES| WITH DUPLEX/
RECT. DEVICES
1.59 in.² (1025mm)| WITH SURGE/ GFCI DEVICES
2.30 in.² (1485mm)|
LARGE SINGLE RECEPTACLES
3.00 in.² (1935mm)
inches
|
(mm)
14 AWG
| 0.111| (2.8)| 152| 70| 40| 28
12 AWG| 0.130| (3.3)| 111| 51| 29|
21
10 AWG
| 0.164| (4.2)| 70| 32| 18| 13
8 AWG| 0.216| (5.5)| 40| 18| 10|
7
6 AWG
| 0.254| (6.5)| 29| 13| 7|
5
3000 Series Raceway Cable Fill Capacities for Communications
|
CABLE/WIRE SIZE
| O.D.| 40% FILL
---|---|---|---
Inches|
(mm)
UNSHIELDED TWISTED PAIR
| 4-PAIR, 24 AWG Cat 3| 0.190| (4.8)| 52
4-PAIR, 24 AWG Cat 5e| 0.210| (5.3)|
42
4-PAIR, 24 AWG Cat 6
| 0.250| (6.3)| 30
4-PAIR, 24 AWG Cat 6a*| 0.354| (8.9)|
15
25-PAIR, 24 AWG
| 0.410| (10.4)| 11
COAXIAL| RG6/U| 0.270| (6.9)|
25
FIBER
| ZipCord| 0.118 x 0.236| (3 x 6)| 53
Round 4 Strand Fiber| 0.187| (4.5)|
53
Round 6 Strand Fiber
| 0.256| (6.5)|
28
* Category 6 augmented (6a) cable for 10 gigabit ethernet – max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2.
NOTES
NOTE: All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders.
NOTE: The paper used to print this document is an environmentally responsible paper with 10% post consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy.
Electrical Wiring Systems
60 Woodlawn Street
West Hartford, CT 06110
Phone: 1.877.BY.LEGRAND (295-3472)
www.legrand.us
570 Applewood Crescent
Vaughan, Ontario L4K 4B4
Phone:905.738.9195
www.legrand.ca
ED528R10 – Updated April 2017 – For latest specs
visitwww.legrand.us/wiremold
© Copyright 2017 Legrand All Rights Reserved
References
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- Resources
- Wiremold Wire and Cable Management Products from Legrand
Read User Manual Online (PDF format)