Product Information

  • Product: Non-contact Thermometer
  • Model: KF-HW-005
  • Manufacturer: Cofoe Medical Technology Co., Ltd.
  • Address: 816 Zhenhua Road, Yuhua District, 410000 Changsha, Hunan, PEOPLE’S REPUBLIC OF CHINA
  • Importer: mPTech Sp. z o. o.
  • Address: ul. Nowogrodzka 31, 00-511 Warszawa, Polska
  • Infoline: (+48 71) 71 77 400
  • Produced in China
  • Instruction Manual Release Date: June 2022

Product Usage Instructions

Usage according to the intended purpose

Before using, carefully read the entire user manual and keep itfor future reference.

Safety precautions

CAUTION:

  • Follow all safety instructions provided in the user manual.
  • Keep out of reach of children.

Technical specifications

Technical data:

  • Measurement method: Non-contact
  • Measurement distance: Not specified
  • Measurement range: Not specified
  • Maximum allowable measurement error: Not specified
  • Measurement accuracy: Not specified
  • Operating temperature/humidity: Not specified
  • Storage temperature/humidity: Not specified
  • Operating atmosphere: Not specified
  • Power supply: 3 V, 2 x AAA 1.5 V batteries
  • Backlight display: Yes
  • High contrast backlight: Yes
  • Temperature scale: Celsius or Fahrenheit
  • Automatic shutdown: After approximately 30 seconds
  • Software version: V455

Package contents:

  • Non-contact Thermometer
  • Velour cover
  • 2 x AAA 1.5V batteries
  • User manual

The user manual can be downloaded from the following website: https://mptech.eu/qr/huslog.Or by scanning the QR code provided in the manual.

Device structure:

  1. Function button
  2. Display
  3. Battery compartment cover
  4. M button
  5. Infrared sensor

Device operation:

Battery installation and replacement:

Follow the instructions below to install or replace the  batteries:

  1. Open the battery compartment cover (3).
  2. Insert 2 x AAA 1.5V batteries as indicated.
  3. Close the battery compartment cover securely.

Temperature measurement:

Ensure that the forehead is free from hair, caps, etc., as they may affect the measurement result. The measurement result is for informational purposes only. If in doubt, use an alternative method to measure temperature.

The device can be used for body temperature measurement (symbol ) and surface temperature measurement of objects (symbol ), depending on the measurement result:

  • Temperature
  • Color
  • Signal
  • Display backlight indication
  • Note: The specific temperature ranges and correspondingindications are not specified in the user manual.

Warranty and Service

  • For warranty and service information, refer to the user  manual.

Declaration of Conformity with EU Directives

  • The device complies with EU directives. Refer to the user manual for more information.

Electromagnetic Compatibility

  • The device is compatible with electromagnetic fields. Refer tothe user manual for more information.

Intended use

  • The device is used to measure and control body temperature by measuring the thermal radiation of the forehead. The thermometer is intended for non-commercial, private use only. Any other use is improper and dangerous.
  • The manufacturer is not liable for damages resulting from the use of the device in a manner inconsistent with its intended use.

Safety of use

Read the entire user manual carefully before use. Keep it for future reference.

CAUTION:

  • Do not charge non-rechargeable batteries (other than accumulators).
  • Do not short-circuit the battery power terminals.
  • Use batteries of the same type as recommended for this device.
  • When installing new batteries, remember to check the +/- polarity of the batteries.
  • Remove discharged batteries immediately from the unit, as they may leak and cause damage.
  • Always remove the batteries when not in use – this will prevent the product from being damaged if the electrolyte leaks from the battery. Always replace the entire battery pack with a functional one.
  • Keep batteries away from children and animals.
  • Do not dispose of your used batteries in a waste bin, but in special containers for used batteries and accumulators.
  • Avoid exposing the battery to very high/low temperatures (below 0°C/32°F and over 40°C/104°F). Extreme temperatures can affect their service life.
  • Avoid contact with liquids and metal objects, as this may result in total or partial damage to the battery.
  • Place worn or damaged batteries in a special container.
  • Never expose batteries to direct sunlight, radiators, fire or excessive heat.
  • Never dispose of batteries into a fire – they may explode.
  • Never immerse batteries in water. Do not touch the batteries with wet hands.
  • If hands come into contact with acid from the battery, rinse hands under running water. If electrolyte gets into your eyes, contact your doctor. Acid contained in batteries may cause skin irritation or chemical burns.
  • Swallowing batteries can be fatal! Keep batteries away from children and pets. Immediately seek medical attention if the battery is swallowed.
  • WARNING! In order to ensure adequate safety measures and operating conditions, the battery should only be mounted by adults.
  1. Always abide by any kinds of prohibitions, regulations and warnings conveyed by the staff of the entity where you wish to use the device.
  2. Do not use the device near flammable fabrics.
  3. This device may only be used by adults.
  4. Children must not play with this device – it is not a toy.
  5. Keep the device, its packaging and accessories out of reach of children and pets.
  6. The device should not be operated or stored in dusty environments.
  7. Unattended children must not clean or maintain the unit. Cleaning and maintenance of the appliance must be carried out as described in section 7. Cleaning and conservation.
  8. Avoid exposing the device to very low or very high temperatures (below 5°C / 41°F or above 40°C / 104°F during operation and below -20°C / -7.6°F or above 55°C / 131°F during storage and transportation). Extreme temperatures can affect service life of the device.
  9. The device should not be used in dusty conditions. Make sure that animals do not have access to the product. Damaged product can have cracks or broken parts with dangerous sharp edges. Do not expose the device to sunlight and do not place it in close proximity to heat-generating devices. Plastic parts may deform, which may affect the operation of the device or cause it to break down completely.
  10. Do not immerse the device in water or other liquids, as wetting will harm the electronics and may damage the equipment.
  11. Do not use the unit if it has fallen to the ground or is visibly damaged.
  12. The device is used to measure and control body temperature. It should be used in front of the uncovered forehead at a distance of about 1-3 cm. The device can also indicate the approximate surface temperature of the object at which it is aimed from a distance of approximately 1-3 cm.
  13. Taking a measurement is not equivalent to a professional diagnosis. The diagnosis can only be made by a doctor or a trained and authorized person. In case of bad results always contact a physician.
  14. You are not allowed to change the dosage of medicines by yourself, without consulting your doctor, only on the basis of the measurement.
  15. Make sure that the device is not exposed to magnetic field interference, as this may affect the measurement results.
  16. Careful with small parts – choking hazard.
  17. Only qualified personnel or an authorized service centre may install or repair this product. Repair of the device by an unqualified service or by an unauthorised service centre, as well as unauthorised modifications on your own, may damage the device and void the warranty.

Technical Specification

Technical data

Touchless thermometer

Model| KF-HW-005
Method of measurement| Touchless
Distance of measurement| 1 – 3 cm
Measuring range| 32 – 43 ºC (body temp.)
Maximum permissible measurement error| ± 0.3 ºC if between 32 – 34.9 ºC

± 0.2 ºC if between 35 – 42 ºC

± 0.3 ºC if between 42.1 – 43 ºC

Accuracy of measurement| 0.1 ºC
Working humidity/Temperature| 10 – 40 ºC / ≤85%
Storing humidity/Temperature| -20 – 55 ºC / ≤93%
Working           atmospheric pressure| 70 – 106 kPa
Power supply| 3 V⎓, 2 x AAA 1,5 V⎓ battery
Display backlighting| High contrast backlight
Temperature scope| Celsius or Fahrenheit degree scale
Automatic power off| After about 30 seconds.
Software version| V455

Package content

  1. Touchless thermometer
  2. Case
  3. 3 V⎓, 2 x AAA battery 1,5 V⎓
  4. User Manual
  • If any of the above items is missing or damaged, please contact your dealer.
  • We advise to keep the container in case of any complaints. Keep the container out of reach of children.

You print a version of the user manual with the large font size or download it from the web address below: https://mptech.eu/qr/huslog.

Device construction

  1. Function button
  2. Display
  3. Flap of the battery compartment
  4. M button
  5. Infrared sensor

Operation of the device

Installation and replacement of batteries

  • Slide the battery compartment flap (3) towards the bottom of the unit and remove it. When replacing batteries, always replace the complete set of two batteries and dispose of them according to regulations. Place a new set of batteries in the battery compartment according to the polarity marking inside the battery compartment.
  • Close the battery compartment by sliding the tab back into place so that the latch engages and secures the compartment against opening.
  • If you do not plan to use the thermometer for several months or longer, remove the batteries from the battery compartment.

Temperature measurement

  • Do not touch the sensor with your fingers or other objects.
  • If the ambient temperature has changed significantly (e.g. change of room), leave the thermometer for about 30 minutes to adjust to it. Make sure that the ambient temperature is within the operating temperature range of the instrument (10 – 40 ºC) before taking the measurement.
  • Take temperature measurements in a stable environment. If the ambient temperature changes, check that the infrared sensor is not fogged up.
  • Covering the forehead with hair, a cap, etc. may affect the measurement result.
  • The result of the measurement is informative. If in doubt, measure the temperature using another method.
  • Once the batteries have been correctly installed, the device enters standby mode and is ready for use immediately. Briefly press the function key (1) to initiate the measurement. The illuminated display (2) of the device shows all its elements for about a second, after which the result of the last measurement is displayed for another second until three horizontal lines appear on the display. At this point, briefly pressing the M button (4) allows you to choose between measuring the body temperature (symbol at the top of the display) and the surface temperature of the object (symbol ).
  • After selecting the temperature measurement mode, point the infrared sensor (5) at the uncovered forehead or the selected object at a distance of approx. 1-3 cm and briefly press the function button. The measurement result will be displayed after about one second and a beep. For about 18 seconds after the last press of the function button, further temperature measurements can be taken.
  • If no action is taken during that time the device will enter a sleep mode.
  • The display backlight can take on one of three colours depending on the measurement result:

Temperature| Backlight colour| Sound signal| Display
---|---|---|---
Too low| Red| Two short| „Lo”
Normal| Green| One long| Measurement result
Elevated| Orange| Three short| Measurement result
Too high| Red| Three short| Measurement result
Above upper limit| Red| Two short| „Hi”

Measurement memory

  • While the unit is in standby, a short press of the M button (4) allows you to view up to the last 50 measurements stored in the unit’s memory. Subsequent presses of this button display successive results in a loop. First the result number appears briefly on the display (2), followed by the result itself. The result with the lowest number is the most recent. If the function button (1) is pressed or if the device is left inactive for about 18 seconds the thermometer switches to the standby mode.

Basic settings

  • While the device is in standby, long press and hold the M button (4) to set the temperature scale in which the measurements will be displayed. Briefly press the M button to switch between Celsius and Fahrenheit. Confirm your choice by pressing the function key (1) briefly. In the measurement memory viewing mode, long pressing of the M button clears the measurement memory of the instrument. While the unit is in standby, briefly press the function key. When the display shows three horizontal bars, a long press on the M button will switch the audible indication on and off.

Troubleshooting

  • In case of any problems with the device, please refer to the following tips.

The device does not switch on| Check that there are batteries installed. Check if the batteries are not discharged.

Check that the batteries have been installed in accordance with the polarity marking inside the battery compartment.

---|---
“Lo” flashes in the display and the device beeps four times| Battery charge level is low. The device is unable to perform measurements. Change the batteries.
The ERR symbol appears in the display.| The ambient temperature is outside the operating temperature range of the unit. Place the device in an environment where the temperature is within the working range of the thermometer and wait about 30 minutes before taking a measurement.
“Lo” appears on the display and its backlight is red| The result of the performed measurement is below the lower limit of the body temperature measurement range (32ºC).
“Hi” appears on the display and its backlight is red| The result of the performed measurement is above the higher limit of the body temperature measurement range (43ºC).
---|---
The display flashes in the display and the device beeps four times| There was an IR sensor error or a general hardware error. Contact the manufacturer’s service department.
If the problem persists, contact service center.

Cleaning And Maintenance

  • The device may only be cleaned with a dry cloth or paper towel. It is forbidden to use water or any other liquids to clean the device.
  • No part of the device may be submerged in water.
  • Cleaning and maintenance may only be carried out when the appliance is switched off.
  • Avoid very high temperatures, as they can shorten the service life of the electronic components of the device and melt plastic parts.

Explanations of the symbols

  • The device is marked with a crossed-out garbage bin, in accordance with the European Directive 2012/19/EU on used electrical and electronic Equipment (Waste Electrical and Electronic equipment – WEEE). Products marked with this symbol should not be disposed of or dumped with other household waste after a period of use. The user is obliged to get rid of used electrical and electronic equipment by delivering it to designated recycling point in which dangerous waste are being recycled. Collecting this type of waste in designated locations, and the actual process of their recovery contribute to the protection of natural resources. Proper disposal of used electrical and electronic equipment is beneficial to human health and environment. To obtain information on where and how to dispose of used electrical and electronic equipment in an environmentally friendly manner user should contact their local government office, the waste collection point, or point of sale, where the equipment was purchased.

  • In accordance with Directive 2006/66/EC as amended by Directive 2013/56/EU on the disposal of batteries and accumulators, this product is marked with the symbol of a crossed-
    out waste bin. The symbol indicates that the batteries used in this product should not be disposed with regular household waste, but treated according to the legal directives and local regulations. It is not allowed to dispose of batteries and accumulators with unsorted municipal waste. Users of batteries and accumulators must use the available collection points of these items, which allows them to return, recycle and disposal.

  • Within the EU, the collection and recycling of batteries and accumulators is a subject to separate procedures. To learn more about existing procedures of recycling of batteries and accumulators please contact your local office or an institution for waste disposal or landfill.

The use of the manual

  • Without prior written consent of the manufacturer, no part of this manual may be photocopied, reproduced, translated or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording or storing in any systems of storing and sharing information. All brand names and product names are trademarks or registered trademarks of their respective companies.
  • Please keep this manual in order to be able to refer to it while using the product.

Warranty and service

  • The product is covered by a 2-year warranty, counting from the date of sale of the product. If you need to make use of a warranty claim, please contact the manufacturer’s helpline or point of sale. The product returned for warranty claim should be complete and in its original packaging.

Declaration of conformity with European Union Directives

  • This device meets the requirements of the European Commission Directive 93/42/EEC on Medical Devices.

Electromagnetic compatibility

Guidelines and manufacturer’s declaration – electromagnetic

emission


Emission test| Conformity
Radio frequency emission

CISPR 11

| Group 1
Radio frequency emission

CISPR 11

| B class
Harmonic emissions

IEC 61000-3-2

| No use
Surges/flicker emissions

IEC 61000-3-3

| No use
Guidelines and manufacturer’s declaration – electromagnetic resistance

Durability test| Test level IEC 60601-1-2| Conformity level
Electrostatic discharges (ESD) IEC 61000-4-2| +/- 8 kV contact.

+/- 2 kV, +/- 4 kV,

+/- 8 kV, +/- 15 kV

air

| +/- 8 kV contact.

+/- 2 kV, +/- 4 kV, +/-

8 kV, +/- 15 kV air

Electrical fast transient/pulse IEC 61000-4-4| No use| No use
Surge

IEC 61000-4-5

| No use| No use
Voltage collapses, short interruptions and fluctuations in the supply voltage on supply lines

IEC 61000-4-11

| ****


No use

| ****


No use

Mains frequency

magnetic field IEC 61000-4-8

| 30 A/m

50/60 Hz

| 30 A/m

50/60 Hz

Conducted radio signal

IEC 61000-4-6

| No use| No use
Emitted radio frequency signal IEC 61000-4-3| 10 V/m

80 MHz – 2.7

GHz

80% AM at 1 kHz

| 10 V/m

80 MHz – 2.7 GHz

80% AM at 1 kHz

NOTE: UT is the AC supply voltage before applying the test level
Guidelines and manufacturer’s declaration – electromagnetic resistance

Emitted radio frequency signal IEC 61000-4-3

(Test specification for the CABINET PORT RESISTANCE to RF signal of wireless

communication equipment)

Text frequency (MHz)| Band (MHz)| ****

Service

| ****

Modulation

| Max. power (W)| Distance (m)| Level of durability test (V/m)


385

| 380-

390

| ****

TETRA 400

| Impulse modulation 18 Hz| ****

1.8

| ****

0.3

| ****

27



450

| ****

430-

470

| ****

GMRS 460,

FRS 460

| FM

Band deviation

+/- 5 kHz Sinusoid wave 1 kHz

| ****


2

| ****


0.3

| ****


28

710| ****

704-787

| LTE bands 13, 17| Impulse modulation 217 Hz| ****

0.2

| ****

0.3

| ****

9

745
780
810| ****


800-

960

| GSM 800/900, TETRA 800,

iDEN 820,

CDMA 850,

LTE band 5

| ****

Impulse modulation 18 Hz

| ****


2

| ****


0.3

| ****


28

870


930

1720| ****


1700-

1990

| GSM 1800,

CDMA 1900,

GSM 1900, DECT, LTE

bands 1, 3,

4, 25, UMTS

| ****

Impulse modulation 217 Hz

| ****


2

| ****


0.3

| ****


28

1845


1970



2450

| ****


2400-

2570

| Bluetooth, WLAN 802.11

b/g/n, RFID 2450, band

LTE 7

| ****

Impulse modulation 217 Hz

| ****


2

| ****


0.3

| ****


28

5240| 5100-

5800

| WLAN

802.11 a/n

| Impulse modulation 217 Hz| ****

0.2

| ****

0.3

| ****

9

5500
5785

  • Manufacturer: Cofoe Medical Technology Co., Ltd.
    • 816 Zhenhua Road, Yuhua District 410000 Changsha, Hunan
  • PEOPLE’S REPUBLIC OF CHINA
    • SUNGO Europe B.V.
  • Olympisch Stadion 24, 1076DE Amsterdam
  • Importer: mPTech Ltd.
  • Nowogrodzka 31 street 00-511 Warsaw
    • Poland
  • Helpline: (+48 71) 71 77 400
    • Manufactured in China
  • Manual ready for print on: 2022.06

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

huslog User Manuals

Related Manuals