COUNTYLINE SFWI-750MW 30 Inch Wall Fan with Oscillation User Manual

June 4, 2024
COUNTYLINE

COUNTYLINE logo USER MANUAL AND OPERATING INSTRUCTIONS

COUNTYLINE SFWI 750MW 30 Inch Wall Fan with Oscillation
- 30 I N. WALL FAN WITH OSCILLATION
SKU NO.:1598573
MODEL NO.: SEWI-750MW

SFWI-750MW 30-Inch Wall Fan with Oscillation

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE USE
IMPORTANT READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY, SERVICE, OR USE OF THIS FAN. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY AND/OR PROPERTY DAMAGE.

COUNTYLINE SFWI 750MW 30 Inch Wall Fan with Oscillation -
1

PART DESCRIPTION QUANTITY
1 FRONT GUARD 1
2 REAR GUARD 1
3 BLADE 1
4 MOTOR 1
5 JOINT PLATE 1
6 WALL BRACKET 1
7 BOLT ST8*50 3
8 ANCHOR 910*60 3
9 BOLT M12*30 1
10 FLAT WASHER 912 2
11 SPRING WASHER 912 2
12 HEXANGULAR NUT M12 2
13 BOLT M8*30 1
14 TILT KNOB M8 1
15 ![COUNTYLINE SFWI 750MW 30 Inch Wall Fan with Oscillation -

icon9](https://manuals.plus/wp-content/uploads/2022/09/COUNTYLINE-SFWI- 750MW-30-Inch-Wall-Fan-with-Oscillation-icon9.png) BOLT M12120| 1
16| SCREW M3
10| 3
17| COUNTYLINE SFWI 750MW 30 Inch Wall Fan with Oscillation -
icon11 STAR WASHER 93| 6
18| HEXANGULAR NUT M3| 3

COUNTYLINE SFWI 750MW 30 Inch Wall Fan with Oscillation -
icon

SAFETY INFORMATION

WARNING:

  1. TIIS UNIT IS DESIGNED FOR INDOOR USE ONLY. DO NOT EXPOSE THEM TO ELEMENTS OR ALLOW THEM TO BECOME WET.
  2. TO GUARD AGAINST ELECTRIC SHOCK WHILE OPERATING, DO NOT ALLOW THE FAN TO COME IN CONTACT WITH OTHER GROUNDED OBJECTS SUCH AS PIPES, AND RADIATORS. ETC.
  3. TO REDUCE THE RISK OF ELECTRICAL SHOCK. 00 NOT USED WITH AND SOLID STATE SPED CONTROL DEVICE.
  4. DO NOT USE TO EXHAUST HAZARDOUS CHEMICALS OR USE NEAR ANY FLAMMABLE LIQUIDS OR GASES AS SPARKS FROM MOTOR MAY IGNITE FUMES.
  5. TURN OFF UNPLUG THE UNIT, AND WAIT FOR THE FAN TO STOP BEFORE MOVING. STORING.AND/OR CHANGING OPERATING LOCATIONS.
  6. D0 NOT INSERT YOUR HAND OR OTHER OBJECTS 1,1Th THE GUARD OR THE MOVABLE PARTS.
  7. BEFORE OPERATING ALWAYS CHECK THE FAN FOR LOOSE OR DAMAGED PARTS. NSPECT POWER CORD FOR ANY DAMAGE. NEVER USE A FAN IF ANY PARTS ARE DAMAGED OR MISSING. NEVER USE A FAN WITHOUT SAFETY GUARDS ATTACHED.
  8. WHEN USED WITH AN EXTENSION CORD, USE ONLY A CORD OF PROPER SIZE (AMP RATING), UL LISTED, AND WITH A RECEPTACLE TO ACCEPT THREE PRONG GROUNDED PLUG FURNISHED ON THE FAN’S POWER CORD. Always KEEP POWER CORD AND EXTENSION CORDS AWAY FROM HEAT, OIL. AND SHARP EDGES. INSPECT CORDS PERIODICALLY AND REPLACE THEM IF DAMAGED.
  9. DISCONNECT THE FAN FROM THE POWER SOURCE WHEN NOT IN USE. BEFORE SERVING AND WHEN CLEANING OR REPAIRING.
  10. REPAIR OF THIS APPLIANCE SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.
  11. IN CASE OF POWER FAILURE TURN THE FAN OFF AT THE POWER KNOB OR CHAIN TO PREVENT UNEXPECTED RESTARTING AND COMPONENT DAMAGE.
  12. KEEP CHILDREN AWAY FROM THE FAN AT ALL TIMES.
  13. DO NOT USE A HIGH-PRESSURE HOSE TO SPRAY THE FAN FOR CLEANING.
  14. DO NOT OPERATE ANY FAN WITH A DAMAGED CORD OR PLUG. DISCARD THE FAN OR RETURN IT TO AN AUTHORIZED SERVICE FACILITY FOR EXAMINATION AND/OR REPAIR.
  15. DO NOT RUN CORD UNDER CARPETING. DO NOT COVER THE CORD WITH THROW RUGS, RUNNERS, OR SIMILAR COVERINGS. DO NOT ROUTE CORD UNDER FURNITURE OR APPLIANCES. PLEASE ARRANGE THE CORD AWAY FROM THE TRAFFIC AREA AND WHERE IT WILL NOT BE TRIPPED OVER.

CAUTION:

  1. PRIOR TO CLEANING. UNPLUG THE FAN FROM THE SOCKET.
  2. D0 DO NOT IMMERSE THE FAN IN WATER.
  3. ENSURE THE GUARD IS SECURELY TIGHTENED ONTO THE FAN BEFORE USE.

CARE AND MAINTENANCE

UNPLUG THE APPLIANCE BEFORE CLEANING. SUBTLY MOISTEN A CLOTH AND THEN WIPE OFF THE SURFACES OF THE FAN. IN ORDER TO REMOVE THE DUST FROM THE PROTECTIVE GUARD, USE A VACUUM CLEANER OR REMOVE THE FRONT PROTECTIVE GUARD BY REMOVING THE SECURING SCREW ON THE EDGE OF THE GUARD WITH A SCREWDRIVER. AFTER CLEANING, REMOUNT THE SAFETY GUARD. AFTER DOING THIS, FASTEN THE SECURING SCREW ON THE EDGE OF THE PROTECTIVE GUARD.
SAVE THIS INSTRUCTION

ASSEMBLY INSTRUCTION

Step 1
MARK THE HOLE LOCATIONS BY USING THE WALL BRACKET, ANO THEN DRILLS HOLES.
a.FOR CONCRETE WALL INSTALLATION, AFTER DRILLING, INSERT THE ANCHORS ANO TAP THEM FLUSH WITH THE WALL POSITION THE WALL BRACKET ANO THEN SCREW THE THREE BOLTS ST8’50 INTO THE ANCHORS, SECURELY ATTACHING TO THE WALL
b. FOR WALL STUD INSTALLATION, AFTER DRUM THE SMALLER DIAMETER PILOT HOLE, POSITION THE WALL BRACKET ANO SCREW THE THREE BOLTS (pl 0460 INTO THE WALL UNTIL
THEY ARE SECURED.
WARNING:
IT MUST BE MOUNTED AND SECURED ON A SOLID WALL THAT IS STRUCTURALLY SOUND TO SUPPORT THE FAN AND MOUNTING BRACKET. THE WALL BRACKET ALONG WITH THE FAN MUST NOT BE MOUNTED ON ANY SURFACE THAT IS SUBJECT TO VIBRATION, WOBBLING MOVEMENT, OR THE LIKE. THE FAN MUST BE MOUNTED AND PROPERLY SECURED TO A STATIONARY STRUCTURE.
CAUTION: THE FAN IS ONLY SUITABLE FOR CONCRETE WALLS AND WALL STUDS. DO NOT USE IT FOR DRYWALL MOUNTING. USE THE MOUNTING ACCESSORIES SHIPPED WITH PRODUCTS FOR WALL MOUNTING.

REMOVE FOUR SETS OF HEXAGONAL NUTS, SPRING WASHERS, AND BOWL WASHERS FROM THE MOTOR. SAVE THEM FOR STEP 3.

SET REAR GUARD IN PROPER POSITION, AND FIX IT TO MOTOR BY SECURING BACK THE HEXAGONAL NUTS, SPRING WASHERS, AND BOWL   WASHERS FROM STEP 2.

ASSEMBLE FAN BLADE ONTO MOTOR SHAFT BY TIGHTENING TWO SCREWS FROM BLADE. MAKE SURE THE SCREWS ARE TIGHTLY SECURED.

ASSEMBLE FRONT GUARD TO REAR GUARD BY FIXING BOTH GUARDS TOGETHER WITH CLIPS ON THE RIM OF THE FRONT GUARD.

SECURE THE ASSEMBLY OF THE FRONT GUARD AND REAR GUARD BY TIGHTENING ONE SCREW M3*10, TWO START WASHER φ3, AND ONE HEXANGULAR NUT M3.

INSERT THE JOINT PLATE INTO THE MOTOR FRAME OF THE FAN HEAD BY FASTENING SCREWS AS FOLLOW:
FIRSTLY, NO.1 BOLT M1230 MATCH NO.7 FLAT WASHER φ12, NO.6
SPRING WASHER φ12, AND NO.5 HEXANGULAR NUT M12.
SECONDLY, NO.2 TILT KNOB M8 MATCHES NO.4 BOLT M8
30.

INSERT NO.1 BOLT M12*120 THROUGH THE JOINT PLATE, AND CONNECT THE WALL BRACKET. FASTEN THEM BY NO.2 FLAT WASHER φ12, NO.3
SPRING WASHER φ12, AND NO.4 HEXANGULAR NUT M12.

LOOSE TILT KNOB M8 FOR ADJUSTING THE DESIRED TILT ANGLE OF THE FAN HEAD, AND FIX IT AGAIN.
INSTALLATION — SECONDARY SAFETY SUPPORT CABLE
WARNING
THE USE OF SECONDARY SAFETY SUPPORT CABLE DOES NOT GUARANTEE PROTECTION AGAINST INJURY OF PERSONS. MOUNTING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL IF SUBJECT TO ABUSE, NEGLECT, OR IMPROPERLY INSTALLED. TO AVOID PERSONAL INJURY, CIRCULATORS MUST BE SUPPORTED ANYTIME THE ANGLE IS ADJUSTED.

PART DESCRIPTION QUANTITY
19 *** SAFETY CABLE 933050 1
20 CLAMP M5*13 2
21 *** BOLT ST850 1
22 WASHER 98 (p34 d 2 1
23 ANCHOR 910*60 1
  1. LOOP ONE END OF THE CABLE AROUND THE LARGE DIAMETER WIRES OF BOTH THE FRONT AND REAR GUARD AS SHOWN BELOW. ATTACH A CABLE RETAINER WITH THE “U” ON THE TAIL SIDE OF THE LOOP LEAVING A TAIL OF APPROXIMATELY 1 TO 2 INCHES. TIGHTEN CLAMP NUTS FORMING A TIGHT LOOP, 32IN. LBS OF TORQUE. MAKE SURE THE CABLE DOES NOT INTERFERE WITH THE PROPELLER.

  2. DRILL A HOLE IN THE CONCRETE WALL, INSERT THE WALL ANCHOR AND TAP IT FLUSH WITH THE WALL.

  3. TIGHTEN CLAMP NUTS FORMING A TIGHT SMALL LOOP ON THE TERMINAL OF THE SECONDARY SAFETY SUPPORT CABLE. FASTEN THE SMALL LOOP BY THE BOLT AND THE WASHER WILL BE FIXED INTO THE WALL THROUGH THE ANCHOR FOR SECURITY.

  4. CHECK THE ASSEMBLY TO ASSURE THE PROPELLER IS FREE OF ALL OBSTRUCTIONS AND TURNS FREELY.

  5. CONNECT THE CIRCULATOR TO THE PROPER POWER SUPPLY ENSURING THAT IT CONFORMS TO THE ELECTRICAL RATING LISTED ON THE CIRCULATOR’S MOTOR NAMEPLATE.

OPERATING INSTRUCTIONS

  1. ADJUST THE DESIRED SPEED BY PULLING THE CHAIN SWITCH WITH 3 SPEEDS CONTROL.
  2. TILT OR DOWN THE FAN HEAD FOR CHANGING AIR FLOW DIRECTION.

OPERATING INSTRUCTIONS

  1. 1.T0 MAKE THE FAN HEAD OSCILLATE: LOOSEN THE SCREW AND MOVE THE POSITION A. TIGHTEN IT BACK. NOTE: THE SCREW IS PRESET AT POSITION A AT THE FACTORY.
  2. T0 STOP THE FAN HEAD OSCILLATE: LOOSEN THE SCREW AND MOVE TO POSITION B.TIGHTEN IT BACK. CAUTION: SWITCH OFF THE FAN BEFORE ADJUSTING FAN HEAD OSCILLATION.

NOTE: FOR LONGER PARTS LIFE, AFTER 10 HOURS OF CONTINUOUS OPERATION, TURN THE FAN OFF FOR 15 MINUTES TO ALLOW THE MOTOR TO COOL

TROUBLESHOOTING GUIDE

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
THE FAN FAILS TO OPERATE 1. FAN MAY NOT BE PLUGGED IN. 1. MAKE SURE THE

FAN IS PLUGGED IN AND ELECTRICAL OUTLET IS WORKING PROPERLY.
2. THERE MAY SOME BE OBSTRUCTION IN THE FAN.| 2. CHECK FOR ANY OBSTRUCTION. IF YOU FIND AN OBSTRUCTION, TURN THE FAN “OFF”. UNPLUG THE FAN AND CAREFULLY REMOVE THE OBSTRUCTION. PLUG THE FAN IN AND TURN IT ON AGAIN, REFERRING TO THE OPERATION INSTRUCTIONS.

WARNING: IMMEDIATELY UNPLUG THE FAN IF ITS OPERATION IS FOUND TO BE UNBALANCED, WOBBLING OR SHOWING SIGNS OF SIGNIFICANT VIBRATION. DETERMINE THE ROOT CAUSE OF THE IMPROPER OPERATION (LOOSE MOUNTING HARDWARE, UNBALANCED PROPELLER, ETC) AND RESOLVE ACCORDINGLY. DO NOT OPERATE A FAN THAT IS NOT FUNCTIONING PROPERLY. TROUBLESHOOTING ANO PARTS REPLACEMENT MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL

TECHNICAL DATA

MODEL NO.| BLADE DIA. SIZE| VOL./ Hz| SPEED| INPUT POWER
---|---|---|---|---
SFWI-750MW| 30 IN./750MM| AC 120V /60 Hz| HIGH
MEDIUM
LOW| 240W
200W
185W
| ITEM NUMBER:| 5002308
---|---|---
DESCRIPTION:| 30in Industrial Pedestal Fan
INSTRUCTION MANUAL SIZE:| 630mm(M x 297mm(H)
COLOR:| IC+IC
| MATERIAL:| 80gsm Woodfree Paper
FINISHING:| NIL
DATE:| Dec 16, 2013
EROSION:| 1.7
RELEASED DATE:| Dec 19, 2013

Distributed by:
TRACTOR SUPPLY COMPANY
5401 VIRGINIA WAY,
BRENTWOOD, TN 37027
For customer support,
call: 1-888-376-9601
www.TractorSupply.com
MADE IN CHINA
30IN.WALL FAN WITH
OSCILLATION I FOR CUSTOMER SUPPORT,
CALL: 1-88B-376-9601 I
WWW.TRACTORSUPPLY.COM

Documents / Resources

| COUNTYLINE SFWI-750MW 30 Inch Wall Fan with Oscillation [pdf] User Manual
1598573, SFWI-750MW 30 Inch Wall Fan with Oscillation, SFWI-750MW, 30 Inch Wall Fan with Oscillation, 30 Inch Wall Fan, Wall Fan, Fan
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COUNTYLINE User Manuals

Related Manuals