FW MURPHY LP1084 M-VIEW J1939 Module Owner’s Manual

June 13, 2024
FW MURPHY

LP1084 M-VIEW J1939 Module
Owner’s Manual

FW MURPHY LP1084 M VIEW J1939 Module

M‐VIEW™ Series J1939 Module
Bulletin No. MVJ1939-A
Drawing No. LP1084
Effective 2018-11-30

FOR USE IN HAZARDOUS LOCATIONS: Class I, Division 2, Groups A, B, C, and D T4

  • CONFIGURED USING M-VIEW DESIGNER 3.1
  • DIGITALLY ISOLATED J1939 PORT CAPABLE OF COMMUNICATING WITH ANY J1939 DEVICE
  • POWERED AND CONFIGURED FROM M-VIEW HOST DEVICE
  • BUILT-IN TERMINATION RESISTOR SELECTABLE THROUGH A SWITCH

II 3 G Ex nA IIC T4 Gc
-40°C ≤ TAMB ≤ 75°C
DEMKO 14 ATEX 1387X
IECEx UL 15.0035X

GENERAL DESCRIPTION

The MV-J1939 is a J1939 communication module designed for use with CAN enabled devices using J1939 protocol. The module provides the M-VIEW a J1939 communications port. It is built with digital isolation to protect the M- VIEW from the J1939 bus and vice versa. It provides the ability to communicate to any J1939 device. The MV-J1939 module has a termination resistor built-in, and is selectable through a switch. The connector is pluggable for easy  removal of the MV-J1939 module from the J1939 bus, without disturbing communications with other devices on the bus.
The modules connect and communicate via proprietary USB connection to the various M-VIEW devices. The M-VIEW devices, equipped with serial ports as well as Ethernet port(s), allows the system to share data with PCs, PLCs and  SCADA systems. The maximum  number of modules varies for each M-VIEW device, see specific model for details. Remove power from the host device before installing or replacing any modules.

CONFIGURATION

The M-VIEW is configured with Windows® compatible M-VIEW DESIGNER 3.1 software. The software is an easy to use, graphical interface which provides a means of configuration and commissioning of new systems, as well as  routine module re-calibration.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the unit.

 Read complete instructions prior to installation and operation of the unit.
  WARNING  – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON-HAZARDOUS.
  WARNING  – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.

ORDERING INFORMATION

DESCRIPTION PART NUMBER
M-VIEW Module, J1939 Protocol Interface 50704942

A listing of the entire M-VIEW family of products and accessories can be found at www.fwmurphy.com.

SPECIFICATIONS

  1. POWER: Power will be supplied by the M-VIEW host device. Some modules, depending on usage may consume high levels of power. This may limit the total number of modules that can be installed on a single M-VIEW host.  Check the M-VIEW module and M-VIEW host data sheets for specific usage and power requirements. MV-J1939 Max Power: 1.2 W

  2. COMMUNICATIONS:
    J1939 Port: The J1939 port has format and baud rates that are software programmable up to 250K baud and is digitally isolated. 124 ohm, 1W termination is provided through a switch. This port may be configured for various  J1939 protocols. Isolation from MV-J1939 Communication ports to M-VIEW host device: 1000 VDC for 1 minute.

  3. ENVIRONMENTAL CONDITIONS:
    Operating Temperature Range: -40 to 75 °C, or lowest range among equipment used in your M-VIEW system. Consult the user manual for further details. Storage Temperature Range: -40 to +85 °C Operating and Storage  Humidity: 85% max. relative humidity, noncondensing. Altitude: Up to 2000 meters

  4. CERTIFICATIONS AND COMPLIANCES:
    CE Approved
    EN 61326-1 Immunity to Industrial Locations
    IEC/EN 61010-1
    RoHS Compliant
    ATEX Approved
    II 3 G Ex nA IIC T4 Gc
    DEMKO 14 ATEX 1387X
    EN 60079-0, -15
    IECEx Approved
    Ex nA IIC T4 Gc
    IECEx UL 15.0035X
    IEC 60079-0, -15
    UL Listed: File #E302106
    UL Hazardous: File #E317425
    ABS Type Approval for Shipboard Applications

  5. CONSTRUCTION: Case body is all metal construction.

  6. CONNECTIONS: Removable wire clamp screw terminal blocks
    Wire Gage: 28-14 AWG (0.32 mm – 1.63 mm) terminal gage wire Torque: 1.95-2.21 inch-lbs (0.22-0.25 N-m)

  7. MOUNTING: Screws to host

  8. WEIGHT: 6.9 oz (196 g)

Block Diagram for MV-J1939

EMC INSTALLATION GUIDELINES
Although FW Murphy products are designed with a high degree of immunity to Electromagnetic Interference (EMI), proper installation and wiring methods must be followed to ensure compatibility in each application. The type of the electrical noise, source or coupling method into a unit may be different for various installations. Cable length, routing, and shield termination are very important and can mean the difference between a successful or troublesome installation. Listed are some EMI guidelines for a successful installation in an industrial environment.

  1. A unit should be mounted in a metal enclosure, which is properly connected to protective earth.

  2. Use shielded cables for all Signal and Control inputs. The shield connection should be made as short as possible. The connection point for the shield depends somewhat upon the application. Listed below are the recommended  methods of connecting the shield, in order of their effectiveness.
    a. Connect the shield to earth ground (protective earth) at one end where the unit is mounted.
    b. Connect the shield to earth ground at both ends of the cable, usually when the noise source frequency is over 1 MHz

  3. Never run Signal or Control cables in the same conduit or raceway with AC power lines, conductors, feeding motors, solenoids, SCR controls, and heaters, etc. The cables should be run through metal conduit that is properly  grounded. This is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. Also, Signal or Control cables within  an enclosure should be routed as far away as possible from contactors, control relays, transformers, and other noisy components.

  4. Long cable runs are more susceptible to EMI pickup than short cable runs.

  5. In extremely high EMI environments, the use of external EMI suppression devices such as Ferrite Suppression Cores for signal and control cables is effective. Contact FW Murphy Technical Support for recommendation for your application.

  6. To protect relay contacts that control inductive loads and to minimize radiated and conducted noise (EMI), some type of contact protection network is normally installed across the load, the contacts or both. The most effective location is across the load.
    a. Using a snubber, which is a resistor-capacitor (RC) network or metal oxide varactor (MOV) across an AC inductive load is very effective at reducing EMI and increasing relay contact life.
    b. If a DC inductive load (such as a DC relay coil) is controlled by a transistor switch, care must be taken not to exceed the breakdown voltage of the transistor when the load is switched. One of the most effective ways is to place a  diode across the inductive load. Most FW Murphy products with solid state outputs have internal Zener diode protection. However external diode protection at the load is always a good design practice to limit EMI. Although the  use of a snubber or varactor could be used.

  7. Care should be taken when connecting input and output devices to the instrument. When a separate input and output common is provided, they should not be mixed. Therefore a sensor common should NOT be connected to an  output common. This would cause EMI on the sensitive input common, which could affect the instrument’s operation.

HARDWARE INSTALLATION
The physical order of all installed modules must match the modules order in M-VIEW DESIGNER 3.1. Torque screws to 6.0 pound-force inch [96 ounce-force inch] (0.68 Nm).
WARNING: Disconnect all power to the unit before installing or removing modules.

COMMUNICATING WITH THE MV‐J1939 MODULE

CONFIGURATION
Programming is done via M-VIEW™ DESIGNER 3.1 software, a Windows ® compatible configuration interface. Please see the M-VIEW DESIGNER 3.1 User Manual for more information.
J1939 PORT PROTOCOLS
The MV-J1939 module has one J1939 port. WARNING – EXPLOSION HAZARD – DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.

TERMINATION RESISTOR

An onboard termination resistor is selectable through a switch. The termination resistor is rated for 124Ω at 1W. If a different termination resistance is desired, slide the switch for no termination resistor. At this point you will be  required to connect your own termination resistor between positions 2 and 4 of the five position connector. FW MURPHY LP1084 M VIEW
J1939 Module - RESISTOR

CAN GND
Position 1 of the pluggable connector provides a CAN ground connection. This terminal is isolated from the M-VIEW host device.
CAN‐
Position 2 of the pluggable connector provides the CAN- bus line (active low). This terminal is isolated from the M-VIEW host device.
SHLD (CAN SHIELD)
Position 3 of the pluggable connector is provided for shield connections. This position is available to tie shield wires to earth ground. The SHLD position is connected through a series RC network to CHASSIS as noted in specification J1939-11. The SHLD connection is internally tied to the M-VIEW host device enclosure
CAN+
Position 4 of the pluggable connector provides the CAN+ bus line (active high). This terminal is isolated from the M-VIEW host device.
V+ (OPTIONAL 24 VDC)
Position 5 of the pluggable connector is provided for optional 24 VDC connections. This position is available only to tie 24 VDC wires together. The MV-J1939 module neither provides 24 VDC power nor uses 24 VDC power through this  connection. The V+ position is not connected to any circuitry internal to the MV-J1939 module or M-VIEW Host device.
LEDs
STS – STATUS LED
The Status LED is a green/red LED that provides information regarding the state of the module. This includes indication of the various stages of the start-up routine (power-up), as well as any errors that may occur. Startup Routine

Flashing Red| Module is currently running the boot loader and/or
being flash upgraded by M-VIEW DESIGNER 3.1.
---|---
Green| Module performing normally.

Error States

Flashing Green Module has lost communication with the Host.

RUN/ERROR LED

Green| MV-J1939 module established communication with other J1939 devices (RUN) and is communicating normally.
---|---
Red| MV-J1939 module failed to establish communications with other J1939 devices (ERROR).

FIRMWARE UPGRADE
The module’s firmware is stored in flash memory so that software/ hardware conflicts are avoided, and so features can be added in the future.
During a download, M-VIEW DESIGNER 3.1 compares its own library of firmware files with those stored in the module. If they do not match, MVIEW DESIGNER 3.1 will download the necessary firmware.
M‐VIEW TROUBLESHOOTING
If for any reason you have trouble operating, connecting, or simply have questions concerning your new M-VIEW unit, contact FW Murphy’s technical support.
Warranty – A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of this warranty may be viewed or printed by going to http://www.fwmurphy.com/warranty

FW MURPHY PRODUCTION CONTROLS| DOMESTIC SALES & SUPPORT| INTERNATIONAL SALES & SUPPORT
---|---|---
 SALES, SERVICES & ACCOUNTING 4646 S. HARVARD AVE. TULSA, OK 74135
CONTROL SYSTEMS & SERVICES 105 RANDON DYER ROAD ROSENBERG, TX 77471
MANUFACTURING 5757 FARINON DRIVE SAN ANTONIO, TX 78249|  FW MURPHY PRODUCTS PHONE: 918 957 1000
EMAIL: [email protected] WWW.FWMURPHY.COM FW MURPHY CONTROL SYSTEMS & SERVICES PHONE: 281 633 4500 EMAIL: CSS-[email protected]| CHINA PHONE: +86 511 8788 6060
EMAIL: [email protected]
LATIN AMERICA & CARIBBEAN
PHONE: +1 918 957 1000
EMAIL: [email protected]
SOUTH KOREA
PHONE: +82 70 7951 4100
EMAIL: [email protected]

FM 668576 (San Antonio, TX – USA)
FM 668933 (Rosenberg, TX – USA)FW MURPHY LP1084 M VIEW J1939 Module - icon
1FM 523851 (China) TS 589322 (China)
Phone: 918-957-1000
Email: t[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FW MURPHY User Manuals

Related Manuals