XTREME P91 5-10kVA Online UPS
Product Information
Product Model | Description |
---|---|
P91 with XBDM-P91A | 5-10kVA UPS with Bypass, approved for installation with |
XBDM-P91A
P91 with XBDM-P91B| 5-10kVA UPS with Bypass, approved for installation with
XBDM-P91B
P91 with XBDM-P91C| 5-10kVA UPS with Bypass, approved for installation with
XBDM-P91C
Product Usage Instructions
To install the P91 UPS with XBDM-P91A: P91 with XBDM-P91A
- Ensure the input and output wiring between the UPS and Bypass are supplied with the bypass.
- Connect the red connector to the UPS input and the black connector to the UPS output. Note that for the black set of wiring, the red wire is L1 and the black wire is L2(N). For the red set, the brown wire is L1 and the blue wire is L2(N).
- Use the provided brackets to install the XBDM to a rack or to mount it to the back of an external battery pack.
- Load connections can be made from the bypass.
To install the P91 UPS with XBDM-P91B:
- Ensure the input and output wiring between the UPS and Bypass are supplied with the bypass.
- Connect the red connector to the UPS input and the black connector to the UPS output. Note that for the black set of wiring, the red wire is L1 and the black wire is L2(N). For the red set, the brown wire is L1 and the blue wire is L2(N).
- Use the provided brackets to install the XBDM to a rack or to mount it to the back of an external battery pack.
- Load connections can be made from the bypass.
To install the P91 UPS with XBDM-P91C:
- Ensure the input and output wiring between the UPS and Bypass are supplied with the bypass.
- Connect the red connector to the UPS input and the black connector to the UPS output. Note that for the black set of wiring, the red wire is L1 and the black wire is L2(N). For the red set, the brown wire is L1 and the blue wire is L2(N).
- Use the provided brackets to install the XBDM to a rack or to mount it to the back of an external battery pack.
- Load connections can be made from the bypass.
P91 5-10k with Bypass
P91 with XBDM-P91A
Notes:
- Input and output wiring between UPS and Bypass are supplied with bypass.
- Red connector is for UPS input, black for UPS output. Note that for the black set of wiring that the red wire is L1 and black wire is L2(N).
- For red set the brown wire is L1 and blue wire is L2(N).
- XBDM comes with brackets for installation to rack or to mount it to back of an external battery pack.
- Load connections can be made from the bypass
P91 with XBDM-P91B
P91 with XBDM-P91C
P91 with XBDM-P91D
P91 5-10k with Output Transformer
P91 with XPD-IT6kW
P91 with XPD-IT10kW
P91 with Bypass and Transformer
P91 with XBDM-P91A and XPD-IT60A
P91 with XBDM-P91B and XPD-IT60A
P91 with XBDM-P91C and XPD-IT60A
P91 with XBDM-P91D and XPD-IT60A
P91 with XBDM-P91B and XPD-IT6kW
P91 with XBDM-P91C and XPD-IT6kW
P91 with XBDM-P91B and XPD-IT10kW
P91 with XBDM-P91C and XPD-IT10kW
www.xpcc.com
© 2022 Xtreme Power Conversion Corporation. All rights reserved. (Rev
10/14/22)
Documents / Resources
|
XTREME P91 5-10kVA Online
UPS
[pdf] Installation Guide
P91 5-10kVA Online UPS, P91 5-10kVA, Online UPS, UPS
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>