TRT Series Electric Sauna Heater
The overheat protector of the device can go off also at temperatures below
-5˚C / 23˚F (storage, transport, environment). Before installation takes the
device to a warm environment. The overheat protector can be reset when the
temperature of the device is approx 18˚C / 64˚F.
The overheat protector must be reset before using the device. See the user
manual > Resetting the Overheat Protector.
These instructions for installation and use are intended for the owner or the
person in charge of the sauna, as well as for the electrician in charge of the
electrical installation of the heater. After completing the installation, the
person in charge of the installation should give these instructions to the
owner of the sauna or to the person in charge of its operation. Please read
the instructions for use carefully before using the heater.
The heater is designed for the heating of a sauna room to a bathing
temperature. It is not to be used for any other purpose.
Congratulations on your choice!
Guarantee:
- The guarantee period for heaters and control equipment used in saunas by families is two (2) years.
- The guarantee period for heaters and control equipment used in saunas by building residents is one (1) year.
- The guarantee does not cover any faults resulting from failure to comply with installation, use, or maintenance instructions.
- The guarantee does not cover any faults resulting from the use of stones not recommended by the heater manufacturer.
INSTRUCTIONS FOR USE
1.1. Piling of the Sauna Stones
The piling of the sauna stones has a great effect on both the safety and the
heating capability of the heater.
Important information on sauna stones:
-
The stones should be 5–10 cm in diameter.
-
Use solely angular split-face sauna stones that are intended for use in a heater. Peridotite, olivine-dolerite, and olivine are suitable stone types.
-
Neither light, porous ceramic “stones“ nor soft soapstones should be used in the heater. They do not absorb enough heat when warmed up.
This can result in damage in heating elements. -
Wash off the dust from the stones before piling them into the heater.
Please note when placing the stones:
- The aim is to pile a dense layer of stones against the steel grid and pile the rest of the stones loosely. The dense layer prevents direct heat radiation from overheating materials around the heater. Be especially careful with the corners where the heating elements are near the grid. The loose piling of stones in the middle lets the airflow through the heater, resulting in good heating of the sauna and sauna stones.
- Do not drop stones into the heater.
- Do not wedge stones between the heating elements.
- Pile the stones so that they support each other instead of lying their weight on the heating elements.
- Support the heating elements with stones so that the elements stay vertically straight.
- Do not form a high pile of stones on top of the heater.
- No such objects or devices should be placed inside the heater stone space or near the heater
that could change the amount or direction of the air flowing through the
heater.
**** A bare heating element can endanger combustible materials even outside
the safety distances. Check that no heating elements can be seen behind the
stones.
1.1.1. Maintenance
Due to large variations in temperature, the sauna stones disintegrate in use.
Rearrange the stones at least once a year or even more often if the sauna is
in frequent use. At the same time, remove any pieces of stones from the bottom
of the heater and replace any disintegrated stones with new ones. By doing
this, the heating capability of the heater stays optimal and the risk of
overheating is avoided.
**** Pay attention, especially to the gradual settling of the stones. Be sure
that the heating elements do not appear with time. The stones settle most
rapidly within two months of piling.
1.2. Heating of the Sauna
When operating the heater for the first time, both the heater and the stones
emit a smell. To remove the smell, the sauna room needs to be efficiently
ventilated.
If the heater output is suitable for the sauna room, it will take about an
hour for a properly insulated sauna to reach the required bathing temperature
( 2.3.). The sauna stones normally reach the bathing temperature at the same
time as the sauna room.
A suitable temperature for the sauna room is about 65–75 °C.
1.3. Using the Heater
Before switching the heater on always check that there isn’t anything on top
of the heater or inside the given safety distance. 1.6.
-
Heater models TRT70 and TRT90 are equipped with a timer and a thermostat. The timer is for setting the on-time for the heater and the thermostat is for setting a suitable temperature.
1.3.1.–1.3.4. -
Heater models TRT70E and TRT90E are controlled from a separate control unit. See the instructions for use of the selected control unit model.
1.3.1. Heater On
Turn the timer switch to the ”on” section (section A in figure 2, 0–4 hours).
The heater starts heating immediately.
1.3.2. Pre-setting Time (timed switch-on)
Turn the timer switch to the ”pre-setting” section (section B in figure 2, 0–8
hours).
The heater starts heating when the timer has turned the switch back to the
”on” section. After this, the heater will be on for about four hours.
Example: You want to go walking for three hours and have a sauna bath after
that. Turn the timer switch to the “pre-setting” section at number 2.
The timer starts. After two hours, the heater starts heating. Because it takes
about one hour for the sauna to be heated, it will be ready for bathing after
about three hours, that is, when you come back from your walk.
1.3.3. Heater Off
The heater switches off when the timer turns the switch back to zero. You can
switch the heater off at any time by turning the timer switch to zero
yourself.
Switch the heater off after bathing. Sometimes it may be advisable to leave
the heater on for a while to let the wooden parts of the sauna dry properly.
**** Always check that the heater has switched off and stopped heating after
the timer has turned the switch to zero.
1.3.4. Setting the Temperature
The purpose of the thermostat (figure 3) is to keep the temperature in the
sauna room at the desired level. By experimenting, you can find the setting
that suits you best.
Begin experimenting at the maximum position. If, during bathing, the
temperature rises too high, turn the switch counter-clockwise a little. Note
that even a small difference within the maximum section will change the
temperature of the sauna considerably.
1.4. Throwing Water on Heated Stones
The air in the sauna room becomes dry when warmed up. Therefore, it is
necessary to throw water on the heated stones to reach a suitable level of
humidity in the sauna. The effect of heat and steam on people varies – by
experimenting, you can find the levels of temperature and humidity that suit
you best.
You can adjust the nature of the heat from soft to sharp by throwing water
either to the front of the heater or straight on top of the stones.
**** The maximum volume of the ladle is 0.2 liters.
If an excessive amount of water is poured on the stones, only part of it will
evaporate and the rest may splash as boiling hot water on the bathers. Never
throw water on the stones when there are people near the heater, because hot
steam may burn their skin.
The water to be thrown on the heated stones should meet the requirements of
clean household water (table 1). Only special aromas designed for sauna water
may be used. Follow the instructions given on the package.
1.5. Instructions for Bathing
- Begin by washing yourself.
- Stay in the sauna for as long as you feel comfortable.
- Forget all your troubles and relax.
- According to established sauna conventions, you must not disturb other bathers by speaking in a loud voice.
- Do not force other bathers from the sauna by throwing excessive amounts of water on the stones.
- Cool your skin down as necessary. If you are in good health, you can have a swim if a swimming place or pool is available.
- Wash after bathing.
- Rest for a while and let your pulse go back to normal. Have a drink of fresh water or a soft drink to bring your fluid balance back to normal.
Table 1. Water quality requirements
Water properties | Effect | Recommendation |
---|---|---|
Humus concentration | Colour, taste, precipitates | <12 mg/I |
Iron concentration | Colour, odor, taste, precipitates | <0,2 mg/I |
Manganese (Mn) | Colour, odor, taste, precipitates | <0,10 mg/I |
Hardness: most important substances are magnesium (Mg) and lime, i.e. calcium
(Ca)| Precipitates| Mg: <100 mg/I
Chloride-containing water| Corrosion| CI: <100 mg/I
Chlorinated water| Health risk| Forbidden to use
Seawater| Rapid corrosion Rasche Korrosion| Forbidden to use
Arsenic and radon concentration| Health risk| Forbidden to use
1.6. Warnings
- Staying in the hot sauna for long periods of time makes the body temperature rise, which may be dangerous.
- Keep away from the heater when it is hot. The stones and outer surface of the heater may burn your skin.
- Keep children away from the heater.
- Do not let young, handicapped, or ill people bathe in the sauna on their own.
- Consult your doctor about any health-related limitations to bathing.
- Consult your child welfare clinic about taking little babies to the sauna.
- Be very careful when moving in the sauna, as the platform and floors may be slippery.
- Never go to a hot sauna if you have taken alcohol, strong medicines, or narcotics.
- Never sleep in a hot sauna.
- Sea air and a humid climate may corrode the metal surfaces of the heater.
- Do not hang clothes to dry in the sauna, as this may cause a risk of fire. Excessive moisture content may also cause damage to the electrical equipment.
1.6.1. Symbols descriptions
**** Read the operator’s manual.
Do not cover.
1.7. Troubleshooting
All service operations must be done by professional maintenance personnel.
The heater does not heat.
- Check that the fuses to the heater are in good condition.
- Check that the connection cable is connected ( 3.4.).
- TRT70/TRT90: Turn the timer switch to the “on” section ( 1.3.1.).
- Turn the thermostat to a higher setting ( 1.3.4.).
- TRT70/TRT90: Check that the overheat protector has not gone off. The timer works but the heater does not heat. ( 3.5.)
- TRT90: Check the functioning of the contactor.
A “click” should be heard from the contactor when you turn the timer switch to the “on” section ( 1.3.1.).
The sauna room heats slowly. The water thrown on the sauna stones cools down the stones quickly.
- Check that the fuses to the heater are in good condition.
- Check that all heating elements glow when the heater is on.
- Turn the thermostat to a higher setting ( 1.3.4.).
- Check that the heater output is sufficient ( 2.3.).
- Check the sauna stones ( 1.1.). Too tightly piled stones, the settling of stones with time, or the wrong stone type can hinder the airflow through the heater, which results in reduced heating efficiency.
- Check that the sauna room ventilation has been arranged correctly ( 2.2.).
The sauna room heats quickly, but the temperature of the stones remains
insufficient.
Water thrown on the stones runs through.
- Turn the thermostat to a lower setting ( 1.3.4.).
- Check that the heater output is not too high ( 2.3.).
- Check that the sauna room ventilation has been arranged correctly ( 2.2.).
Panel or other material near the heater blackens quickly.
- Check that the requirements for safety distances are fulfilled ( 3.1.).
- Check the sauna stones ( 1.1.). Too tightly piled stones, the settling of stones with time, or the wrong stone type can hinder the airflow through the heater, which may result in overheating of surrounding materials.
- Check that no heating elements can be seen behind the stones. If heating elements can be seen, rearrange the stones so that the heating elements are covered completely ( 1.1.).
- Also, see section 2.1.1.
The heater emits a smell.
- See section 1.2.
- The hot heater may emphasize odors mixed in the air that are not, however, caused by the sauna or the heater. Examples: paint, glue, oil, seasoning.
The heater makes a noise.
- TRT70/TRT90: The timer is a mechanical device and it makes a ticking sound when it is functioning normally. If the timer ticks even when the heater is switched off, check the timer’s wiring.
- Occasional bangs are most likely caused by stones cracking due to heat.
- The thermal expansion of heater parts can cause noises when the heater warms up.
SAUNA ROOM
2.1. Sauna Room Structure
A. Insulation wool, thickness 50–100 mm. The sauna room must be insulated carefully so that the heater output can be kept moderately low.
B. Moisture protection, e.g. aluminum paper.
Place the glossy side of the paper towards the sauna. Tape the seams with aluminum tape.
C. Vent gap of about 10 mm between the moisture protection and panel (recommendation).
D. Low mass 12–16 mm thick panel board. Before starting the paneling, check the electric wiring and the reinforcements in the walls required by the heater and benches.
E. Vent gap of about 3 mm between the wall and ceiling panel.
F. The height of the sauna is usually 2100–2300 mm.
The minimum height depends on the heater (see table 2). The space between the upper bench and ceiling should not exceed 1200 mm.
G. Use floor coverings made of ceramic materials and dark joint grouts. Particles disintegrating from the sauna stones and impurities in the sauna water may stain and/or damage sensitive floor coverings.
NOTE! Check with the fire authorities which parts of the firewall can be insulated. Flues that are in use must not be insulated.
NOTE! Light protective covers which are installed directly to the wall or ceiling may be a fire risk.
2.1.1. Blackening of the Sauna Walls
It is perfectly normal for the wooden surfaces of the sauna room to blacken in
time. The blackening may be accelerated by
- sunlight
- heat from the heater
- protective agents on the walls (protective agents have a poor heat resistance level)
- fine particles disintegrate from the sauna stones which rise with the airflow.
2.2. Sauna Room Ventilation
The air in the sauna room should change six times per hour. Figure 5 illustrates different sauna room ventilation options.
A. Supply air vent location. If mechanical exhaust ventilation is used, place
the supply air vent above the heater. If gravity exhaust ventilation is used,
place the supply air vent below or next to the heater. The diameter of the
supply air pipe must be 50–100 mm. TRT-E: Do not place the supply air vent so
that the airflow cools the temperature sensor (see the temperature sensor
installation instructions in the control unit installation instructions)!
B. Exhaust air vent. Place the exhaust air vent near the floor, as far away
from the heater as possible. The diameter of the exhaust air pipe should be
twice the diameter of the supply air pipe.
C. Optional vent for drying (closed during heating and bathing). The sauna can
also be dried by leaving the door open after bathing.
D. If the exhaust air vent is in the washroom, the gap underneath the sauna
door must be at least 100 mm. Mechanical exhaust ventilation is mandatory.
2.3. Heater Output
When the walls and ceiling are covered with panels and the insulation behind
the panels is adequate, the heater output is defined according to the volume
of the sauna. Non-insulated walls (brick, glass block, glass, concrete, tile,
etc.) increase the need for heater output. Add 1,2 m³ to the volume of the
sauna for each non-insulated wall square meter. Forexample, a 10 m³ sauna room
with a glass door equals the output requirement of about a 12 m³sauna room. If
the sauna room has log walls, multiply the sauna’s volume by 1,5. Choose the
correct heater output from Table 2.
2.4. Sauna Room Hygiene
Bench towels should be used during bathing to prevent sweat from getting onto
the benches.
The benches, walls, and floor of the sauna should be washed thoroughly at
least every six months.
Use a scrubbing brush and sauna detergent.
Wipe dust and dirt from the heater with a damp cloth. Remove lime stains from
the heater using a 10% citric acid solution and rinse.
INSTRUCTIONS FOR INSTALLATION
3.1. Before Installation
Before installing the heater, study the instructions for installation. Check
the following points:
- Is the output and type of the heater suitable for the sauna room? The cubic volumes given in table 2 should be followed.
- Is the supply voltage suitable for the heater?
- The location is suitable for the heater ( 3.2.).
- 3.5. Resetting the Overheat Protector
Note! Only one electrical heater may be installed in the sauna room.
Heater
Ofen| Output| Dimensions| Stones| Sauna room
---|---|---|---|---
Width/Depth/Height| Weight| max. kg| Cubic vol.|
Height
| kW| mm| kg| 80| 2.3.!
min. m³| max. m³| min. mm
TRT70| 6,8| 364/364/1076| 14| 80| 6| 10| 1900
TRT70E| 6,8| 364/364/1076| 13| 90| 6| 10| 1900
TRT90| 9,0| 364/364/1076| 15| 90| 8| 14| 1900
TRT90E| 9,0| 364/364/1076| 14| | 8| 14| 1900
Table 2. Installation details of the heater
3.2. Place and Safety Distances
The minimum safety distances are described in figure 6.
- It is absolutely necessary to install the heater according to these values. Neglecting them causes a risk of fire.
- Hot pieces of stone can damage floor coverings and cause a risk of fire. The floor coverings of the installation place should be heat-resistant.
- If the heater is to be embedded into the bench using the embedding flange HPC1 or HPC2, see installation instructions of the flange before making a hole in the bench.
3.3. Electrical Connections
**** The heater may only be connected to the electrical network in accordance
with the current regulations by an authorized, professional electrician.
-
The heater is semi-stationarily connected to the junction box (figure 7: A) on the sauna wall.
The junction box must be splash-proof, and its maximum height from the floor must not exceed 500 mm. -
The connecting cable (figure 7: B) must be of rubber cable type H07RN-F or its equivalent.
NOTE! Due to thermal embrittlement, the use of PVC-insulated wire as the connecting cable of the heater is forbidden.
- If the connecting and installation cables are higher than 1 000 mm from the floor in the sauna or inside the sauna room walls, they must be able to endure a minimum temperature of 170 °C when loaded (for example, SSJ). Electrical equipment installed higher than 1 000 mm from the sauna floor must be approved for use at a temperature of 125 °C (marking T125).
- In addition to supply connectors, the TRT70 and TRT90 heaters are equipped with a connector (P), which makes the control of the electric heating possible (figure 7). Voltage control is transmitted from the heater when it is switched on. The control cable for electrical heating is brought directly into the junction box of the heater, and from there to the terminal block of the heater along a rubber cable with the same cross-section area as that of the connecting cable.
3.3.1. Electric Heater Insulation Resistance
When performing the final inspection of the electrical installations, a
“leakage” may be detected when measuring the heater’s insulation resistance.
The reason for this is that the insulating material of the heating elements
has absorbed moisture from the air (storage, transport). After operating the
heater a few times, the moisture will be removed from
the heating elements.
Do not connect the power feed for the heater through the RCD (residual current device)!
3.3.2. Installation of the Control Unit and Sensor (TRT70E, TRT90E)
- The control unit includes detailed instructions for fastening the unit on the wall.
- Install the sensor (WX248) as shown in figure 8. If the heater is installed further than 100 mm from the wall, the sensor must be installed on the ceiling.
**** Do not place the supply air vent so that the airflow cools the temperature sensor. Figure 5.
3.4. Installing the Heater
See figure 9.
- Connect cables to the heater ( 3.3.).
- Place the heater and adjust the heater vertically straight using the adjustable legs.
- Use fixing kits (2 pcs) to fix the heater to the sauna’s structures.
3.5. Resetting the Overheat Protector
If the temperature of the sauna room becomes dangerously high, the overheat
protector will permanently cut off the supply of the heater. The overheating
protector can be reset after the heater has cooled down.
TRT70E/TRT90E
See the installation instructions for the control unit.
TRT70/TRT90
The location of the reset button has been marked in the heater’s type label.
The overheating protector can be reset by pressing through the label with a
screwdriver (Figure 10). Only persons authorized to carry out electrical
installations can reset the overheat protector.
Prior to pressing the button, the cause of the fault must be found.
- Are the stones crumbled and pressed together?
- Has the heater been on for a long time while unused?
- Is the sensor of the thermostat out of place or broken?
- Has the heater been banged or shaken?
****The overheat protector of the device can go off also at temperatures below -5˚C / 23˚F (storage, transport, environment). Before installation takes the device to a warm environment. The overheat protector can be reset when the temperature of the device is approx 18˚C / 64˚F. The overheat protector must be reset before using the device.
SPARE PARTS
We recommend using only the manufacturer’s spare parts.
P.O.Box 12
Teollisuustie 1-7
40951 Muurame FINLAND
+358 207 464 000
harvia@harvia.fi
www.harvia.fi
Адрес уполномоченного лица:
ООО «Харвия Рус»
196006, Россия.Санкт-Петербург г,
пр-кт Лиговский, д. 266, стр.
1, помещ. 2.1-Н.50
ОГРН 1157847200818
т: +78123258294
spb@accountor.ru
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>