Product Information
Product Name | Presence Detector |
---|---|
Model Number | 353-751421-1 |
Mounting Type | SnapFit |
Installation Type | Fixed Ceiling or Suspended Ceiling |
Wiring Type | Fixed Ceiling: 9.5 – 40 mm or 0.2 – 9 mm |
Suspended Ceiling: 9.5 – 40 mm or 0.2 – 9 mm
App Settings| Factory Settings: Switch ON/OFF, 500 lux, 15 min
LED Behavior| Green LED continuous on, Green LED breathing, Green LED
flashing, Red LED continuous on, Red LED breathing, Blue LED
flashing
Product Usage Instructions
To install the presence detector, follow these steps:
- Determine the appropriate mounting type based on your ceiling type: fixed ceiling or suspended ceiling.
- If you have a fixed ceiling, ensure the wiring is correctly connected within the specified range of 9.5 – 40 mm or 0.2 – 9 mm.
- If you have a suspended ceiling, ensure the wiring is correctly connected within the specified range of 9.5 – 40 mm or 0.2 – 9 mm.
- Once the wiring is properly installed, use the detector tool to check the connection status. The green LED should indicate a successful connection.
- Configure the app settings according to your preferences. The factory settings include switch ON/OFF, 500 lux, and a 15-minute switch-off delay.
- Observe the LED behavior for status indications. The presence detector has different LED patterns for different states, such as connection OK, warming up, error, warning, and walk test active.
If you encounter any issues with the presence detector, refer to the troubleshooting guide:
Problem | Possible Cause | Proposed Solution |
---|---|---|
Load does not turn on | The wiring is not correct | Check the wiring scheme |
Load does not turn off | The ambient light is too strong or the switch-off |
delay is too
long| Check the response value luminosity and raise the value if
necessary
Check the switch-off delay and shorten the delay if necessary
The app cannot connect to the detector| The wiring is not correct or the
detector receives false
triggers| Check the wiring scheme
Check for any objects that may cause false triggering and remove
them from the detection range or lower the sensitivity
Presence detector P48LR, DALI-2, master, 32-37 m, 360°, SnapFit, for flush mounting, WAGO WINSTA® MIDI 2 m cable with 5-pol. connector
Wiring
- WAGO WINSTA® mounting plate, 770-625
- WAGO WINSTA® distribution connector, 770-618
Dimensions
Installation
App settings
__ | __ | __ | |
---|---|---|---|
Factory settings | Switch ON/OFF | 500 lux | 15 min |
LED behaviour
Specifications
- Article number………………………………………………………………………………………. 353-751421-1
- Configuration…………………………………………………………………………………………..DALI-2 master
- Input voltage……………………………………………………………………………….230 Vac ± 10 %, 50 Hz
- Maximum power consumption……………………………………………………………………………. 0.6 W
- Maximum power consumption wireless link active…………………………………………….. 0.65 W
- Short circuit behaviour shutdown trigger……………………… voltage below 12 V, exceeding 1.3 s
- Short circuit behaviour restart period………………………………………….. every 14 s until success
- Detector output……………………………………………………………….. DALI Broadcast/DALI Adressable
- Circuit breaker……………………………………………………………………….maximum MCB rating 16 A*
- Relay contact…………………………………………………………………… NO (max. μ10 A), potential-free
- Maximum load incandescent and halogen lamps (cosφ = 1)…………………………………. 2300 W
- Maximum load fluorescent lamps (cosφ ≥ 0.5)……………………………………………………. 1200 VA
- Maximum load economy lamps (CFLi)………………………………………………………………… 350 W
- Maximum load LED lamps 230 V………………………………………………………………………… 350 W
- Maximum load LED driver…………………………………………………………………………………. 500 VA
- Maximum load electronic transformer………………………………………………………………….. 500 VA
- Maximum capacitive load…………………………………………………………………………………. 140 μF
- Maximum switching current…………………………………………………165 A/20 ms – 800 A/200 μs
- Maximum voltage on the DALI bus………………………………………………………………………15 Vdc
- Maximum guaranteed current on the DALI bus…………………………………………………..200 mA
- Maximum supply current………………………………………………………………………………….250 mA
- Maximum startup time DALI…………………………………………………………………………< 1200 ms
- Maximum PIR detection startup time…………………………………………………………………….. 70 s
- Maximum number of dimmable zones………………………………………………………………………..4
- Maximum number of control gear on the DALI bus…………………………………………………….64
- Light intensity range……………………………………………………………………………20 – 2000 lux, ∞
- Switch-off delay………………………………………………………………………. pulse, 20 s – 120 min, ∞
- Detection angle…………………………………………………………………………………………………… 360°
- Detection range (PIR)……………………………………………………………. ø 37 m from a height of 3 m
- Ambient temperature………………………………………………………………………………. -25 – +40 °C
- Mounting method………………………………………….. flush mounting with SnapFit mounting bracket
- Mounting height…………………………………………………………………………………………….2 – 3.5 m
- Drill diameter…………………………………………………………………………………………………… 76 mm
- Minimum flush mounting depth……………………………………………………………………….. 100 mm
- Colour………………………………………………………………………………………………… white (RAL 9010)
- Dimensions visible (HxWxD)………………………………………………………….. 100 x 100 x 42.2 mm
- Dimensions (HxWxD)…………………………………………………………………… 120 x 120 x 142.2 mm
- Wire capacity…………………………………………………………………………………………….1.5/2.5 mm²
- Protection degree………………………………………………………………………………………………… IP20
- Impact resistance………………………………………………………………………………………………… IK04
- Modification of settings……………………. app (iOS/Android) and 2-way Bluetooth® communication
- Maximum range Bluetooth® (free field, depending on the device)…………………………… 50 m
- Operating frequency………………………………………………………………………………………… 2.4 GHz
- Maximum radio frequency power……………………………………………………………………….-2 dBm
- Halogen-free…………………………………………………………………………………………………………. yes
- Marking…………………………………………………………………………………………………………………CE
- Cable specifications
- Cable colour……………………………………………………………………………………………………black
- Length……………………………………………………………………………………………………………..2 m
- Wire cross-section…………………………………………………………………………………….. 1.5 mm²
- Voltage…………………………………………………………………………………………………………..400 V
- Rated current…………………………………………………………………………………………………..16 A
- Halogen-free……………………………………………………………………………………………………..yes
- Ambient temperature……………………………………………………………………………..-5 – +40 °C
- Type of connector…………………………………………………………………………..male, 5-pole, blue
Troubleshooting
The MCB rating is limited by national installation rules.
Support & contact
nv Niko sa
Industriepark West 40
9100 Sint-Niklaas, Belgium
www.niko.eu
+32 3 778 90 80 support@niko.eu
References
Read User Manual Online (PDF format)