beurer LA 35 Aroma Diffuser Instruction Manual

June 13, 2024
Beurer

beurer LA 35 Aroma Diffuser

Product Information

  • Product Name: LA 35 Aroma Diffuser
  • Manufacturer: Dong Guan City GangQi Electronics Co. Ltd.
  • Model Number: EU (100.34): GQ12-240050-AG, UK (100.35): GQ12-240050-AB Output: 24,0 V 0,5 A; 12,0 W
  • Water Capacity: 120 ml
  • Coverage Area: up to approximately 20 m2
  • Operating Mode: Ultrasound Nebulizer Mist
  • Modes: Continuous and Intermittent Continuous Mist
  • Duration: approximately 8 hours
  • Intermittent Mist Duration: approximately 16 hours
  • Weight: LA 35 – approximately 240 g, Adapter – approximately 82 g
  • Dimensions: 100 mm x 100 mm x 90 mm
  • Average Efficiency in Operation: 83.13%
  • Efficiency at Low Load (10%): 75.32%
  • Power Consumption at Zero Load: 0.10 W

Product Usage Instructions

  1. Included in Delivery:

    • LA 35 Aroma Diffuser
    • Power Adapter (Netzadapter)
    • User Manual (Gebrauchsanweisung)
  2. Signs and Symbols:

    • Importer Symbol
    • Packaging Material Identification
  3. Intended Use
    The LA 35 Aroma Diffuser is designed to disperse aromatic mist into the air for creating a pleasant and relaxing atmosphere.

  4. Warnings and Safety Notes

    • Before using the product, separate the packaging components and dispose of them according to local regulations.
    • Do not attempt to repair the product by yourself. Contact a qualified technician for any repairs.
    • Avoid placing the diffuser near flammable materials or using it in an environment where flammable gases are present.
    • Ensure that the power adapter is securely plugged into a suitable power outlet.
    • Do not touch the mist outlet or immerse it in water while the diffuser is in operation.
    • When cleaning the diffuser, ensure that the mist outlet does not come in contact with water.
    • Keep the diffuser out of reach of children and pets.
  5. Device Description:
    The LA 35 Aroma Diffuser consists of a water tank, ultrasound membrane, LED light button, power button, mist outlet, and power adapter.

  6. Usage:

  7. Initial Setup:

  * Remove the cover by pulling it upwards.
  * Fill the water tank with clean water (not exceeding the maximum capacity indicated).
  * Add a few drops of essential oil into the water if desired.
  * Place the cover back on.
2.  **Starting the Diffuser:**
  * Press the power button to turn on the diffuser.
  * Press the power button again to activate the intermittent mist mode (30 seconds on/30 seconds off).
  * Press the power button once more to activate continuous mist mode.
  * Press the power button again to turn off the diffuser.
3.  **Adjusting LED Lights:**
  * Press the LED light button to cycle through different color options.
  * Press and hold the LED light button for 3 seconds to enable color-changing mode.
  * Press and hold the LED light button again for 3 seconds to select a specific color.
  * Press the LED light button once more to turn off the LED lights.
4.  **After Use:**
  * Empty any remaining water from the tank and clean it with a soft cloth.
  * Remove any excess water from the mist outlet.
  * Store the diffuser in a cool and dry place.
  1. Cleaning and Maintenance:
    • Unplug the diffuser before cleaning.
    • Clean the water tank and ultrasound membrane regularly to prevent clogging.
    • Use a soft cloth or cotton swab to clean the mist outlet.
    • Avoid using harsh chemicals or abrasive materials during cleaning. Please refer to the user manual for more detailed instructions and safety information.
      Note: This response is based on the given text-extract from the user manual. Additional information may be available in the complete user manual.

Read these instructions for use carefully. Observe the warnings and safety notes. Keep these instructions for use for future reference. Make the instructions for use accessible to other users. If the device is passed on, provide the instructions for use to the next user as well.

WARNING

  • This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
  • Children must not play with the device.
  • Cleaning and user maintenance must not be performed by children unless supervised.
  • Disconnect the device from the mains supply during filling or cleaning.
  • Do not use any solvent-based cleaning products.
  • Do not allow the area around the device to become wet or damp. If moisture is present, reduce the humidification output of the device. If the humidification output cannot be reduced, temporarily suspend use of the device. Make sure that absorbent materials such as carpets, curtains, drapes or tablecloths do not become damp.
  • If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
  • Note that high moisture levels may promote the growth of biological organisms in the environment.
  • Never leave water in the tank when the device is not in use.
  • Micro-organisms that may be in the water or in the environment where the device is used or stored may thrive in the water tank and become airborne. This can pose serious health risks if the water is not replaced every three days and the tank is not properly cleaned.
  • Empty and clean the device before storing it away. Clean the device before the next use.

INCLUDED IN DELIVERY

Check that the exterior of the cardboard delivery packaging is intact and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the customer service address provided.

  • 1 aroma diffuser
  • 1 mains adapter
  • 1 copy of these instructions for use

SIGNS AND SYMBOLS

The following symbols are used on the device, in these instructions for use, on the packaging and on the type plate for the device:

beurer-LA-35-Aroma-Diffuser-FIG-3 beurer-LA-35
-Aroma-Diffuser-FIG-4 5beurer-LA-35-Aroma-Diffuser-
FIG-4 beurer-LA-35-Aroma-Diffuser-FIG-5

INTENDED USE

  • The aroma diffuser is only to be used for improving the ambient scent in a room. The device is intended for private use.
  • Use the device for the purpose it was developed for only and in the manner specified in these instructions for use. Any form of improper use can be dangerous. The manufacturer is not liable for damage resulting from improper or incorrect use.

WARNINGS AND SAFETY NOTES

WARNING
Failure to observe the following information may result in personal injury or material damage.

  • Keep packaging material away from children. There is a risk of suffocation!
  • If you suffer from a severe respiratory or lung disease, consult your doctor before using the device.
  • If you start to feel unwell while the device is in use, stop using it immediately, switch the device off and ventilate the room.
  • The device is only to be used with the recommended vaporisation agent. The use of other substances may trigger toxic reactions, or pose a fire risk.

Electric shock
WARNING

  • As with every electrical device, use this device carefully and cautiously, in order to avoid hazards due to electric shock.
  • Therefore, observe the following instructions for use:
    • Only use this device with the voltage specified on the device
    • Never use the device if it shows visible signs of damage
    • Do not use the device during a storm
  • In the event of defects or operational faults, switch the device off immediately and disconnect it from the mains socket. Do not pull on the mains cable or on the device to disconnect the mains adapter from the socket. Never hold or carry the device by the mains cable.
  • Only use the device in dry rooms (e.g. never in the bath, sauna).
  • Never pick up a device that has fallen into water. Disconnect the mains adapter immediately.
  • Do not drop the device or subject it to any impacts.
  • Do not clamp or pinch the mains cable.
  • Ensure that the mains cable and mains adapter do not come into contact with water, steam or other liquids.

Repairs
WARNING
Only specialist personnel may perform repairs on electrical devices. Improper repairs may put users in significant danger. For repairs, please contact Customer Services or an authorised retailer.

Risk of fire
WARNING

  • There may be a risk of fire if the device is used improperly or these instructions for use are ignored.
  • Therefore, observe the following instructions for use:
    • Never use the device underneath a cover, such as a blanket, pillow, etc.
    • Never use the device near petrol or other highly flammable substances.

Handling
CAUTION

  • The device must be switched off and disconnected after every use and before cleaning.

  • Ensure that the mains cable does not pose a trip hazard.
    Do not insert any objects into openings on the device.

  • Do not place any objects on the device.

  • Ensure that the device is placed on a firm, secure surface that is not susceptible to moisture.

NOTICE

  • Do not expose the device to high temperatures.
  • Avoid water da
  • mage by handling the device carefully (e.g. water damage from splashing in the vicinity of wooden floors).
  • If the device should accidentally tip over, water may escape, even if the device is switched off and unplugged.
  • The immediate vicinity of the device can become damp.
  • Depending on the water quality and temperature, the amount of mist may be lower at the beginning.
  • Calcareous water can leave white deposits.
  •  Do not place the device on the floor, but in a raised position (e.g. on a table or chest of drawers).
  • Position the device so that the mist outlet is not directed towards objects.
  • Empty any remaining water when the device is not in use.
    The water tank and the cover are made of oil-resistant materials. Keep aroma oils away from other components of the device as these could become damaged by certain ingredients within the oils.

DEVICE DESCRIPTION

The associated drawings are shown on page 3.

beurer-LA-35-Aroma-Diffuser-FIG-2

  1. Outlet 8 sensor area for buttons
  2. Cover 9 Air outlet
  3. ON/OFF button 10 “MAX” marking (maximum fill level)
  4. LED button 11 Mains adapter
  5. Splash protection 12 Connection socket
  6. Ultrasound membrane 13 Air inlet
  7. Water tank

USAGE

Initial use
WARNING

  • Only fill the device when the mains adapter is unplugged!
  • NEVER fill the device when the cover is still attached.
  • Only use water-based aroma oils.
  • Open the cardboard packaging, remove all the packaging film and check the device for damage.
    1. Pull the cover 2 up and off.
    2. Fill the water tank 7 with water. Ensure that you do not fill the water tank 7 above the “MAX” marking 10. If the water is very hard, use distilled water.
    3. Place 2 to 3 drops of the desired aroma oil (water-based) into the water tank 7 .
    4. Replace the cover 2 on the water tank 7 from above. Connect the mains adapter 11 to the connection socket 12 on the underside of the device and to a suitable socket.

beurer-LA-35-Aroma-Diffuser-FIG-6

Starting use

  • Press ON/OFF button 3 once = Device switches on and operates on highest intensity (continuous mist)
  • Press ON/OFF button 3 twice = Intermittent mist (30 Seconds on/30 seconds off)
  • Press ON/OFF button 3 three times = Device switches off
    The device switches off automatically if there is a lack of water.

Adjusting the LED light
The device has an optional LED light.

  • Press LED button 4 once = LED light intensity 100%
  • Press LED button 4 twice = LED light intensity 50%
  • Press LED button 4 three times = LED switches off

After use

  1. Press the ON/OFF button 3 repeatedly until the device is switched off.
  2. Disconnect the device from the socket and the mains adapter 11 .
  3. Pull the cover 2 up and off.
  4. Pour any remaining water down the drain as shown. Ensure that the air outlet 9 does not come into contact with water.

CLEANING AND MAINTENANCE

CAUTION
Before cleaning the device, ensure that the device is disconnected from the power supply and that there is no water left in the water tank 7 . Regular cleaning is a prerequisite for hygienic and faultfree operation. The aroma diffuser can be dismantled for cleaning easily and without tools (see chapter “6.1 Initial use”).

  • In the middle of the water tank 7 , the device has an ultrasound membrane 6 . Carefully clean the ultrasound membrane 6 using a cotton bud each week. Depending on the frequency of use, you can also clean the ultrasound membrane 6 several times a week.
  • Clean the device after every use using a soft, slightly damp cloth, paying particular attention to the inside of the water tank 7 . Never use abrasive, corrosive or solventbased cleaning products.
  • If a layer of limescale forms in the water tank 7 , briefly apply a citric acid or vinegar solution beforehand.

ACCESSORIES AND REPLACEMENT PARTS

To purchase accessories and replacement parts, please visit www.beurer.com or contact the corresponding service address (according to the service address list) in your country. Accessories and replacement parts are also available from retailers.
Beurer by Taoasis “Vitality” aroma oil (10 ml) 681.30

WHAT IF THERE ARE PROBLEMS?

beurer-LA-35-Aroma-Diffuser-FIG-8 beurer-LA-35
-Aroma-Diffuser-FIG-9

DISPOSAL

For environmental reasons, do not dispose of the device in household waste at the end of its service life. Dispose of the device at a suitable local collection or recycling point in your country. Observe the local regulations for material disposal. Dispose of the device in accordance with EC Directive Waste Electrical and Electronic Equipment (WEEE). If you have any questions, please contact the local authorities responsible for waste disposal. You can obtain the location of collection points for old devices, for example, from the local or municipal authorities, local waste disposal companies or your retailer

TECHNICAL SPECIFICATIONS

Product name LA 35
Power supply Input: 100–240 V, ~50/60 Hz, 0.4 A Output: 24.0 V          0.5

A; 12.0 W
Water tank capacity| 120  ml
Room size| Up to approx. 20 m2
Operating principle| Ultrasonic atomiser
Mist settings| Continuous mist and intermittent mist
Running time| Approx. 8 hours of continuous mist Approx. 16 hours of intermittent mist
Weight| LA 35: approx. 240 g Adapter: approx. 82 g
Dimensions| 100  mm x 100 mm x 90 mm
Average efficiency during operation| ≥ 83.13 %
Efficiency at low load (10%)| ≥ 75.32 %
No-load power consumption| ≤ 0.10 W
Mains adapter| Manufacturer:

Dong Guan City GangQi Electronics Co. Ltd.

Model number:

EU (100.34): GQ12-240050-AG

UK (100.35): GQ12-240050-AB

WARRANTY

Further information on the warranty and warranty conditions can be found in the warranty leaflet supplied.

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Beurer User Manuals

Related Manuals