Honeywell RCHT8612WF T5+ Smart Thermostat Programmable Thermostat User Guide
- June 6, 2024
- Honeywell
Table of Contents
- Included in your box
- Get the most from T5 Smart Thermostat
- Compatibility
- Removing your old thermostat
- Setup with Honeywell Home App
- How to use your Honeywell Home App
- How to use your T5 Smart Thermostat
- Manual Setup
- Equipment Setup Options
- ISU| ISU Name| ISU Options (defaults in bold)| Notes
- Frequently Asked Questions
- Regulatory information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
T5+ Smart Thermostat
Programmable Thermostat
RCHT8610WF, RCHT8612WF
Product Data
For more information visit honeywellhome.com
Included in your box
Get the most from T5 Smart Thermostat
Multiple programming options that fit your lifestyle:
- Location-Based scheduling – The thermostat uses your smartphone’s location to know when you’re away and saves you energy. Through geofence technology, it senses your return and helps make you comfortable upon arrival. You can always manually change your preset Home and Away temperature either on the thermostat or on the Honeywell Home app.
- Smart scheduling – Use a combination of geofencing and time scheduling to fit your busy, active lifestyle.
- Time-Based scheduling – Program your thermostat for one week; each day (each day is a different schedule); Mon-Fri, Sat, Sun; or Mon-Fri, Sat-Sun. All days with four adjustable periods per day.
- No schedule – Control your comfort manually by adjusting temperature set points only.
Smart Alerts. Push notifications remind you of filter changes and warn
you of extreme indoor temperatures.
Smart Response. Learns your heating and cooling system to deliver the
optimal temperature at the right time.
Auto Change From Heat to Cool. Automatically determine if your home needs
heating or cooling to provide maximum comfort.
Read and save these instructions.
Tools you will need
You may need
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage,
avoid cycling the compressor quickly.
CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash. Contact your local waste management
authority for instructions regarding recycling and proper disposal.
REQUIRED: 24 VAC POWER (“C” WIRE)
C-Wire Power Adapter Included providing power if needed.
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
Compatibility
- Compatible with most heating, cooling, and heat pump systems
- Required: 24 VAC power (“C” wire). C-Wire Power Adapter Included providing power if needed
- Does not work with electric baseboard heat (120-240V)
- Does not work with millivolt systems
- Does not support input (S terminals) for indoor and outdoor sensors
- Does not support relay (U terminals) for ventilation
- Android or iOS smartphone, tablet, or device
For help, contact
WEB honeywellhome.com/support
PHONE 1-800-633-3991
SOCIAL Twitter: @Honeywell_Home, Facebook: Honeywell Home
Removing your old thermostat
-
Turn power OFF
To protect yourself and your equipment, Turn off the power at the breaker box or switch that controls your heating/cooling system. -
Check that your system is off Change the temperature on your old thermostat. If you don’t hear the system turn on within 5 minutes, the power is off.
Note: If you have a digital thermostat that has a blank display, skip this step. -
Remove your old thermostat from the wall plate On most thermostats, you can take off the thermostat by grasping and gently pulling. Some thermostats may have screws, buttons, or clasps. Do not remove any wires from your thermostat at this time!
-
Make sure there are no 120/240V wires Do you have thick black wires with wire nuts?
Is your thermostat 120V or higher?
If you answered yes to either of these questions, you have a line voltage system and the thermostat will not work.
If you are unsure visit: honeywellhome.com/support -
Take a picture of how your wiring looks right now Be sure to include the letters next to the terminals where the wires are inserted. This will be a helpful reference when wiring your thermostat.
Tip: If the color of your wires has faded or if 2 terminals have the same wire color, use the wire labels provided in the package to label each wire. -
Remove any jumpers A jumper connects one terminal to another terminal. It may look like a small staple or even a colored wire and must be removed before continuing. Use a screwdriver to release wires from terminals.
The thermostat does not need jumpers. -
Record if you have wires in the following terminals
Do not include jumpers as a part of your count. The thermostat does not need jumpers. -
Write down the color of the wires
Checkmark the wires that are connected to terminals. Next to the checkmark, write down the color of the wire.
Do not include jumpers as a part of your count.
Check all that apply (Not all will apply):
S and U terminals are not supported with this thermostat.
If there are wires in terminals that are not listed, you will need additional wiring support.
Visit honeywellhome.com/support to find out if the thermostat will work for you. -
Do you see a wire connected to the C terminal?
If yes, skip stepping 10.
If you do not see a C wire, proceed with the options below:
Option A – Finding the C-Wire:
There might be an extra wire pushed into the wall or wrapped around the wire bundle. Gently pull the wire bundle out of the wall to check for unused wires.
If you have an unused wire, connect that wire to the C terminal on your new thermostat in step 13.
Connect the other end of the unused wire to the C terminal on your heating/cooling system (or the zone panel if your home uses more than one thermostat to control temperature). Be sure any other wire(s) connected to the C terminal stay securely connected when you re-tighten the terminal.
Not all heating/cooling equipment uses the C label for the 24 VAC common wire. If your heating/cooling equipment does not have a C terminal, check the system manually or contact the manufacturer to find out which terminal is the 24 VAC common.
Complete installation by following the remaining steps in this guide.
Option B – Using the C-Wire Power Adapter:
If you do not have an unused wire in the wall, see the C Wire Adapter
Installation Guide included in the box. Open the top or bottom flap of the box to locate the C Wire Adapter -
Disconnect the wires and remove the old wall plate
Use a screwdriver to release wires from terminals.
Tip: To prevent wires from falling back into the wall, wrap the wires around a pencil.
Installing your T5 Smart Thermostat
-
Bundle and insert wires through the UWP
Pull open the UWP and insert the bundle of wires through the back= of the UWP.
Make sure at least 1/4-inch of each wire is exposed for easy insertion into the wire terminals. -
Insert the wall anchors
It is recommended that you use the wall anchors included in the box to mount your thermostat.
You can use the UWP to mark where you want to place the wall anchors.
a) Level the wall plate.
b) Mark the location of the wall anchors using a pencil.
c) Drill the holes.
d) Insert wall anchors.
e) Make sure anchors are flush with wall.
Tip: Use a 7/32 drill bit. -
Set R-switch position and insert R-wire or wires
Set the R-switch up or down based on your wiring notes in Step 7.
Insert wires into the inner holes of the terminals on the UWP. The tabs will stay down once the wire is inserted.
If you have 1 R-wire (R, Rh, or Rc)
1. Set R-switch to the up position.
2. Insert your R-wire (R, Rh, or Rc) into R-terminal.
or
If you have 2 R-wires (R or Rh, and Rc)
**1. Set R-switch to the down position.| 2. Insert your Rc wire into Rc- terminal.
3. Insert your R or Rh wire into R-Terminal.
---|---
**|
-
Connect remaining wires from Step 8
Tip: Do not mount the UWP to the wall prior to connecting the wires.
Depress the tabs to put the wires into the inner holes of their corresponding terminals on the UWP (one wire per terminal) until it is firmly in place.
Gently tug on the wires to verify they are secure.
Tip: If you need to release the wires again, push down the terminal tabs on the sides of the UWP. -
Mount the UWP and close the door
Mount the UWP using the provided screws. Install all three screws for a secure fit on your wall. Close the door after you’re finished. 1/4” to 3/8” -
Attach your thermostat
Align the thermostat onto the
UWP and firmly snap it into place. -
Turn your power ON
Turn on the power at the breaker box or switch that controls the heating/cooling system. -
Return to the thermostat
Return to the thermostat. Confirm the screen shows START SETUP. If it does, continue to “Setup with Honeywell Home App” below.
If your thermostat does not show START SETUP, please contact Resideo support.
Setup with Honeywell Home App
-
Start Setup with the app Touch START SETUP on the thermostat.
-
Select to set up with the app Touch Yes on the USE APP screen.
-
Your thermostat is now ready to be configured using the Honeywell Home app
a) Download the “Honeywell Home” app from the App Store or Google Play.
b) Open the Honeywell Home app. Your thermostat should appear under Thermostat Found. Tap SET UP NOW as shown below to continue. If your thermostat doesn’t appear, create an account
(if necessary), or sign in to your Honeywell Home account. Then select the T5 Smart Thermostat to install.
c) The Honeywell Home app will walk you through the rest of the setup.
How to use your Honeywell Home App
Interested in more Resideo products? Visit honeywellhome.com to learn about
all available products connected by the Honeywell Home app.
App is regularly enhanced and may change.
How to use your T5 Smart Thermostat
The screen will wake up by touching the center area of the displayed temperature.
Manual Setup
If your Wi-Fi network is not working, you can alternatively set up your thermostat manually and connect your phone later.
-
Start manual setup
Touch START SETUP to begin. -
Select manual setup
On the USE APP screen, touch No -
Navigate and edit setup options
Use < or > navigate through all the setup options. To see a list of all setup options, go to pages 6-7.
To edit an option value, touch Edit or touch the text area.
The value is now blinking. Use < or > select the correct value.
Touch Done or touch text area once the correct value is selected. -
Finish Setup
Touch until you see Finish
Setup. Touch Select or touch text area. -
Setup Wi-Fi
At the end of the setup process, you will be prompted to SETUP WIFI. If your Wi-Fi is still not working, you have to manually set the time and date. Select No on the SETUP WIFI screen. -
Set time and date
Set daylight saving time if you are in an area that follows daylight saving time. Set date, clock format, and time on the next screens. -
Your thermostat is now setup
Refer to page 5 for more information about the basic operation.
Equipment Setup Options
Note: ISU options available may vary upon the thermostat model and equipment setup.
# ISU
| ISU Name| ISU Options (defaults in bold)|
Notes
---|---|---|---
120| Schedule Type| No Schedule
MO-SU = Every day the same MO-FR, SA, SU = 5-1-1 schedule MO-FR, SA-SU = 5-2 schedule Each Day = Every day individual
| You can change the default MO-FR, SA-SU schedule here. To edit periods
during days, temperature setpoints, or to turn Schedule On/Off, from the home
screen, go to MEN U / S C HE D ULE.
125| Temp Scale| Fahrenheit , Celsius|
130| Outdoor Temp| No, Internet| Select outdoor temperature data source.
This ISU automatically defaults to the Internet when registered to the
Honeywell Home app. An outdoor temperature is required to set the following
ISUs: ISU 355 Compressor Lockout, ISU 356 Aux Heat Lockout.
200| System Type| Conventional Forced Air
Heat Pump Boiler
Cool Only| A basic selection of system your thermostat will control.
205| Equipment Type| Conventional Forced Air Heat:
Standard Gas (STD GAS), High-Efficiency G a s ( E
F F G A S ) , Oil, Electric, Fan Coil*
Heat Pump:
Air To Air, Geothermal
Boiler:
Hot Water , Steam| This option selects the equipment type your thermostat
will control. Note: This option is NO T displayed if ISU 200 is set to
Cool Only.
- Fan coil setting is for a residential application with a hot water coil in an air-handler.
218| Reversing Valve| 0/B on Cool, 0/B on Heat| This ISU is only
displayed if ISU 200 is set to Heat Pump. Select whether reversing valve O/B
should energize on cool or on heat
220| Cool Stages (#200=Conv./ 200=HP)| 0, 1 , 2|
221| Heat Stages/ Aux/E Stages (#200=Conv./ 200=HP)| Heat Stages: 0, 1 , 2
AUX/E Stages: 0 , 1| Maximum of 2 Heat Stages for conventional systems.
Maximum of 1 Aux/E stage for heat pump systems.
230| Fan Control| Equipment, Thermostat| This ISU is only displayed if
ISU 205 is set to Electric Forced Air or Fan Coil.
300| Auto Changeover| On, Off| OFF: The user must select heating or
cooling as needed to maintain the desired indoor temperature.
ON (Automatic): On (enabled) Allows the user to select Auto Changeover as one of the system modes from the home screen. In auto mode, the thermostat can control either heating or cooling to maintain the desired indoor temperature.
303| Auto Differential| 0 ° F to 5 °F or 0 . 0 °
C to 2.5 °C| The differential is the minimum number of degrees rise or
fall required during off-cycle to switch from the last active mode (heat or
cool) to the opposite mode when the thermostat is in auto-changeover. The
differential is NOT deadband. The deadband temperature between when heating
(or cooling) cycles on and cycles off to maintain the setpoint is not
adjustable. The T5 thermostat uses an algorithm that fixes Deadband at 0 °F.
355| Balance Point (Compressor Lockout)| O f f , 5 °F to 60
°F (in 5 °F increments) or -15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C
increments)| Compressor Lockout requires an outdoor temperature. Set
Compressor Lockout to the temperature below which is inefficient to run the
heat pump. When the outside temperature is below this setting, the thermostat
will lock out the heat pump and run Aux Heat only. This ISU is only displayed
if ISU 130 = Internet, ISU 200 is set to Heat Pump, ISU 221 Aux/E stages = 1,.
356| Aux Heat Lock Out (Aux Heat Outdoor Lockout)| Off, 5 °F to 65 °F (in
5 °F increments) or -15.0 °C to 18.5 °C (in 2.5 °C or 3.0 °C increments)| Aux
Heat Lockout requires an outdoor temperature. Set Aux Heat Lockout to optimize
energy bills and to not allow it to run the more expensive Aux Heat source
above a certain outdoor temperature limit. This ISU is only displayed if ISU
200 is set to Heat Pump, AND if ISU 221 Aux/E stages = 1.
365| Cool 1 CPH (Cooling cycle rate stage 1)| 1 – 6 CPH (3 CPH)| This ISU
is only displayed when Cool /Compressor Stages is set to 1 or more stages.
Cycle rate limits the maximum number of times the system can cycle in a 1 hour
period measured at a 50% load. For example, when set to 3 CPH, at a 50% load,
the most the system will cycle is 3 times per hour (10 minutes on, 10 minutes
off). The system cycles less often when load conditions are less than or
greater than a 50% load.
366| Cool 2 CPH (Cooling cycle rate stage 2)| 1 – 6 CPH (3 CPH)| This ISU
is only displayed when Cool /Compressor Stages is set to 2.
ISU| ISU Name| ISU Options (defaults in bold)| Notes
370| Heat 1 CPH (Heating cycle rate stage 1)| 1 – 12 CPH| This ISU is only displayed when Heat Stages is set to 1 stage or more stages. Cycle rate limits the maximum number of times the system can cycle in a 1 hour period measured at a 50% load. For example, when set to 3 CPH, at a 50% load, the most the system will cycle is 3 times per hour (10 minutes on, 10 minutes off). The system cycles less often when load conditions are less than or greater than a 50% load. The recommended (default) cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High-Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant Heat = 3 CPH; Steam = 1 CPH.
371| Heat 2 CPH (Heating cycle rate stage 2)| 1 – 12 CPH| This ISU is only displayed when Heat Stages is set to 2 stages. The recommended (default) cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High-Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant Heat = 3 CPH; Steam = 1 CPH.
375| Aux Heat CPH (Heating cycle rate Auxiliary Heat)| 1 – 12 CPH| This ISU is only displayed when ISU 200 = Heat Pump and ISU 221=1. It is only displayed when Auxiliary Heat is configured. The recommended cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High-Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH.
425| Smart Response| On, Off| Smart Response is a comfortable setting. Heating
or cooling equipment will turn on earlier, ensuring the indoor temperature
will match the setpoint at the scheduled time.
429| Max Cool Temperature| from Min. Cool Temp. to 99 °F or to 37.0 °C (90 °F
or 32 °C)| The user cannot set the cooling temperature above this level.
430| Min Cool Temperature| from 50 °F or 10.0 °C to Max. Cool Temp. (50 °F or
10 °C)| The user cannot set the cooling temperature below this level.
431| Max Heat Temperature| from Min. Heat Temp. to 90 °F or to 32.0 °C (90 °F
or 32 °C)| The user cannot set the heating temperature above this level.
432| Min Heat Temperature| from 40 °F or 4.4 °C to Max. Heat Temp. (50 °F or
10 °C)| The user cannot set the heating temperature below this level.
702| Air Filters| 0 – 2| This ISU refers to the number of air filters in the
system.
711| Air Filter 1 Reminder| Off 10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days 3, 4, 5, 6, 9, 12, 15 Months| Choose either calendar or
equipment run time-based reminder.
712| Air Filter 2 Reminder| Off 10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days 3, 4, 5, 6, 9, 12, 15 Months| Choose either calendar or
equipment run time-based reminder.
810| Hum Pad Reminder| Off 6, 12 Calendar Months|
921| Dehum Filter Reminder| Off 30, 60 Calendar Days 3 – 12 Calendar Months
(in 1-month increments)|
1018| Vent Filter Reminder| Off, 3, 6, 9, 12 months|
1100| UV Devices| 0 – 2| Some systems may have two UV devices, one for the
A-Coil and another for Air Treatment. A replacement reminder can be set up for
each one separately.
1105| UV Bulb 1 Reminder| Off, 6, 12, 24 months|
1106| UV Bulb 2 Reminder| Off, 6, 12, 24 months|
1401| Idle Brightness| 0= Off, 0 – 5| Adjust the brightness of an inactive
backlight (idle screen) from default 0 (backlight off) to 5 (maximum
brightness).
1410| Clock Format| 12 hour, 24 hour|
1415| Daylight Saving| On, Off| Set to Off in areas that do not follow
Daylight Saving Time.
Frequently Asked Questions
Will the T5 Smart Thermostat still work if the Wi-Fi connection is lost?
Yes, the temperature can be adjusted directly at the thermostat. However, some
features, including geofencing, are managed only
through the Honeywell Home app and will not function while the connection is
down. The thermostat will automatically reconnect to WiFi once the network is
restored.
The T5 Smart Thermostat is not finding the in-home Wi-Fi network.
The thermostat operates in the 2.4GHz range. That may be why the thermostat
does not see the network but the smartphone, which operates in both the 2.4
and 5.0 GHz range, sees the network. Most routers will broadcast two networks,
one SSID on the 5.0 GHz radio and one SSID on the 2.4 GHz radio.
A change was made on the Honeywell Home app but it has not shown up on the
T5 Smart Thermostat.
There may be a short delay after making temperature and setting changes in the
Honeywell Home app.
Can there be multiple users for geofencing?
Yes, there can be multiple users. Geofencing will trigger based on the last
person to leave and the first person to return. To properly use geofencing
with multiple users:
- Each user needs to create their own account.
- Each user should use their login ID and password across his or her devices, including smartphones and tablets.
- No two users should share the same account.
How are multiple users set up with a thermostat?
Access can be given to any or all thermostat locations through the Honeywell Home app. Start by touching the three-line menu icon in the upper left-hand corner of the home screen. Select Manage Users and touch Add User located at the bottom of the screen. Type in the email address of the person to be invited. If they have an account set up, the location will be automatically added to their account. If they don’t have an account, they will receive an email invitation prompting them to download the Honeywell Home app and create their own account.
Note: All individuals with access to a thermostat share the same user
privileges. Users added will be able to change the thermostat’s
settings, as well as add or delete other users.
Is there a way to extend the signal strength?
The range or distance of the Wi-Fi signal is determined by the router. Check
the router’s manual for additional information.
There is an alert that says Wi-Fi Signal Lost. What does that mean?
The Wi-Fi signal to the thermostat has been lost. Wait for the thermostat to
reconnect or select a new network within the Honeywell
Home app configuration menu. If the thermostat is unable to reconnect, you
will need to troubleshoot the router to determine the cause.
Why is the thermostat showing up as offline (strike-through Wi-Fi icon) on
top of the right corner of the thermostat display?
If the thermostat displays a strike-through Wi-Fi icon on its screen or shows
up as offline on the Honeywell Home app, it has lost
connection to the network. Make sure the router is powered and broadcasting.
The home’s Wi-Fi network may need to be reset by power cycling the router.
Consult the router’s instruction manual for directions on power cycling. When
the network has been restored, the thermostat will automatically reconnect.
An activation email hasn’t been received.
An email will be sent from connected-Home@alarmnet.com. An activation email is needed to complete the account
setup. If an activation email is not received after five minutes, check the
Spam folder of the email account.
If you do not find it in the Spam folder, click on the Resend button and the activation email will be resent. If you still do not receive your activation email, please contact the Technical Support team at 1-800-633-3991 for help.
Regulatory information
FCC REGULATIONS
47 CFR § 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
47 CFR § 15.21 (USA only)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
47 CFR § 15.105 (b)
See https://customer.resideo.com/en-US/support/residential/codes-and-
standards/FCC15105/Pages/default.aspx for additional FCC information for this
product.
IC REGULATIONS RSS-GEN
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development
Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Apple® HomeKit™ Setup Code
The T5 Smart supports Apple HomeKit. When prompted by the
Honeywell Home app, scan the code on the back cover of the guide included with
your T5 Smart thermostat.
2-Year Limited Warranty
For Warranty, information go to honeywellhome.com
www.resideo.com
Resideo Inc., 1985 Douglas Drive North
Golden Valley, MN 55422
33-00474-01 M.S. 4-19 | Printed in the United States
©2019 Resideo Technologies, Inc.
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN,
1-800-633- 3991.
The Honeywell Home trademark is used under license from Honeywell
International Inc. All rights reserved.
Wi-Fi® is a registered trademark of
Wi-Fi Alliance®33-00474-01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>