Color IMAGINATION FS600 Stage Lighting LED Moving Head Light User Manual

June 13, 2024
Color IMAGINATION

FS600
PROSPOT 600MCF

User Manual
KEEP THIS MANUAL FOR FUTURE NEEDS

SAFETY INSTRUCTIONS

CAUTION
Becareful with your operations.With a dangerous voltage you cansuffer a dangerous electric shock when touching wires!
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
IMPORTANT
Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.
If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device.
Leave the device switched off until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be earthed.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually.
Please don’t project the beam onto combustible substances.
Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for smooth air flow, so there should be no shelter for fans and ventilation for heat radiation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

CH3S

|

The aperture

| 0-127.| From big to small
---|---|---|---
128-255.| Function of contraction
210-215.| Reset XY for more than 6 seconds
CH36| reset| 220-235.| More than 6 seconds reset effect motor
240-255.| Reset all after 6 seconds
| | 213-215.| stop
216-255.| From slow to fast reverse flow
CH1S| Pattern of glass| 0-9| The white light
10-79.| Switching patterns
80-149.| Pattern shake, from slow to fast
150-190.| From fast to slow forward water
191-192.| stop
193-255.| From slow to fast reverse flow
CH16| Glass pattern rotation| 0-127.| Switch of angles
128-190.| From fast to slow forward water
191-192.| stop
193-255.| From slow to fast reverse flow
CH17| Disc of effect| 0 to 10| Remove the
11-255.| Linear insertion
CH18| Effect spiral turn| 0-2| stop
3-128.| From fast to slow forward water
129-255.| From slow to fast reverse flow
CH19| focusing| 0-255.| From far to near
CH2O| Focus tuning| |
CH21| amplification| 0-255.| From small to big
CH22| A prism| 0-127.| Remove the prism
128-255.| A prism
CH23| Rotation of prism| 0-127.| Switch of angles
128-187.| From fast to slow forward water
188-195.| stop
196-255.| From slow to fast reverse flow
CH24| keep| |
CH25| atomization| 0-127.| There is no
128-255.| atomization
CH26| Section 1| 0-255.| Linear insertion
CH27| Section 2| 0-255.| Linear insertion
CH28| Section 3| 0-255.| Linear insertion
CH29| Section 4| 0-255.| Linear insertion
CH30| Section 5| 0-255.| Linear insertion
CH31| Section 6| 0-255.| Linear insertion
CH32| Section 7| 0-255.| Linear insertion
CH33| Section 8| 0-255.| Linear insertion
CH34| Cutting rotary plate| 0-255.| Angle of slice

Product Introduction

  • Input voltage: AC100-240V, 50/60Hz
  • Rated power: S00W
  • Light source: 600W LED module
  • LED life: 20,000 hours
  • Color temperature: 6800K
  • Caliber: 138mm Frontal lens for greater performance
  • Color rendering index: Standard mode Ra>72, high CRt mode Ra>90
  • Luminous flux: 24000LM
  • Signal interface: three-pin XLR (five-pin XLR optional)
  • Control mode: DMX512, RDM, Auto Mode, master-slave, Sound activation
  • Channel mode: 36CHs
  • Display system: 2.7-inch touch LCD display, Chinese and English display, 180-degree rotation
  • Fixed color: 6 colors + open position
  • Color mixing system: independent CMY color mixing system
  • Color temperature adjustment: independent CTO 2500K-7000K linear adjustment
  • Prisms: Rotating 3-faced prism
  • Effect wheel: dynamic effects such as stunning simulated dynamic flames, gurgling water, etc.
  • Fixed Gobo wheel: 7 fixed gobos+open position
  • Rotating gobo Wheel: 7 gobos (pluggable), outer diameter 22.9mm, effective diameter 16mm, thickness 1.1mm+Open position
  • Framing system: 4 Individually positionable Shutter Blades, each piece can be closed separately and can be rotated +/- 90°
  • Frost system: 0~ 100% linear atomization
  • Iris system: 5%~100% smooth adjustment
  • Beam Aperture: 4.5°~50° fast motorized linear zoom
  • Dimming system: 0-100% linear adjustment
  • Strobe system: the highest frequency can reach 25Hz, and random strobe and pulse strobe can be selected
  • Pan: 540° (16 bit precision scanning)
  • Tilt: 270° (16 bit precision scanning)
  • Pan/Tilt: Five-phase motor with magnetic encoding positioning function
  • Protection rate: IP20
  • Working environment: 0-45°C
  • Product size: 424286770(mm)
  • Carton size: 730*690″590 (mm)
  • Product net weight: 35KG
  • Product gross weight:4.5KG
  • Product appearance: flame retardant, high temperature resistance, folding clamp

Color IMAGINATION FS600 Stage Lighting LED Moving Head Light -
panel

The following takes “Modify DMX address code” as an example to describe the use of keys:

  1. If the current home screen is not displayed, press the Left key (one or more times) to return to the home screen
  2. On the home screen, press the Up or Down key to select the Settings button
  3. Press the OK key to enter the Settings screen
  4. In the “Settings” interface, press the “Up” key or “Down” key to select “DMX Address”
  5. Press “OK” to enter the editing state
  6. Press the “Up” key or “Down” key to modify the DMX address code
  7. Press the “OK” key to exit the editing state
  8. Press the right button on the main interface to enter the calibration menu.

2.2.1 DMX Settings
Key description: Press up or down to +1 or -1 mode;Press one or the next, quickly adjust the address code mode;Press the Confirm key to return Manual instruction: Enter the hundreds place, then the tens place, and then the last place.(For example, if you enter 286, click 2, then 8, and finally 6)
2.2.2 Medium /En
English and Chinese interface switch;

26 Section 1
27 Section 2
28 Section 3
29 Section 4
30 Section 5
31 Section 6
32 Section 7
33 Section 8
34 Cutting rotary plate
35 The aperture
36 reset

Channel parameter values (lull version) :

Channel 1 The name of the The numerical describe
CHI X 0255. 0540 degrees
CH2 X fine tuning 0-255. 0.2 degrees
CH3 X 0-255. 0-270 degrees
CH4 Y fine tuning 0-255. 0.1 degrees
CHS XV velocity 0-255. From fast to slow
CH6 Cut light/stroboscopic 0.3 GuanGuang
4-127. From slow to fast pulse stroboscopic
128.191. It goes from slow to fast
192-251. From slow to fast random stroboscopic
252-255. medallion
CH7 The dimmer 0-255. 0-100% dimming
CH8 C 0-255.
CH9 M 0-255.
CHIO X 0-255.
CH11 CTO 0-255.
CH12 Disk of color 0-127. linear color
128-191. Switching colors
192-222. From fast to slow forward water
223-224. stop
225-255. From slow to fast reverse fiow
CH13 Finger display plate 0-255. Linear insertion
CH14 Fixed pattern plate 0.9 The white light
10-129. Switching patterns
130-189. Pattern shake, from slow to fast
190-212. From fast to slow forward water
Cut 3
--- --- ---

Cut 4
Cut 5
Cut 6
Cut 7
Cut 8
XY speed adjustment| X axis velocity| 000-255, speed slow to fast adjustment
`I axis velocity
Regulation of fan| Regulation of fan| Only do temporary adjustment, power does not save
Fan speed

Function of channel

3.1 Table of channels

channel Channel mode

Channel 36
1| X
2| X fine tuning
3| Y
4| Y fine tuning
5| XY velocity
6| Cut light/stroboscopic
7| The dimmer
8| C
9| M
10| r
11| CTO
12| Disk of color
13| Slice of value
14| Fixed pattern plate
15| Pattern of glass
16| Glass pattern rotation
17| Disc of effect
18| Effect spiral turn
19| focusing
20| Focus tuning
21| amplification
22| Prism 1
23| Prism 1 rotation
24| keep
25| atomization
| Time of use| Usage time since this startup (accurate to minutes)
---|---|---
Date of manufacture|
Permission Duration| 9999 indicates no encryption and can be used for a long time. Other values represent the remaining use time, encrypted;
Sensor monitoring| X Hall| 0 when magnetic is detected, 1 otherwise
Y Hall| 0 when magnetic is detected, 1 otherwise
Color plate hall| 0 when magnetic is detected, 1 otherwise
CMY Hall| 0 when magnetic is detected, 1 otherwise
CTO Hall| 0 when magnetic is detected, 1 otherwise
Fixed pattern pan| 0 when magnetic is detected, 1 otherwise
Glass pattern hall| 0 when magnetic is detected, 1 otherwise
Glass pattern rotation Hall| 0 when magnetic is detected, 1 otherwise
Focus hall| 0 when magnetic is detected, 1 otherwise
Enlarge Hall| 0 when magnetic is detected, 1 otherwise
Prism 1 rotary hall| 0 when magnetic is detected, 1 otherwise
X Code disk status| Two digits, each corresponding to a photoelectric switch in the code disc
Y Code disk status| Two digits, each corresponding to a photoelectric switch in the code disc
X-axis encoding disk step value| The number of steps should increase when walking in the forward direction and decrease when walking in the opposite direction.Every time you go to the same point, the value is normal
Y-axis encoding disk step value| The number of steps should increase when walking in the forward direction and decrease when walking in the opposite direction.Every time you go to the same point, the value is normal
System error| | If the red ERR indicator lights up, it indicates that the lamp is running incorrectly. You can enter the sub-interface to check the details.After viewing, you can press the “Clear’ key to clear the error record
DMX channel value
monitoring| | The sub-screen displays the channel value in numerical and percentage terms for viewing
Common Error Messages| instructions
---|---
Failed to connect the MT board. Procedure| The motor board is not responding.The serial communication line connecting the display board and the motor board is faulty, or the motor board is faulty.
X-axis reset failed| X-axis photoelectric switch, or X-axis motor or motor board has a problem
Y-axis reset failed| Y-axis photoelectric switch, or Y-axis motor or motor board is faulty
X axis Hall error| There is a problem with X shaft Hall or motor board
Y-axis Hall error| Y-shaft Hall, or motor board problem
Description Failed to reset the color disk| Color plate hall, or color plate motor has a problem
Description The pattern
disk failed to reset| Pattern plate hall, or pattern plate motor problem
Failed to reset the focus| The focusing hall, or the focusing motor has a problem

2.2.4 Lighting setup

options instructions
DMX channel 36CH
language Chinese
English Set the interface to English
Screen flip guan
open The screen is displayed in reverse
Automatic screen flip guan
open Gravity sensing automatically reverses
Dimming curve Square
linear A straight line
SCurve sine
InSquare logarithmic
RDM Function guan
open Disable the RDM function
DMX signal keep
reset The motor turns back and stops running
Screen saver guan
open Open the screensaver
X reversal guan
open The starting point and the ending point are switched
Reversal of Y guan
open The starting point and the ending point are switched
XY exchange guan
open Exchange XY axis channel (including fine tuning)
XY encoder open

and automatically correct the position
guan| No encoder (optocoupler) is used to correct the position
Restore Default Settings| | After you press the OK key, the confirmation dialog box is displayed. Press the OK key again to restore the default Settings

2.2.5 Running Mode

Self walking mode| DMX| Slave state: Receives DMX signals from the console or host
---|---|---
Since the go| Host state: Self-drive and send DMX signal to slave
Voice control

Manual control (Click the operation mode menu on the main interface, select the item manual control, and press “Confirm” to enter manual contro ) This interface is used to control the current lamp and automatically enter the host state (no DMX signal is received, in self-walking mode is the host and sends DMX signal to the bus to the slave machine). The manual menu displays 36 channels according to the standard 36 channels set in the Settings menu.

options instructions
1CH. X 0 – 255

hundreds digit and press
the Up and Down keys to change the channel value.Press OK again to select the
tens edit.Press ‘OK’ again to select the ones bit edit.Press again to exit the editing
| 0 – 255
35CH. Aperture|

| state
---|---
36CH. Reset| Press the ‘OK’ button and see the confirmation dialog box. Press the ‘OK’ button
Reset ALL| | Press the ‘OK’ button and see the confirmation dialog box. Press the ‘OK’ button again to enter the reset interface and reset all the motors
---|---|---
XY reset| | Press the ‘OK’ button to see the confirmation dialog box. Press the ‘OK’ button again to enter the reset interface and reset XY
MT reset| | Press the ‘OK’ button and see the confirmation dialog box. Press the ‘OK’ button again to enter the reset interface and reset the small motor

2.2.6 Factory Settings

options Instructions
Calibration of motor The X axis

adjust the reset position of X axis, V axis and other motors to make up for the error in hardware installation. The adjustment range is -128 to +127, and +0 indicates no adjustment.
Y
Disk of color
Fixed pattern plate
Glass pattern plate
Glass pattern rotation
Effect plate zero point
Stroke of effect plate
Apparent zero point
Apparent indicative stroke
Color temperature
cyan
magenta
yellow
focusing
amplification
Prism 1 zero point
Prism 1 stroke
Prism 2 zero point
Prism 2 stroke
Prism 1 rotation
Prism 2 rotation
Zero point of atomization
Stroke of atomization
Cutting rotary plate
The aperture
Cut 1
Cut 2

MAINTENANCE AND CLEANING

The following points have to be considered during the inspection:

  1. All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.
  2. There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).
  3. Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.
  4. The electric power supply cables must not show any damage, material fatigue or sediments.
    Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.

CAUTIONColor IMAGINATION FS600 Stage Lighting LED Moving Head Light -
icon 1
Disconnect from mains before starting maintenance operation.
In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the lights.

  1. Clean the inside and outside lens each week to avoid the weakneness of the lights due to accumulation of dust.
  2. Clean the fan each week.
  3. A detailed electric check by approved electrical engineer each three month, make sure that the circuit contacts are in good condition, prevent the poor contact of circuit from overheating.
    We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents.
    There are no serviceable parts inside the device. Please refer to the instructions under “Installation instructions”.
    Should you need any spare parts, please order genuine parts from your local dealer.

ADD F1-5, Block 3, No.95, Guangzhu Rd, Lanhe Town, Nansha District,
Guangzhou 511480
Tel. +86 20 8499 2310/2320/2330
Fax +86 20 8499 2360
E-mail : [email protected]
Website www.color-imagination.com
www.facebook.com/colorimagination.1
www.youtube.com/user/colorimaginationj
https://twitter.com/Color_lighting

http://www.color-imagination.com

Documents / Resources

| Color IMAGINATION FS600 Stage Lighting LED Moving Head Light [pdf] User Manual
FS600 Stage Lighting LED Moving Head Light, FS600, Stage Lighting LED Moving Head Light, Lighting LED Moving Head Light, LED Moving Head Light, Moving Head Light, Head Light, Light
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Color IMAGINATION User Manuals