Cirrus ACR3 Remote Control User Manual

June 3, 2024
Cirrus

OPERATION

Controls (Fig.2)
The hood is operated using the (5) push buttons located on the hood and the remote control.
LED colors are displyed on hood control only.

Cirrus ACR3 Remote Control- FIG. 2

P1: Activate/deactivate delay-off (10 minute)
P2: Filter change indication timer reset
P3: Decreases fan motor speed until turned off (4>3>2>1>OFF)
P4: Turns fan motor on and increased speed (ON>1>2>3>4)
P5: Lights off/low/medium/high
L1: LED Indicator Ring Signalling crown:
– Hood in standby: lights up green. 30 seconds after the last key has been pressed the crown turns off
– Motor on: L1 lights up blue fl ashing. The flashing frequency is proportional to the speed setting.
– 10’ TIMER function : L1 lights up and flashes blue.
– Filter alarm active: L1 lights up red

(P1) Delay- Off Switch

  • Your hood includes a 10 minute blower delay off switch. Press this switch once to activate the timer and the LED Ring (L1) fl ashes blue. The blower will continue to operate for 10 minutes. After 10 minutes, the blower turns off automatically.
  • To cancel the 10-minute delay, press the delay switch once again.

(P2) Filter Alarm Switch

  • After 30 hours of blower operation, the filter alarm is activated and the LED ring (L1) turns red/flashes. It indicates that the grease fi lters need to be cleaned.

  • After cleaning the grease fi lters, reset the hour counter by pressing the Filter Alarm/Timer
    Reset button (P2) during display of the alarm.
    (P3) Blower Speed Decrease and Off Switch

  • Press to decrease blower speed, high to low. The LED ring (L1) fl ashes blue at a speed proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)

  • Continue pressing this switch to turn the blower off.

(P4) Blower Speed Increase and On Switch

  • Press this switch to turn the blower on to low speed.
  • Press again to increase blower speed, low to high. The LED ring (L1) flashes blue at a speed proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)

(P5) Light Switch
Lights off/low/medium/high.

REMOTE CONTROL

The remote control is linked to the hood at the factory.
If, for some reason, the link is lost – follow the directions below:

To Link Remote Control to Hood

  1. Turn off hood motor and hood lights.
  2. Press and buttons on the remote simultaneaously for 5 seconds, until the remote control Indicator Light turns on (Fig.3). Release and buttons. Press and release button to confirm the linking. At this point the remote control Indicator Light starts flashing to confirm the link is active.
  3. Within 3 seconds – press ƒ (P2) on the hood control (Fig. 4). The LED ring will light up for approximately 10 seconds to confi m that the linking process was successful.

Cirrus ACR3 Remote Control-fig1

Remote Control Functions (Fig.3)
Delay – Off
– Blower Speed Decrease and Off
+ Blower Speed Increase and On
Light

See “Controls” section on previous page for more information on each function.
Press (Delay) and (Light) together to Reset Filter Alarm.
IMPORTANT: holding (Delay) for more than 3 seconds will cause the link between the remote and hood to be lost.
CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERY TO THE INSTRUCTION.

Battery disposal
When the batteries need to be replaced, dispose of them only and exclusively in the numerous readily available special waste bins, especially in shops selling electronic consumer goods. Observance of the regulations on differentiated waste collection, in particular, proper disposal of used batteries, contributes to preventing possible negative effects on the environment and health.