GARNET SeeLeveL-RV-2.0 Mobile Application User Guide
- June 13, 2024
- GARNET
Table of Contents
GARNET SeeLeveL-RV-2.0 Mobile Application
ABOUT THE APPLICATION
The See LeveL RV 2.0 app offers a wide range of powerful features to enhance your RV monitoring experience. With seamless compatibility for Apple iOS devices, this app allows you to effortlessly connect and monitor your tank levels and battery voltage right from your mobile device. The app provides real-time updates on up to four holding tanks, including fresh, grey, black, and LPG tanks. You can customize tank and device names, choose graphical tank fluid colors, and set personalized tank level alarms for timely notifications (see note below). The intuitive interface and Auto Connect feature ensure easy access to vital information directly from the Home Screen. With the See LeveL RV App, managing your resources and maintaining peace of mind while on the road has never been easier.
NOTE :
The iOS alarm feature is currently in Beta and has the following limitations:
- The alarm will not function while the app is closed or in the background.
- The alarm can only stay active for a few minutes (15 minutes or less)
These limitations will be addressed in a future update. expands on information for any procedures.
GETTING STARTED
Download and Install App
For Apple iOS devices go to the Apple App Store and search “SeeLeveL RV
2.0”.
Download and install the application.
**** NOTE: DON’T MISS OUT ON UPDATES
The app will be updated periodically. To avoid missing out on these updates,
make sure to enable auto-update in your app store or manually check for
updates.
Ensure Bluetooth®is Enabled
Once you have completed the installation, check that Bluetooth® is enabled in
your device settings.
Permission Requests
When you launch the SeeLeveL RV App for the first time, there are a few
permissions and settings that you need to allow to ensure optimal
functionality. Notifications, Device Positioning. Here are some examples of
these screens.
HOME SCREEN
From the home screen, you can select the following button options:
FIND MY TANKS SCREEN
Connect your Device
- After launching the SeeLeveL RV App on your mobile device, locate and select the “Find My Tanks” button. This will take you to the “Find My Tanks” screen. On the this screen, you should see a “find” icon, near the bottom of the screen.
- Tap on to start the scanning process. The app will begin scanning for available SeeLeveL tank monitor devices within range. Wait for a moment as the app searches for and detects the available devices.
- Once the scanning process is complete, the app will display a list of detected SeeLeveL tank monitor devices on the screen, and you can select one of them. Comparing the app tank levels to the levels shown on the tank monitor will ensure that you selected the correct device.
NOTE : Bluetooth has a typical range of up to 9 meters (30 feet) in order to function well inside the RV and its immediate surrounding area. Please ensure that your mobile device remains within this range of the tank monitor for optimal connectivity and reliable communication between the app and the tank monitor system. It is important to note that the actual range may vary depending on factors such as environmental conditions, obstructions, and the specific Bluetooth capabilities of your mobile device. Metal objects are a leading cause for Bluetooth disruption.
MY TANKS SCREEN
Tank Information
Once the connection is successfully established, you will be redirected to the
“My Tanks” screen of the app, where you can start monitoring your tank levels
and accessing other features. If the scan is unsuccessful, follow the
instructions on the screen.
Switch on Auto-Connect
The Auto-Connect feature eliminates the need for manual connection attempts
each time you use the app.
Enable the Auto-Connect feature by switching it to the “On” position.
Once the connection is established, you can conveniently access tank level
information directly from the app’s Home Screen using the “My Tanks” button
while in Bluetooth range.
CONFIGURATION
Edit Device Name
It is advised that you change the default device name “709-BTP3” to a unique
name so that you can distinguish your RV from other nearby RVs that are also
equipped with a SeeLeveL system, for example, “My RV”, or “John’s RV”, etc.
-
From the “My Tanks” screen, tap on the “edit” button located at the top right corner of the screen. The app will display an edit window where you can modify the device name.
-
Once you have entered the new name, select the button to save the changes, or to cancel.
Device Settings Options
Selecting the “gears” icon at the bottom of the screen allows you to do the following:
- Change the Bluetooth scan mode.
- Change the name of an individual tank.
- Change the fluid color of an individual tank.
- Choose whether or not to display an individual tank.
Select Bluetooth Scan Mode
Selecting different scan modes give you the ability to trade-off how quickly an app updates and how much battery life it uses. Battery consumption will rise with higher scan modes.
In device settings, select the “Scan Mode” dropdown menu. Select from the
Power Saver; low, medium, or high.
Select the button to save the changes, or to cancel.
Edit Tank Names
In device settings, scroll through to find the tank you want to change. Tap
the edit button next to “Edit name?”, enter the desired name. Select the
button to save the changes, or to cancel.
Change color of fluid in the tank
In device settings, scroll through to find the tank you want to change. Tap
the edit button next to “Edit Color?”, using the dropdown list of color
options, select a color you wish to designate for that tan. Select the button
to save the changes, or to cancel.
Enable Display Tank
In device settings, turn the toggle switch on or off to enable the tanks you
want to appear on the “My Tanks” screen.
ALARM SETTINGS (BETA)
Setting alarms for each tank in the SeeLeveL RV App is a valuable feature that allows you to proactively monitor your tank levels. Once an alarm is setup you will receive notifications when tank levels reach specific thresholds, alerting you to take necessary action promptly. Before setting alarms, make sure you are within the appropriate range. From the home screen of the app, locate and select the “Alarms” button. This will take you to the “Alarms” screen. Once you have selected the tank, you can customize the alarm settings for that tank. To select a tank.
To Select a Tank
Tap on the “add” button to create an alarm. Tap on the “Select Tank” dropdown
menu to expand options to open the “Set Alarm” screen. Scroll through to
choose the tank from the list and tap to select.
About Alarm Types
Different fluids in tanks require different alarm level settings. For tanks
that lose volume, like the fresh water or LPG tank, set low-level alarms to
alert you when levels drop. Tanks that gain volume, such as black or grey
tanks, should have high-level alarms to warn you when levels approach
capacity.
By setting the appropriate high-level or low-level alarms based on the fluid
type in each tank, you can effectively monitor the fluid levels and take
necessary actions.
To Select Alarm Type
On the “Set Alarm” screen, locate the “Alarm Type” dropdown menu, select
either “Low Level or High Level” based on the type of alarm you want to set.
Enter Alarm Activation Value
Please enter the percentage value at which the alarm will be activated when
the tank level is reached.
Once alarms have been configured on a tank, select the button to save the
changes, or to cancel.
Enable an Alarm
To enable the alarm, select the button.
To disable, select the button.
The alarm will stay active for a short amount of time while the app is in the
foreground. However, scanning for a device or navigating to the “My Tanks”
section will disable the alarm, as these actions require Bluetooth usage.
Delete an Alarm
To delete an alarm select the “remove” – button, select to save, select to
cancel.
Alarm Notifications
When a tank has reached its set threshold you will receive a notification.
Selecting the notification will take you the App’s home screen.
TROUBLESHOOTING
Bluetooth Disabled
If you disable Bluetooth services on your device, you will be prompted to
enable it.
Solution
Enable Bluetooth in device system settings.
Auto Connect Disabled
If you select “My Tanks” from the home screen and Auto-connect is disabled,
this error message is shown.
Failed to Start Alarm System
If you try to use the apps alarm feature without enabling auto-connect, this
error message is shown.
Error! Icon
An error icon as shown below will be displayed if there is an issue with the
users 709-BTP3 device.
Error Description
A pop-up dialogue box with the error description will appear when you select
the error icon.
Device Out of Range
Move within the appropriate distance.
APP HELP INFO
Help
Selecting the “help” icon at the bottom of the screen will display the
following help options:
USER GUIDE
User Guide Screen
Selecting the “Guide” button from the home screen will open a web browser and
take you to Garnet’s Resource library page where you can select the App user
guide to view or download.
Coming Soon: The “Video” button will take you to a tutorial video from
Garnet’s YouTube page.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>