Tecnosystemi 3M Heating Cable with Thermostat and Plug
Product Information
- Product Name : Frost
- Protection Heating Cable with Thermostat and Plug
- Model Number : COD. CMU00122 REV. 00
- Length Option s: 3/6/9/10 meters
- Classification: Class 1
- Manufacturer: TECNOSYSTEMI S.p.A.
- Website: www.tecnosystemi.com
- Address: Via dell’Industria, 2/4
- Z.I. San Giacomo di Veglia 31029
- Vittorio Veneto (Treviso)
- Italy
- Phone: +39 0438.500044
- Fax: +39 0438.501516
- Customer Service (Italy): Numero Verde 800 904474
- Email: info@tecnosystemi.com
Product Usage Instructions
- Make sure children are supervised to prevent them from playing with the appliance.
- All installation and maintenance operations should be performed by qualified and authorized personnel.
- Before any installation or maintenance, disconnect the product from the power supply.
- The product is not recommended for use by individuals with reduced physical, sensory, or mental capabilities,unless they have received proper guidance and instructions.
- During installation, maintenance, and repairs, it is important to follow these safety measures
- Use appropriate cable bending radius to avoid damage.
- Ensure the cable is always protected by a Residual Current Device (RCD).
- Keep the product away from dust.
- Avoid excessive pulling force on the cables. |
- Prevent crushing or overlapping of the heating element.
- Important points to consider when installing the heating cables
- Do not cut the cables to shorten their length.
- Position the flat surface of the thermostat sensor in the best possible location for optimal cable performance.
- Do not power the heating cable before installing it.
- Avoid touching the heating element when it is powered.
- Connect the cable to a properly protected electric power system.
- Do not apply excessive pulling force to the cables.
- Avoid crushing the cables in any way.
- Operating Specifications
- Power Output : Variable (not specified in the manual extract)
- Working Voltage : Variable (not specified in the manual extract)
- Insulation Material: Silicone
- Diameter: Not specified in the manual extract
- Activation Temperature : Not specified in the manual extract
- Shutdown Temperature: Not specified in the manual extract
- Length: XX meters (specific length should be mentioned)
- Minimum Bending Radius : Not specified in the manual extract
- Operating Temperature : Not specified in the manual extract
Note: The missing specifications should be obtained from the complete user manual or by contacting TECNOSYSTEMI S.p.A. directly.
Tecnosystemi S.p.A. – Società Benefit
- www.tecnosystemi.com
- via dell’Industria, 2/4
- Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso)
- Italy
- Phone +39 0438.500044
- Fax +39 0438.501516
- Numero Verde 800 904474 (only for Italy)
- email: info@tecnosystemi.com C.F. – P. IVA
- R.I.TV IT02535780247 | Cap. Soc. € 5.000.000,00 i.v.
GENERAL WARNINGS
The product is not intended to be used by people (including children) whose
physical, sensory or mental capacities are reduced, or who lack experience or
knowledge, unless they have been able to benefit, through the intermediation
of a responsible person their safety, supervision or instructions regarding
the use of the product.
Children must be supervised to ensure they do not play with the appliance.
Any product installation and/or maintenance operation must be carried out
exclusively by professionally qualified and authorized personnel.
TECNOSYSTEMI S.p.A. a Benefit Company declines all responsibility for any
damage caused by incorrect installation and improper use or tampering with the
control.
During installation, maintenance and repairs, for safety reasons, it is necessary
- The heating cable must be connected by a qualified electrician in accordance with current wiring regulations
- The connection cable (or plug) must not come into contact with water or other liquids.
- Make sure that the end cap at the end of the cable is not subjected to mechanical stress.
- If the heating cable is damaged, turn off the 230VAC Power immediately and replace the heating cable.
- Always protect the heating element against sharp edges, oil or heat.
- Never place the heating cable near explosive substances, objects or gases.
- Do not bend the cable below the minimum bending radius of 15 mm. The cable may sustain permanent damage in sections where the cable is bent under this radius.
- Incorrect handling and incorrect installation could damage the product.
- To minimize these risks and ensure that the system works
- reliably, carefully read and follow the information, warnings, and instructions in this guide.
- Make sure that the heaters are connected by a qualified electrician according to the regulations in force and are always protected by an RCD.
- Do not expose the product to flammable gas;
- Do not install in an explosive or corrosive atmosphere, in humid places, outdoors or in environments with a lot of dust
- Do not carry out any type of operation or maintenance, do not remove any protective element without first disconnecting the product from the power supply.
- Do not operate the unit without it and its electrical components having been connected to the building’s earth system;
Make the electrical connections according to the laws and national standards
in force.
Do not twist, detach or pull the electrical cables coming out of the product
even if it is not connected to the electrical supply.
Make sure that the electrical system is suitable for supplying, in addition to
the required operating current, also the current necessary to power household
appliances and appliances already in use.
Do not remove the product safety labels.
In case of illegibility, ask for a replacement.
It is dangerous to touch the product with wet body parts and bare feet.
ELEMENTI IMPORTANTI PER L’INSTALLAZIONE DEI CAVI RISCALDANTI
IMPORTANT POINTS TO INSTALL HEATING CABLES
- The cables must never be cut to shorten the length.
- The flat surface of the thermostat sensor must be placed in the best position, so that the cable can perform as required.
- Do not feed the heating cable before installing it.
- Do not fit the heating element if it is damaged.
- Do not touch the heating element when powered.
- The heating element must not intersect or overlap under any circumstances.
- Connect the cable to a properly protected electric power system.
- Do not apply excessive pulling force to them.
- Do not allow them to be crushed in any way.
SPECIFICHE DEL CAVO SCALDANTE
SPECIFICATIONS
DISEGNO TECNICO
TECHNICAL DESIGN CODICE
/ CODE DESCRIZIONE / DESCRIPTION
SCC300017: CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 15 W/m CON SENSORE
TERMI-CO INCORPORATO E SPINA 3 m
/ 15 W/m SILICONE ANTIFREEZE HEATING CABLE 3 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300020: CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 20 W/m CON SENSORE
TERMI-CO INCORPORATO E SPINA 3 m
/ 20 W/m SILICONE ANTIFREEZE HEATING CABLE 3 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300018 : CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 15 W/m CON
SENSORE TERMI-CO INCORPORATO E SPINA 6 m
/ 15 W/m SILICONE ANTIFREEZE HEATING CABLE 6 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300021 : CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 20 W/m CON
SENSORE TERMI-CO INCORPORATO E SPINA 6 m
/ 20 W/m SILICONE ANTIFREEZE HEATING CABLE 6 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300019 : CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 15 W/m CON
SENSORE TERMI-CO INCORPORATO E SPINA 9 m
/ 15 W/m SILICONE ANTIFREEZE HEATING CABLE 9 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300022 : CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 20 W/m CON
SENSORE TERMI-CO INCORPORATO E SPINA 9 m
/ 20 W/m SILICONE ANTIFREEZE HEATING CABLE 9 m LENGHT WITH BUILT-IN THERMAL
SENSOR
SCC300023 : CAVO SCALDANTE ANTICONGELAMENTO IN SILICONE 20 W/m CON
SENSORE TERMI-CO INCORPORATO E SPINA 10 m
/ 20 W/m SILICONE ANTIFREEZE HEATING CABLE 10 m LENGHT WITH BUILT-IN THERMAL
SENSOR
/ HEATING CABLES FOR PIPES CONDENSATION DRAINAGE
GENERAL GUIDELINES FOR INSTALLATION
Drain pipe heaters are uniquely designed to be laid inside pipes for draining
water from thawing refrigeration equipment’s installed in cold rooms. They
operate only during thawing cycles. In cold stores, after a certain time of
operation, there is a buildup of ice in cooler fins and defrosting must take
place. Electric resistances are inserted between the fins to melt ice and
water is collected and passed through a drain pipes for disposal. Some meters
of drain pipes are inside the cold stores, so consequently the water may
freeze again. To avoid this problem, a drain pipe heater is inserted in to the
pipe. It is switched on only during the defrosting cycles.
INSTALLAZIONE DEI CAVI RISCALDANTI PER TUBAZIONI
SCARICO CONDENSA E BACINELLE RACCOLTA CONDENSA
INSTALLATION OF HEATING CABLES FOR CONDENSATE DRAIN PIPES
AND CONDENSATE COLLECTION TRAYS
GARANZIA
WARRANTY
The warranty is valid for 2 (two) years from the delivery date indicated on
the delivery note / waybill.
The supplier company guarantees the quality of the materials used and the
correct construction of the components. The warranty covers defects in
materials and manufacturing defects and refers to the supply of spare parts of
any components featuring defects, without any compensation, interest or claim
for damages.
The warranty does not cover the replacement of components damaged due to
- incorrect transportation;
- installation not compliant with that specified in this installation, use and maintenance manual;
- non-observance of product technical specifications;
- Anything else that is not linked to original faults of the material or production provided that the customer complaint is covered by the guarantee and a claim is made within the time limit and in the way requested by the supplier, the same supplier will commit, at their own discretion, to replace or repair any product or part of product showing signs of faults or defects.
SMALTIMENTO
DISPOSAL
At the end of its useful life, the product must not be disposed of with
household waste. It can be deposited at a dedicated recycling centre run by
local councils, or at retailers who provide such a service. To highlight the
requirement to dispose of household electrical items separately, there is a
crossed-out waste paper basket symbol on the product.
Tecnosystemi S.p.A
www.tecnosystemi.com
via dell’Industria, 2/4 – Z.I. San Giacomo di Veglia 31029 Vittorio Veneto
(Treviso)
Italy
Phone +39 0438.500044 |
Fax +39 0438.501516
email: info@tecnosystemi.com
C.F. – P. IVA – R.I.TV IT02535780247
Cap. Soc. € 5.000.000,00 i.v.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>