CG WIND3D 65TR Air Cooler Instruction Manual
- June 13, 2024
- CG
Table of Contents
- THANK YOU
- INDEX
- QUICK START GUIDE
- USER TIPS
- SAFETY
- PARTS DESCRIPTION (MECHANICAL)
- Parts Description (ELECTRONIC)
- USE & OPERATION (ELECTRIONIC)
- OTHER FEATURES
- CLEANING & MAINTENANCE
- TRUOBLESHOOTING GUIDE
- ELECTRIONIC WIRING DIAGRAM
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CG WIND3D 65TR Air Cooler
THANK YOU
Congratulations on your purchase of this versatile CG Evaporative Air Cooler.
For optimum cooling from your cooler, fill the water tank to maximum level
before you turn on your air cooler.
Cooler Location (Important – Please Read!)
Place the cooler in front of an open door or window. Ensure that there is
adequate cross -ventilation in the room by leaving a door or window open
opposite the cooler. Following these guideline will ensure your cooler will
work as effectively as possible. Keep distance of minimum 0.5 meters from the
wall. Not an Air Conditioner (Important – Please Read!)
The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner
INDEX
Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty
QUICK START GUIDE
Fill the tank with water and plug the cooler in standard power outlet socket.
Note: Please make sure the household power voltage matches the product
specifications.
Place near an open door or window.
Note: Evaporative air cooler requires cross ventilation.
Turn ON and enjoy the cooling breeze.
Note: Start with low speed and gradually increase to higher speed for optimum
cooling performance.
USER TIPS
Energy efficient, No compressor
CG Evaporative Air Coolers are built to maximize energy efficiency and keep
costs low. Warm air is drawn into the cooler through the Cooling Media.
Water pumped from the tank pours over the Cooling media. As the warm air
passes through the Cooling media, the water absorbs the heat, naturally
cooling and humidifying the air. A fan propels the cooled air out into the
room. This nocompressor system cools naturally, efficiently and inexpensively.
The recommended maximum relative humidity level is 60% or less, which allows a
noticeable temperature decrease. The temperature decrease will be greater in
drier climates because higher evaporation occurs when the humidity is low.
Room with open windows & door (RECOMMENDED)
The evaporative air cooler should not be used in enclosed spaces. It must be
kept level and there must be water in the water tank. The room should have
doors and windows opened to allow free air flow. The evaporative air cooler
works best when placed near an open window, so that outside air is drawn into
the evaporative air cooler, the air circulates in the room, then exits via the
door. The maximum cooling effect is felt when a person is in the flow of air
coming out of the evaporative air cooler.
Room with closed windows & door ( NOT-RECOMMENDED)
NOTE
When the product is used for the first time the Honeycomb cooling media will have an odor which will dissipate in a week or so of initial use
SAFETY
READ AND SAVE THESE INSTRUCTIONS:
When using electrical appliances, basic safety precautions should always be followed:
-
Your cooler runs on 230 Volt AC, 50 Hz. Check the household voltage to ensure it matches the appliance’s rated specification.
-
Before operating the product remove it from its packaging and check that it is in good condition.
SHOCK HAZARD -
DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance.
-
DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over.
230 Volt AC 50 Hz -
Always unplug the product before refilling the watertank.
-
Always unplug the appliance from the power source before cleaning, servicing or relocating the unit.
-
Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, never pull the cord.
-
DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are stored.
WATER LEVEL INDICATOR -
When using the “COOL” setting, check the water tank to ensure that it is full. Operation of this cooleron the “COOL” setting with an empty tank may result in damage to the water pump.
-
DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty.
FIRE TOUCH -
DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage.
-
DO NOT insert or allow objects to enter any ventilation or exhaust opening as this maydamage the product and could cause an electrical shock or fire.
COOLER FLOOR SETTINGA -
DO NOT operate with the Honeycomb media removed as this will overload and damage the motor.
-
DO NOT leave the operating appliance unattended for an extended period of time.
-
DO NOT let children play with this appliance, packaging or plastic bags.
-
If the unit is damaged or it malfunctions, do not continue to operate it. Refer to the troubleshooting section and seek professional advice.
-
Place the unit on a level floor. This product is not intended for use in wet or damp locations.
-
DO NOT use in bathrooms. Never locate the product where it may fall into a water container.
-
Store in a dry area when not in use. This appliance is not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Always grip the side handles to move the cooler.
PARTS DESCRIPTION (MECHANICAL)
-
Top Panel Mounting
-
Horizontal Louver
-
Top Panel
-
Front Panel
-
Front Grill
-
Water Tank
-
Castor Wheel
-
Side Handle
-
Vertical Louver
-
Control Panel
Mechanical. -
Side Panel
-
Side Grill
-
Water Inlet
-
Water Level Indicator
-
Back Cover
-
Mosquito Repellent Holder
-
Back Panel
-
Back Grill
-
Over Flow Hole
-
Drain Plug
Mosquito Repellent Description
- Take out the holder tray of mosquito repellent from backside of cooler
- Unwrap the polybag of mosquito repellent cartridge and keep cartridge in the holder tray
- Keep the holder tray back to his position in the cooler
- Please keep this cartridge away from the children
- There can be a pungent smell from the cartridge which is normal
SPEED Selection Knob
Connect to the power supply and turn the SPEED knob.
The fan will start change the speed from “High” for High speed, to “Medium”
for Medium speed and to “Low” for Low speed.
To switch the fan OFF, turn the SPEED knob to “OFF”
COOL/SWING Selection Knob
It is multifunction knob.
Turn the knob towards COOL to get the cool air
Turn the knob towards COOL +SWING to get the cool air and to start automatic movement of Left-Right Vertical Louvers
Turn the knob towards Swing to start automatic movement of Left-Right Vertical Louvers
Parts Description (ELECTRONIC)
-
Top Panel Mounting
-
Horizontal Louver
-
Top Panel
-
Front Panel
-
Front Grill
-
Water Tank
-
Castor Wheel
-
Side Handle
-
Vertical Louver
-
Control Panel
Electronic. -
Side Panel
-
Side Grill
-
Water Inlet
-
Water Level Indicator
-
Back Cover
-
Mosquito Repellent Holder
-
Back Panel
-
Back Grill
-
Over Flow Hole
-
Drain Plug
CONTROL PANEL: (TOUCH)
General Features: –
TOUCH REMOTE
The Air Cooler model has following general features:-
- Display* : Display with LED indicators
- Different fan speed i.e. low, medium, high
- Memory backup in case of power failure
- Timer can be set in hour to turn the system ON/OFF
- ECO COOL – mode to save water and power consumption
- PRE-SOAK model to Pre-cool the honeycomb pads before starting the fan, releasing cool & fresh air
Note:
The remote control requires AAA (2 x 1.5V) batteries for replacement.
Open the battery compartment at the back of the remote control and insert the
AAA (2 x 1.5V) batteries inside. Care must be taken to insert the batteries
according to the correct polarity(+/-) markings shown inside the battery
compartment
Always point the remote control signal transmitter towards the unit when
operating.
Make sure that the signal path is not obstructed.
Remove the batteries if the unit is not going to be used for an extended
period of time.
Do not drop the remote control.Do not mix different types of batteries such as
alkaline, carbon-zinc, or rechargeable batteries.
Do not mix old and new batteries.
Exhausted batteries are to be removed from the product.
- In selected models only
USE & OPERATION (ELECTRIONIC)
DISPLAY:
There are LED’s on the Receiver board (Front display panel) to indicate the following functions:-
≠ Power:
To indicate supply in system. This led glow in standby condition.
≠ Cool :
To indicate the pump on/off condition.
≠ Fan Speed :
To indicate fan speed (low, medium, high).
≠ Timer:
To indicate timer is active or not.
≠ Swing:
To indicate swing is active or not.
≠ ECO COOL :
To indicate ECO Cool mode on/off condition.
Remote Key Features :-
Various keys & the function associated with them are as follows:-
POWER:
Pressing the power key, the unit turns to on or off.
FAN SPEED:
Press the fan speed key repeatedly to change the speed between low Medium and
High. The indicator light and dual digit display will show the fan speed.
SWING:
Press the swing key to tum on/off the swing motor.
If swing motor is on, its led indicator will illuminate.
If swing motor is off, its led indicator will be off.
Note: For vertical Air flow user can manually adjust the louvers.
COOL:
Pressing the cool key, pump motor and cool led will get on.
≠ DRY:
Pressing the dry key, pump motor and cool led will get off.
≠ Display* :
Pressing the display key, make the display On/Off.
- In selected models only
TIMER
- Timer can be selected (in hour) to tum on/off the system.
- Timer (in hours) can be selected as –
Note: While timer is enabled and mains power reset occurs, then timer will get disabled.
OTHER FEATURES
-
ECO COOL:
Pressing the ECO Cool key, pump motor will automatically tum On & off as per predefined periodic cycle. -
PRE-SOAK:
On Power ON in cool mode, it will tum on the pump motor first for few seconds before starting the Fan. It is a default feature.
CAUTION:
Unplug from power when refilling the water.
FILLING WATER(Manual) :
Do not over fill the tank
CLEANING & MAINTENANCE
IMPORTANT
-
The cooler is supplied with Cooling Media.
-
The cleaning frequency for the Cooling media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Cooling Media and restrict air flow.
Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Cooling media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
Do not run the unit in COOL mode with stale water in the tank. Empty the tank and refill it with fresh water if the water has been standing in the tank for an extended period of time. -
For best results, allow the Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off.
-
Draining the water reservoir and refilling with fresh water at least once a week will greatly reduce mineral deposits in the pads and help to extend the life of Cooling Media
WARNING
- Before cleaning the unit, switch it to the “off” position and remove the plug fromthe power socket.
- To clean the outside, use a damp cloth to remove dirt and dust.
- Never use corrosive elements or any chemicals to clean this product.
- When the product is not in use, store the unit in a dry place out of direct sunlight.
- Maximum water inlet pressure 0.5MPa
DRAINING AND CLEANING THE WATER TANK
- Turn the power “off” and disconnect the air cooler from the power supply.
- Move the unit to a location where it can be drained. Remove the cap from the water drain plug and allow the tank to empty (see parts description on page 9).
- After you have drained the water tank, please connect the water drain plug to its original position.
- Now refill the water tank up to Max level, wait for 5 min. and then drain the entire water once again. Use clean water for this procedure, so that maximum dust particles and remains are completely removed.
- If your cooler has not been used for a long duration, we advise you to clean the water tank at least 2 times before it is used again.
CLEANING THE COOLINGMEDIA
- Turn off the unit, and unplug the power cord from wall outlet Rotate the unit facing the back panel, and locate the Rear Grill Remove the screws with a screw driver
- Pull the rear grill panel backwards, until it is completely removed. Now, the Cooling Media can be seen. Clean the Cooling media with fresh water.
- Once the cleaning has been completed, assemble the unit as described above.
- Plug into the power supply and turn unit on.
WATER DRAIN PLUG
OPEN SCREWS
TRUOBLESHOOTING GUIDE
No discharge of air| Cord is not plugged in| Make sure power cord is plugged
in and the supply switch is on.
---|---|---
Power is not on| Turn the unit ON by changing the mechanical knob position of
the control panel
Motor Faulty| Contact Service centre
Not Cooling / Unit is making noise| Pump is not turned ON| On control Panel.
Turn COOL FUNCTION TO “ON”
Low or no water in tank, when COOL is selected| Refill water tank.
Damaged Pump| Contact service centre.
Odor omission| When the Cooler is new| When the unit is used for the first
time, the Cooling Media will
have an odor, which will dissipate within a week of
initial use. This is normal.
| If the Cooler has been used. There may be an algae issue.| Water is stale
Clean the tank and fill with fresh water.
Clean the Cooling Media.
If problem persists contact the service centre.
ELECTRIONIC WIRING DIAGRAM
Air Cooler Wiring Diagram (Electronic Model)
Air Cooler Wiring Diagram (Mehcanical Model)
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCEWITH EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as urban waste. II must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources.As a reminder of the need to dispose of household appliances separately, the product is marked with a crossedoutwheeled dustbin.
Visit us at: www.cginspiringlife.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>