VICTRIX 3.034120 V2 Zone Manager Kit Instruction Manual
- June 13, 2024
- VICTRIX
Table of Contents
VICTRIX PRO V2 ZONE MANAGER KIT
COD. 3.034120
THIS SHEET MUST BE LEFT WITH THE USER ALONG WITH THE BOILER INSTRUCTION BOOKLET
GENERAL WARNINGS
All products are protected with suitable transport packaging.
The material must be stored in a dry place protected from the weather.
This instruction manual provides technical information for installing the kit.
As for the other issues related to kit installation (e.g. safety in the
workplace, environmental protection, accident prevention), it is necessary to
comply with the provisions specified in the regulations in force and with the
principles of good practice.
Improper installation or assembly of the appliance and/or components,
accessories, kits and devices can cause unexpected problems for people,
animals and objects. Read the instructions provided with the product carefully
to ensure proper installation. Installation and maintenance must be performed
in compliance with the regulations in force, according to the manufacturer’s
instructions and by professionally qualified staff, meaning staff with
specific technical skills in the plant sector, as envisioned by the law.
SAFETY INSTRUCTIONS.
- The appliance is not suitable for children and must not be used as a toy.
- Store or dispose of packaging materials in a childproof manner.
- Do not disassemble the unit, it does not contain any user serviceable parts.
DESCRIPTION.
The RC130 serves as remote control with room temperature detection for the heatcon! system. The temporary desired temperature can be set using the + or – buttons. The RC 130 is integrated into the heatcon! system by means of addressing and can be assigned to a heatcon! EC and a room group (1 of max. 5).
INSTALLATION.
INITIAL COMMISSIONING.
- Connect the heatcon! EC to the terminals (A/B) of the RC130 mounting base.
- After connecting the EC heatcon to the mains, connect the RC130 to the mounting base.
- The start-up display shows the unit type and the software version.
- After 5 s, and during initial commissioning, the assignment (addressing) must be set.Use the + and – buttons to assign the heatcon! EC and the room group. An RC 130 can only be assigned to one heatcon! EC and one room group. The entry is saved by pressing the Prog.
- then jump to the basic display.
BASIC DISPLAY.
The basic display shows the current desired temperature in the upper line and
the actual temperature in the lower line.
+ AND – BUTTON.
Pressing the + or – key adjusts the desired temperature up or down.
During the adjustment, the desired temperature appears with a frame. After the
setting has been transferred to the heatcon! EC, the frame disappears again.
DISPLAY.
Display | Description |
---|---|
16,0°C (see figure 1 – top) | Current room setpoint, change via +/-. |
13,5°C (see figure 1 – bottom) | Current room temperature. |
Automatic mode heating, to comfort or economy temperature. | |
Heating (Party/Boost/Shower). | |
Automatic mode setback, according to setback temperature. | |
Setback ( go ). | |
Standby mode (standby/holiday), no room setpoint adjustment possible. | |
Weather-controlled summer shutdown. | |
Manual temporary room setpoint adjustment in automatic mode (magic wand). | |
Heating request active, provided a supply has been selected. | |
Cooling request active, provided a supply has been selected. | |
Error | Fault message. |
CHANGE OF ASSIGNMENT.
- If the assignment of the RC 130 is to be changed, remove the RC 130 briefly from the base and then plug it back in. The unit type and the software version are now displayed again.
- while displaying the unit type and software version, the control panel “Prog” must be kept pressed.
- After 5 seconds, the currently set assignment of the RC 130 is displayed. This can now be changed using the + or – keys according to the desired assignment. The entry is saved via the Prog.
TECHNICAL DATA.
Mounting type | Wall mounting |
---|---|
Power supply | via h2b system bus (safety extra- |
low voltage according to EN 60730)
Power consumption| < 200 mW
Protection class| 1P20
Maximum permissible cable
length| 100 m
Ambient temperature| 0 … 60 °C
Storage temperature| -25 … 60 °C
Colour| White (RAL 9016)
Dimensions| 82 x 82 x 26 mm
(length x width x height)
Housing material| ABS
Weight| 90 g
E bV
Elektronikbau and Vertriebs-GmbH
‘Heisterner Weg 8-12
D-57299 Burbach
Dispose of all replaced components and finally the controller itself in an
environmentally friendly manner and in accordance with the current legal
regulations of the respective country.
We reserve the right to make technical changes as well as changes to the
content of this document at any time without prior notice. EbV accepts no
responsibility for any errors or omissions in this document.
Copyright© 2022 EbV – Elektronikbau- und Vertriebs GmbH