tecnosoft DEEPWAVE Pressure Sensor User Guide

June 13, 2024
tecnosoft

Quick Start Guide
DEEPWAVE

Connections

tecnosoft DEEPWAVE Pressure Sensor - Connections

  1. Connect Helios to your LAN through an Ethernet cable
  2. Power up Helios with the provided adapter
  3. Position the Nodes in final location
  4. Connect the Smart Sensor to the Node
  5. Insert the batteries and/or power adapter
  6. Install TSLog21

Installing

Visit tecnosoft.eu

  1. Click on Software/Download > Techno Utility
  2. Download > Installing
  3. Run Techno Utility
  4. Installing TSLog21

tecnosoft DEEPWAVE Pressure Sensor - Setting

Connection to Database

SHIFT + double click on TSLog21 desktop icon

  1. Remote Select
  2. Enter Helios IP in the fields
  3. Click on Test Connection
  4. Click on Test Database If the buttons turn green, the connection is successful.
  5. Ok for confirmation

tecnosoft DEEPWAVE Pressure Sensor - Setting1

Connections
On first login create an Administrator:

  1. Set password
  2. Type First and Last name
  3. Upload an image of your signature (optional)
  4. Click on Ok to confirm

tecnosoft DEEPWAVE Pressure Sensor - Setting2

Configuration

Open Setup Tab

  1. Chance program language
  2. Set idle timeout user
  3. Change group label
  4. Change sensor label
  5. Set ban preferences after wrong password attempts

tecnosoft DEEPWAVE Pressure Sensor - Setting3

View the Data

Open Data tab

  1. Choose the group and position
  2. Choose time interval
  3. Statistics
  4. Sensor Info
  5. Battery charge
  6. Graph
  7. Acquisition Table
  8. Report Printing
  9. Non conformities Table

tecnosoft DEEPWAVE Pressure Sensor - Setting4

Add Nodes

Open Archive Tab

  1. Click on Gateways and Nodes
  2. Click on “Add” Node
  3. Type the S/N in Manual mode
  4. Click on Ok to confirm

tecnosoft DEEPWAVE Pressure Sensor - Setting5

Add Smart Sensor

After adding the Node

  1. Activate Smart Sensor position #1 and/or #2
  2. Set Acquisition rate #1
  3. Check external supply if existing #1
  4. Add 1 or 2 channels #1
  5. Click Ok to configure Smart Sensor #2

tecnosoft DEEPWAVE Pressure Sensor - Setting6

Edit Sensor position

Open Group/Position tab and select the Position
A Click on Move and select the Group
B Click Hide to avoid the list
C Clic Edit to open the window

  1. Click on LORA button to access the sensor
  2. Click on Unpair to change the Smart Sensor
  3. Add/Remove channel if necessary
  4. Click on Ok when finished

tecnosoft DEEPWAVE Pressure Sensor - Setting7

Node buttons

A Scroll through options in current view
B To previous page
C To next page
D Scroll page or option selection
E Reset the Node for reconfiguration
F Node model
G Node Serial Number

tecnosoft DEEPWAVE Pressure Sensor - Setting8

Node pages

Page 1

  1. Page number
  2. Smart Sensor position on Node
  3. First channel
  4. Second channel
  5. Last acquisition date and time
  6. Press D to switch from posn°1 to posn°2

Page 2

  1. Node Serial Number
  2. Firmware version
  3. Battery Level

Page 3

  1. Current Date & time
  2. Acquisition rate in seconds

Page 4

  1. Received Signal Strength Indication
  2. Signal Noise Ratio

tecnosoft DEEPWAVE Pressure Sensor - Setting9

Page 5

  1. Smart Sensor position on Node
  2. Status of sensor
  3. Press D to switch to other information
  4. Node Serial Number
  5. Calibration date
  6. Recommended recalibration date
  7. Press A to previous page

Page 6

  1. Smart Sensor position on Node
  2. Status of sensor

tecnosoft DEEPWAVE Pressure Sensor - Setting11

Page 7

  1. Press D to force an acquisition
  2. Press D to clear memory
  3. Press D to send status message
  4. Press A to show other options of page 7

tecnosoft DEEPWAVE Pressure Sensor - Setting12

Page 8

  1. Last detected alarm
  2. Alarm type
  3. Press D to swish from Alarm 1 to Alarm 2

Page 9

  1. Buzzer state
  2. Press D to change state (OFF-AUTO-ON)

Page 10

  1. Relay state
  2. Press D to change state (OFF-AUTO-ON)

tecnosoft DEEPWAVE Pressure Sensor - Setting13

Tecnosoft s.r.l.
Via Luigi Galvani, 4 – 20068 Peschiera Borromeo (Milano) – ITALY
e-mail: tecnosof@tecnosoft.eu 
web: www.tecnosoft.eu
1.3.4.8 – 01/01/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals