NOTE: PLEASE INSPECT THE HOOD IMMEDIATELY UPON RECEIVING IT. CLAIM OF
DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
This unit is designed for indoor and residential use only. DO NOT USE OVER A
WOOD GRILL OR MOUNT IN AN OUTDOOR ENVIRONMENT.
Please read this operation manual thoroughly before using your range hood. Store it in a safe location for when you need to reference it in the future.
SAFETY INFORMATION
**** TO REDUCE THE RISK OF A FIRE, ELECTRICAL SHOCK, AND/OR INJURY OBSERVE THE FOLLOWING:
- The unit is intended for indoor and residential use only. If you should have questions, contact the manufacturer at the address or telephone number listed in the warranty.
- In case the unit should need to be cleaned or repaired, switch power off at the service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by a qualified technician in accordance with all applicable codes and standards, including fire-rated construction.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- Because the unit is made of stainless steel, it may contain sharp edges. Be careful to avoid cuts and abrasions by wearing protective gloves during installation and cleaning.
- Before you begin to cut or drill into the wall, verify that there is no electrical wiring or any other hidden electrical components.
- Ducted fans must always be vented to the outdoors.
- The unit must be properly grounded and installed at the recommended height before beginning operation.
- To reduce the risk of fire, use only metal ductwork.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS
**** TO REDUCE THE RISK OF FIRE, OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
- Regardless of heat level, never leave any surface materials unattended while operating an open flame.
- Always turn the hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
- Depending on the amount of usage, clean ventilating fans and filters frequently. Grease should not be allowed to accumulate on the fan or filter. For instructions on how to clean, see the maintenance page.
- Never leave surface units unattended at high settings. Boil-overs may cause smoking and greasy spillovers may ignite as result. Heat oils slowly in low or medium settings.
- Use proper pan size. Always use cookware appropriate for the size of the surface element.
**** TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
- SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL 911.
- NEVER PICK UP A FLAMING PAN —Doing so may result in serious burns and possibly spread the fire.
- DO NOT USE WATER – Grease fire must be extinguished before further action may be taken. Using water will agitate the grease and may cause a violent steam explosion.
- Use a Fire Extinguisher ONLY if:
◊ You know you have a Class ABC extinguisher, and you already know how to operate it.
◊ The fire is small and contained in the area where it started.
◊ The fire department is being called.
◊ You are able to safely control the fire with your back to an open exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
**** PROP. 65 WARNINGS FOR CALIFORNIA RESIDENTS:
- This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
CONTENT CHECKLIST
-
CONTENTS INCLUDED
a. (1) RA2390 series (36”) hood assembly
b. (1) Lower duct cover (18-1/4”)
c. (1) Upper duct cover (18-1/4”)
d. (1) User’s manual
e. (1) 6” – 7” transition collar
f. (3) Magnetic baffle filters
g. (1) Screw packet -
CONTENTS NOT INCLUDED
a. RA2390EXT (Extension duct cover)
b. RA2390CFMR (CFM reducer)
c. 6” / 7” Aluminum or metal piping -
TOOLS REQUIRED (NOT INCLUDED)
a. Safety gloves
b. Safety glasses
c. Electric drill w/ starter bit
d. Utility knife
e. Spirit level
f. Measuring tape
g. Writing instrument (pen, marker, pencil)
h. Aluminum tape
MEASUREMENTS
PREPARATION
-
BEFORE YOU START
BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT
DO NOT INSTALL IF DAMAGED
RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED
a. Be sure you have all the content of your purchase and the required tools for this installation.
b. Installation may take at least 1 to 2 hours from start to finish.
c. Plan to use as few elbows or turns as possible for more efficient airflow.
d. Collar size may need to be increased if utilizing a long duct run.
e. At least 12” of the vertical duct is required before any turn.
f. Do not try to install this unit by yourself, SERIOUS INJURY MAY OCCUR.
g. At least two people are needed for installation.
h. Hiring a certified installer and electrician is recommended. -
LOCATION
THIS MODEL MAY NOT FIT ALL CEILING HEIGHTS
a. Determine the exact location you where want to install the range hood.
b. Distance between cooktop and range hood should be between 27”-33”.
c. Range hood should be mounted at stated measurements to ensure performance and lifespan of electrical components.
d. Correctly measure the dimension needed to install the unit. -
HOOD
a. Inspect for any sign of defect or damage. (ie. scratches, dents, loose seams, etc.)
b. Power up the unit to make sure it is working properly.
INSTALLATION
-
WALL MOUNT INSTALLATION
a. Make sure all preparation steps are completed.
b. Determine your ceiling height to see if you need an extension.
i. Hood unit height = 4-3/4”
ii. Duct cover height = 18-1/4” (lower) + 18-1/4” (upper)
iii. Minimum height (duct cover only) = 18-1/4”
iv. Maximum height (duct cover only) = 35-1/2”
v. (OPTIONAL) Extension duct cover height = 47”
vi. Maximum height (duct cover with extension only) = 65”
c. Determine the location you want to install the range hood. (Fig. 2a)
d. Prepare back wall frame with cross wood support.
e. Mount the unit onto wall with mounting screws (not included)
f. Adjust the duct cover mounting bracket to your desired height.
g. Use a spirit level to ensure the balance of the hood is true.
h. (OPTIONAL) Use the conversion collar for 7” ducting.
i. Connect a 6” or 7” ducting to the collar of the hood.
j. Connect the exhaust piping to the outlet of the unit. (Fig. 2b)
k. Finish off by sealing the connection point with aluminum tape.
l. Slide the duct cover into the unit and adjust its height. (Fig. 2c)
m. Secure it with the (6) duct cover screws provided. (Fig. 2d) -
EXTENSION DUCT COVER INSTALLATION (OPTIONAL) EXTENSION MAY REQUIRE MODIFICATION
Windster Hood will not be responsible for any modification done.
a. Replace the original upper duct cover piece with the extension.
b. Determine the desired height to mount the duct cover.
c. REPEAT “STEP F – M” of Section 1 WALL MOUNT INSTALLATION section. -
COLD WEATHER INSTALLATION (OPTIONAL)
a. Check with your local building codes to see if a CFM reducer is an acceptable alternative to make-up air.
b. Remove the RA2390CFMR (CFM Reducer) and inspect for any sign of defect or damage. (ie. Cracks, broken flips)
c. AFTER COMPLETING Step A – G of Section 1 WALL MOUNT INSTALLATION
d. Place the CFM reducer onto the outlet of the unit and seal the connection point with aluminum tape. (Be sure it is secure with no opening or gaps)
e. Connect a 6” or 7” ducting to the collar of the hood.
f. Connect the exhaust piping to the outlet of the unit. (Fig. 2b)
g. Finish off by sealing the connection point with aluminum tape.
h. Slide the duct cover into the unit and adjust its height. (Fig. 2c)
i. Secure it with the (6) duct cover screws provided. (Fig. 2d)
Installation diagram available on next page
INSTALLATION DIAGRAM
OPERATION & FEATURES
-
EASY ACCESS CONTROL SWITCH (from left to right)
a. Button 1 – ON / DELAY SHUTOFF / OFF
b. Button 2 – Light control
c. Button 3 – Speed control
d. Blue color speed indicator -
BAFFLE FILTERS
a. (3) 14-7/8” x 10-5/8” magnetic baffle filters
CLEANING & MAINTENANCE
WARNING!!!
To prevent the possibility of a fire and explosion, do not use flammable
liquids or solvents to clean the unit or any of its parts.
Check to make sure all power sources are disconnected before servicing
or taking the unit apart for cleaning.
**** Please thoroughly clean the unit weekly as stainless steel can rust
under certain conditions or by improper cleaning.
-
RANGE HOOD
a. Use household cleaners to remove grease or dirt from the outer shell of the unit. Spray on a wiping cloth or sponge and wipe in the direction of the grain to avoid scratching the unit. (DO NOT SPRAY DIRECTLY ONTO THE UNIT)
b. Clean the inner working of the unit periodically to avoid grease build-up.
c. Do not open the control switch panel while the hood is connected to power.
d. Use stainless steel cleaner to bring back the luster of the unit. -
BAFFLE FILTERS
a. Remove baffle filters from the unit and place in warm soapy water.
b. Clean the filters regularly to maintain efficient suction power.
c. Do not drop filters.
d. Let it soak thoroughly and then clean it with a wiping cloth or sponge.
e. Filters may also be cleaned using the residential dishwasher.
TROUBLESHOOTING
WARNING!!!
Check to make sure all power sources are disconnected before starting any
troubleshooting. Safety gloves and glasses should be worn when working on the
unit. Serious injury or death may occur if safety precautions are not
followed.
RA2390 Series
Light Issue (All not turning on)| 1. Halogen lights may need to be changed.
2. New Transformer replacement is required.
---|---
Halogen/LED light issue| 1. Check all wiring to and from the unit.
2. LED may require new fixture or transformer.
Light Issue (One light not turning on)| 1. LED light may be defective.
Speed indicator not showing speed levels| 1. Complete Control switch
replacement is required.
Burnt/melted control switch| 1. Complete Control switch replacement is
required.
Speed levels not working correctly| 1. Check all wiring to and from the unit.
2. Complete control switch replacement is required.
Unit lacking smoke intake| 1. Check to the duct for foreign objects.
2. Ensure the ducting is properly sealed.
3. Clean filters to increase airflow.
Unit showing no power indication| 1. Make sure the power source is working
properly.
2. All wiring is connected.
Unit making humming noise| 1. Replace the defective capacitor with a new one.
PART LIST / REPLACEMENT
# | Description |
---|---|
1 | Duct cover bracket |
2 | Duct cover |
3 | Hood bracket |
4 | Hood body assembly |
5 | LED lights |
6 | Control switch |
7 | Control board |
8 | Transformer |
9 | Capacitor |
10 | Motor support bracket |
11 | 6” – 7” transition collar |
12 | Squirrel cage motor |
13 | Baffle filters x 3 |
WARRANTY / CONTACT US
LIMITED WARRANTY
Windster Hoods Inc. warrants its product against defects in material or
workmanship as follows:
Labor: For a period of (1) year from the date of purchase, if the product
is determined to be defective, Windster will attempt to repair the product, at
its option, at no charge.
After the warranty period has expired, the consumer will be responsible for
all labor fees. (All labor repairs are limited to the installation of internal
components)
Parts: Windster Hoods, Inc. will supply, at no charge, new or rebuilt
replacements in exchange for defective parts for a period of two (2) years.
After the warranty period, the consumer will be responsible for all parts
costs. During the “parts” warranty period, there will be no charge for parts.
Motor: Windster Hoods, Inc. will also provide, at no charge, new or rebuilt motor parts in exchange for defective parts for a period of five (5) years, excluding motor cages. After the warranty period, the consumer will be responsible for all motor parts costs. During the “motor” warranty period, there will be no charge for motor parts. Please keep the original sales receipt, as it will constitute your proof of purchase. The consumer must provide the serial number and the original sales receipt to submit a warranty claim. Warranty claims submitted without serial numbers and original sales receipts will be denied. This warranty applies only to products purchased and serviced in the United States. For products purchased in Canada, please contact your local retailer where you purchased the unit for service. Windster Hoods, Inc. will not be held liable for removal and/or installation fees of the malfunctioning, defective, and/or replacement unit.
*Windster Hoods, Inc. reserves the right to determine the validity of your warranty claim.
WHAT IS NOT COVERED BY MANUFACTURER’S WARRANTY
-
Damages resulting from any of the following:
a. Improper installation or maintenance
b. Any repair, modification, alteration or adjustment not authorized by the manufacturer or an authorized service dealer
c. Misuse, accidents, and/or neglect
d. Incorrect electric current, voltage or power supply
e. Improper setting of any control (Pressing multiple selections at the same time)
f. Improper chemical cleaning (commercial or industrial cleaning agents) -
Products purchased for use in an outdoor, commercial, and/or industrial setting (such as in a hotel, office, restaurant, or other business)
-
Damage resulting from natural disasters (earthquake, flood, storm, etc.)
-
Regular maintenance for the product
-
Wear and maintenance items such as:
a. Aluminum Filters, Baffle Filters, Charcoal Filters, Mesh Filters, Oil cups, Lighting bulbs, light fixtures, etc. -
Corrosion
-
Oil Cup
-
Motor Cage
-
Light Bulbs
No returns refunds exchanges if the hood
- Is missing parts
- Been Installed
- Been Used
CONTACT US
Windster Hoods, Inc.
www.windsterhood.com
Information subject to change without notice
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>