Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner User Manual

June 16, 2024
Electrolux

Electrolux Logo ESV093C3XB ESV093C4YB
ESV123C3XB ESV123C4YB
ESV183C3XB ESV183C4YB
ESV243C3XB ESV243C4YB
AIR CONDITIONER
USER MANUAL

ESV093C3XB UltimateHome 300 Inverter Air Conditioner

WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance.
You’ve chosen a product that brings with it decades of professional experience and innovation. Ingenious and stylish, it has been designed with you in mind. So whenever you use it, you can be safe in the  knowledge that you’ll get great results every time.
Welcome to Electrolux.

Visit our website to:
Get usage advice, brochures, trouble shooter, service information: www.electrolux.com
Register your product for better service: www.electrolux.com/productregistration
Buy Accessories, Consumables and Original spare parts for your appliance: www.electrolux.com/shop

CUSTOMER CARE AND SERVICE

We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number
Warning / Caution-Safety information.
General information and tips
Environmental information.
Subject to change without notice.

SAFETY INSTRUCTIONS

Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference.

1.1 Children and vulnerable people safety
WARNING!
Risk of suffocation, injury or permanent disability.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in  a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.

1.2 Installation and Use
WARNING!
Risk of suffocation, injury or permanent disability.

  • Contact an authorised installer for installation of this unit.

  • Contact an authorised service technician for repair or maintenance of this unit.

  • The socket outlet required to supply power must be connected and commissioned by a licenced contractor.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similary qualified persons in order to avoid a hazard.

  • Installation work must be performed In accordance with the national wiring standards and the electricity suppliers service rules by authorised personnel only.

  • If the unit is to be moved to another location or disposed of, only a suitably qualified person is permitted to undertake such work.

  • If you notice an unusal situation, such as a burning smell, please switch off the power to the air conditioner and contact the brand service agent. If this abnormal status continues the air conditioner may be damaged or even cause electric shock or fire.

  • Do not operate the air conditioner with wet hands. This may cause electric shock.

  • Do not damage or cut off the power cord or other wires. If this occurs, please have it repaired or replaced by an accredited technician.

  • Do not connect this air conditioner to a multi outlet power board.

  • Please switch off the power supply to the air conditioner if it is not to be used for an extended period. Otherwise, it will accumulate dust and may cause a fire.

  • Before cleaning the air conditioner, please disconnect the power supply in order to eliminate the possibility of electric shock.

  • The power supply should be matched with the air conditioner.
    Air conditioners provided with a supply cord should be connected directly to a power outlet with a suitable safety switch. Air conditioners that are hard wired must be connected to a suitable safety circuit breaker.

  • Please ensure that the power supply to the air conditioner is stable and meets the requirements set out in the installation manual.

  • Always ensure the product is installed with appropriate earthing.

  • For safety, be sure to turn off the circuit breaker before performing any maintenance or cleaning or when the product is not used for an extended period of time. Accumulated dust may cause fire or electric shock.

  • Select the most appropriate temperature. It can save electricity.

  • Do not keep windows and doors open for a long time during operation. It will result in insufficient performance.

  • Do not block the air inlet or outlet. It will result in insufficient performance and cause malfunctions.

  • Keep combustible materials away from the units at least 1meter. It may cause fire.

  • Do not step on the top of the outdoor unit or place heavy things on it. It may cause damage or injury.

  • Do not attempt to repair the air conditioner by yourself. Incorrect repairs may cause electric shock or fire. Please contact your local authorised service centre.

  • Do not insert your hands or objects into the air inlet or outlet. It may cause injury.

  • Do not expose animals or plants directly to the airflow.

  • Do not use the unit for any other purpose, such as preserving food or drying clothes.

  • Do not splash water on the air conditioner. It may cause electric shock or malfunction.

Symbol Note Explanation
WARNING This symbol shows that this appliance uses a flammable

refrigerant.
If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
| CAUTION| This symbol shows that the operation manual should be read carefully.
| CAUTION| This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the operating manual or installation manual.

R32 refrigerant warning
This product uses R82 difluoromethane refrigerant, which is a mildly flammable gas class 2.2 according to ISO 5149 and must be handled by a refrigeration mechanic with appropriate refrigerant handling licence.

1.3 Minimum Floor Areas
This product uses mildly flammable R32 refrigerant. Certain levels of refrigerant require minimum room sizes. Please ensure that these minimum room sizes are adhered to for standard installations.

Type LFL kg/m³ hv m Total Mass Charged/kg Mimimum room area/m2
R32 0.306 1.224
0.6 29 51
1.0 10 19
1.8 3 6
2.2 2 4

PARTS NAME

Indoor Unit
Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - Indoor
Unit 1

  • If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation indetailsisas below: As shown in the figure, open panel and press aux. button to turn off the air conditioner.
    When the air conditioner is turned on, it will operate under auto mode.

Display

Temp. indicator|
---|---
Power indicator|

NOTE

  • This is the genera lintroduction and the color of indicator is only for reference. Please refer to the actual display.
  • Display content may be different from the actual. Please refer to the actual display.

Outdoor UnitElectrolux ESV093C3XB UltimateHome 300 Inverter Air
Conditioner - Indoor Unit 2

NOTE

  • Actual product may be different from above graphics, please refer to actual product.

OPERATION AND INTRODUCTION OF REMOTE CONTROLLER

3.1 Buttons on remote controller Electrolux ESV093C3XB UltimateHome 300
Inverter Air Conditioner - OPERATION AND INTRODUCTION

3.2 Introduction for icons on display screen

| I FEEL
---|---
| Set fan speed
(No f an speed. It’s displayed only after turning it on.)
| Turbo mode
| Send signal
Operation mode| | Auto mode
| Cool mode
| Dry mode
| Fan mode
| Heat mode (some units)
| Sleep mode
| 8 heating function (some units)
| I CLEAN
| Quiet
| X-FAN function

Temp. display type

| Set temp.
Indoor ambient temp.
Outdoor ambient temp.
| Clock
| Set temperature

WIFI

| WiFi function (some units)
| Set time

ONOFF

| TIMER ON / TIMER OFF
| Left & right swing (some units)
| Up & down swing
| Child lock
| Power limiting operation

3.3 Introduction for buttons on remote controller

NOTE

  • This is a general use remote controller . It could be used for the air conditioner with multifunction. For the functions which the model doesn’t have, if press the corresponding button on the remote controller , the unit will keep the original running status.
  • After putting through the power, the air conditioner will give out a sound. Power indicator “ ” is ON. After that, you can operate the air condit ioner by using remote controller.
  • Under on status, pressing the button on the remote controller, the signal icon “ ” on the display of remote controller will blink once and the air conditioner will give out a “di” sound, which means the signal has been sent to the air conditioner.

Press this button to turn on the unit. Press this buttonagain to turn off the unit.

Press this button to select your required operation mode.Electrolux
ESV093C3XB UltimateHome 300 Inverter Air Conditioner - button
1

  • When selecting auto mode, air conditioner will operate automatically according to ex-factory setting. Press “FAN” button can adjust fan speed. Press button can adjust fan blowing angle.
  • After selecting cool mode, air conditioner will operate under coo l mode. Press button to adjust set temperature. Press “FAN” button to adjust fan speed. Press button to adjust fan blowing angle.
  • When selecting dry mode, the air conditioner operates at low speed under dry mode. Under button to adjust fan blowing angle.
  • When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. Press “FAN” button to adjust fan speed. Press button to adjust fan blowing angle.
  • When selecting heat mode, the air conditioner operates under heat mode. Pre  button to adjust set temperature. Press “FAN” button to adjust fan speed. Press button to adjust fan blowing angle.(some units)

NOTE

  • For preventing cold air, a fter starting up heat mode, indoor unit will delay 1~5 minutes to blow air (actual delay time depends on indoor ambient temperature).
  • Set temperature range from remo tecontroller: 16~30 (61-86 ). Fan speed: auto, low speed, medium speed, high speed.

Pressing this button can set fan speed circularly as: auto (AUTO), low ( ), medium ( ) , high ( ).Electrolux ESV093C3XB UltimateHome 300 Inverter Air
Conditioner - button 2

NOTE
Unde AUTO speed, air conditioner will select proper fan speed automatically according to ex-factory setting.
It’s Low fan speed under Dry mode.

Under COOL or HEAT mode, press this button to turn to quick COOL or quick HEAT mode. “ ”
icon is dis-played on remote controller. Press this button again to exit turbo function and “ ” icon will disappear. If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temperature approachs the preset temperature as soon as possible.

  • Press button once increase or d ecrease set temperature 1℃ (°F). Holding  button, 2s later, set temperature on remote controller will change quickly. On releasing button after setting is finished, temperature indicator on indoor unit will  change accordingly.(Temperature can’t be adjusted under auto mode) When setting T-ON, T-OFF or CLOCK, press  button to adjust time. (Refer to CLOCK, T- ON, T-OFF buttons)

(some units)
Press this button can select left & right swing angle.”
Fan blow angle can be selected circularly as below:Electrolux ESV093C3XB
UltimateHome 300 Inverter Air Conditioner - button 3

NOTE

  • Press thi s button cont inuous l y more than 2s, the main unit will swing back and forth from left to right, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately.
  • Under left and right swing mode, when the status is switched from off to , if press this button again 2s later , status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.
  • The function is only available for some models.

Press this button can select up & down swing angle. Fan blow angle can be selected circularly as below:
Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - button
4

  • When selecting” “, air conditioner is blowing fan automatically. Horizontal louver will automat- ically swing up & down at maximum angle.
  • When selecting air condition- er is blowing fan at fixed position. Horizontal louver will stop at the fixed position.
  • When selecting , air conditioner is blowing fan at fixed angle. Horizontal louver will send air at the fixed angle.
  • Hold button above 2s to set your required swing angle. When reaching your required angle, release the button.

NOTE

  • may not be available. When air condi tioner receives this signal, the air conditioner will blow fan automatically.

  • Press this button continuously for more than 2s, the main unit will swing back and forth from up to down, and then loosen the button, the unit present position of guide louver will be kept immediately.

  • Under up and down swing mode, when the status is switched from off to , if press this button again 2s later , status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.

  • T-ON button
    “T-ON” button can set the time for timer on. After pressing this button, “ ” icon disappears and the word “ON” on remote controller blinks. Press button to adjust T-ON setting. After each pressing button, T-ON setting will increase or decrease  1min. Hold button, 2s later, the time will change quickly until reaching your required time. Press “T-ON ” to confirm it. The word “ON” will stop blinking. “ ” icon resumes displaying. Cancel T-ON: Under the condition that T-ON is started  up, press “T-O N” button to cancel it.

  • T-OFF button
    “T-OFF” button can set the time for timer off. After pressing this button, “ ” icon disappears and the word “OFF” on remote controller blinks. Press button to adjust T-OFF setting. After each pressing button, T-OFF setting will increase or  decrease 1min. Hold button, 2s later, the time will change quickly until reaching your required time. Press “TOFF” word “OFF” will stop blinking.  “ ” icon resumes displaying. Cancel T-OFF. Under the condition that T-OFF is started up, press “T- OFF” button to cancel it.

NOTE

  • Under on and off status, you can set T-OFF or T-ON simultaneously.
  • Before sett ing T-ON or T-OFF, please adjust the clock time.
  • After starting up T-ON or T-OFF,set the constant circulating valid.
    After that,air conditioner will be turned on or turned off according to setting time.ON/OFF button has no effect on setting.If you don’t need this function, please use remote controller to cancel it.

Press this button to start I FEEL function and “ ” will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature. Press this button again to cancel I FEEL function and “ ” will disappear.

  • Please put the remote controller near user when this function is set. Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate am bient temperature.When I FEEL function is turned on, the remote controller should be put within the a rea where indoor unit can receive the signal sent by the remote controller.

Press this button to set clock time. “ ” icon on remote controller will blink. Press button within 5s to set clock time. Each pressing of button, clock time will increas decrease 1 minute. If hold button , 2s later, time will change quickly. Release this button when reaching your required time. Press “CLOCK” button to confirm the time. “ ” icon stops blinking.

NOTE

  • Clock time adopts 24-hour mode.
  • The interval between two operations can ‘t exceed 5s.
    Otherwise, remote controller will quit setting status.
    Operation for TIMER ON/TIMER OFF is the same.

Under COOL, or HEAT mode, press this button to start up sleep function.
icon is displayed on remote controller. Press this button again to cancel sleep function and  icon will disappear.After powered on, Sleep Off is defaulted. After the unit is turned off, the Sleep function is canceled.
In this mode, set temperature will be adjusted with the change of time. Under Fan、 DRY and Auto modes, this function is not available.

Pressing this button in COOL or DRY mode, the icon “ ” is displayed and the indoor fan will continue operation for a while in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is Having set X-FAN function on: After turning off the unit by pressing ON/OFF defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.

  • Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for a while. at low speed.
    In this period, press X-FAN button to stop indoor fan directly.

  • Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.

When appliance is off, press the I CLEAN button to activate the I CLEAN feature, “ ” will show in the remote controller with flashing in few seconds, your unit will clean itself automatically. Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit. With regular use, most of this moisture is evaporated from the unit. You can use I CLEAN feature as often as you like.

Press this button to turn off display light on indoor unit. “ ” icon on remote controller disappears.
Press this button again to turn on display light. “ ” icon is displayed.

By pressing this button, you can see indoor set temperature , indoor ambient temperature or outdoor ambient temperature on indoor unit’s display.
The setting on remote controller is selected circularly as below:Electrolux
ESV093C3XB UltimateHome 300 Inverter Air Conditioner - button
5

  • When selecting “ ” or no display with remote controller, temperature indicator on indoor unit displays set temperature.
  • When selecting “ ” with remote controller, temperature indicator on indoor unit displays indoor ambient temperature.
  • When selecting “ ” with remote controller, temperature indicator on indoor unit displays outdoor ambient temperature.

NOTE

  • Outdoor temperature display is not available for some models. At that time, indoor unit receives “ ” signal, while it displays indoor set temperature.
  • It’s defaulted to display set temperature when turning on the unit.There is no display in the remote controller. Only for the models whose indoor unit has dual-8 display.
  • When selecting displaying of indoor or outdoor ambient temperature, indoor temperature indicator displays corresponding temperature and automatically turn to display set temperature after three or five seconds.

3.4 Function introduction for combination buttons
Energy-saving function
Under cooling mode, press “TEMP” and “CLOCK” buttons simultaneously to start up or turn off energy-saving function.
When energy-saving function is started up, “SE” will be shown on remote controller, and air conditioner will adjust the set temperature automat ical ly according to ex-factory setting to reach to the best energy-saving effect.
Press “TEMP” and “CLOCK” buttons simultaneously again to exit energy-saving function.

NOTE

  • Under energy-saving function, fan speed is defaulted at auto speed and it can’t be adjusted.
  • Under energy-saving function, set temperature can ‘t be adjusted. Press “TURBO” button and the remote controller won’t send signal.
  • Sleep function and energy-saving function can ‘t operate at the same time.
    If energy-saving function has been set under cool mode, press “SLEEP” button will cancel energy-saving function.
    If sleep function has been set under cool mode, start up the energy-saving function will cancel sleep function.

8 heating function (some units)
Under heat mode, press “TEMP” and “CLOCK” buttons simultaneously to start up or turn off 8 heating function. When this function is started up, “ ” and “8 ” will be shown on remote controller, and the air conditioner keep the heating status at 8 . Press “TEMP” and “CLOCK” buttons simultaneously again to exit 8 heating function.

NOTE

  • Under 8 heating function, fan speed is defaulted at auto speed and it can’t be adjusted.
  • Under 8 heating function, set temperature can’t be adjusted. Press “TURBO” button and the remote controller won’t send signal.
  • Sleep function and 8ºC heating function can’t operate at the same time. If 8ºC heating function has been set under heat mode, press “SLEEP” button will cancel 8 heating function. If sleep function has been set under heat mode, st art up the 8ºC heat i ng function will cancel sleep function.
  • Under temperature display, the remote controller will display 46 heating.

Child lock function
Press simultaneously to turn on or turn off child lock function. When child lock function is on, “ ” icon is displayed on remote controller.
If you operate the remote controller, the “ ” icon will blink three times without sending signal to the unit.

Temperature display switchover function
Under OFF status, press “ ” and “MODE” buttons simult aneously to switch temperature display between ºC and ºF.

WiFi function (some units)
Press “MODE” and “TURBO” button simultane- ously to turn on or turn off WiFi function. When WiFi function is turned on, the “WiFi” icon will be displayed on remote con troller ; Long press “MODE” and “TURBO” buttons simultaneously for 10s, remote  controller will send WiFi reset code and then the WiFi function will be turned on. WiFi function is defaulted ON after energization of the remote controller. (This function only applicable for some models)

3.5 Replacement of batteries in remote controllerElectrolux ESV093C3XB
UltimateHome 300 Inverter Air Conditioner - remote
controller

  1. Lift the cover along the direction of arrow (as shown in Fig 1(1)).
  2. Take out the original batteries (as shown in Fig 1(2)).
  3. Place two 7# (AAA 1.5V) dry batteries, and make sure the position of “ +” polar and “ -” polar is correct (as shown in Fig 2‘3) ).
  4. Reinstall the cover (as shown in Fig 2 (4).

NOTICE

  • During operation, point the remote control signal sender at the receiving window on indoor unit.
  • The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
  • Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation.
  • Replace new batteries of the same model when replacement is required.
  • When you don’t use remote controller for a long time, please take out the batteries.
  • If the display on remote controller is fuzzy or there’s no display, please replace batteries.

CLEAN AND MAINTENANCE

WARNING

  • Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
  • Do not wash the air conditioner with water to avoid electric shock.
  • Do not use volat ile liquid to clean the air condit ioner.
  • Do not use liquid or corrosive detergent to clean the appliance and do not splash water or other liquid onto i t , otherwi se, it may damage the plastic components , even cause electric shock.

4.1 Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.

NOTICE

  • Do not remove the panel when cleaning it .

Clean filter

  1. Open panel
    Pull out the panel to a certain angle as shown in the fig.Electrolux
ESV093C3XB UltimateHome 300 Inverter Air Conditioner - Clean surface
1

  2. Remove filter
    Remove the filter as indicated in the fig.Electrolux ESV093C3XB UltimateHome
300 Inverter Air Conditioner - Clean surface 2

  3. Clean filter
    • Use dust catcher or water to clean the filter.
    • When the filter is very dirty, use the water (below 45℃) to clean it , and then put it in a shady and cool place to dry.Electrolux ESV093C3XB
UltimateHome 300 Inverter Air Conditioner - Clean surface
3

  4. Install filter
    Install the filter and then close the panel cover tightly.Electrolux
ESV093C3XB UltimateHome 300 Inverter Air Conditioner - Clean surface
4

WARNING

  • The filter should be cleaned every three months .
    If there is much dust in the operation environment, clean frequency can be increased.

  • After removing the filter, do not touch fins to avoid injury.

  • Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.

NOTICE: Checking before use-season

  1. Check whether air inlets and air outlets are blocked.
  2. Check whether air switch, plug and socket are in good condition.
  3. Check whether filter is clean.
  4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  5. Check whether drainage pipe is damaged.

NOTICE: Checking after use-season

  1. Disconnect power supply.
  2. Clean filter and indoor unit’s panel.
  3. Check whether mounting bracket for outdo or unit is damaged or corroded. If yes, please contact dealer.

Notice for recovery

  1. Many packing materials are recyclable mate- rials. Please dispose them in appropriate recycling unit.
  2. If you want to dispose the air conditioner , please contact local dealer or consultant service center for the correct disposal method.

4.2 Error Code
When air conditioner status is abnormal, tempe- rature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code.

Error code Troubleshooting
E5,E8,E6, H6,H3,E1 It can be eliminated after restarting the unit. If not,

please contact qualified professionals for service.
C5 F0 F1| Please contact qualified professionals for service.

NOTE

  • If  there ‘ re ot her error codes, please cont act qualified professionals for service.

CHECKED ITEMS BEFORE MAINTENANCE

5.1 General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals.

Phenomenon Check items Solution

Indoor unit can’t receive remote controller’s signal or remote  controller has no action.| Whether it’s interfered severely (such as static electricity, stable voltage?)| Pull out the plug.
Reinsert the plug after about 3min, and then turn on the unit again.
Whether remote controller is within the signal
receiving range?| Signal receiving range is 8m.
Whether there are obstacles?| Remove obstacles.
Whether remote controller is pointing at the receiving window?| Select proper angle and point the remote controller at the receiving window on indoor unit.
Is sensitivity of remote controller low;
fuzzy display or no display?| Check the batteries.
seirettab for ewope ht fIis too low , please replace
them.
No display when operating remote controller?| Check whether remote controller appears to be damaged. If yes, replace it.
Fluorescent lamp in room?| Take the remote controller close to indoor unit.
Turn off the fluorescent lamp and then try it again.
No air emitted from indoor unit| Air inlet or air outlet of indoor unit is blocked?| Eliminate obstacles.
Under heating mode, indoor temperature is reached to set temperature?| After reaching to set temperature, indoor  unit will stop blowing out air.
Heating mode is turned on just now?| In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
Air conditioner can’t operate| Power failure?| Wait until power recovery.
Is plug loose?| Reinsert the plug.
Air switch trips off or fuse is burnt out?| Ask professional to replace air switch or fuse.
Wiring has malfunction?| Ask professional to replace it.
Unit has restarted immediately after stopping operation?| Wait for 3min, and then turn on the unit again.
Whether the function setting for remote controller is correct?| Reset the function.
Mist is emitted from indoor unit’s air outlet| Indoor temerature and humidity is high?| Because indoor air is cooled rapidly.
After a while, indoor temperature and humidity will be decrease and mist will disappear.
Odours are emitted| Whether there’s odour source, such as furniture and cigarette, etc.| Eliminate the odour source. Clean the filter.
Set temperature can’t be adjusted| Unit is operating under auto mode?| Temperature can’t be adjusted under auto mode. Please switch the operation mode if you need to
adjust temperature.
Your required temperature exceeds the set  temperature range?| Set temperature range: 16℃~30℃.
Cooling (heating) effect is not good.| Voltage is too low?| Wait until the voltage resumes normal.
Filter is dirty?| Clean the filter.
Set temperature is in proper range?| Adjust temperature to proper range.
Door and window are open?| Close door and window.
Air conditioner operatesabnormally| Whether there’s interference, such as thunder, wireless devices, etc.| Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vapor| Heating mode is turned on?| During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.
“Water flowing” noise| Air conditioner is turned on or turned off just now?| The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Cracking noise| Air conditioner is turned on or turned off just now?| This is the sound of friction caused by expans i on and or contraction of panel or other parts due to
the change of temperature.

WARNING

  • When below phenomenon occurs,please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
  • Power cord is overheating or damaged.
  • There’s abnormal sound during operation.
  • Air switch trips off frequently.
  • Air conditioner gives off burning smell.
  • Do not repair or refit the air conditioner by yourself.
  • Indoor unit is leaking.
  • If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.

INSTALLATION NOTICE

Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner -
INSTALLATION

6.1 Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
warning

  • When installing or relocating the unit, be sure to keep the refrigerantcircuit free from air or substances other than the specified refrigerant.
    Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.

  • When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.
    Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even serious safety accident.

  • When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.
    Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
    Please note that the time for refrigerant recovery should not exceed 1 minute.
    If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.

  • During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detachi- ng the connection pipe.
    If compressor starts running when stop valve is open and connection pipe is not yet conn- ected, air will be sucked in and cause pressure rise Or compressor rupture, resulting in injury.

  • When installing the unit, make sure that co- nnection pipe is securely connected before the compressor starts running.
    If compressor starts running when stop valve is open and connection pipe is not yet conne- cted, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.

  • Prohibit installing the unit at the place where there may be leaked corrosive gas or flamm- able gas.
    If there is leaked gas around the unit, it may cause explosion and other accidents.

  • Do not use extension cords for electrical co- nnections. If the electric wire is not long eno- ugh, please contact a local service center au- thorized and ask for a proper electric wire. Poor connections may lead to electric shock or fire.

  • Use the specified types of wires for electrical connections between the indoor and outdoo units. Firmly clamp the wires so that their te- rminals receive no external stresses.
    Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.

6.2 Tools for installation

  1. Level meter
  2. Screw driver
  3. Impact drill
  4. Drill head
  5. Pipe expander
  6. Torque wrench
  7. Open-end wrench
  8. Pipe cutter
  9. Leakage detector
  10. Vacuum pump
  11. Pressure meter
  12. Universal meter
  13. Inner hexagon spanner
  14. Measuring tape

NOTICE

  • Please contact the local agent for installation.
  • Don’t use unqualified power cold.

6.3 Selection of installation location

Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please consuIt the local dealer:

  1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the air.
  2. The place with high-frequency devices (such as welding machine, medical equipment).
  3. The place near coast area.
  4. The place with oil or fumes in the air.
  5. The place with sulfureted gas.
  6. Other places with special circumstances.
  7. The appliance shall not be installed in the laundry.
  8. It’s not allowed to be installed on the unstable or motive base structure (such as truck) or in the corrosive environment (such as chemical factory).

Indoor unit

  1. There should be no obstruction near air inlet and air outlet.
  2. Select a location where the condensation water can be dispersed easily and won’t affect other people.
  3. Select a location which is convenient to connect the outdoor unit and near the power socket.
  4. Select a location which is out of reach for children.
  5. The location should be able to withstand the weight of indoor unit and won’t increase noise and vibration.
  6. The appliance must be installed 2.5m above oor.
  7. Don’t install the indoor unit rignt above the ele- ctric appliance.
  8. Please try your best to keep way from fluorescent lamp.

Outdoor unit

  1. Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborhood.
  2. The location should be well ventilated and dry, in which the outdoor unit won’t be exposed directly to sunlight or strong wind.
  3. The location should be able to withstand the weight of outdoor unit.
  4. Make sure that the installation follows the requirement of installation dimension diagram.
  5. Select a location which is out of reach for children and far away from animals or plants. If it is unavoidable, please add the fence for safety purpose.

Safety precaution

  1. Must follow the electric safety regulations when installing the unit.
  2. According to the local safety regulations, use qualified power supply circuit and air switch.
  3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  4. Properly connect the live wire, neutral wire and grounding wire of power socket.
  5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
  6. Do not put through the power before finishing installation.
  7. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  9. The appliance shall be installed in accordance with national wiring regulations.

Grounding requirement

  1. The air conditioner is the first class electric appliance. It must be properly grounded with specialized grounding device by a professional.
    Please make sure it is always grounded effectively, otherwise it may cause electric shock.

  2. The yellow-green wire in air conditioner is grounding wire, which can’t be used for other purposes.

  3. The grounding resistance should comply with national electric safety regulations.

  4. The appliance must be positioned so that the plug is accessible.

  5. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.

6.5 Air switch capacity
Including an air switch with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protecting the  circuit)

Air-conditioner Air switch capacity
09K 10A
15K 18K 16A
24K 25A

INSTALLATION OF INDOOR UNIT

Step 1: Choose installation location
Recommend the installation location to the client and then confirm it with the client.

Step 2: Install wall-mounting frame

  1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall.
  2. Drill the screw fixing holes on the wall with impact drill(the specification of drill head should be the same as the plastic expansion particle) and then fill the plastic expansion particles in the holes.
  3. Fix the wall-mounting frame on the wall with tapping screws and then check if the frame is firmly installed by pulling the frame. If the plastic expansion particle is loose, please drill another fixing hole nearby.

Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner -
INSTALLATION 2

Step 3: Open piping hole

  1. Choose the position o f piping hole according to the direction o f outlet pipe. The position of piping hole should be a li ttle lower than the wall-mounted frame, shown as below.
    NOTE
    • The wall panel is for illustrat ive purposes only, please refer to the actual installation.
    • Please refer to the actual circumstances for the number of screws and the position of screws.

  2. When installation is finished, pull the mounting plate with hand to confirm whether it is fixed The force distribution for all screws should be uniform.

  3. Open a piping hole with the diameter of ∅55 or ∅70 on the selected outlet pipe In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.

NOTE

  • Pay attention to dust prevention and take re le vant safety measures when opening the hole.

Step 4: Outlet pipe

  1. The pipe can be led out in the direction of right, rear right, left or rear left.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 4
  2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 5

Step 5: Connect the pipe of indoor unit

  1. Aim the pipe joint a t the corresponding bellmouth.
  2. Pretighten the union nut with hand.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 6
  3. Adjust the torque force by referring to the following shee t. Place the open-end wren ch on the pipe join t and place the torque wrench on the union nut. Tighten the union nut with torque wrench.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 7
    Hex nut diameter| Tightening torque (N m)
    ---|---
    1/4″| 15~20
    3/8″| 30~40
    1/2″| 45~55
    5/8″| 60~65
    3/4″| 70~75
  4. Wrap the indoor pipe and join t of connect ion pipe with insulating pipe, and then wrap it with tapeElectrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 8

Step 6: Install drain hose

  1. Connect the drain hose to the outlet pipe of indoor unit.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 9
  2. Bind the joint with tape.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 11

NOTE

  • Add insulating pipe in the indoor drain hose in order to prevent condensation.
  • The plastic expansion particles are not provided.

Step 7: Connect wire of indoor unit
NOTICE

  • All wires of indoor unit and outdoor unit should be connected by a professional.
  • If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid e- xtending the wire by yourself.
  • For the air conditioner with plug, the plug should be reachable after finishing installation.
  • For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-pole parting and the contact parting distance should be more than 3mm.
  1. Open the panel, remove the screw on the wiring cover and then take down the cover.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 12

  2. Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 13

  3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip. Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 14NOTICE
    • The wiring board is for reference only, please refer to the actual one.

  4. Put wiring cover back and then tighten the screw.

  5. Close the panel.

Step 8: Bind up pipe

  1. Bind up the connection pipe, power cord and drain hose with the band.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 15
  2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 16
  3. Bind them evenly.
  4. The liquid pipe and gas pipe should be bound separately a t the end.

NOTICE

  • The power cord and control wire can’t be crossed or winding.
  • The drain hose should be bound at the bottom.

Step 9: Hang the indoor unit

  1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
  2. Hang the indoor unit on the wall-mounting frame.
  3. Stuff the gap between pipes and wall hole with sealing gum.
  4. Fix the wall pipe.
  5. Check if the indoor unit is installed firmly and closed to the wall.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 17

NOTICE
Do not bend the drain hose too excessively in order to prevent blocking.

INSTALLATION OF OUTDOOR UNIT

Step 1: Fix the support of outdoor unit
(select it according to the actual installation situation)

  1. Sel ect installation location according to the house st ruct ure.
  2. Fix the support of outdoor unit on the selected location with expansion screws.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 18

NOTICE

  • Take sufficient protective measures when installin g the outdoor unit.

  • Make sure the support can withstand at least fou r times of the unit weight.

  • The out door un it should be installed at leas t 3cm above the floor in order to install drain joint.
    (for the model with heating tube, the installation height should be no less than 20cm.)

  • For the unit with cooling capacity of 2300W ~ 5000W, 6 expans ion screws are needed ; for the unit with cooling capacity of 6000W~8000W, 8 expans on screws are needed; for the unit with cooling capacity of 10000W~16000W, 10 expansion screws are needed.

Step 2: Install drain joint
(only for some models)

  1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
  2. Connect the drain hose into the drain vent.

NOTICE

  • As for the shape of drainage join t, please refer to the current product. Do not install the drainage joint in the severe cold area. Otherwise,it will be frosted and then cause malfunction.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 19

Step 3: Fix outdoor unit

  1. Place the outdoor unit on the support.
  2. Fix the foot holes of outdoor unit with bolts.

Step 4: Connect indoor and outdoor pipes

  1. Remove the screw on the right handle of out- door unit and then remove the handle.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 21 NOTE
    • When there’re multiple cables passing through it, the cross-hole of handle should be knocked off and eliminate the sharp burrs for avoid damaging the cables.
    • Only applicable for some models.

  2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 23

  3. Pretighten the union nut with hand.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 24

  4. Tighten the union nut with torque wrenchv by referring to the sheet below.

Hex nut diameter Tightening torque(N .m)
1/4” 15~20
3/8” 30~40
1/2” 45~55
5/8” 60~65
3/4” 70~75

Step 5: Connect outdoor electric wire

  1. Remove the wire clip; connect the power connection wire and signal control wire (only for cooling and heating unit) to the wiring terminal according to the color; fix them with screws.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 25 NOTICE
    • The wiring board is for reference only, please refer to the actual one.

  2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).
    NOTICE
    • After tighten the screw, pull the power cord slightly to check if it is firm.
    • Never cut the power connection wire to prolong or shorten the distance.

Step 6: Neaten the pipes

  1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiam eter of bending the pipe is 10cm.
  2. If the outdoor unit is higher than the wall hole, you must se t a U-shaped curve in the pipe before pipe goes into the room, in order to prevent rain from getting into the room.

NOTICE

  • The through-wal height of drain hose shoul not be higher than the outlet pipe hole of indoor unit.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 27
  • The water outlet can’t be placed in water in order to drain smoothly.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION 28
  • Slant the drain hose slightly downwards.
    The drain hose can’t be curved, raised and fluctuant, etc.Electrolux
ESV093C3XB UltimateHome 300 Inverter Air Conditioner - INSTALLATION
29

TEST AND OPERATION

9.1 USE VACUUM PUMP

  1. Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent.
  2. Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
  3. Open the piezometer completely and operate for 10-15min to check if the pressure of piezometer remains in -0.1MPa.
  4. Close the vacuum pump and maintain this sta- tus for 1-2min to check if the pressure of piezo- meter remains in -0.1MPa. If the pressure de- creases, there may be leakage.
  5. Remove the piezometer, open the valve core of liquid valve and gas valve completely with inner hexagon spanner.
  6. Tighten the screw caps of valves and refriger- ant charging vent.
  7. Reinstall the handle. Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - OPERATION

9.2 LEAKAGE DETECTION

  1. With leakage detector: Check if there is leakage with leakage detector.
  2. With soap water: If leakage detector is not available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, there’s a leakage.

9.3 CHECK AFTER INSTALLATION

  • Check according to the following requirement after finishing installation.
Items to be checked Possible malfunction
Has the unit been installed firmly? The unit may drop, shake or emit noise.
Have you done the refri- gerant leakage test? It may cause insufficient

cooling(heating) capacity.
Is heat insulation of pipe- line sufficient?| It may cause condensation and water dripping.
Is water drained well?| It may cause condensation and water dripping.
Is the voltage of power supply according to the voltage marked on the nameplate?| It may cause malfunction or damage the parts.
Is electric wiring and pip- eline installed correctly?| It may cause malfunction or damage the parts.
Is the unit grounded securely?| It may cause electric leakage.
Does the power cord fol- low the specification?| It may cause malfunction or damage the parts.
Is there any obstruction in the air inlet and outlet?| It may cause insufficient cooling(heating) capacity.
The dust and sundries caused during installation are removed?| It may cause malfunction or damage the parts.
The gas valve and liquid valve of connection pipe are open completely?| It may cause insufficient cooling (heating) capacity.
Is the inlet and outlet of piping hole been covered?| It may cause insufficient cooling (heating) capacity or waste electricity.

9.4 TEST OPERATION

  1. Preparation of test operation
    • The client approves the air conditioner.
    • Specify the important notes for air conditioner to the client.

  2. Method of test operation
    • Put through the power, press ON/OFF button on the remote controller to start operation.
    • Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check whether the operation is normal or not.
    • If the ambient temperature is lower than 16 C ,the air conditioner can’t start cooling.

CONFIGURATION OF CONNECTION PIPE

  1. Standard length of connection pipe: 5m, 7.5m, 8m.

  2. Min. length of connection pipe.
    For the unit with standard connection pipe of 5m, there is no limitation for the min length of con- nection pipe. For the unit with standard connec- tion pipe of 7.5m and 8m, the min length of con- nection pipe is 3m.

  3. Max. length of connection pipe is shown as below.
    Max. length of connection pipe**** Cooling capacity| Max. length of connection pipe(m)
    ---|---
    5000Btu/h (1465W)| 15
    7000Btu/h (2051W)| 15
    9000Btu/h (2637W)| 15
    12000Btu/h (3516W)| 20
    18000Btu/h (5274W)| 25
    24000Btu/h (7032W)| 25
    28000Btu/h (8204W)| 30
    36000Btu/h (10548W)| 30
    42000Btu/h (12306W)| 30
    48000Btu/h (14064W)| 30

  4. The calculation method of additional refrigerant oil and refrigerant charging amount after prolonging connection pipe.
    After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.
    The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
    (1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional refrigerant charging amount per meter
    (2)Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe.
    See Sheet .

Additional refrigerant charging amount for R32

Piping size Indoor unit throttle Outdoor unit throttle
Liquid pipe Gas pipe Cooling only, cooling and heating
(g / m) Cooling only
(g / m) cooling and heating

(g / m)
1/4″| 3/8″ or 1/2″| 16| 12| 16
1/4″ or 3/8″| 5/8″ or 3/4″| 40| 12| 40
1/2″| 3/4″ or 7/8″| 80| 24| 96
5/8″| 1″ or 1 1/4″| 136| 48| 96
3/4″| —| 200| 200| 200
7/8″| —| 280| 280| 280

NOTICE
The additional refrigerant charging amount in Sheet is recommended value, not compulsory.

10.1 PIPE EXPANDING METHOD
NOTICE
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:

A: Cut the pipe

  • Confirm the pipe length according to the distance of indoor unit and outdoor unit.
  • Cut the required pipe with pipe cutter.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - OPERATION 2

B: Remove the burrs

  • Remove the burrs with shaper and prevent the burrs from getting into the pipe.

C: Put on suitable insulating pipe
D: Put on the union nut

  • Remove the union nut on the indoor connection pipe and outdoor valve; install the union nut on the pipe.

E: Expand the port

  • Expand the port with expander.Electrolux ESV093C3XB UltimateHome 300 Inverter Air Conditioner - OPERATION 5
Outer diameter (mm) A(mm)
Max Min
ø6 – 6.35(1/4″) 1.3
ø9 – 9.52(3/8″) 1.6
ø12-12.7(1/2″) 1.8
ø15.8-16(5/8″) 2.4

F: Inspection
Check the quality of expanding port. If there is any blemish, expand the port again according to the steps above.Electrolux ESV093C3XB UltimateHome
300 Inverter Air Conditioner - OPERATION 6

10.2 WORKING TEMPERATURE RANGE

| Indoor side
DB/WB(°C)| Outdoor side
DB/WB(°C)
---|---|---
Maximum cooling| 32/23| 43/26

NOTE
• The operating temperature range (outdoor temperature) for cooling only unit is 18°C~43°C.

ESV243C3XB / ESV243C4YB:

| Indoor side
DB/WB(°C)| Outdoor side
DB/WB(°C)
---|---|---
Maximum cooling| 32/23| 50/26

NOTE
• The operating temperature range (outdoor temperature) for cooling only unit is 18°C~50 °C.

SPECIALIST’S MANUAL

  • The following checks shall be applied to installations using flammable refrigerants:

    • the charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    • the ventilation machinery and outlets are operating adequately and are not obstructed;
    • if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    • marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    • refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components,  unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
  • Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.

  • Initial safety checks shall include:

    • that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    • that no live electrical components and wiring are exposed while charging, recovering or purging the system;
    • that there is continuity of earth bonding.
  • Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

  • Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  • Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  • Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.

  • Checks to electrical devices

    • that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    • that no live electrical components and wiring are exposed while charging, recovering or purging the system.
  • Repairs to sealed components
    During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is   absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.

    • Ensure that the apparatus is mounted securely.
    • Ensure that seals or sealing materials have not de- graded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
      NOTE: The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
  • Repair to intrinsically safe components
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the  quipment in use.
    Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
    Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  • Cabling
    Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into  account the effects of aging or continual vibration from sources such as compressors or fans.

  • Detection of flammable refrigerants
    Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  • Leak detection methods
    Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.

  • Decommissioning
    Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely.
    Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
    a) Become familiar with the equipment and its operation.
    b) Isolate system electrically.
    c) Before attempting the procedure, ensure that:
    – mechanical handling equipment is available, if required, for handling refrigerant cylinders;
    – all personal protective equipment is available and being used correctly;
    – the recovery process is supervised at all times by a competent person;
    – recovery equipment and cylinders conform to the appropriate standards.
    d) Pump down refrigerant system, if possible.
    e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    f) Make sure that cylinder is situated on the scales before recovery takes place.
    g) Start the recovery machine and operate in accordance with manufacturer’s instructions.
    h) Do not overfill cylinders. (No more than 80% volume liquid charge).
    i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
    j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.

  • Labelling
    Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  • Recovery
    When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
    When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible,  cooled before recovery occurs.
    The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants.
    In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
    The recovered refrigerant shall be returned to the  refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
    If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

ENVIRONMENT CONCERNS

Recycle the materials with the symbol .
Put the packaging in applicable containers to recycle it. Help protect the environment and human health and to recycle waste of electrical and electronic appliances.

Do not dispose appliances marked with the symbol with the household waste.
Return the product to your local recycling facility or contact your municipal office.

www.electrolux.com/shop


References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>