Billi Alpine 060 Home C with Round Slimline Dispenser Installation Guide
- September 10, 2024
- Billi
Table of Contents
Billi Alpine 060 Home C with Round Slimline Dispenser
FAQs
Q: Can I install the dispenser below the spill level of the sink?
A: No, the dispenser must not be installed below the spill level of the receiving fixture to ensure proper operation.
Q: What size hole is needed for mounting the dispenser tap?
A: A 22mm hole is required either in the benchtop or flat surface of the sink adjacent to the sink bowl.
PRODUCT INFORMATION
Components for Alpine 060 and Alpine 120 Before commencing installation, ensure you have identified the following.
- Chilled Water Module
- Installation Requirements
- Installation Hardware and Dispenser
- Warranty
Water Supply
A single cold water supply is required. Supply Pressure: 200 – 1000 Kpa Supply Temperature: 5°C – 30°C
Do not install with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Power Requirements
A single 10 amp standard power outlet is required. The Chiller module is supplied with 1 meter of flex cord and plug.
Drainage
A drainage point, such as a dishwasher nipple or a tundish, is required.
Product Usage Instructions
- IMPORTANT: This Billi appliance is to be installed by a licensed tradesperson in accordance with AS/NZS 3500.1 and AS/NZ 3500.2 and in compliance with applicable state regulatory requirements. For the correct operation of this appliance, it is essential to observe the manufacturer’s instructions.
- Determine Component Location
- A stop tap (not supplied) is to be installed in an easily accessible position for later service. Determine the location of each of the components, taking into account the tube lengths and space available. Refer to Diagrams 1 & 2.
- Mount Backflow Prevention/Pressure Regulator Valves
- Fit certified pressure limiting valve with dual internal check valve for backflow prevention (supplied) to stop tap, in accordance with enclosed manufacturer’s instructions.
- Flush Lines
- It is important to flush lines before fitting. Install outlet fitting to the combined valve. Refer to Diagram 4.
- Install Dispenser Tap Assembly DISPENSER MUST NOT BE INSTALLED BELOW THE SPILL LEVEL OF THE RECEIVING FIXTURE.
- A 22mm hole is required either in the benchtop or flat surface of the sink adjacent to a bowl of the sink. Mount the dispenser tap. Refer to Diagram 3.
- Install Chiller Module
- Connect all plastic tubing as shown. Refer to Diagram 4. All connections are made using push-fit connectors. Trim tubes to the correct lengths. Tubes should be cleanly cut square using a sharp knife or plastic tube cutter. Ensure that tube ends are round and not flattened or kinked, then push into connectors firmly until properly seated (to release, press the outer ring in while pulling gently on the tube).
- Install Drain Connection
- The Billi dispenser tap incorporates an air break above the spill level of the sink and therefore a tundish is not required. Connect a 3/8″ drain tube to the dishwasher nipple, or alternative drainage point, using fittings supplied.
- ENSURE THE DRAIN TUBE HAS A CONTINUAL FALL.
- Turn on Water Supply
- Pull the dispenser tap lever and then turn on the water supply. After water flows from the outlet, release the lever and ensure that there are no leaks. Pull the lever again and run for at least 5 minutes.
- Turn on Electricity Supply
- Set Chilled Water Temperature
- Set the desired water temperature using a temperature control knob. Refer to Billi Alpine User Guide.
- Re-check Connections for Leaks
- Explain the Operation to the User
SAFETY INSTRUCTION
WARNINGS
For the continued safety of this appliance, it must be installed, operated, and maintained in accordance with the manufacturer’s instructions.
- Your appliance should be installed by a suitably qualified tradesperson.
- For the correct operation of this appliance, it is essential to observe the instructions as outlined in this booklet.
- Filter replacement must be performed at intervals of not more than 6 months.
- Use this appliance only as directed in these instructions and only for its designed purpose.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- DANGER: The operation of the thermal cut-out indicates a possibly dangerous situation. Do not reset the thermal cut-out until the water heater has been serviced by a qualified person.
- WARNING: Do not connect any restrictor or pressure relief device to the vent pipe of this water heater if installed.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
- New hose-sets supplied with the appliance are to be used and old hose sets should not be re-used.
Scan the QR Code to access the Support page and Shop online.
CONTACT INFORMATION
- Billi Australia Pty Ltd
- 42 Lucknow Crescent, Thomastown
- Victoria 3074 Australia
- Telephone 1800 812 321
- www.billi.com.au
Designed and manufactured in Australia. As Billi Australia Pty Ltd has a policy of continual improvement, all details are subject to change without notice. Allgoods are sold subject to our published terms and conditions. Billi is a registered trademark. 05-0624
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>