tuya TRV603 Smart WiFi Radiator Thermostat Instruction Manual
- June 13, 2024
- Tuya
Table of Contents
- WI-F1 Smart Thermostatic Radiator Valve
- Technical specifications
- Standard accessories
- Display Symbols
- Installation
- Temperature control mode
- Stop heating and pause heating
- Adjust setting temperature and Screen rotation
- 0pen window function and Anti scale
- Child lock function and Restore factory settings
- APP remote control and voice control
- Download Smart Life APP
- ADD device
- Mode selection
- Week program setting
- Advanced setting
- Statistics
- Click “ ” to enter the Temperature Statistics.
- Device sharing functional
- Voice control
- Troubleshooting and maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TRV603 Smart WiFi Radiator Thermostat
Instruction Manual
WI-F1 Smart Thermostatic Radiator Valve
- Automatic debugging function, suitable for all kinds of mainstream valves
- The device supports WI-Fl fast distribution network, no additional gateway is required
- Intelligent PID algorithm, efficient control of valve opening and closing, energy saving and environmental protection
- The motor adopts ultra-quiet technology to minimize noise pollution
- The device has activated the automatic conversion of summer time and winter time, which can be activated or terminated as needed
Technical specifications
Power Supply: | 3 x 1.5 V alkaline PA batteries (not Included) |
---|---|
Protection Degree: | IP20 |
Ambient Temperature: | 0-50t |
Surface Temperature: | 90t Max (at the radiator) |
Connection: | M30 x 1.5mm |
Linear Travel: | 4.3mm |
Dimensions(W x H x D): | 58.4mm x 97wn x 58.4mm |
Weight | 117.7 g |
Standard accessories
Display Symbols
Installation
-
Press the battery compartment lock, remove the cover, and insert the batteries.
-
Initialize, the mandrel puffs back, then “ ” is displayed and blinking on the screen.
-
When “ ” stop blinking, install the IRV union nut with M301.5 thread for heating valve, and then tighten the nut.
*Attention:
While inserting the batteries, please make sure the polarity? of battery (+1-) is aligned. -
Press the middle button and then” ” start blinking, the device enter valve-adjusting process. After several minutes, the process is completed when initialized screen is displayed.
How to install the adapter correctly
Temperature control mode
Temperature control mode
Press the middle button to switch between Auto mode and Manual mode.
*Attention: Only Manual mode is available when the device is not
connected to Internet.
-
Auto mode
When ” ” is displayed on the screen, it is under Auto mode. Four time periods and setting temperature could be programmed per day, one week as a cycle, based on customized needs. -
Manual mode
When ” ” is not displayed on the screen, it is under Manual mode. The device will work according to current setting temperature, without controlled by the time period program. -
Temporary mode
Under Auto mode, “ ” will be blinking after setting temperature, and then it will enter Temporary mode. The device is switched to Manual mode temporarily, without controlled by the time period program. It will return to Auto mode by next time period.
Stop heating and pause heating
- ON: In summer, rotate the knob clockwise until “ ” is displayed under manual mode to stop heating. At this time, the heating valve is fully open. This can extend the use life of valve.
- OFF: In winter, rotate the knob counterclockwise until “ ” is displayed under manual mode to pause heating temporarily. At this time, the heating valve is closed and the frost protection is activated.
*Attention: After the antifreeze function is activated, the valve will open when the room temperature is lower than 5°C, and the valve will be closed when the room temperature exceeds 7°C to prevent damage to the radiator thermostatic valve due to freezing
Adjust setting temperature and Screen rotation
- Adjust setting temperature: Rotate the knob to adjust setting temperature, stepping by 0.5°C.
- Screen rotation: Long press the Set Button for 3 seconds to switch the screen display direction.
0pen window function and Anti scale
- Open-window function: First, enter the APP home page to turn on the window detection function, the device will automatically identify whether the window is open. When it is detected that there is cold wind, and the temperature drops by more than 1.5°C within 4.5 min, the open-window function will be activated. At this time, the screen displays and the temperature is set to 12°C.
- Anti-scale: TRV executes routine decalcification every Monday at 12:00 to protect the valve from calcification. ‘ ” will be displayed on the screen during decalcification.
*Attention: Attention: While the open-window function is activated, 1 following operations will terminate it from taking effect.1 Temperature setting operation on the APP or device. 2 The detected temperature rises by more than 1.5°C within 4.5 minutes. (3) No operation on the APP or device within 30 minutes.
Child lock function and Restore factory settings
- Child lock function: Long press the middle button for 3 seconds until “ ” is displayed on the screen to activate the child lock. While the device is locked, long press middle button for 3 seconds until “ ” disappear to deactivate the child lock.
- Restore fatty settings: Long press the middle button and insert the battery at the same time until “ ” is displayed on the screen and blinking for 3 seconds, the device will be restored to factory settings and restarted.
*Attention: Once the device is restored to factory settings, all previous settings can not be recovered.
APP remote control and voice control
Download Smart Life APP
https://smartapp.tuya.com/smartlife
Scan the QR code above or search “Smart Life” on App Store and Google Play to download the Smart Life APP.
ADD device
- Under manual mode, rotate the knob counterclockwise until “ ” is displayed. Then long press the middle button for 3 seconds until ” ” is blinking. *Attenticrt Network configuration can only be done under manual mode. Please turn on the Bluetooth of your phone in advance.
- Enter the ” Home” interface of the APP, click ” ” in the upper right corner, select the ” Add ” button in the pop-up window, and finally click ” ” to enter the Wi-Fi password interface;
- Select 2.4G Wi-Fi and enter the password, click “Next”, and then wait for the connection to succeed.
- After the addition is successful, click “Next” , and the wifi smart thermostat has been added successfully.
Mode selection
- Click ” ” to select mode.
*Attention: Click ” + ” or ” -” to adjust the setting temperature.
Auto mode: Four time periods and setting temp. could be programmed per day, one week as a cycle, based on customized needs.
Manual mode: The device will work according to current setting temp. without controlled by the time period program.
Off mode: The valve will be closed to stop heating.
ON mode: The valve will open in heating.
Week program setting
- Click ” L ” to enter the week program setting page.
- Set four time periods and setting temperature based on customized needs.
Advanced setting
- Click to enter the advanced setting page.
Statistics
Click “ ” to enter the Temperature Statistics.
Device sharing functional
- Share the device to other family members, allowing them to remotely control the IRV device.
- Example of mobile phone A sharing mobile Phone B
- Click the Menu button, then click “Share Device”
- Click “Add home member”.
- Fill in account information of home member.
- Mobile phone B agrees to join
Voice control
- After waking up the speaker, you can say:
Amazon Alexa : Alexa, - Set the DEVICENAME to 26 degree
- Drop the DEVICENAME by 1 degree
- Raise the DEVICENAME by 1 degree
- Make the DEVICENAME warmer
- Turn on the DEVICENAME child lock
- Turn off the DEVICENAME child lock
- What temperature is the DEVICENAME set to
- What is battery on the DEVICENAME
Google Assistant : OK google,
* Set the DEVICENAME to 23 degree - Tum on the DEVICENAME child lock
- Turn off the DEVICENAME child lock
- IS my DEVICENAME child lock on?
- Turn on child lock for the DEVICENAME
- Turn off child lock for the DEVICENAME
- Set the DEVICENAME to auto
- Set the DEVICENAME to manual
*Attention: “DEVICENAME” is the device name, you can also name it yourself. The temperature unit of TRV and smart speaker must be identical.
Troubleshooting and maintenance
Error code | Problem | Solution |
---|---|---|
FO | Temperature sensor abnormality | Contact after-sales staff |
F1 | Slow valve operation | Check the installation and heating valve |
F2 | The stroke is too long | Check the fastening of TRV |
F3 | The stroke is too short | Check the heating valve |
F4 | Running out of battery | Replace batteries immediately |
Battery symbol ( ) | Low battery | Replace batteries within 4 weeks |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>